Schedule Service

Trusted HVAC, Plumbing & Electrical Services in Canton, OH

Hand changing the temperature on a boiler

Blind & Sons is proud to be Canton’s go-to provider for reliable, high-quality home services. For over 80 years, we’ve served Northeast Ohio with expert care and personalized service. From heating and cooling installations to fast plumbing repairs and advanced electrical upgrades, our certified team delivers comfort, safety, and peace of mind—every time.

Whether you live in a historic home downtown or a modern property in a growing neighborhood, we tailor every service to your home’s unique needs. When you’re ready to upgrade your HVAC system, repair a leaking pipe, or install an EV charger, Blind & Sons is the name Canton homeowners trust. Call 330-362-9232 today or contact us online to get started. 

Local Expertise for Canton, OH Homes

Home to the Pro Football Hall of Fame, the McKinley Monument, and a rich industrial legacy, Canton is one of Ohio’s most historic and vibrant cities. The area’s wide range of architecture and building ages—from early 1900s homes to newly built residences—requires a team that knows how to work with both modern systems and aging infrastructure.

At Blind & Sons, we bring specialized expertise, respect for Canton’s architectural diversity, and a commitment to keeping our local community safe and comfortable. We proudly serve neighborhoods throughout Stark County with solutions built to last.

Superior Plumbing Services in Canton

Plumbing problems can derail your day fast. At Blind & Sons, we make plumbing stress-free with fast diagnostics, clear pricing, and high-quality repairs. Whether it’s a clogged drain, low water pressure, or a complete water heater replacement, we’re the plumbing partner you can trust in Canton. Our plumbing services in Canton include:

  • Drain Cleaning: Advanced tools and techniques to eliminate clogs and restore flow in sinks, tubs, and sewer lines
  • Water Heater Services: We install, repair, and maintain both traditional tank and tankless water heaters
  • Gas Line Plumbing: Safe and professional gas line installation, inspection, and repairs for home appliances and systems
  • Sump Pump Services: Protect your basement from flooding with expert sump pump installation and maintenance
  • Fixture Repairs & Replacements: Toilets, sinks, faucets, garbage disposals, shutoff valves, and more

We deliver lasting plumbing solutions that keep your water clean, safe, and flowing efficiently year-round.

Need Services?

Top-Rated Electrical Services in Canton, OH

Whether you’re upgrading your electrical panel or planning to install a whole-home generator, Blind & Sons has the skills and experience to get the job done right. Our certified electricians in Canton deliver safe, code-compliant electrical work that meets Canton’s unique residential needs.

From small repairs to whole-home wiring projects, we bring power and peace of mind to Canton homes.

Canton Heating Repair & Replacement

When temperatures drop in Stark County, your heating system becomes more than a comfort—it’s a necessity. At Blind & Sons, we provide expert heating installation, maintenance, and repair services to keep your home warm all winter long.

We work with all major types of heating systems, including:

  • Furnaces: We repair and replace both gas and electric furnace systems
  • Boilers: We maintain and replace steam and hot water boilers for traditional radiant heat
  • Heat Pumps: Dual-function systems for year-round energy-efficient heating and cooling
  • Ductless HVAC Units: Perfect for home additions, garages, or homes without central ductwork

Not sure if your heating system needs repair or replacement? We’ll evaluate your setup and provide honest recommendations tailored to your home and budget.

Air Conditioning Services in Canton, OH

Heat pump unit outside a brick building

Ohio summers bring high heat and humidity. Blind & Sons offers fast, dependable air conditioning services to help you beat the heat and enjoy reliable indoor comfort. Whether you’re upgrading to a more energy-efficient model or need an emergency repair, our AC experts are ready to help.

  • AC Installation: We install central air systems, ductless mini-splits, and heat pump ACs sized specifically for your home
  • AC Replacement: Replace outdated units with modern, high-efficiency models that save money and reduce energy waste
  • Emergency AC Repair: Our technicians are available day and night to restore cooling as quickly as possible
  • AC Maintenance: Seasonal checkups and filter changes ensure maximum performance and system longevity

Stay cool and reduce your energy bills with optimized AC performance all summer long.

