Schedule Service

Heating, Cooling, Plumbing & Electrical Repair in Akron, OH

Akron is filled with older neighborhoods where home systems have been pieced together over decades. From the century-old homes near Highland Square and North Hill to post-war houses around Firestone Park and Ellet, many homeowners here are dealing with aging ductwork, outdated breaker panels, worn sewer lines, and HVAC systems that were never designed for today’s demand. Blind & Sons is in Akron every week handling these exact kinds of problems across areas near Route 8, Arlington Road, Market Street, and the neighborhoods surrounding Portage Lakes.

A furnace breakdown in January or a flooded basement after heavy rain is not something Akron homeowners can put off. If you need help with heating, cooling, plumbing, or electrical work, call (330) 753-7711 or contact Blind & Sons online to schedule service with a team that already knows the layouts, infrastructure, and common repair issues found throughout Akron homes.

Working in Akron Homes Every Day4

Akron homes tell you their age the second you walk into them. Some still have original plaster walls and older boiler systems. Others have newer additions connected to ductwork that was never redesigned to support the extra square footage.

We spend a lot of time in neighborhoods near West Exchange Street, Merriman Valley, Goodyear Heights, and Springfield Township where systems have been repaired, expanded, and modified over generations of ownership. In many homes, comfort problems are not caused by one failed part. They come from years of small upgrades layered onto older systems.

AC Repair & Cooling Systems in Akron, OH

Cooling complaints across Akron usually start with airflow. Older homes throughout the city often struggle to move enough conditioned air upstairs, especially during humid stretches in July and August. We also see a lot of enclosed porches, converted attics, and home additions that were added without properly updating the cooling system.

Air conditioning and cooling services we handle throughout Akron include:

In neighborhoods with mature trees and older insulation, it is common for certain rooms to stay warmer than the rest of the house no matter how long the AC runs. Our technicians look at the full system, including duct layout, airflow balance, and equipment sizing, instead of just replacing parts and hoping the issue goes away.

Indoor Air Quality Solutions in Akron, OH

Many Akron electrical systems were built long before modern households started running multiple TVs, gaming systems, large HVAC equipment, kitchen appliances, and EV chargers at the same time. It is common for us to find older panels and overloaded circuits in homes that have gone through years of remodeling. Electrical services we handle throughout Akron include:

  • Electrical repair
  • Electrical installation
  • Electrical inspections
  • Whole-home generators
  • Indoor and outdoor lighting
  • Electrical panel upgrades
  • Surge protection
  • EV charger installation
  • Electrical wiring and rewiring

We also see a lot of older homes with partial rewiring jobs where sections of original wiring are still mixed with newer upgrades. If lights flicker, breakers trip regularly, or outlets feel warm, the electrical system should be inspected before the issue becomes more serious.

Furnace & Heating Repair in Akron, OH

Older Akron homes place a heavy demand on heating equipment during Northeast Ohio winters. We regularly work on furnaces and boilers that have been running for decades, especially in homes built before the 1970s where airflow and insulation standards were very different from today. Heating services available throughout Akron include:

  • Emergency heating repair
  • Heating maintenance
  • Furnace repair and replacement
  • Boiler repair and installation
  • Heat pump services
  • Ductless HVAC systems
  • Hybrid heating systems

Some of the most common calls we see involve uneven temperatures between floors, noisy ductwork, short cycling furnaces, and rooms that never seem to fully warm up. In a lot of Akron homes, those issues trace back to aging duct systems or previous remodels that changed airflow patterns inside the house.

Plumbing Repair & Drain Services in Akron, OH

Plumbing issues in Akron vary from neighborhood to neighborhood. In older parts of the city, we frequently run into aging drain lines, sewer backups, and galvanized plumbing that has narrowed over time. In newer residential areas, sump pump failures and water pressure issues are more common. Plumbing services we provide throughout Akron include:

  • Plumbing repair
  • Plumbing maintenance
  • Drain cleaning
  • Water heater repair and installation
  • Plumbing fixtures
  • Sewer services
  • Sewer camera inspections
  • Septic services
  • Gas line services
  • Sump pumps
  • Water treatment systems

Basement moisture is a common issue throughout Akron, especially after heavy storms and spring thaw. We also work in many Summit County homes where hard water buildup has slowly reduced water pressure and shortened the life of fixtures and water heaters.

