Schedule Service

Heating, Cooling, Plumbing & Electrical Repair in Akron, OH

Akron is filled with older neighborhoods where home systems have been pieced together over decades. From the century-old homes near Highland Square and North Hill to post-war houses around Firestone Park and Ellet, many homeowners here are dealing with aging ductwork, outdated breaker panels, worn sewer lines, and HVAC systems that were never designed for today’s demand. Blind & Sons is in Akron every week handling these exact kinds of problems across areas near Route 8, Arlington Road, Market Street, and the neighborhoods surrounding Portage Lakes.

A furnace breakdown in January or a flooded basement after heavy rain is not something Akron homeowners can put off. If you need help with heating, cooling, plumbing, or electrical work, call 330-362-9232 or contact Blind & Sons online to schedule service with a team that already knows the layouts, infrastructure, and common repair issues found throughout Akron homes.

Working in Akron Homes Every Day4

Akron homes tell you their age the second you walk into them. Some still have original plaster walls and older boiler systems. Others have newer additions connected to ductwork that was never redesigned to support the extra square footage.

We spend a lot of time in neighborhoods near West Exchange Street, Merriman Valley, Goodyear Heights, and Springfield Township where systems have been repaired, expanded, and modified over generations of ownership. In many homes, comfort problems are not caused by one failed part. They come from years of small upgrades layered onto older systems.

AC Repair & Cooling Systems in Akron, OH

Cooling complaints across Akron usually start with airflow. Older homes throughout the city often struggle to move enough conditioned air upstairs, especially during humid stretches in July and August. We also see a lot of enclosed porches, converted attics, and home additions that were added without properly updating the cooling system.

Air conditioning and cooling services we handle throughout Akron include:

In neighborhoods with mature trees and older insulation, it is common for certain rooms to stay warmer than the rest of the house no matter how long the AC runs. Our technicians look at the full system, including duct layout, airflow balance, and equipment sizing, instead of just replacing parts and hoping the issue goes away.

Indoor Air Quality Solutions in Akron, OH

Many Akron electrical systems were built long before modern households started running multiple TVs, gaming systems, large HVAC equipment, kitchen appliances, and EV chargers at the same time. It is common for us to find older panels and overloaded circuits in homes that have gone through years of remodeling. Electrical services we handle throughout Akron include:

  • Electrical repair
  • Electrical installation
  • Electrical inspections
  • Whole-home generators
  • Indoor and outdoor lighting
  • Electrical panel upgrades
  • Surge protection
  • EV charger installation
  • Electrical wiring and rewiring

We also see a lot of older homes with partial rewiring jobs where sections of original wiring are still mixed with newer upgrades. If lights flicker, breakers trip regularly, or outlets feel warm, the electrical system should be inspected before the issue becomes more serious.

Furnace & Heating Repair in Akron, OH

Older Akron homes place a heavy demand on heating equipment during Northeast Ohio winters. We regularly work on furnaces and boilers that have been running for decades, especially in homes built before the 1970s where airflow and insulation standards were very different from today. Heating services available throughout Akron include:

  • Emergency heating repair
  • Heating maintenance
  • Furnace repair and replacement
  • Boiler repair and installation
  • Heat pump services
  • Ductless HVAC systems
  • Hybrid heating systems

Some of the most common calls we see involve uneven temperatures between floors, noisy ductwork, short cycling furnaces, and rooms that never seem to fully warm up. In a lot of Akron homes, those issues trace back to aging duct systems or previous remodels that changed airflow patterns inside the house.

Plumbing Repair & Drain Services in Akron, OH

Plumbing issues in Akron vary from neighborhood to neighborhood. In older parts of the city, we frequently run into aging drain lines, sewer backups, and galvanized plumbing that has narrowed over time. In newer residential areas, sump pump failures and water pressure issues are more common. Plumbing services we provide throughout Akron include:

  • Plumbing repair
  • Plumbing maintenance
  • Drain cleaning
  • Water heater repair and installation
  • Plumbing fixtures
  • Sewer services
  • Sewer camera inspections
  • Septic services
  • Gas line services
  • Sump pumps
  • Water treatment systems

Basement moisture is a common issue throughout Akron, especially after heavy storms and spring thaw. We also work in many Summit County homes where hard water buildup has slowly reduced water pressure and shortened the life of fixtures and water heaters.

