Schedule Service

Heating, Cooling, Plumbing & Electrical Repair in Barberton, OH

Barberton has a lot of homes that have simply been lived in hard for generations. Around Wooster Road, 31st Street, and the neighborhoods surrounding Lake Anna, it is common to find older mechanical systems that have been added onto, rerouted, or repaired piece by piece over the years. Blind & Sons spends a lot of time helping Barberton homeowners sort through furnace problems, overloaded electrical systems, basement water concerns, and cooling issues tied to aging homes that were built long before modern comfort expectations.

A lot of homes throughout Barberton still rely on older duct layouts, aging plumbing lines, and electrical systems that were never designed for today’s demand. Whether you are dealing with uneven temperatures, recurring plumbing issues, or electrical upgrades that need to be done safely, call 330-362-9232 or contact Blind & Sons online to schedule service in Barberton.

Need Services?

What Starts Breaking Down First in Older Barberton Homes

A large portion of Barberton’s housing stock dates back to the city’s manufacturing years, and you can still see it in the way many homes are laid out today. We regularly walk into homes where the original ductwork is still in place, the plumbing has been partially updated over the years, and electrical systems are carrying far more load than they were originally built for. Some of the most common calls we handle in Barberton involve:

  • Furnaces struggling to heat evenly
  • Aging water heaters and drain systems
  • Electrical panels running out of capacity
  • Basement moisture and sump pump failures
  • Weak airflow in upstairs rooms
  • AC systems running constantly during humid weather

Most of the time, these problems build gradually. A room gets added, the basement gets finished, another appliance gets installed, and eventually the original system starts falling behind.

Heating & Furnace Repair in Barberton, OH

Cold weather tends to expose every weak spot in an older heating system. We regularly service Barberton homes where certain rooms stay chilly no matter how long the furnace runs, older boilers struggle to keep up, or airflow problems make the house feel uneven from one floor to the next. Heating services in Barberton we provide include:

  • Emergency heating repair
  • Heating maintenance
  • Furnace repair and replacement
  • Boiler repair and installation
  • Heat pump services
  • Ductless HVAC systems
  • Hybrid heating systems

Many heating problems we see throughout Barberton are connected to ductwork that was never updated after remodeling projects or additions were completed. Even newer furnaces can struggle if the airflow system attached to them is outdated.

Plumbing & Water Heater Services in Barberton, OH

A lot of plumbing problems in Barberton start quietly. A drain slows down little by little, water pressure drops over time, or the sump pump only acts up during heavy rain. We regularly replace aging water heaters, track down drain issues, and help homeowners avoid basement water problems before they turn into larger repairs. Blind & Sons handles:

  • Plumbing repair
  • Plumbing maintenance
  • Drain cleaning
  • Water heater repair and installation
  • Plumbing fixtures
  • Sewer services
  • Sewer camera inspections
  • Septic services
  • Gas line services
  • Sump pumps
  • Water treatment systems

Older homes near downtown Barberton and surrounding residential areas often still have aging plumbing infrastructure that requires more than temporary fixes. Our technicians take time to identify what is actually causing the issue instead of only treating the symptom.

Electrical Services in Barberton, OH

A lot of Barberton electrical systems were built for a completely different era. We regularly work in homes where older breaker panels are now trying to support larger HVAC systems, garage equipment, home offices, generators, and modern appliances all at once. Electrical services available throughout Barberton include:

  • Electrical repair
  • Electrical installation
  • Electrical inspections
  • Whole-home generators
  • Indoor and outdoor lighting
  • Electrical panel upgrades
  • Surge protection
  • EV charger installation
  • Electrical wiring and rewiring

We also see many older homes where enclosed back porches, garages, and additions were tied into the electrical system years later without properly upgrading the panel. That is often where flickering lights, overloaded circuits, and recurring electrical issues begin.

Indoor Air Quality Services in Barberton, OH

Older Barberton homes tend to trap a lot of dust, dry air, and uneven airflow throughout the year. We regularly work in homes where aging return vents and older duct systems struggle to circulate air evenly between floors. Blind & Sons installs and services:

  • Air handlers
  • Air cleaners
  • Air scrubbers
  • CleanAir technology
  • Duct cleaning
  • Dehumidifiers
  • Humidifiers
  • UV air purifiers

Many homeowners notice the biggest difference during winter when dry indoor air starts affecting comfort, sleep, hardwood flooring, and overall air quality inside the house.