Electrical Upgrades & Repairs in Akron, OH

Many Akron electrical systems were built long before modern households started running multiple TVs, gaming systems, large HVAC equipment, kitchen appliances, and EV chargers at the same time. It is common for us to find older panels and overloaded circuits in homes that have gone through years of remodeling. Electrical services we handle throughout Akron include:

  • Electrical repair
  • Electrical installation
  • Electrical inspections
  • Whole-home generators
  • Indoor and outdoor lighting
  • Electrical panel upgrades
  • Surge protection
  • EV charger installation
  • Electrical wiring and rewiring

We also see a lot of older homes with partial rewiring jobs where sections of original wiring are still mixed with newer upgrades. If lights flicker, breakers trip regularly, or outlets feel warm, the electrical system should be inspected before the issue becomes more serious.

Why So Many Akron Homeowners Use Blind & Sons

Blind & Sons has worked throughout the Akron area for years, and this is one of the busiest service regions on our schedule. Our technicians already know the differences between homes near downtown Akron, older neighborhoods around Firestone Park, and residential developments stretching toward Green and Fairlawn.

Akron homeowners continue calling Blind & Sons because we provide:

  • Fast scheduling and responsive service
  • Experienced HVAC, plumbing, and electrical technicians
  • Emergency repair availability
  • Financing options on qualifying systems
  • Full-service support for older and newer homes
  • Straightforward recommendations without pressure

A technician who understands Akron housing stock can usually spot problems much faster. That matters when you are dealing with older ductwork, aging plumbing systems, or electrical setups that have been modified multiple times over the years.

What Customers Are Saying

“My furnace went out and Deontae Guthrie was the technician that came out and replaced it.” He was friendly, knowledgeable, and did a great job. The pricing for the replacement was much more reasonable then I thought, plus Blind and Sons offers fantastic financing options. I’m glad my house is warm again and I will be using this company for any future issues.

Jake T. (Akron Area, Customer) – Rated 5/5 Stars

“We had JoJo install our new furnace and he did an excellent job.” He was very knowledgeable about the job he was doing and also very personable! Extremely nice guy! We will definitely be going back to Blind and Sons! Their price was very reasonable and even well below the quote from a few other competitors.

Janice P. (Summit County, Customer) – Rated 5/5 Stars

“Looks like a new furnace.” Shea and his partner let me know when they were enroute and arrived soon after. They were great guys to work with, showed respect for my home, did a great job with the duct repair, and totally cleaned up. Would recommend this team 100%.

Susan M. (Akron, Customer) – Rated 5/5 Stars

Schedule Service in Akron Today

If something in your Akron home is not working the way it should, Blind & Sons is ready to help. Our technicians already work throughout the city every week handling furnace failures, AC problems, sewer backups, electrical upgrades, and airflow issues in homes just like yours.

Whether you live near Portage Lakes, Highland Square, Ellet, or farther out toward Green and Fairlawn, you can count on experienced technicians who understand the common problems found throughout Akron homes. Call (330) 753-7711 or contact Blind & Sons online today to schedule heating, cooling, plumbing, or electrical service in Akron.