Electrical Upgrades & Repairs in Akron, OH

Many Akron electrical systems were built long before modern households started running multiple TVs, gaming systems, large HVAC equipment, kitchen appliances, and EV chargers at the same time. It is common for us to find older panels and overloaded circuits in homes that have gone through years of remodeling. Electrical services we handle throughout Akron include:

  • Electrical repair
  • Electrical installation
  • Electrical inspections
  • Whole-home generators
  • Indoor and outdoor lighting
  • Electrical panel upgrades
  • Surge protection
  • EV charger installation
  • Electrical wiring and rewiring

We also see a lot of older homes with partial rewiring jobs where sections of original wiring are still mixed with newer upgrades. If lights flicker, breakers trip regularly, or outlets feel warm, the electrical system should be inspected before the issue becomes more serious.

Why So Many Akron Homeowners Use Blind & Sons

Blind & Sons has worked throughout the Akron area for years, and this is one of the busiest service regions on our schedule. Our technicians already know the differences between homes near downtown Akron, older neighborhoods around Firestone Park, and residential developments stretching toward Green and Fairlawn.

Akron homeowners continue calling Blind & Sons because we provide:

  • Fast scheduling and responsive service
  • Experienced HVAC, plumbing, and electrical technicians
  • Emergency repair availability
  • Financing options on qualifying systems
  • Full-service support for older and newer homes
  • Straightforward recommendations without pressure

A technician who understands Akron housing stock can usually spot problems much faster. That matters when you are dealing with older ductwork, aging plumbing systems, or electrical setups that have been modified multiple times over the years.

What Customers Are Saying

“My furnace went out and Deontae Guthrie was the technician that came out and replaced it.” He was friendly, knowledgeable, and did a great job. The pricing for the replacement was much more reasonable then I thought, plus Blind and Sons offers fantastic financing options. I’m glad my house is warm again and I will be using this company for any future issues.

Jake T. (Akron Area, Customer) – Rated 5/5 Stars

“We had JoJo install our new furnace and he did an excellent job.” He was very knowledgeable about the job he was doing and also very personable! Extremely nice guy! We will definitely be going back to Blind and Sons! Their price was very reasonable and even well below the quote from a few other competitors.

Janice P. (Summit County, Customer) – Rated 5/5 Stars

“Looks like a new furnace.” Shea and his partner let me know when they were enroute and arrived soon after. They were great guys to work with, showed respect for my home, did a great job with the duct repair, and totally cleaned up. Would recommend this team 100%.

Susan M. (Akron, Customer) – Rated 5/5 Stars

Schedule Service in Akron Today

If something in your Akron home is not working the way it should, Blind & Sons is ready to help. Our technicians already work throughout the city every week handling furnace failures, AC problems, sewer backups, electrical upgrades, and airflow issues in homes just like yours.

Whether you live near Portage Lakes, Highland Square, Ellet, or farther out toward Green and Fairlawn, you can count on experienced technicians who understand the common problems found throughout Akron homes. Call 330-362-9232 or contact Blind & Sons online today to schedule heating, cooling, plumbing, or electrical service in Akron.

Recent Jobs and Reviews in Akron, OH

Akron, OH at a glance

Blind and Sons has completed 20 jobs in Akron, OH in October 2026.

The most recent job was on October 19, 2026.

Blind and Sons has completed 4,177 jobs in Akron, OH in the last 12 months.