Air Conditioning Services in Barberton, OH

Summer comfort problems in Barberton usually come back to airflow and humidity. Many older homes were never designed around central air, which is why upstairs bedrooms, enclosed porches, and additions often stay warmer than the rest of the house once the humidity kicks in. Cooling and AC services we provide throughout Barberton include:

  • Air conditioning repair
  • Emergency AC repair
  • AC maintenance
  • AC replacement
  • Heat pump repair and replacement
  • Heat pump maintenance
  • Ductless HVAC systems
  • Smart thermostats

We regularly work in homes where upstairs bedrooms stay warmer than the rest of the house or where additions never seem to cool properly. A lot of those issues trace back to duct sizing and airflow design instead of the AC unit alone.

Why Barberton Homeowners Continue Calling Blind & Sons

Blind & Sons already services homes across Barberton every week, so our technicians are familiar with the older layouts, aging infrastructure, and recurring repair issues homeowners here commonly deal with.

Homeowners throughout Barberton continue choosing Blind & Sons because we provide:

  • Fast scheduling and responsive service
  • Experienced HVAC, plumbing, and electrical technicians
  • Emergency repair availability
  • Financing options on qualifying systems
  • Honest recommendations without pressure
  • Respectful, clean work inside the home

We believe homeowners should understand what is happening inside their home before making a repair decision. Our technicians take time to explain the issue, walk through the available options, and help you decide what makes the most sense for your house and budget.

What Our Barberton Customers Are Saying

“Austin is the man!” I had to wait a few weeks to get him back but the quality of work he provides is well worth the wait. Five lights installed and we definitely want him back to finish more projects.

Marilyn A. (Homeowner, Barberton Area) – Rated 5/5 Stars

“Couldn’t be happier with Blind & Sons!” I love my new furnace and central air installed early last year. The crew did a wonderful job with installation and clean up.

Melanie M. (Homeowner, Summit County) – Rated 5/5 Stars

“Jesus Martinez was our technician, and he was fantastic!” He worked quickly, explained everything in detail, and showed me small maintenance tasks I could do to help keep the furnace in good condition. Very satisfied with the help I received.

Christian A. (Homeowner, Barberton) – Rated 5/5 Stars

Get a Barberton Technician Who Knows Older Homes

When something starts acting up in your home, whether it is the furnace struggling to keep up, a sump pump that sounds different than usual, or an electrical panel showing its age, it helps to work with technicians who have already seen these problems in Barberton homes many times before.

Blind & Sons already works throughout Barberton every week helping homeowners keep older systems running safely and reliably. Call 330-362-9232 or contact us online today to schedule heating, cooling, plumbing, or electrical service in Barberton, OH.

Need Services?


Recent Jobs and Reviews in Barberton, OH

Barberton, OH at a glance

Blind and Sons has completed 20 jobs in Barberton, OH in October 2026.

The most recent job was on October 20, 2026.

Blind and Sons has completed 707 jobs in Barberton, OH in the last 12 months.