Recent Jobs and Reviews in Akron, OH

Job Locations and Reviews

Diagnosed dual capacitor with compressor side reading out of acceptable range, which could cause premature compressor failure and eventual loss of cooling. Replaced defective dual run capacitor with truck stock unit to restore proper electrical specifications and prevent equipment damage. System tested and verified operating within normal parameters following repair.
Diagnosed dual capacitor with compressor side reading out of acceptable range, which could cause premature compressor failure and eventual loss of cooling. Replaced defective dual run capacitor with truck stock unit to restore proper electrical specifications and prevent equipment damage. System tested and verified operating within normal parameters following repair.
Taylor F.
Taylor F. Checked in
Diagnosed dual capacitor with compressor side reading out of acceptable range, which could cause premature compressor failure and eventual loss of cooling. Replaced defective dual run capacitor with truck stock unit to restore proper electrical specifications and prevent equipment damage. System tested and verified operating within normal parameters following repair.
Akron, OH 44312
Completed scheduled BS-MVP cooling maintenance visit on 9-year-old air conditioning system. Removed and inspected multiple heavily soiled accordion-style pleated air filters showing significant dust and dirt accumulation. Performed electrical diagnostics using clamp meter on outdoor condensing unit, recording amperage reading of 55.9 amps. System evaluated and maintenance procedures completed per recurring service protocol.
Completed scheduled BS-MVP cooling maintenance visit on 9-year-old air conditioning system. Removed and inspected multiple heavily soiled accordion-style pleated air filters showing significant dust and dirt accumulation. Performed electrical diagnostics using clamp meter on outdoor condensing unit, recording amperage reading of 55.9 amps. System evaluated and maintenance procedures completed per recurring service protocol.
Colton D.
Colton D. Checked in
Completed scheduled BS-MVP cooling maintenance visit on 9-year-old air conditioning system. Removed and inspected multiple heavily soiled accordion-style pleated air filters showing significant dust and dirt accumulation. Performed electrical diagnostics using clamp meter on outdoor condensing unit, recording amperage reading of 55.9 amps. System evaluated and maintenance procedures completed per recurring service protocol.
Akron, OH 44313
Akron, OH - Performed video camera inspection of drain line to investigate suspected pipe damage and source of drain fly infestation in basement area. Camera inspection revealed plumbing conditions beneath kitchen sink area, documenting pipe connections and potential leak points for further assessment and repair recommendations.
Karl M.
Karl M. Checked in
Performed video camera inspection of drain line to investigate suspected pipe damage and source of drain fly infestation in basement area. Camera inspection revealed plumbing conditions beneath kitchen sink area, documenting pipe connections and potential leak points for further assessment and repair recommendations.
Akron, OH 44333
# HVAC Service Summary

Performed preventive maintenance on 8-year-old air conditioning system. Upon inspection, discovered failed capacitor with severe corrosion and thermal damage to housing and surrounding components. Replaced defective capacitor with new Totaline P291-4054R5 dual-run capacitor rated for 370/440VAC operation. Cleaned debris and corrosion from capacitor mounting area, verified all electrical connections, and tested system operation to confirm proper functionality.

# Detailed Service Description

Responded to service call for existing customer's outdoor air conditioning unit, approximately 8 years old and originally installed by our company. Arrived on-site and performed comprehensive system inspection of the condensing unit.

During visual inspection, identified a severely failed run capacitor exhibiting extensive corrosion, thermal damage, and burnt organic debris accumulation on top of the component and surrounding housing. The capacitor showed clear signs of elec
# HVAC Service Summary

Performed preventive maintenance on 8-year-old air conditioning system. Upon inspection, discovered failed capacitor with severe corrosion and thermal damage to housing and surrounding components. Replaced defective capacitor with new Totaline P291-4054R5 dual-run capacitor rated for 370/440VAC operation. Cleaned debris and corrosion from capacitor mounting area, verified all electrical connections, and tested system operation to confirm proper functionality.

# Detailed Service Description

Responded to service call for existing customer's outdoor air conditioning unit, approximately 8 years old and originally installed by our company. Arrived on-site and performed comprehensive system inspection of the condensing unit.