Job Locations and Reviews

Responded to a no-heat call on a 2-year-old natural gas furnace and inspected the cabinet interior. Found significant rust and corrosion around the drain hose and pressure tube penetrations in the cabinet floor, along with deteriorated, rust-stained cabinet insulation, indicating a condensate or moisture leak that likely caused the heat failure. Recommend further repair of the condensate drain system and cabinet corrosion to restore safe, reliable operation.
Responded to a no-heat call on a 2-year-old natural gas furnace and inspected the cabinet interior. Found significant rust and corrosion around the drain hose and pressure tube penetrations in the cabinet floor, along with deteriorated, rust-stained cabinet insulation, indicating a condensate or moisture leak that likely caused the heat failure. Recommend further repair of the condensate drain system and cabinet corrosion to restore safe, reliable operation.
Derrick M.
Derrick M. Checked in
Responded to a no-heat call on a 2-year-old natural gas furnace and inspected the cabinet interior. Found significant rust and corrosion around the drain hose and pressure tube penetrations in the cabinet floor, along with deteriorated, rust-stained cabinet insulation, indicating a condensate or moisture leak that likely caused the heat failure. Recommend further repair of the condensate drain system and cabinet corrosion to restore safe, reliable operation.
Akron, OH 44314
Responded to a no-heat call on a 10+ year old gas-fired furnace and removed the front access panel to inspect the burner assembly, gas valve, controls, and wiring, noting rust and corrosion near the burner compartment. Used a borescope to inspect the heat exchanger and internal ductwork, which revealed rust-colored staining, debris buildup, and a visible crack or seam separation at a corner joint. Findings were documented with photos for evaluation and repair or replacement recommendations.
Responded to a no-heat call on a 10+ year old gas-fired furnace and removed the front access panel to inspect the burner assembly, gas valve, controls, and wiring, noting rust and corrosion near the burner compartment. Used a borescope to inspect the heat exchanger and internal ductwork, which revealed rust-colored staining, debris buildup, and a visible crack or seam separation at a corner joint. Findings were documented with photos for evaluation and repair or replacement recommendations.
Frank W.
Frank W. Checked in
Responded to a no-heat call on a 10+ year old gas-fired furnace and removed the front access panel to inspect the burner assembly, gas valve, controls, and wiring, noting rust and corrosion near the burner compartment. Used a borescope to inspect the heat exchanger and internal ductwork, which revealed rust-colored staining, debris buildup, and a visible crack or seam separation at a corner joint. Findings were documented with photos for evaluation and repair or replacement recommendations.
Akron, OH 44320
Performed a heating system maintenance inspection, including electrical testing of the furnace control circuit with a true RMS clamp meter and a visual inspection of the gas valve, pressure switch, control board, inducer motor, and wiring, with no signs of corrosion, damage, or loose connections. Inspected the Aprilaire humidifier control, which was found set to the OFF position, and verified the unit and mounting were secure.
Performed a heating system maintenance inspection, including electrical testing of the furnace control circuit with a true RMS clamp meter and a visual inspection of the gas valve, pressure switch, control board, inducer motor, and wiring, with no signs of corrosion, damage, or loose connections. Inspected the Aprilaire humidifier control, which was found set to the OFF position, and verified the unit and mounting were secure.
Jesus M.
Jesus M. Checked in
Performed a heating system maintenance inspection, including electrical testing of the furnace control circuit with a true RMS clamp meter and a visual inspection of the gas valve, pressure switch, control board, inducer motor, and wiring, with no signs of corrosion, damage, or loose connections. Inspected the Aprilaire humidifier control, which was found set to the OFF position, and verified the unit and mounting were secure.
Akron, OH 44333
Responded to a partial loss of power affecting multiple outlets and inspected the circuit for the cause, including an open ceiling fixture box with a capped wire run and a wall switch that had pulled loose from its box. Identified and corrected the faulty connections, secured the switch to its mounting strap, and properly terminated the exposed conductors with wire nuts. Verified continuity and restored power to the affected outlets, confirming proper operation.
Responded to a partial loss of power affecting multiple outlets and inspected the circuit for the cause, including an open ceiling fixture box with a capped wire run and a wall switch that had pulled loose from its box. Identified and corrected the faulty connections, secured the switch to its mounting strap, and properly terminated the exposed conductors with wire nuts. Verified continuity and restored power to the affected outlets, confirming proper operation.
