Schedule Service

HVAC, Plumbing & Electrical Services in Barberton, OH

Whole-Home Generator

Maintaining a comfortable, functional, and safe home requires reliable HVAC, plumbing, and electrical services from a trusted team to get the job done right. Blind & Sons has proudly offered the comprehensive home service solutions that Barberton-area residents have relied on for over 85 years.

With emergency HVAC service availability and a 100% satisfaction guarantee, you can rest assured that our team will deliver the fast, effective solutions your home deserves.

Schedule HVAC, plumbing, and electrical services in Barberton, OH, by contacting our team today!

Proudly Serving the Barberton, OH Community

Barberton, OH, nestled in southern Summit County, is a city steeped in tradition and community pride. Known as the “Magic City” for its rapid growth in the early 20th century, Barberton still carries that spirit of resilience and progress. Its vibrant downtown area, historic neighborhoods, and the scenic shores of Lake Anna make Barberton a place where both heritage and modern living come together.

Home to local landmarks like the Barberton Public Library, the Magical Theatre Company, and annual events like the Cherry Blossom Festival and Mum Fest, Barberton exudes small-town charm with a strong sense of civic pride. Residents here value hard work, family, and preserving the character of their homes and neighborhoods.

Blind & Sons is proud to serve the Barberton community by offering expert HVAC, plumbing, and electrical services that align with the city’s unique needs. Whether it’s upgrading the electrical systems in a century-old home or installing high-efficiency HVAC units in newer builds, our team understands the infrastructure and local codes that matter most to Barberton homeowners.

We believe in delivering more than just home services—we provide peace of mind. With a commitment to punctuality, professionalism, and respect for your home, Blind & Sons is the trusted partner Barberton families rely on to keep their homes safe, comfortable, and efficient year-round.

 

Priority Heating & Cooling Services

Known for its hot, humid summers and ice-cold winters, Barberton residents know firsthand how essential it is to have a fully functioning heating and cooling system to maintain consistent comfort year-round. Our team specializes in HVAC installation and replacements, emergency repair services, and annual maintenance designed to keep your system running smoothly for the long term.

We have experience servicing all types of heating and cooling equipment, including:

  • Air conditioners: We provide top-notch AC services to maintain optimal cooling and energy efficiency.
  • Boilers: Our team expertly services boilers to ensure efficient, reliable heating for your home.
  • Ductless mini-splits: We specialize in servicing ductless mini-splits, offering flexible and efficient climate control solutions.
  • Furnaces: Our team is skilled at maintaining and repairing furnaces, which keep your space warm during the cold months.
  • Heat pumps: We ensure your heat pump operates at peak performance for both heating and cooling needs.

[cta_section]

Exceptional Electrical Services in Barberton

When it comes to electrical work, safety and precision matter. Blind & Sons is proud to provide Barberton homeowners with top-quality electrical services that ensure your home’s power system operates efficiently and safely. From new installations to complex repairs, our licensed electricians handle every project with the highest level of care and expertise.

Our electrical services cover the full range of needs for modern homes, including:

    • Electrical Installations & Replacements: Whether you’re remodeling a room or building an addition, we’ll wire your space to meet your electrical demands while ensuring code compliance.

    • Panel Upgrades: If your home still relies on outdated panels or frequently experiences tripped breakers, we’ll upgrade your electrical panel to meet today’s power needs.

    • Wiring Repairs & Maintenance: Faulty or aging wiring can be a safety hazard. We’ll inspect, repair, and maintain your wiring to prevent electrical fires and outages.

    • EV Charger Installation: Make charging your electric vehicle at home easy and efficient with our expert EV charger installation services.

    • Surge Protection: Protect your home’s sensitive electronics and appliances with whole-home surge protection systems that guard against sudden voltage spikes.

    • Electrical Panel Services: Whether you need an upgrade or repairs, our team ensures your electrical panel can safely support modern electrical demands.

Backup power is another priority for many homeowners in Barberton. With our generator installation and maintenance services, you’ll never have to worry about unexpected outages again. We work with industry-leading brands to ensure your generator is properly sized and installed for optimal performance.

Blind & Sons takes pride in clear communication, fair pricing, and solutions that stand the test of time. Whether you need a quick repair or a full system upgrade, our electrical team is here to help you power your home with confidence.