During visual inspection, identified a severely failed run capacitor exhibiting extensive corrosion, thermal damage, and burnt organic debris accumulation on top of the component and surrounding housing. The capacitor showed clear signs of elec
Jibreel H.
Jibreel H. Checked in
# HVAC Service Summary Performed preventive maintenance on 8-year-old air conditioning system. Upon inspection, discovered failed capacitor with severe corrosion and thermal damage to housing and surrounding components. Replaced defective capacitor with new Totaline P291-4054R5 dual-run capacitor rated for 370/440VAC operation. Cleaned debris and corrosion from capacitor mounting area, verified all electrical connections, and tested system operation to confirm proper functionality. # Detailed Service Description Responded to service call for existing customer's outdoor air conditioning unit, approximately 8 years old and originally installed by our company. Arrived on-site and performed comprehensive system inspection of the condensing unit. During visual inspection, identified a severely failed run capacitor exhibiting extensive corrosion, thermal damage, and burnt organic debris accumulation on top of the component and surrounding housing. The capacitor showed clear signs of elec
Akron, OH 44313
Akron, OH - Responded to no cooling complaint on residential HVAC system. Upon arrival, accessed furnace unit in utility room and performed diagnostic evaluation of system components including blower motor, electrical connections, and associated controls. Opened access panel to inspect internal components and identify cause of cooling failure on aging 10+ year old unit.
William S.
William S. Checked in
Responded to no cooling complaint on residential HVAC system. Upon arrival, accessed furnace unit in utility room and performed diagnostic evaluation of system components including blower motor, electrical connections, and associated controls. Opened access panel to inspect internal components and identify cause of cooling failure on aging 10+ year old unit.
Akron, OH 44321
Responded to a hall bathroom drain blockage affecting a separate branch line in the drainage system. Upon arrival, found several inches of standing water in the bathtub and discolored water present in fixtures due to drain backup. The back pressure from the blocked line had compromised the toilet's wax seal, causing water to leak onto the bathroom floor with potential seepage into the crawl space below. 

Evacuated standing water from both the bathtub and toilet bowl to prepare for drain clearing operations. Removed and set aside the toilet to access the drain line directly. Deployed mechanical snake through the exposed drain opening to locate and clear the obstruction in the branch line. Successfully broke through the blockage and restored proper drainage flow throughout the affected branch line. 

Verified clearance by running water through the system and confirming adequate flow with no backup. Reinstalled the toilet with a new wax ring seal from truck stock to ensure proper waterti
Responded to a hall bathroom drain blockage affecting a separate branch line in the drainage system. Upon arrival, found several inches of standing water in the bathtub and discolored water present in fixtures due to drain backup. The back pressure from the blocked line had compromised the toilet's wax seal, causing water to leak onto the bathroom floor with potential seepage into the crawl space below. 

Evacuated standing water from both the bathtub and toilet bowl to prepare for drain clearing operations. Removed and set aside the toilet to access the drain line directly. Deployed mechanical snake through the exposed drain opening to locate and clear the obstruction in the branch line. Successfully broke through the blockage and restored proper drainage flow throughout the affected branch line. 