Eric L.
Eric L. Checked in
Responded to a partial loss of power affecting multiple outlets and inspected the circuit for the cause, including an open ceiling fixture box with a capped wire run and a wall switch that had pulled loose from its box. Identified and corrected the faulty connections, secured the switch to its mounting strap, and properly terminated the exposed conductors with wire nuts. Verified continuity and restored power to the affected outlets, confirming proper operation.
Akron, OH 44305
Responded to a no-heat call on a Lennox gas furnace with a history of rollout switch, pressure switch, and heat exchanger repairs, and inspected the burner assembly and flame sensing components. Found dust and debris buildup on the burner compartment surfaces and flame sensor, with no visible cracks, rust, or frost, and documented the condition with photos. Cleaned the affected components and checked furnace operation, and the unit is now producing heat.
Responded to a no-heat call on a Lennox gas furnace with a history of rollout switch, pressure switch, and heat exchanger repairs, and inspected the burner assembly and flame sensing components. Found dust and debris buildup on the burner compartment surfaces and flame sensor, with no visible cracks, rust, or frost, and documented the condition with photos. Cleaned the affected components and checked furnace operation, and the unit is now producing heat.
Frank W.
Frank W. Checked in
Responded to a no-heat call on a Lennox gas furnace with a history of rollout switch, pressure switch, and heat exchanger repairs, and inspected the burner assembly and flame sensing components. Found dust and debris buildup on the burner compartment surfaces and flame sensor, with no visible cracks, rust, or frost, and documented the condition with photos. Cleaned the affected components and checked furnace operation, and the unit is now producing heat.
Akron, OH 44305
Responded to a no-heat call on a 21-year-old Trane gas furnace and inspected the unit, venting, and surrounding components. Observed corrosion on the adjacent copper piping and rust with moisture and mineral residue on the furnace sheet metal, indicating condensation or leakage that should be monitored. Recommended further evaluation of the furnace's remaining service life given its age and the visible deterioration.
Responded to a no-heat call on a 21-year-old Trane gas furnace and inspected the unit, venting, and surrounding components. Observed corrosion on the adjacent copper piping and rust with moisture and mineral residue on the furnace sheet metal, indicating condensation or leakage that should be monitored. Recommended further evaluation of the furnace's remaining service life given its age and the visible deterioration.
Derrick M.
Derrick M. Checked in
Responded to a no-heat call on a 21-year-old Trane gas furnace and inspected the unit, venting, and surrounding components. Observed corrosion on the adjacent copper piping and rust with moisture and mineral residue on the furnace sheet metal, indicating condensation or leakage that should be monitored. Recommended further evaluation of the furnace's remaining service life given its age and the visible deterioration.
Akron, OH 44319
Installed a new water softener with sanitizer system and associated tubing, and cleared the upstairs lavatory drain. Replaced the laundry faucet and installed new washer hookups with shutoff ball valves, and repaired a corroded supply line using copper pro-press fittings.
Installed a new water softener with sanitizer system and associated tubing, and cleared the upstairs lavatory drain. Replaced the laundry faucet and installed new washer hookups with shutoff ball valves, and repaired a corroded supply line using copper pro-press fittings.
Nick L.
Nick L. Checked in
Installed a new water softener with sanitizer system and associated tubing, and cleared the upstairs lavatory drain. Replaced the laundry faucet and installed new washer hookups with shutoff ball valves, and repaired a corroded supply line using copper pro-press fittings.
Akron, OH 44319
Performed scheduled heating maintenance, inspecting the air handler and return plenum and checking the air filter, which showed light dust and grime buildup along the frame edges. Inspected the condensate drain piping and foil-taped ductwork insulation, noting some peeling tape, and examined the flame/ignition rod, which showed light oxidation with no damage or deformation. System components were found in serviceable condition.
Performed scheduled heating maintenance, inspecting the air handler and return plenum and checking the air filter, which showed light dust and grime buildup along the frame edges. Inspected the condensate drain piping and foil-taped ductwork insulation, noting some peeling tape, and examined the flame/ignition rod, which showed light oxidation with no damage or deformation. System components were found in serviceable condition.
Jesus M.
Jesus M. Checked in