Top-Rated Plumbing Services

Close-up of male plumber fixing white sink pipe with adjustable wrench

Our team offers a full suite of plumbing services to keep your home’s water systems running smoothly and efficiently. We handle everything from installation and replacement to expert repair and maintenance, ensuring your plumbing infrastructure remains fully intact for the long term.

Our highly trained technicians specialize in thorough drain cleaning to prevent clogs and backups and provide comprehensive water heater services, including installation and repairs, to ensure you always have hot water. With gas line plumbing services conducted with the highest safety standards and reliable sump pump services to protect your basement from flooding, we go above and beyond to ensure the safety and integrity of your home plumbing system.

Sign Up for Our Maintenance Value Plan Today

Our Maintenance Value Plan provides several benefits to help keep your heating and cooling system running effectively, even on the coldest or hottest day. This plan offers:

  • An MVP-only phone number
  • Service & repair discounts 
  • Technician choice
  • Priority service for members
  • Plus, much more!

Schedule Services With Blind & Sons in Barberton Today

Since 1937, Blind & Sons has been the go-to source for reliable HVAC, electrical, and plumbing solutions throughout Barberton and the surrounding region. With emergency HVAC repair availability, no overtime fees, and 100% satisfaction guaranteed, we are confident in our ability to deliver prompt, professional solutions that withstand the test of time.

Contact the Blind & Sons team today to schedule HVAC, plumbing, or electrical services in Barberton, OH.

 

Recent Jobs and Reviews in Barberton, OH

Barberton, OH at a glance

Blind and Sons has completed 20 jobs in Barberton, OH in October 2026.

The most recent job was on October 22, 2026.

Blind and Sons has completed 676 jobs in Barberton, OH in the last 12 months.