Need Services?

Why Canton Homeowners Choose Blind & Sons

For more than 85 years, Blind & Sons has been Canton’s trusted source for HVAC, plumbing, and electrical service. We’ve earned that trust through our unwavering commitment to high standards, ongoing training, and top-tier customer care.

Here’s what sets us apart:

  • 100% Satisfaction Guarantee—We won’t rest until you’re happy with our work
  • Certified, Background-Checked Technicians—Safety, expertise, and professionalism on every job
  • Upfront Pricing & No-Obligation Estimates—Know exactly what you’ll pay before work begins
  • Emergency HVAC Services—We’re always here when you need us
  • MVP Maintenance Plans—Year-round protection, priority service, and exclusive discounts
  • Community-Focused—We’re proud to support local events, schools, and charitable causes in Canton and throughout Stark County

We don’t just serve homes—we serve our neighbors.

Schedule Your Canton Home Services Today

Whether you’re facing a sudden AC failure, planning a new furnace installation, replacing a failing water heater, or upgrading your home’s lighting, Blind & Sons is here to help. With decades of experience and a team that truly cares, we’re proud to provide the top HVAC, plumbing, and electrical services in Canton, OH.

Call Blind & Sons at 330-362-9232 or contact us online now to schedule expert HVAC, plumbing, or electrical service in Canton, OH.

 

Recent Jobs and Reviews in Canton, OH

Canton, OH at a glance

Blind and Sons has completed 20 jobs in Canton, OH in May 2026.

The most recent job was on May 13, 2026.

Blind and Sons has completed 1,106 jobs in Canton, OH in the last 12 months.