Performed scheduled heating maintenance, inspecting the air handler and return plenum and checking the air filter, which showed light dust and grime buildup along the frame edges. Inspected the condensate drain piping and foil-taped ductwork insulation, noting some peeling tape, and examined the flame/ignition rod, which showed light oxidation with no damage or deformation. System components were found in serviceable condition.
Akron, OH 44312
Replaced the existing three-handle stem shower valve in the hallway bathroom with a new Moen single-handle pressure-balancing valve in a chrome finish, accessed through a cut-in wall panel and soldered into the existing copper supply lines. Installed a remodel plate to cover the original valve opening, along with a new shower arm, shower head, and tub spout. Verified secure mounting, proper hot/cold operation, and no leaks at the new connections.
Replaced the existing three-handle stem shower valve in the hallway bathroom with a new Moen single-handle pressure-balancing valve in a chrome finish, accessed through a cut-in wall panel and soldered into the existing copper supply lines. Installed a remodel plate to cover the original valve opening, along with a new shower arm, shower head, and tub spout. Verified secure mounting, proper hot/cold operation, and no leaks at the new connections.
Jared K.
Jared K. Checked in
Replaced the existing three-handle stem shower valve in the hallway bathroom with a new Moen single-handle pressure-balancing valve in a chrome finish, accessed through a cut-in wall panel and soldered into the existing copper supply lines. Installed a remodel plate to cover the original valve opening, along with a new shower arm, shower head, and tub spout. Verified secure mounting, proper hot/cold operation, and no leaks at the new connections.
Akron, OH 44310
Performed scheduled maintenance on a 6-year-old gas-fired furnace, including a visual inspection of the burner assembly, igniter/flame sensor circuit, gas valve, inducer motor, and control board wiring. Verified proper flame characteristics and performed electrical diagnostics with a true RMS clamp meter to confirm correct operating voltage/current on the control circuit. No corrosion, damage, or abnormal conditions were observed, and the unit was left operating normally.
Performed scheduled maintenance on a 6-year-old gas-fired furnace, including a visual inspection of the burner assembly, igniter/flame sensor circuit, gas valve, inducer motor, and control board wiring. Verified proper flame characteristics and performed electrical diagnostics with a true RMS clamp meter to confirm correct operating voltage/current on the control circuit. No corrosion, damage, or abnormal conditions were observed, and the unit was left operating normally.
Jesus M.
Jesus M. Checked in
Performed scheduled maintenance on a 6-year-old gas-fired furnace, including a visual inspection of the burner assembly, igniter/flame sensor circuit, gas valve, inducer motor, and control board wiring. Verified proper flame characteristics and performed electrical diagnostics with a true RMS clamp meter to confirm correct operating voltage/current on the control circuit. No corrosion, damage, or abnormal conditions were observed, and the unit was left operating normally.
Akron, OH 44312
Responded to a no-heat call on a 10-year-old American Standard gas furnace and inspected the burner compartment, gas valve, pressure switch, inducer assembly, and resettable thermal switch, along with the associated wiring and connections. Found no visible damage, frost, or heavy corrosion, though some wiring insulation showed slight discoloration consistent with age; components were documented for further diagnosis and the unit evaluated against recent maintenance and heat exchanger repair history.
Responded to a no-heat call on a 10-year-old American Standard gas furnace and inspected the burner compartment, gas valve, pressure switch, inducer assembly, and resettable thermal switch, along with the associated wiring and connections. Found no visible damage, frost, or heavy corrosion, though some wiring insulation showed slight discoloration consistent with age; components were documented for further diagnosis and the unit evaluated against recent maintenance and heat exchanger repair history.
Jibreel H.
Jibreel H. Checked in
Responded to a no-heat call on a 10-year-old American Standard gas furnace and inspected the burner compartment, gas valve, pressure switch, inducer assembly, and resettable thermal switch, along with the associated wiring and connections. Found no visible damage, frost, or heavy corrosion, though some wiring insulation showed slight discoloration consistent with age; components were documented for further diagnosis and the unit evaluated against recent maintenance and heat exchanger repair history.
Akron, OH 44333
Performed seasonal heating maintenance on a Lennox gas furnace, including inspection of the blower assembly, where the squirrel-cage wheel, motor shaft, collar, and set screw were found intact with only a light dust accumulation and no signs of damage, rust, or imbalance. Visually inspected the furnace cabinet, flue and venting, PVC condensate and drain piping, gas supply piping and union, and associated ductwork and humidifier connections, noting staining and debris at the base of the cabinet that should be monitored for possible leakage or moisture.