Job Locations and Reviews

Performed a scheduled heating maintenance visit, inspecting the furnace control board and low-voltage wiring and verifying connections at the terminal block and connector. Measured gas manifold pressure with a digital manometer, recording approximately 11 inH₂O, and confirmed operation with no visible damage, corrosion, or leaks noted. Recommend securing and rerouting loose wiring and splices to prevent future connection issues.
Performed a scheduled heating maintenance visit, inspecting the furnace control board and low-voltage wiring and verifying connections at the terminal block and connector. Measured gas manifold pressure with a digital manometer, recording approximately 11 inH₂O, and confirmed operation with no visible damage, corrosion, or leaks noted. Recommend securing and rerouting loose wiring and splices to prevent future connection issues.
Colton D.
Colton D. Checked in
Performed a scheduled heating maintenance visit, inspecting the furnace control board and low-voltage wiring and verifying connections at the terminal block and connector. Measured gas manifold pressure with a digital manometer, recording approximately 11 inH₂O, and confirmed operation with no visible damage, corrosion, or leaks noted. Recommend securing and rerouting loose wiring and splices to prevent future connection issues.
Barberton, OH 44203
Performed MVP furnace maintenance, including inspection of the burner assembly, heat exchanger inlets, and gas valve connections, and documented rust, flaking corrosion, and scorching around the burner rims indicating age-related wear. Replaced the pleated return air filter, which showed uneven, bulging pleats, and checked the condensate drain piping and floor drain, noting dampness and staining that warrants monitoring for leaks or drainage restrictions. Recommend follow-up evaluation of the burner and heat exchanger components to ensure continued safe, efficient operation.
Performed MVP furnace maintenance, including inspection of the burner assembly, heat exchanger inlets, and gas valve connections, and documented rust, flaking corrosion, and scorching around the burner rims indicating age-related wear. Replaced the pleated return air filter, which showed uneven, bulging pleats, and checked the condensate drain piping and floor drain, noting dampness and staining that warrants monitoring for leaks or drainage restrictions. Recommend follow-up evaluation of the burner and heat exchanger components to ensure continued safe, efficient operation.
Kevin D.
Kevin D. Checked in
Performed MVP furnace maintenance, including inspection of the burner assembly, heat exchanger inlets, and gas valve connections, and documented rust, flaking corrosion, and scorching around the burner rims indicating age-related wear. Replaced the pleated return air filter, which showed uneven, bulging pleats, and checked the condensate drain piping and floor drain, noting dampness and staining that warrants monitoring for leaks or drainage restrictions. Recommend follow-up evaluation of the burner and heat exchanger components to ensure continued safe, efficient operation.
Barberton, OH 44203
Performed scheduled heating maintenance on the gas furnace, including inspection of the gas valve, pressure switch, inducer assembly, and associated wiring and connections. Verified gas manifold and system pressures using a dual-port digital manometer and measured electrical values with a clamp multimeter to confirm proper component operation. No signs of corrosion, damage, or abnormal wear were observed, and the furnace was left operating within normal parameters.
Performed scheduled heating maintenance on the gas furnace, including inspection of the gas valve, pressure switch, inducer assembly, and associated wiring and connections. Verified gas manifold and system pressures using a dual-port digital manometer and measured electrical values with a clamp multimeter to confirm proper component operation. No signs of corrosion, damage, or abnormal wear were observed, and the furnace was left operating within normal parameters.
Matthew F.
Matthew F. Checked in
Performed scheduled heating maintenance on the gas furnace, including inspection of the gas valve, pressure switch, inducer assembly, and associated wiring and connections. Verified gas manifold and system pressures using a dual-port digital manometer and measured electrical values with a clamp multimeter to confirm proper component operation. No signs of corrosion, damage, or abnormal wear were observed, and the furnace was left operating within normal parameters.
Barberton, OH 44203
Performed annual maintenance on a 6-year-old gas furnace, including combustion analysis in natural gas mode with readings of 9.9% O2, 6.2% CO2, 15 ppm CO, and 97.0% efficiency, all within acceptable operating ranges. Verified electrical operation with a clamp meter, measuring approximately 120 VAC supply voltage, and confirmed the unit is operating safely and normally with no abnormal conditions observed.
Performed annual maintenance on a 6-year-old gas furnace, including combustion analysis in natural gas mode with readings of 9.9% O2, 6.2% CO2, 15 ppm CO, and 97.0% efficiency, all within acceptable operating ranges. Verified electrical operation with a clamp meter, measuring approximately 120 VAC supply voltage, and confirmed the unit is operating safely and normally with no abnormal conditions observed.
Matthew F.
Matthew F. Checked in
Performed annual maintenance on a 6-year-old gas furnace, including combustion analysis in natural gas mode with readings of 9.9% O2, 6.2% CO2, 15 ppm CO, and 97.0% efficiency, all within acceptable operating ranges. Verified electrical operation with a clamp meter, measuring approximately 120 VAC supply voltage, and confirmed the unit is operating safely and normally with no abnormal conditions observed.
Barberton, OH 44203