Verified clearance by running water through the system and confirming adequate flow with no backup. Reinstalled the toilet with a new wax ring seal from truck stock to ensure proper waterti
Mark W.
Mark W. Checked in
Responded to a hall bathroom drain blockage affecting a separate branch line in the drainage system. Upon arrival, found several inches of standing water in the bathtub and discolored water present in fixtures due to drain backup. The back pressure from the blocked line had compromised the toilet's wax seal, causing water to leak onto the bathroom floor with potential seepage into the crawl space below. Evacuated standing water from both the bathtub and toilet bowl to prepare for drain clearing operations. Removed and set aside the toilet to access the drain line directly. Deployed mechanical snake through the exposed drain opening to locate and clear the obstruction in the branch line. Successfully broke through the blockage and restored proper drainage flow throughout the affected branch line. Verified clearance by running water through the system and confirming adequate flow with no backup. Reinstalled the toilet with a new wax ring seal from truck stock to ensure proper waterti
Akron, OH 44313
Completed MVP recurring cooling maintenance visit on residential HVAC system. Performed comprehensive inspection of both indoor evaporator coil unit and outdoor condensing unit. Evaporator coil exhibited significant accumulation of dust, dirt, and debris throughout aluminum fins, restricting airflow and reducing system efficiency. Documented condition of refrigerant lines showing age-related oxidation on bare copper sections. Verified all electrical connections, wiring harnesses, and control components including capacitor, compressor motor, and control board. All electrical components found secure with proper connections maintained. Outdoor unit access panel opened for full inspection of compressor, electrical components, and refrigerant line connections. System operational at time of service with all major components functioning. Photographic documentation captured for maintenance records showing current condition of evaporator coil contamination and overall system status.
Completed MVP recurring cooling maintenance visit on residential HVAC system. Performed comprehensive inspection of both indoor evaporator coil unit and outdoor condensing unit. Evaporator coil exhibited significant accumulation of dust, dirt, and debris throughout aluminum fins, restricting airflow and reducing system efficiency. Documented condition of refrigerant lines showing age-related oxidation on bare copper sections. Verified all electrical connections, wiring harnesses, and control components including capacitor, compressor motor, and control board. All electrical components found secure with proper connections maintained. Outdoor unit access panel opened for full inspection of compressor, electrical components, and refrigerant line connections. System operational at time of service with all major components functioning. Photographic documentation captured for maintenance records showing current condition of evaporator coil contamination and overall system status.
Taylor F.
Taylor F. Checked in
Completed MVP recurring cooling maintenance visit on residential HVAC system. Performed comprehensive inspection of both indoor evaporator coil unit and outdoor condensing unit. Evaporator coil exhibited significant accumulation of dust, dirt, and debris throughout aluminum fins, restricting airflow and reducing system efficiency. Documented condition of refrigerant lines showing age-related oxidation on bare copper sections. Verified all electrical connections, wiring harnesses, and control components including capacitor, compressor motor, and control board. All electrical components found secure with proper connections maintained. Outdoor unit access panel opened for full inspection of compressor, electrical components, and refrigerant line connections. System operational at time of service with all major components functioning. Photographic documentation captured for maintenance records showing current condition of evaporator coil contamination and overall system status.
Akron, OH 44312
Conducted comprehensive HVAC system evaluation for replacement estimate on 16-year-old York furnace installation. Assessed existing equipment configuration including furnace unit, PVC drainage and ventilation systems, ductwork connections, electrical components, and condensate management setup in basement utility space. Documented current system condition through photographic records and provided customer with replacement options for aging heating system.
Conducted comprehensive HVAC system evaluation for replacement estimate on 16-year-old York furnace installation. Assessed existing equipment configuration including furnace unit, PVC drainage and ventilation systems, ductwork connections, electrical components, and condensate management setup in basement utility space. Documented current system condition through photographic records and provided customer with replacement options for aging heating system.
Dave T.
Dave T. Checked in
Conducted comprehensive HVAC system evaluation for replacement estimate on 16-year-old York furnace installation. Assessed existing equipment configuration including furnace unit, PVC drainage and ventilation systems, ductwork connections, electrical components, and condensate management setup in basement utility space. Documented current system condition through photographic records and provided customer with replacement options for aging heating system.
Akron, OH 44333