Job Locations and Reviews

Performed seasonal heating maintenance on a 5-year-old gas furnace, inspecting the blower assembly, control board, transformer, and low-voltage wiring, and found all components intact with no visible damage, corrosion, or frost. Verified the condensate drain line connection and checked the cabinet interior, noting loose low-voltage wiring in the lower cabinet and dust accumulation. Unit is in good working condition.
Performed seasonal heating maintenance on a 5-year-old gas furnace, inspecting the blower assembly, control board, transformer, and low-voltage wiring, and found all components intact with no visible damage, corrosion, or frost. Verified the condensate drain line connection and checked the cabinet interior, noting loose low-voltage wiring in the lower cabinet and dust accumulation. Unit is in good working condition.
Derrick M.
Derrick M. Checked in
Performed seasonal heating maintenance on a 5-year-old gas furnace, inspecting the blower assembly, control board, transformer, and low-voltage wiring, and found all components intact with no visible damage, corrosion, or frost. Verified the condensate drain line connection and checked the cabinet interior, noting loose low-voltage wiring in the lower cabinet and dust accumulation. Unit is in good working condition.
Barberton, OH 44203
Performed scheduled maintenance on a Generac standby generator, removing the top and side access panels to inspect the interior components, including the battery, terminal connections, and enclosure. Verified the unit was clean, intact, and free of visible damage, with the flexible conduit connection to the structure and the controller indicator in normal condition.
Performed scheduled maintenance on a Generac standby generator, removing the top and side access panels to inspect the interior components, including the battery, terminal connections, and enclosure. Verified the unit was clean, intact, and free of visible damage, with the flexible conduit connection to the structure and the controller indicator in normal condition.
Eric L.
Eric L. Checked in
Performed scheduled maintenance on a Generac standby generator, removing the top and side access panels to inspect the interior components, including the battery, terminal connections, and enclosure. Verified the unit was clean, intact, and free of visible damage, with the flexible conduit connection to the structure and the controller indicator in normal condition.
Barberton, OH 44203
Responded to a no-heat call on a Lennox gas furnace over 30 years old, accessed the control compartment, and performed electrical diagnostics with a clamp meter on the contactor/relay, wiring, and associated components to identify the cause of the heat failure. Unit is well past its expected service life, with heavy dust and grime buildup on the cabinet and ductwork and corroded, aged piping and insulation noted; replacement should be considered.
Responded to a no-heat call on a Lennox gas furnace over 30 years old, accessed the control compartment, and performed electrical diagnostics with a clamp meter on the contactor/relay, wiring, and associated components to identify the cause of the heat failure. Unit is well past its expected service life, with heavy dust and grime buildup on the cabinet and ductwork and corroded, aged piping and insulation noted; replacement should be considered.
Frank W.
Frank W. Checked in
Responded to a no-heat call on a Lennox gas furnace over 30 years old, accessed the control compartment, and performed electrical diagnostics with a clamp meter on the contactor/relay, wiring, and associated components to identify the cause of the heat failure. Unit is well past its expected service life, with heavy dust and grime buildup on the cabinet and ductwork and corroded, aged piping and insulation noted; replacement should be considered.
Barberton, OH 44203
Inspected the gas fireplace supply and located the branch line with its shutoff valve in the joist space below the fireplace. Verified the gas supply path and valve position to the log set and burner, confirmed the control module and burner assembly were intact, and restored gas flow to the fireplace.
Inspected the gas fireplace supply and located the branch line with its shutoff valve in the joist space below the fireplace. Verified the gas supply path and valve position to the log set and burner, confirmed the control module and burner assembly were intact, and restored gas flow to the fireplace.
Travis B.
Travis B. Checked in
Inspected the gas fireplace supply and located the branch line with its shutoff valve in the joist space below the fireplace. Verified the gas supply path and valve position to the log set and burner, confirmed the control module and burner assembly were intact, and restored gas flow to the fireplace.
Barberton, OH 44203
Performed seasonal heating maintenance on a Lennox gas furnace, including inspection of the blower compartment, control board, and low-voltage wiring, and noted heavy dust and lint accumulation at the filter slot and cabinet floor. Inspected the PVC combustion air and venting assembly and observed orange-brown staining on the floor beneath the unit, indicating prior moisture or rust residue that should be monitored for leaks or condensate drainage issues. Unit was left operational, with recommendations for filter replacement and cabinet cleaning.
Performed seasonal heating maintenance on a Lennox gas furnace, including inspection of the blower compartment, control board, and low-voltage wiring, and noted heavy dust and lint accumulation at the filter slot and cabinet floor. Inspected the PVC combustion air and venting assembly and observed orange-brown staining on the floor beneath the unit, indicating prior moisture or rust residue that should be monitored for leaks or condensate drainage issues. Unit was left operational, with recommendations for filter replacement and cabinet cleaning.