Installed a dedicated circuit for the AC unit, running flexible metal conduit to a galvanized junction box mounted on the joist, with conductors spliced using listed twist-on wire connectors. Routed supply cabling through the basement framing, secured to the underside of the beam with cable staples. Verified connections and confirmed the circuit is properly terminated and ready for operation.
Installed a dedicated circuit for the AC unit, running flexible metal conduit to a galvanized junction box mounted on the joist, with conductors spliced using listed twist-on wire connectors. Routed supply cabling through the basement framing, secured to the underside of the beam with cable staples. Verified connections and confirmed the circuit is properly terminated and ready for operation.
Matthew H.
Matthew H. Checked in
Installed a dedicated circuit for the AC unit, running flexible metal conduit to a galvanized junction box mounted on the joist, with conductors spliced using listed twist-on wire connectors. Routed supply cabling through the basement framing, secured to the underside of the beam with cable staples. Verified connections and confirmed the circuit is properly terminated and ready for operation.
Barberton, OH 44203
Barberton, OH - Performed electrical maintenance on the standby generator, including a battery health assessment using a digital battery/CCA tester. Results confirmed the starting battery is in good condition, with 97% state of health, 100% state of charge, 13.34V, and 528A measured against the 540A rated CCA, indicating reliable starting capability.
Andrew V.
Andrew V. Checked in
Performed electrical maintenance on the standby generator, including a battery health assessment using a digital battery/CCA tester. Results confirmed the starting battery is in good condition, with 97% state of health, 100% state of charge, 13.34V, and 528A measured against the 540A rated CCA, indicating reliable starting capability.
Barberton, OH 44203
Performed seasonal heating maintenance on the furnace, including inspection of the integrated control board, wiring harness connections, and terminal fastenings, with all connections found secure and properly routed. Removed and inspected the flame sensor/ignition electrode rod, confirming no cracking or major damage to the ceramic insulator, and noted light surface oxidation on the rod consistent with normal wear. Observed minor rust spotting on the control panel and verified flue pipe and sealant details per installation guidelines.
Performed seasonal heating maintenance on the furnace, including inspection of the integrated control board, wiring harness connections, and terminal fastenings, with all connections found secure and properly routed. Removed and inspected the flame sensor/ignition electrode rod, confirming no cracking or major damage to the ceramic insulator, and noted light surface oxidation on the rod consistent with normal wear. Observed minor rust spotting on the control panel and verified flue pipe and sealant details per installation guidelines.
Stephanie E.
Stephanie E. Checked in
Performed seasonal heating maintenance on the furnace, including inspection of the integrated control board, wiring harness connections, and terminal fastenings, with all connections found secure and properly routed. Removed and inspected the flame sensor/ignition electrode rod, confirming no cracking or major damage to the ceramic insulator, and noted light surface oxidation on the rod consistent with normal wear. Observed minor rust spotting on the control panel and verified flue pipe and sealant details per installation guidelines.
Barberton, OH 44203
Performed a replacement estimate on a 40+ year-old furnace with a no-heat condition; unit is obsolete and replacement parts are unavailable. Inspected the basement installation, including the furnace, flue/vent piping, ductwork, and adjacent water heater, and documented existing conditions with photos. Recommended full furnace replacement.
Performed a replacement estimate on a 40+ year-old furnace with a no-heat condition; unit is obsolete and replacement parts are unavailable. Inspected the basement installation, including the furnace, flue/vent piping, ductwork, and adjacent water heater, and documented existing conditions with photos. Recommended full furnace replacement.
Dave T.
Dave T. Checked in
Performed a replacement estimate on a 40+ year-old furnace with a no-heat condition; unit is obsolete and replacement parts are unavailable. Inspected the basement installation, including the furnace, flue/vent piping, ductwork, and adjacent water heater, and documented existing conditions with photos. Recommended full furnace replacement.
Barberton, OH 44203
Responded to a no-heat call on a 41+ year old basement furnace and inspected the blower/motor compartment, finding the motor, wiring, and cabinet heavily coated with dust, dirt, and cobwebs. Evaluated the blower motor, wiring, and cabinet condition to diagnose the loss of heat, noting the unit's advanced age and deteriorated condition.
Responded to a no-heat call on a 41+ year old basement furnace and inspected the blower/motor compartment, finding the motor, wiring, and cabinet heavily coated with dust, dirt, and cobwebs. Evaluated the blower motor, wiring, and cabinet condition to diagnose the loss of heat, noting the unit's advanced age and deteriorated condition.
Jibreel H.
Jibreel H. Checked in
Responded to a no-heat call on a 41+ year old basement furnace and inspected the blower/motor compartment, finding the motor, wiring, and cabinet heavily coated with dust, dirt, and cobwebs. Evaluated the blower motor, wiring, and cabinet condition to diagnose the loss of heat, noting the unit's advanced age and deteriorated condition.
Barberton, OH 44203
Performed annual heating maintenance on a 5-year-old furnace, including inspection and cleaning of the hot surface ignitor assembly and flame sensing components. Inspected the blower wheel and housing, removed accumulated dust and debris from the blades, and verified secure motor shaft and set screw. Checked the PVC flue/vent connection and rubber coupling, noting minor discoloration at the pipe base, and confirmed secure fasteners and proper operation of the unit.