Completed comprehensive electrical repairs including troubleshooting and resolving a breaker trip issue affecting lighting and outlets near the front door entrance. Inspected recessed can lights in the front porch ceiling area and traced circuits through attic space to identify the fault. Installed customer-supplied three-prong dryer outlet to code specifications. Replaced two outlets in the kitchen two-gang box with new receptacles. Extended circuit from master bedroom outlets to install a new outlet in the master closet for improved accessibility. Removed defective faceless GFCI receptacle in master bathroom and installed standard GFCI device with proper faceplate. All work performed with helper assistance using extension ladder for overhead access, ensuring all circuits were tested and operational upon completion.
Completed comprehensive electrical repairs including troubleshooting and resolving a breaker trip issue affecting lighting and outlets near the front door entrance. Inspected recessed can lights in the front porch ceiling area and traced circuits through attic space to identify the fault. Installed customer-supplied three-prong dryer outlet to code specifications. Replaced two outlets in the kitchen two-gang box with new receptacles. Extended circuit from master bedroom outlets to install a new outlet in the master closet for improved accessibility. Removed defective faceless GFCI receptacle in master bathroom and installed standard GFCI device with proper faceplate. All work performed with helper assistance using extension ladder for overhead access, ensuring all circuits were tested and operational upon completion.
Landon M.
Landon M. Checked in
Completed comprehensive electrical repairs including troubleshooting and resolving a breaker trip issue affecting lighting and outlets near the front door entrance. Inspected recessed can lights in the front porch ceiling area and traced circuits through attic space to identify the fault. Installed customer-supplied three-prong dryer outlet to code specifications. Replaced two outlets in the kitchen two-gang box with new receptacles. Extended circuit from master bedroom outlets to install a new outlet in the master closet for improved accessibility. Removed defective faceless GFCI receptacle in master bathroom and installed standard GFCI device with proper faceplate. All work performed with helper assistance using extension ladder for overhead access, ensuring all circuits were tested and operational upon completion.
Akron, OH 44333
Completed MVP cooling maintenance visit on Lennox outdoor condensing unit. Performed standard system inspection, verified refrigerant line temperatures at 74°F on suction line, confirmed unit operational status, and documented equipment condition. All components found operating within normal parameters with no immediate service needs identified.
Completed MVP cooling maintenance visit on Lennox outdoor condensing unit. Performed standard system inspection, verified refrigerant line temperatures at 74°F on suction line, confirmed unit operational status, and documented equipment condition. All components found operating within normal parameters with no immediate service needs identified.
Taylor F.
Taylor F. Checked in
Completed MVP cooling maintenance visit on Lennox outdoor condensing unit. Performed standard system inspection, verified refrigerant line temperatures at 74°F on suction line, confirmed unit operational status, and documented equipment condition. All components found operating within normal parameters with no immediate service needs identified.
Akron, OH 44312
Completed scheduled MVP cooling maintenance visit on residential air conditioning system. Performed comprehensive inspection of outdoor condensing unit, verified proper operation of all components, checked electrical connections at disconnect box and conduit assembly, and documented equipment condition through photographic records. Unit found operating within normal parameters with no immediate service needs identified.
Completed scheduled MVP cooling maintenance visit on residential air conditioning system. Performed comprehensive inspection of outdoor condensing unit, verified proper operation of all components, checked electrical connections at disconnect box and conduit assembly, and documented equipment condition through photographic records. Unit found operating within normal parameters with no immediate service needs identified.
Jibreel H.
Jibreel H. Checked in
Completed scheduled MVP cooling maintenance visit on residential air conditioning system. Performed comprehensive inspection of outdoor condensing unit, verified proper operation of all components, checked electrical connections at disconnect box and conduit assembly, and documented equipment condition through photographic records. Unit found operating within normal parameters with no immediate service needs identified.
Akron, OH 44313
Performed estimate on 42+ year old Hydro Therm gas-fired boiler serving baseboard heating system. Unit exhibits extensive deterioration including rusted-out components, heavily corroded internal mechanisms, and degraded manufacturer plates. Boiler shows significant age-related wear with gummed-up controls and compromised structural integrity. Documented equipment condition with photographs showing weathered housing, oxidized copper piping, deteriorated flue connections, and overall system decline. Provided quote for boiler replacement due to unit being beyond serviceable life expectancy.
Performed estimate on 42+ year old Hydro Therm gas-fired boiler serving baseboard heating system. Unit exhibits extensive deterioration including rusted-out components, heavily corroded internal mechanisms, and degraded manufacturer plates. Boiler shows significant age-related wear with gummed-up controls and compromised structural integrity. Documented equipment condition with photographs showing weathered housing, oxidized copper piping, deteriorated flue connections, and overall system decline. Provided quote for boiler replacement due to unit being beyond serviceable life expectancy.
Dave T.
Dave T. Checked in