Derrick M.
Derrick M. Checked in
Performed seasonal heating maintenance on a Lennox gas furnace, including inspection of the blower compartment, control board, and low-voltage wiring, and noted heavy dust and lint accumulation at the filter slot and cabinet floor. Inspected the PVC combustion air and venting assembly and observed orange-brown staining on the floor beneath the unit, indicating prior moisture or rust residue that should be monitored for leaks or condensate drainage issues. Unit was left operational, with recommendations for filter replacement and cabinet cleaning.
Barberton, OH 44203
Barberton, OH - Responded to a report of a 4-5 year old sump pump short-cycling, turning on and off every couple of minutes. Marked underground utilities in the work area and staged discharge piping components on site. Inspected the pump system and discharge line to diagnose the cycling condition.
James P.
James P. Checked in
Responded to a report of a 4-5 year old sump pump short-cycling, turning on and off every couple of minutes. Marked underground utilities in the work area and staged discharge piping components on site. Inspected the pump system and discharge line to diagnose the cycling condition.
Barberton, OH 44203
Performed a 100A electrical service upgrade, including installation of an exterior service disconnect and updated grounding electrode system to meet 2023 National Electrical Code requirements. Excavated and installed new ground rod(s) with proper bonding and connections, and verified the completed installation for code-compliant operation.
Performed a 100A electrical service upgrade, including installation of an exterior service disconnect and updated grounding electrode system to meet 2023 National Electrical Code requirements. Excavated and installed new ground rod(s) with proper bonding and connections, and verified the completed installation for code-compliant operation.
Bradley L.
Bradley L. Checked in
Performed a 100A electrical service upgrade, including installation of an exterior service disconnect and updated grounding electrode system to meet 2023 National Electrical Code requirements. Excavated and installed new ground rod(s) with proper bonding and connections, and verified the completed installation for code-compliant operation.
Barberton, OH 44203
Replaced the failed toilet supply shut-off valve that had broken off, restoring a functional isolation point at the water supply line. Inspected the tank and installed new toilet repair components, including a flush valve assembly, flapper, and handle, to address the worn internal parts and discolored, stained tank conditions. Verified the supply connection was leak-free and confirmed proper fill and flush operation.
Replaced the failed toilet supply shut-off valve that had broken off, restoring a functional isolation point at the water supply line. Inspected the tank and installed new toilet repair components, including a flush valve assembly, flapper, and handle, to address the worn internal parts and discolored, stained tank conditions. Verified the supply connection was leak-free and confirmed proper fill and flush operation.
Craig S.
Craig S. Checked in
Replaced the failed toilet supply shut-off valve that had broken off, restoring a functional isolation point at the water supply line. Inspected the tank and installed new toilet repair components, including a flush valve assembly, flapper, and handle, to address the worn internal parts and discolored, stained tank conditions. Verified the supply connection was leak-free and confirmed proper fill and flush operation.
Barberton, OH 44203
Removed the existing toilet and installed a customer-supplied American Standard Edgemere toilet. The closet flange showed heavy rust and scale buildup, and the finished installation was left clean and operational with no additional parts required.
Removed the existing toilet and installed a customer-supplied American Standard Edgemere toilet. The closet flange showed heavy rust and scale buildup, and the finished installation was left clean and operational with no additional parts required.
James P.
James P. Checked in
Removed the existing toilet and installed a customer-supplied American Standard Edgemere toilet. The closet flange showed heavy rust and scale buildup, and the finished installation was left clean and operational with no additional parts required.
Barberton, OH 44203
Barberton, OH - Performed a complete furnace tune-up, including inspection and testing of components and verification of safe, proper operation. Inspected the whole-house humidifier and found the evaporator pad showing mineral buildup and discoloration, with the unit's drain line and housing in place. Completed the maintenance membership renewal.
John W.
John W. Checked in
Performed a complete furnace tune-up, including inspection and testing of components and verification of safe, proper operation. Inspected the whole-house humidifier and found the evaporator pad showing mineral buildup and discoloration, with the unit's drain line and housing in place. Completed the maintenance membership renewal.
Barberton, OH 44203
Barberton, OH - Returned to correct deficiencies identified during the failed inspection on the hydronic boiler installation, installing the required parts and verifying the system for compliance. Inspected the boiler, flue connection, supply/return piping, isolation valve, aquastat control, and electrical supply, confirming secure fittings, proper support, and no signs of leaks or major corrosion, with system pressure reading within normal operating range.