Performed annual heating maintenance on a 5-year-old furnace, including inspection and cleaning of the hot surface ignitor assembly and flame sensing components. Inspected the blower wheel and housing, removed accumulated dust and debris from the blades, and verified secure motor shaft and set screw. Checked the PVC flue/vent connection and rubber coupling, noting minor discoloration at the pipe base, and confirmed secure fasteners and proper operation of the unit.
Taylor F.
Taylor F. Checked in
Performed annual heating maintenance on a 5-year-old furnace, including inspection and cleaning of the hot surface ignitor assembly and flame sensing components. Inspected the blower wheel and housing, removed accumulated dust and debris from the blades, and verified secure motor shaft and set screw. Checked the PVC flue/vent connection and rubber coupling, noting minor discoloration at the pipe base, and confirmed secure fasteners and proper operation of the unit.
Barberton, OH 44203
Performed seasonal heating maintenance on a 5-year-old gas furnace, inspecting the blower assembly, control board, transformer, and low-voltage wiring, and found all components intact with no visible damage, corrosion, or frost. Verified the condensate drain line connection and checked the cabinet interior, noting loose low-voltage wiring in the lower cabinet and dust accumulation. Unit is in good working condition.
Performed seasonal heating maintenance on a 5-year-old gas furnace, inspecting the blower assembly, control board, transformer, and low-voltage wiring, and found all components intact with no visible damage, corrosion, or frost. Verified the condensate drain line connection and checked the cabinet interior, noting loose low-voltage wiring in the lower cabinet and dust accumulation. Unit is in good working condition.
Derrick M.
Derrick M. Checked in
Performed seasonal heating maintenance on a 5-year-old gas furnace, inspecting the blower assembly, control board, transformer, and low-voltage wiring, and found all components intact with no visible damage, corrosion, or frost. Verified the condensate drain line connection and checked the cabinet interior, noting loose low-voltage wiring in the lower cabinet and dust accumulation. Unit is in good working condition.
Barberton, OH 44203
Performed scheduled maintenance on a Generac standby generator, removing the top and side access panels to inspect the interior components, including the battery, terminal connections, and enclosure. Verified the unit was clean, intact, and free of visible damage, with the flexible conduit connection to the structure and the controller indicator in normal condition.
Performed scheduled maintenance on a Generac standby generator, removing the top and side access panels to inspect the interior components, including the battery, terminal connections, and enclosure. Verified the unit was clean, intact, and free of visible damage, with the flexible conduit connection to the structure and the controller indicator in normal condition.
Eric L.
Eric L. Checked in
Performed scheduled maintenance on a Generac standby generator, removing the top and side access panels to inspect the interior components, including the battery, terminal connections, and enclosure. Verified the unit was clean, intact, and free of visible damage, with the flexible conduit connection to the structure and the controller indicator in normal condition.
Barberton, OH 44203
Responded to a no-heat call on a Lennox gas furnace over 30 years old, accessed the control compartment, and performed electrical diagnostics with a clamp meter on the contactor/relay, wiring, and associated components to identify the cause of the heat failure. Unit is well past its expected service life, with heavy dust and grime buildup on the cabinet and ductwork and corroded, aged piping and insulation noted; replacement should be considered.
Responded to a no-heat call on a Lennox gas furnace over 30 years old, accessed the control compartment, and performed electrical diagnostics with a clamp meter on the contactor/relay, wiring, and associated components to identify the cause of the heat failure. Unit is well past its expected service life, with heavy dust and grime buildup on the cabinet and ductwork and corroded, aged piping and insulation noted; replacement should be considered.
Frank W.
Frank W. Checked in
Responded to a no-heat call on a Lennox gas furnace over 30 years old, accessed the control compartment, and performed electrical diagnostics with a clamp meter on the contactor/relay, wiring, and associated components to identify the cause of the heat failure. Unit is well past its expected service life, with heavy dust and grime buildup on the cabinet and ductwork and corroded, aged piping and insulation noted; replacement should be considered.
Barberton, OH 44203
Inspected the gas fireplace supply and located the branch line with its shutoff valve in the joist space below the fireplace. Verified the gas supply path and valve position to the log set and burner, confirmed the control module and burner assembly were intact, and restored gas flow to the fireplace.
Inspected the gas fireplace supply and located the branch line with its shutoff valve in the joist space below the fireplace. Verified the gas supply path and valve position to the log set and burner, confirmed the control module and burner assembly were intact, and restored gas flow to the fireplace.
Travis B.
Travis B. Checked in
Inspected the gas fireplace supply and located the branch line with its shutoff valve in the joist space below the fireplace. Verified the gas supply path and valve position to the log set and burner, confirmed the control module and burner assembly were intact, and restored gas flow to the fireplace.
Barberton, OH 44203