Performed estimate on 42+ year old Hydro Therm gas-fired boiler serving baseboard heating system. Unit exhibits extensive deterioration including rusted-out components, heavily corroded internal mechanisms, and degraded manufacturer plates. Boiler shows significant age-related wear with gummed-up controls and compromised structural integrity. Documented equipment condition with photographs showing weathered housing, oxidized copper piping, deteriorated flue connections, and overall system decline. Provided quote for boiler replacement due to unit being beyond serviceable life expectancy.
Akron, OH 44312
Akron, OH - Responded to plumbing service call for malfunctioning toilet in downstairs apartment. Upon inspection, removed tank lid and assessed internal components including flush valve assembly with red cap, fill valve mechanism, and connecting hardware. Identified issue with toilet operation, performed necessary repairs to restore proper flushing function, and verified all tank components were operating correctly before completing service.
Isaiah H.
Isaiah H. Checked in
Responded to plumbing service call for malfunctioning toilet in downstairs apartment. Upon inspection, removed tank lid and assessed internal components including flush valve assembly with red cap, fill valve mechanism, and connecting hardware. Identified issue with toilet operation, performed necessary repairs to restore proper flushing function, and verified all tank components were operating correctly before completing service.
Akron, OH 44302
Completed installation of interior light fixtures and exterior walkway lighting for residential property. Work included mounting new fixture in interior ceiling space with proper wiring connections through access hole, and installing outdoor walkway lights on exterior of home. Verified all electrical connections were secure, tested fixtures for proper operation, and ensured installations met code requirements for both indoor and outdoor applications.
Completed installation of interior light fixtures and exterior walkway lighting for residential property. Work included mounting new fixture in interior ceiling space with proper wiring connections through access hole, and installing outdoor walkway lights on exterior of home. Verified all electrical connections were secure, tested fixtures for proper operation, and ensured installations met code requirements for both indoor and outdoor applications.
Austin B.
Austin B. Checked in
Completed installation of interior light fixtures and exterior walkway lighting for residential property. Work included mounting new fixture in interior ceiling space with proper wiring connections through access hole, and installing outdoor walkway lights on exterior of home. Verified all electrical connections were secure, tested fixtures for proper operation, and ensured installations met code requirements for both indoor and outdoor applications.
Akron, OH 44321
Completed seasonal tune-up on 7-year-old residential air conditioning system. Inspected indoor AprilAire humidifier unit and replaced heavily soiled accordion-style air filter showing significant dust accumulation. Accessed outdoor condensing unit, removed top panel, and identified dirty condenser coil requiring cleaning due to debris buildup from outdoor exposure.
Completed seasonal tune-up on 7-year-old residential air conditioning system. Inspected indoor AprilAire humidifier unit and replaced heavily soiled accordion-style air filter showing significant dust accumulation. Accessed outdoor condensing unit, removed top panel, and identified dirty condenser coil requiring cleaning due to debris buildup from outdoor exposure.
Matthew F.
Matthew F. Checked in
Completed seasonal tune-up on 7-year-old residential air conditioning system. Inspected indoor AprilAire humidifier unit and replaced heavily soiled accordion-style air filter showing significant dust accumulation. Accessed outdoor condensing unit, removed top panel, and identified dirty condenser coil requiring cleaning due to debris buildup from outdoor exposure.
Akron, OH 44333
Responded to service call for 18-year-old Kenmore Power Miser water heater with pilot light failure. Upon arrival, pilot light would not remain lit and only flashed intermittently, indicating thermocouple or gas valve issues typical of aged units. Inspected burner assembly, thermocouple positioning, and gas control valve on this residential basement installation. Given the advanced age of the unit and the nature of the pilot failure, recommended replacement rather than repair due to diminished reliability and efficiency of components approaching end of service life. Documented existing installation configuration including copper supply lines, compression fittings, shut-off valves, and venting system for future reference.
Responded to service call for 18-year-old Kenmore Power Miser water heater with pilot light failure. Upon arrival, pilot light would not remain lit and only flashed intermittently, indicating thermocouple or gas valve issues typical of aged units. Inspected burner assembly, thermocouple positioning, and gas control valve on this residential basement installation. Given the advanced age of the unit and the nature of the pilot failure, recommended replacement rather than repair due to diminished reliability and efficiency of components approaching end of service life. Documented existing installation configuration including copper supply lines, compression fittings, shut-off valves, and venting system for future reference.
Travis B.
Travis B. Checked in