Job Locations and Reviews

Conducted comprehensive on-site evaluation for complete furnace and air conditioning system replacement. Assessed existing gray furnace unit and associated ductwork in basement mechanical room, documenting current equipment specifications and configuration. Evaluated extensive moisture damage to foundation walls and deteriorating concrete surfaces that may impact equipment longevity and performance. Photographed existing HVAC installation including metallic supply ductwork, auxiliary air handling components, and copper refrigerant lines to determine proper sizing and configuration requirements for replacement system. Provided detailed equipment replacement estimate addressing current system deficiencies and environmental concerns in below-grade installation area.
Conducted comprehensive on-site evaluation for complete furnace and air conditioning system replacement. Assessed existing gray furnace unit and associated ductwork in basement mechanical room, documenting current equipment specifications and configuration. Evaluated extensive moisture damage to foundation walls and deteriorating concrete surfaces that may impact equipment longevity and performance. Photographed existing HVAC installation including metallic supply ductwork, auxiliary air handling components, and copper refrigerant lines to determine proper sizing and configuration requirements for replacement system. Provided detailed equipment replacement estimate addressing current system deficiencies and environmental concerns in below-grade installation area.
Jordan K.
Jordan K. Checked in
Conducted comprehensive on-site evaluation for complete furnace and air conditioning system replacement. Assessed existing gray furnace unit and associated ductwork in basement mechanical room, documenting current equipment specifications and configuration. Evaluated extensive moisture damage to foundation walls and deteriorating concrete surfaces that may impact equipment longevity and performance. Photographed existing HVAC installation including metallic supply ductwork, auxiliary air handling components, and copper refrigerant lines to determine proper sizing and configuration requirements for replacement system. Provided detailed equipment replacement estimate addressing current system deficiencies and environmental concerns in below-grade installation area.
Canton, OH 44707
Completed installation of 20kW whole home standby generator with 100-amp automatic transfer switch. Ran 30 feet of electrical conduit and wiring from main service panel to generator location, and installed 20 feet of gas line from existing supply to unit. Transfer switch was wired and configured to provide seamless power transition during outage conditions. All electrical connections were made per NEC code requirements and manufacturer specifications. Generator was positioned on pre-existing concrete pad, leveled, and secured. Gas line pressure tested and verified for proper operation. System startup performed successfully with transfer switch cycling tested under load. Unit programmed for weekly exercise cycle and all safety interlocks verified operational.
Completed installation of 20kW whole home standby generator with 100-amp automatic transfer switch. Ran 30 feet of electrical conduit and wiring from main service panel to generator location, and installed 20 feet of gas line from existing supply to unit. Transfer switch was wired and configured to provide seamless power transition during outage conditions. All electrical connections were made per NEC code requirements and manufacturer specifications. Generator was positioned on pre-existing concrete pad, leveled, and secured. Gas line pressure tested and verified for proper operation. System startup performed successfully with transfer switch cycling tested under load. Unit programmed for weekly exercise cycle and all safety interlocks verified operational.
Coby D.
Coby D. Checked in
Completed installation of 20kW whole home standby generator with 100-amp automatic transfer switch. Ran 30 feet of electrical conduit and wiring from main service panel to generator location, and installed 20 feet of gas line from existing supply to unit. Transfer switch was wired and configured to provide seamless power transition during outage conditions. All electrical connections were made per NEC code requirements and manufacturer specifications. Generator was positioned on pre-existing concrete pad, leveled, and secured. Gas line pressure tested and verified for proper operation. System startup performed successfully with transfer switch cycling tested under load. Unit programmed for weekly exercise cycle and all safety interlocks verified operational.
Canton, OH 44708
Performed preventive maintenance on 13-year-old Trane air conditioning system and furnace unit. Completed standard tune-up procedures including inspection of outdoor condenser unit, verification of electrical connections at disconnect box, and assessment of indoor furnace cabinet and flue pipe connections. All components found operating within normal parameters with no immediate service needs identified.
Performed preventive maintenance on 13-year-old Trane air conditioning system and furnace unit. Completed standard tune-up procedures including inspection of outdoor condenser unit, verification of electrical connections at disconnect box, and assessment of indoor furnace cabinet and flue pipe connections. All components found operating within normal parameters with no immediate service needs identified.
William S.
William S. Checked in
Performed preventive maintenance on 13-year-old Trane air conditioning system and furnace unit. Completed standard tune-up procedures including inspection of outdoor condenser unit, verification of electrical connections at disconnect box, and assessment of indoor furnace cabinet and flue pipe connections. All components found operating within normal parameters with no immediate service needs identified.
Canton, OH 44705
Conducted on-site assessment for tankless electric water heater installation in manufactured home. Evaluated existing electric storage tank water heater system, documented current plumbing configuration including PVC supply lines with brass compression fittings and shut-off valve, and assessed electrical requirements for conversion from conventional storage unit to tankless system. Photographed existing installation to determine necessary modifications for tankless unit compatibility and provided comprehensive estimate for equipment and installation.