Performed seasonal heating maintenance on a Lennox gas furnace, including inspection of the blower assembly, where the squirrel-cage wheel, motor shaft, collar, and set screw were found intact with only a light dust accumulation and no signs of damage, rust, or imbalance. Visually inspected the furnace cabinet, flue and venting, PVC condensate and drain piping, gas supply piping and union, and associated ductwork and humidifier connections, noting staining and debris at the base of the cabinet that should be monitored for possible leakage or moisture.
Daniel
Daniel Checked in
Performed seasonal heating maintenance on a Lennox gas furnace, including inspection of the blower assembly, where the squirrel-cage wheel, motor shaft, collar, and set screw were found intact with only a light dust accumulation and no signs of damage, rust, or imbalance. Visually inspected the furnace cabinet, flue and venting, PVC condensate and drain piping, gas supply piping and union, and associated ductwork and humidifier connections, noting staining and debris at the base of the cabinet that should be monitored for possible leakage or moisture.
Akron, OH 44303
Akron, OH - Performed scheduled heating maintenance on the gas furnace, removing the lower access panel to inspect the burner compartment, gas valve, inducer motor, and wiring connections. Verified the condensate drain line routing to the floor drain and noted moisture residue and staining on the surrounding concrete, indicating the drain area should be monitored for leaks or backup.
John W.
John W. Checked in
Performed scheduled heating maintenance on the gas furnace, removing the lower access panel to inspect the burner compartment, gas valve, inducer motor, and wiring connections. Verified the condensate drain line routing to the floor drain and noted moisture residue and staining on the surrounding concrete, indicating the drain area should be monitored for leaks or backup.
Akron, OH 44320
Inspected the existing two-piece toilet and confirmed hairline cracks in the porcelain bowl base near the closet bolt, indicating a risk of full fracture and leaks. Removed the cracked fixture, exposing the closet flange and bolts, and prepared the installation area for a replacement comfort-height (tall) toilet matching the original style, with the supply line and shutoff valve verified at the wall.
Inspected the existing two-piece toilet and confirmed hairline cracks in the porcelain bowl base near the closet bolt, indicating a risk of full fracture and leaks. Removed the cracked fixture, exposing the closet flange and bolts, and prepared the installation area for a replacement comfort-height (tall) toilet matching the original style, with the supply line and shutoff valve verified at the wall.
Travis B.
Travis B. Checked in
Inspected the existing two-piece toilet and confirmed hairline cracks in the porcelain bowl base near the closet bolt, indicating a risk of full fracture and leaks. Removed the cracked fixture, exposing the closet flange and bolts, and prepared the installation area for a replacement comfort-height (tall) toilet matching the original style, with the supply line and shutoff valve verified at the wall.
Akron, OH 44320
Performed seasonal heating maintenance on the gas furnace, including electrical testing of the blower and inducer circuits with a true RMS clamp meter and inspection of the gas valve, pressure switch, and control wiring for proper connections and operation. Inspected the whole-house humidifier and found the evaporator water panel heavily scaled with mineral deposits and discoloration, indicating the pad is due for cleaning or replacement. The customer elected to renew their recurring maintenance plan during this visit.
Performed seasonal heating maintenance on the gas furnace, including electrical testing of the blower and inducer circuits with a true RMS clamp meter and inspection of the gas valve, pressure switch, and control wiring for proper connections and operation. Inspected the whole-house humidifier and found the evaporator water panel heavily scaled with mineral deposits and discoloration, indicating the pad is due for cleaning or replacement. The customer elected to renew their recurring maintenance plan during this visit.
Jesus M.
Jesus M. Checked in
Performed seasonal heating maintenance on the gas furnace, including electrical testing of the blower and inducer circuits with a true RMS clamp meter and inspection of the gas valve, pressure switch, and control wiring for proper connections and operation. Inspected the whole-house humidifier and found the evaporator water panel heavily scaled with mineral deposits and discoloration, indicating the pad is due for cleaning or replacement. The customer elected to renew their recurring maintenance plan during this visit.
Akron, OH 44313
Akron, OH - Performed a descaling flush on a 10-year-old wall-mounted tankless water heater by isolating the unit at the service valves, circulating a descaling solution through the heat exchanger to dissolve mineral buildup, then flushing with clean water to restore flow and heat transfer efficiency. Reconnected the isolation valves and flexible hoses, restored water and gas supply, and verified proper operation with no leaks at the fittings, gas line, or water connections.