Responded to service call for 18-year-old Kenmore Power Miser water heater with pilot light failure. Upon arrival, pilot light would not remain lit and only flashed intermittently, indicating thermocouple or gas valve issues typical of aged units. Inspected burner assembly, thermocouple positioning, and gas control valve on this residential basement installation. Given the advanced age of the unit and the nature of the pilot failure, recommended replacement rather than repair due to diminished reliability and efficiency of components approaching end of service life. Documented existing installation configuration including copper supply lines, compression fittings, shut-off valves, and venting system for future reference.
Akron, OH 44320
Completed AC tune-up service including comprehensive system inspection and performance verification. Accessed furnace cabinet to inspect internal components, electrical connections, blower motor assembly, and control mechanisms. All wiring connections examined and found secure. Installed complimentary carbon monoxide detector as part of seasonal maintenance package. System operating within normal parameters upon completion.
Completed AC tune-up service including comprehensive system inspection and performance verification. Accessed furnace cabinet to inspect internal components, electrical connections, blower motor assembly, and control mechanisms. All wiring connections examined and found secure. Installed complimentary carbon monoxide detector as part of seasonal maintenance package. System operating within normal parameters upon completion.
Jibreel H.
Jibreel H. Checked in
Completed AC tune-up service including comprehensive system inspection and performance verification. Accessed furnace cabinet to inspect internal components, electrical connections, blower motor assembly, and control mechanisms. All wiring connections examined and found secure. Installed complimentary carbon monoxide detector as part of seasonal maintenance package. System operating within normal parameters upon completion.
Akron, OH 44333
Replaced outdoor spigot as requested by customer. Removed old hose bib fixture and installed new frost-free outdoor faucet, ensuring proper sealing and secure mounting to exterior wall. Tested water flow and verified no leaks at connection points upon completion.
Replaced outdoor spigot as requested by customer. Removed old hose bib fixture and installed new frost-free outdoor faucet, ensuring proper sealing and secure mounting to exterior wall. Tested water flow and verified no leaks at connection points upon completion.
Isaiah H.
Isaiah H. Checked in
Replaced outdoor spigot as requested by customer. Removed old hose bib fixture and installed new frost-free outdoor faucet, ensuring proper sealing and secure mounting to exterior wall. Tested water flow and verified no leaks at connection points upon completion.
Akron, OH 44313
Responded to service call for two leaking outdoor spigots on 30-year-old residential property. Upon inspection, identified active leaks at both exterior hose bibs. Accessed interior plumbing connections through utility closet and crawl space area to assess supply lines and shut-off valves. Documented existing conditions showing black supply piping and mounting configuration in confined mechanical space. Completed diagnostic evaluation of both spigot assemblies and associated plumbing infrastructure to determine repair requirements.
Responded to service call for two leaking outdoor spigots on 30-year-old residential property. Upon inspection, identified active leaks at both exterior hose bibs. Accessed interior plumbing connections through utility closet and crawl space area to assess supply lines and shut-off valves. Documented existing conditions showing black supply piping and mounting configuration in confined mechanical space. Completed diagnostic evaluation of both spigot assemblies and associated plumbing infrastructure to determine repair requirements.
James P.
James P. Checked in
Responded to service call for two leaking outdoor spigots on 30-year-old residential property. Upon inspection, identified active leaks at both exterior hose bibs. Accessed interior plumbing connections through utility closet and crawl space area to assess supply lines and shut-off valves. Documented existing conditions showing black supply piping and mounting configuration in confined mechanical space. Completed diagnostic evaluation of both spigot assemblies and associated plumbing infrastructure to determine repair requirements.
Akron, OH 44319
Completed MVP cooling maintenance visit on residential HVAC system. Performed standard preventive maintenance inspection of outdoor condensing unit, verifying proper operation of electrical components including contactor, capacitor, and associated wiring connections. All electrical connections found secure with no visible signs of deterioration or overheating. Documented equipment condition through photographic records showing electrical disconnect box and outdoor unit components in serviceable condition.
Completed MVP cooling maintenance visit on residential HVAC system. Performed standard preventive maintenance inspection of outdoor condensing unit, verifying proper operation of electrical components including contactor, capacitor, and associated wiring connections. All electrical connections found secure with no visible signs of deterioration or overheating. Documented equipment condition through photographic records showing electrical disconnect box and outdoor unit components in serviceable condition.
Jibreel H.
Jibreel H. Checked in
Completed MVP cooling maintenance visit on residential HVAC system. Performed standard preventive maintenance inspection of outdoor condensing unit, verifying proper operation of electrical components including contactor, capacitor, and associated wiring connections. All electrical connections found secure with no visible signs of deterioration or overheating. Documented equipment condition through photographic records showing electrical disconnect box and outdoor unit components in serviceable condition.
Akron, OH 44314

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image