Karl M.
Karl M. Checked in
Returned to correct deficiencies identified during the failed inspection on the hydronic boiler installation, installing the required parts and verifying the system for compliance. Inspected the boiler, flue connection, supply/return piping, isolation valve, aquastat control, and electrical supply, confirming secure fittings, proper support, and no signs of leaks or major corrosion, with system pressure reading within normal operating range.
Barberton, OH 44203
Installed a new Lennox condensing unit on a level pad at the side of the structure and completed the line set connection through a sealed wall penetration, with insulated refrigerant lines routed along the foundation. Mounted and wired a new electrical disconnect with weatherproof flexible conduit to the condenser, completing the A/C-only system installation.
Installed a new Lennox condensing unit on a level pad at the side of the structure and completed the line set connection through a sealed wall penetration, with insulated refrigerant lines routed along the foundation. Mounted and wired a new electrical disconnect with weatherproof flexible conduit to the condenser, completing the A/C-only system installation.
Charles A.
Charles A. Checked in
Installed a new Lennox condensing unit on a level pad at the side of the structure and completed the line set connection through a sealed wall penetration, with insulated refrigerant lines routed along the foundation. Mounted and wired a new electrical disconnect with weatherproof flexible conduit to the condenser, completing the A/C-only system installation.
Barberton, OH 44203
Performed scheduled heating maintenance, accessing the blower assembly to inspect the squirrel-cage blower wheel, motor shaft, and hub. Verified set screw and hex nut were secure using a hex key, and found only light dust accumulation on the blades with no signs of rust, ice, or structural damage. Components were found to be intact and operating within normal condition.
Performed scheduled heating maintenance, accessing the blower assembly to inspect the squirrel-cage blower wheel, motor shaft, and hub. Verified set screw and hex nut were secure using a hex key, and found only light dust accumulation on the blades with no signs of rust, ice, or structural damage. Components were found to be intact and operating within normal condition.
Taylor F.
Taylor F. Checked in
Performed scheduled heating maintenance, accessing the blower assembly to inspect the squirrel-cage blower wheel, motor shaft, and hub. Verified set screw and hex nut were secure using a hex key, and found only light dust accumulation on the blades with no signs of rust, ice, or structural damage. Components were found to be intact and operating within normal condition.
Barberton, OH 44203
Barberton, OH - Inspected a tanked water heater leaking from the top and found corrosion on the inlet and outlet fittings, including the shutoff valve, which is the likely leak source. Documented the venting, piping, and insulation condition, and reviewed warranty coverage and repair options with the homeowner.
Denny J.
Denny J. Checked in
Inspected a tanked water heater leaking from the top and found corrosion on the inlet and outlet fittings, including the shutoff valve, which is the likely leak source. Documented the venting, piping, and insulation condition, and reviewed warranty coverage and repair options with the homeowner.
Barberton, OH 44203
Responded to a no-hot-water call on a 40–50 gallon gas water heater approximately 6–7 years old, finding the pilot flame out. Inspection of the burner compartment revealed heavy corrosion, scorching, and mineral/oxidation deposits on the burner and surrounding components, indicating a failed, unserviceable tank. Wall sections were cut open along the baseboard to investigate for leak-related moisture damage and expose the affected area for the repair.
Responded to a no-hot-water call on a 40–50 gallon gas water heater approximately 6–7 years old, finding the pilot flame out. Inspection of the burner compartment revealed heavy corrosion, scorching, and mineral/oxidation deposits on the burner and surrounding components, indicating a failed, unserviceable tank. Wall sections were cut open along the baseboard to investigate for leak-related moisture damage and expose the affected area for the repair.
Mark W.
Mark W. Checked in
Responded to a no-hot-water call on a 40–50 gallon gas water heater approximately 6–7 years old, finding the pilot flame out. Inspection of the burner compartment revealed heavy corrosion, scorching, and mineral/oxidation deposits on the burner and surrounding components, indicating a failed, unserviceable tank. Wall sections were cut open along the baseboard to investigate for leak-related moisture damage and expose the affected area for the repair.
Barberton, OH 44203
Performed a seasonal heating maintenance inspection and identified a heavily loaded pleated air filter with significant dust, lint, and debris accumulation restricting airflow, along with dust and grime buildup on the blower assembly's squirrel-cage wheel and housing. Cleaned the blower wheel and surrounding housing, removed accumulated debris from the cabinet interior, and replaced the clogged filter to restore proper airflow and system efficiency. Verified system operation following service.
Performed a seasonal heating maintenance inspection and identified a heavily loaded pleated air filter with significant dust, lint, and debris accumulation restricting airflow, along with dust and grime buildup on the blower assembly's squirrel-cage wheel and housing. Cleaned the blower wheel and surrounding housing, removed accumulated debris from the cabinet interior, and replaced the clogged filter to restore proper airflow and system efficiency. Verified system operation following service.