Travis B.
Travis B. Checked in
Performed a descaling flush on a 10-year-old wall-mounted tankless water heater by isolating the unit at the service valves, circulating a descaling solution through the heat exchanger to dissolve mineral buildup, then flushing with clean water to restore flow and heat transfer efficiency. Reconnected the isolation valves and flexible hoses, restored water and gas supply, and verified proper operation with no leaks at the fittings, gas line, or water connections.
Akron, OH 44313
Performed scheduled heating maintenance on a natural gas furnace, including combustion analysis with a Bacharach analyzer (stack temp 92°F, ambient air 54°F, excess air 44.5%, CO 46 ppm) to verify safe, efficient burner operation. Measured amperage draw on the electrical components with a True RMS clamp meter (48.1 reading recorded) to confirm operation within normal parameters, and inspected associated wiring connections. System operating normally at completion.
Performed scheduled heating maintenance on a natural gas furnace, including combustion analysis with a Bacharach analyzer (stack temp 92°F, ambient air 54°F, excess air 44.5%, CO 46 ppm) to verify safe, efficient burner operation. Measured amperage draw on the electrical components with a True RMS clamp meter (48.1 reading recorded) to confirm operation within normal parameters, and inspected associated wiring connections. System operating normally at completion.
Daniel
Daniel Checked in
Performed scheduled heating maintenance on a natural gas furnace, including combustion analysis with a Bacharach analyzer (stack temp 92°F, ambient air 54°F, excess air 44.5%, CO 46 ppm) to verify safe, efficient burner operation. Measured amperage draw on the electrical components with a True RMS clamp meter (48.1 reading recorded) to confirm operation within normal parameters, and inspected associated wiring connections. System operating normally at completion.
Akron, OH 44313
Performed annual heating maintenance on a York upflow gas furnace, including inspection of the control board, relays, capacitor, and low-voltage wiring, as well as the flue venting, condensate drain piping, gas line connections, and Aprilaire humidifier ductwork. Noted loosely routed, cluttered control wiring and mineral residue on the floor at the furnace base, indicating possible condensate or humidifier drain leakage, and recommended further evaluation.
Performed annual heating maintenance on a York upflow gas furnace, including inspection of the control board, relays, capacitor, and low-voltage wiring, as well as the flue venting, condensate drain piping, gas line connections, and Aprilaire humidifier ductwork. Noted loosely routed, cluttered control wiring and mineral residue on the floor at the furnace base, indicating possible condensate or humidifier drain leakage, and recommended further evaluation.
William S.
William S. Checked in
Performed annual heating maintenance on a York upflow gas furnace, including inspection of the control board, relays, capacitor, and low-voltage wiring, as well as the flue venting, condensate drain piping, gas line connections, and Aprilaire humidifier ductwork. Noted loosely routed, cluttered control wiring and mineral residue on the floor at the furnace base, indicating possible condensate or humidifier drain leakage, and recommended further evaluation.
Akron, OH 44312
Akron, OH - Responded to a no-heat call on an older gas furnace of undetermined age that would not stay lit. Inspected the burner compartment, gas valve assembly, and ignition components, performed the necessary service to restore proper ignition and flame retention, and verified the furnace runs through a complete heating cycle and delivers heat.
William S.
William S. Checked in
Responded to a no-heat call on an older gas furnace of undetermined age that would not stay lit. Inspected the burner compartment, gas valve assembly, and ignition components, performed the necessary service to restore proper ignition and flame retention, and verified the furnace runs through a complete heating cycle and delivers heat.
Akron, OH 44301
Replaced the corroded gas shut-off valve serving the laundry area, as the customer no longer required a gas line connection to the washer. Installed a new shut-off valve with approved thread sealant, then performed a leak test on the new connection to verify a secure, leak-free installation.
Replaced the corroded gas shut-off valve serving the laundry area, as the customer no longer required a gas line connection to the washer. Installed a new shut-off valve with approved thread sealant, then performed a leak test on the new connection to verify a secure, leak-free installation.
Mark W.
Mark W. Checked in
Replaced the corroded gas shut-off valve serving the laundry area, as the customer no longer required a gas line connection to the washer. Installed a new shut-off valve with approved thread sealant, then performed a leak test on the new connection to verify a secure, leak-free installation.
Akron, OH 44313

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image