Performed seasonal heating maintenance on a Lennox gas furnace, including inspection of the blower compartment, control board, and low-voltage wiring, and noted heavy dust and lint accumulation at the filter slot and cabinet floor. Inspected the PVC combustion air and venting assembly and observed orange-brown staining on the floor beneath the unit, indicating prior moisture or rust residue that should be monitored for leaks or condensate drainage issues. Unit was left operational, with recommendations for filter replacement and cabinet cleaning.
Performed seasonal heating maintenance on a Lennox gas furnace, including inspection of the blower compartment, control board, and low-voltage wiring, and noted heavy dust and lint accumulation at the filter slot and cabinet floor. Inspected the PVC combustion air and venting assembly and observed orange-brown staining on the floor beneath the unit, indicating prior moisture or rust residue that should be monitored for leaks or condensate drainage issues. Unit was left operational, with recommendations for filter replacement and cabinet cleaning.
Derrick M.
Derrick M. Checked in
Performed seasonal heating maintenance on a Lennox gas furnace, including inspection of the blower compartment, control board, and low-voltage wiring, and noted heavy dust and lint accumulation at the filter slot and cabinet floor. Inspected the PVC combustion air and venting assembly and observed orange-brown staining on the floor beneath the unit, indicating prior moisture or rust residue that should be monitored for leaks or condensate drainage issues. Unit was left operational, with recommendations for filter replacement and cabinet cleaning.
Barberton, OH 44203
Barberton, OH - Responded to a report of a 4-5 year old sump pump short-cycling, turning on and off every couple of minutes. Marked underground utilities in the work area and staged discharge piping components on site. Inspected the pump system and discharge line to diagnose the cycling condition.
James P.
James P. Checked in
Responded to a report of a 4-5 year old sump pump short-cycling, turning on and off every couple of minutes. Marked underground utilities in the work area and staged discharge piping components on site. Inspected the pump system and discharge line to diagnose the cycling condition.
Barberton, OH 44203
Performed a 100A electrical service upgrade, including installation of an exterior service disconnect and updated grounding electrode system to meet 2023 National Electrical Code requirements. Excavated and installed new ground rod(s) with proper bonding and connections, and verified the completed installation for code-compliant operation.
Performed a 100A electrical service upgrade, including installation of an exterior service disconnect and updated grounding electrode system to meet 2023 National Electrical Code requirements. Excavated and installed new ground rod(s) with proper bonding and connections, and verified the completed installation for code-compliant operation.
Bradley L.
Bradley L. Checked in
Performed a 100A electrical service upgrade, including installation of an exterior service disconnect and updated grounding electrode system to meet 2023 National Electrical Code requirements. Excavated and installed new ground rod(s) with proper bonding and connections, and verified the completed installation for code-compliant operation.
Barberton, OH 44203
Replaced the failed toilet supply shut-off valve that had broken off, restoring a functional isolation point at the water supply line. Inspected the tank and installed new toilet repair components, including a flush valve assembly, flapper, and handle, to address the worn internal parts and discolored, stained tank conditions. Verified the supply connection was leak-free and confirmed proper fill and flush operation.
Replaced the failed toilet supply shut-off valve that had broken off, restoring a functional isolation point at the water supply line. Inspected the tank and installed new toilet repair components, including a flush valve assembly, flapper, and handle, to address the worn internal parts and discolored, stained tank conditions. Verified the supply connection was leak-free and confirmed proper fill and flush operation.
Craig S.
Craig S. Checked in
Replaced the failed toilet supply shut-off valve that had broken off, restoring a functional isolation point at the water supply line. Inspected the tank and installed new toilet repair components, including a flush valve assembly, flapper, and handle, to address the worn internal parts and discolored, stained tank conditions. Verified the supply connection was leak-free and confirmed proper fill and flush operation.
Barberton, OH 44203
Removed the existing toilet and installed a customer-supplied American Standard Edgemere toilet. The closet flange showed heavy rust and scale buildup, and the finished installation was left clean and operational with no additional parts required.
Removed the existing toilet and installed a customer-supplied American Standard Edgemere toilet. The closet flange showed heavy rust and scale buildup, and the finished installation was left clean and operational with no additional parts required.
James P.
James P. Checked in
Removed the existing toilet and installed a customer-supplied American Standard Edgemere toilet. The closet flange showed heavy rust and scale buildup, and the finished installation was left clean and operational with no additional parts required.
Barberton, OH 44203
Barberton, OH - Performed a complete furnace tune-up, including inspection and testing of components and verification of safe, proper operation. Inspected the whole-house humidifier and found the evaporator pad showing mineral buildup and discoloration, with the unit's drain line and housing in place. Completed the maintenance membership renewal.
John W.
John W. Checked in
Performed a complete furnace tune-up, including inspection and testing of components and verification of safe, proper operation. Inspected the whole-house humidifier and found the evaporator pad showing mineral buildup and discoloration, with the unit's drain line and housing in place. Completed the maintenance membership renewal.
Barberton, OH 44203

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image