Daniel
Daniel Checked in
Performed a seasonal heating maintenance inspection and identified a heavily loaded pleated air filter with significant dust, lint, and debris accumulation restricting airflow, along with dust and grime buildup on the blower assembly's squirrel-cage wheel and housing. Cleaned the blower wheel and surrounding housing, removed accumulated debris from the cabinet interior, and replaced the clogged filter to restore proper airflow and system efficiency. Verified system operation following service.
Barberton, OH 44203
Performed scheduled heating maintenance on a 2-year-old system, inspecting the blower assembly and finding light dust accumulation on the squirrel-cage fan blades. Verified blower motor operation with a True RMS clamp meter, measuring a running current draw of 15.9 amps, to confirm electrical performance during the heating cycle.
Performed scheduled heating maintenance on a 2-year-old system, inspecting the blower assembly and finding light dust accumulation on the squirrel-cage fan blades. Verified blower motor operation with a True RMS clamp meter, measuring a running current draw of 15.9 amps, to confirm electrical performance during the heating cycle.
Daniel
Daniel Checked in
Performed scheduled heating maintenance on a 2-year-old system, inspecting the blower assembly and finding light dust accumulation on the squirrel-cage fan blades. Verified blower motor operation with a True RMS clamp meter, measuring a running current draw of 15.9 amps, to confirm electrical performance during the heating cycle.
Barberton, OH 44203
Responded to a reported leak at a Bradford White tank-style gas water heater and inspected the unit, flue connection, supply piping, and expansion tank in the basement mechanical area. The inspection showed no visible corrosion, rust, or tank damage, and the surrounding components, including the expansion tank and its copper fittings, were clean and intact. Verified the system was in serviceable condition and documented the installation with photos.
Responded to a reported leak at a Bradford White tank-style gas water heater and inspected the unit, flue connection, supply piping, and expansion tank in the basement mechanical area. The inspection showed no visible corrosion, rust, or tank damage, and the surrounding components, including the expansion tank and its copper fittings, were clean and intact. Verified the system was in serviceable condition and documented the installation with photos.
James P.
James P. Checked in
Responded to a reported leak at a Bradford White tank-style gas water heater and inspected the unit, flue connection, supply piping, and expansion tank in the basement mechanical area. The inspection showed no visible corrosion, rust, or tank damage, and the surrounding components, including the expansion tank and its copper fittings, were clean and intact. Verified the system was in serviceable condition and documented the installation with photos.
Barberton, OH 44203
Responded to service call for non-functional toilet with broken flush handle and cracked porcelain tank. Upon inspection, confirmed fixture damage requiring full toilet replacement. Documented existing conditions and discussed replacement options with customer to restore proper bathroom functionality.
Responded to service call for non-functional toilet with broken flush handle and cracked porcelain tank. Upon inspection, confirmed fixture damage requiring full toilet replacement. Documented existing conditions and discussed replacement options with customer to restore proper bathroom functionality.
Nick L.
Nick L. Checked in
Responded to service call for non-functional toilet with broken flush handle and cracked porcelain tank. Upon inspection, confirmed fixture damage requiring full toilet replacement. Documented existing conditions and discussed replacement options with customer to restore proper bathroom functionality.
Barberton, OH 44203
Responded to no heat call on 20-year-old Carrier Weathermaker Infinity furnace with blower running continuously. Upon arrival, found system switched off by homeowner. Diagnosed failed blower relay causing continuous blower operation and loss of heating function. Replaced defective relay, tested all safety controls, and verified proper ignition sequence and burner operation. System restored to normal heating operation with blower cycling correctly on thermostat demand.
Responded to no heat call on 20-year-old Carrier Weathermaker Infinity furnace with blower running continuously. Upon arrival, found system switched off by homeowner. Diagnosed failed blower relay causing continuous blower operation and loss of heating function. Replaced defective relay, tested all safety controls, and verified proper ignition sequence and burner operation. System restored to normal heating operation with blower cycling correctly on thermostat demand.
Jibreel H.
Jibreel H. Checked in
Responded to no heat call on 20-year-old Carrier Weathermaker Infinity furnace with blower running continuously. Upon arrival, found system switched off by homeowner. Diagnosed failed blower relay causing continuous blower operation and loss of heating function. Replaced defective relay, tested all safety controls, and verified proper ignition sequence and burner operation. System restored to normal heating operation with blower cycling correctly on thermostat demand.
Barberton, OH 44203

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image