Conducted on-site assessment for tankless electric water heater installation in manufactured home. Evaluated existing electric storage tank water heater system, documented current plumbing configuration including PVC supply lines with brass compression fittings and shut-off valve, and assessed electrical requirements for conversion from conventional storage unit to tankless system. Photographed existing installation to determine necessary modifications for tankless unit compatibility and provided comprehensive estimate for equipment and installation.
Travis B.
Travis B. Checked in
Conducted on-site assessment for tankless electric water heater installation in manufactured home. Evaluated existing electric storage tank water heater system, documented current plumbing configuration including PVC supply lines with brass compression fittings and shut-off valve, and assessed electrical requirements for conversion from conventional storage unit to tankless system. Photographed existing installation to determine necessary modifications for tankless unit compatibility and provided comprehensive estimate for equipment and installation.
Canton, OH 44705
Completed scheduled MVP cooling maintenance visit on Carrier Weather Maker 9200 ultra-efficient gas furnace system with Space Guard high-efficiency air cleaner. Replaced April Aire filter media (STK#201) as requested. Inspected outdoor condensing unit positioned against exterior brick wall, noting vegetation growth around base that may require future clearance for optimal airflow. Verified electrical connections at junction box and indoor components, documented system condition with photos, and confirmed all equipment operating within normal parameters.
Completed scheduled MVP cooling maintenance visit on Carrier Weather Maker 9200 ultra-efficient gas furnace system with Space Guard high-efficiency air cleaner. Replaced April Aire filter media (STK#201) as requested. Inspected outdoor condensing unit positioned against exterior brick wall, noting vegetation growth around base that may require future clearance for optimal airflow. Verified electrical connections at junction box and indoor components, documented system condition with photos, and confirmed all equipment operating within normal parameters.
Taylor F.
Taylor F. Checked in
Completed scheduled MVP cooling maintenance visit on Carrier Weather Maker 9200 ultra-efficient gas furnace system with Space Guard high-efficiency air cleaner. Replaced April Aire filter media (STK#201) as requested. Inspected outdoor condensing unit positioned against exterior brick wall, noting vegetation growth around base that may require future clearance for optimal airflow. Verified electrical connections at junction box and indoor components, documented system condition with photos, and confirmed all equipment operating within normal parameters.
Canton, OH 44718
Completed scheduled maintenance inspection on 22-year-old Lennox furnace system located in basement utility area. Performed standard heating season preventive maintenance procedures including visual inspection of unit cabinet, ductwork connections, and venting systems. All components inspected and found to be operating within normal parameters, with unit showing typical age-related wear but no immediate service concerns identified.
Completed scheduled maintenance inspection on 22-year-old Lennox furnace system located in basement utility area. Performed standard heating season preventive maintenance procedures including visual inspection of unit cabinet, ductwork connections, and venting systems. All components inspected and found to be operating within normal parameters, with unit showing typical age-related wear but no immediate service concerns identified.
William S.
William S. Checked in
Completed scheduled maintenance inspection on 22-year-old Lennox furnace system located in basement utility area. Performed standard heating season preventive maintenance procedures including visual inspection of unit cabinet, ductwork connections, and venting systems. All components inspected and found to be operating within normal parameters, with unit showing typical age-related wear but no immediate service concerns identified.
Canton, OH 44705
Conducted on-site evaluation for add-on air conditioning system to existing Concord furnace installation in residential basement mechanical room. Assessed current HVAC infrastructure including ductwork configuration, available space for evaporator coil placement, electrical service capacity, and optimal refrigerant line routing to exterior condensing unit location. Documented existing forced-air heating system and determined compatibility requirements for integrated cooling system installation.
Conducted on-site evaluation for add-on air conditioning system to existing Concord furnace installation in residential basement mechanical room. Assessed current HVAC infrastructure including ductwork configuration, available space for evaporator coil placement, electrical service capacity, and optimal refrigerant line routing to exterior condensing unit location. Documented existing forced-air heating system and determined compatibility requirements for integrated cooling system installation.
Jordan K.
Jordan K. Checked in
Conducted on-site evaluation for add-on air conditioning system to existing Concord furnace installation in residential basement mechanical room. Assessed current HVAC infrastructure including ductwork configuration, available space for evaporator coil placement, electrical service capacity, and optimal refrigerant line routing to exterior condensing unit location. Documented existing forced-air heating system and determined compatibility requirements for integrated cooling system installation.
Canton, OH 44708
Responded to service call for leaking water tank in 27-year-old residential property. Upon inspection, identified leak originating from pressure tank assembly and associated brass fittings in basement utility area. The existing expansion tank, which had been in service for approximately eight years, showed signs of failure at connection points. Evaluated pressure gauge readings and tested system integrity. Addressed leak source, inspected copper piping and PEX water line connections, and verified proper drainage catchment was in place beneath plumbing assembly to prevent water damage.
Responded to service call for leaking water tank in 27-year-old residential property. Upon inspection, identified leak originating from pressure tank assembly and associated brass fittings in basement utility area. The existing expansion tank, which had been in service for approximately eight years, showed signs of failure at connection points. Evaluated pressure gauge readings and tested system integrity. Addressed leak source, inspected copper piping and PEX water line connections, and verified proper drainage catchment was in place beneath plumbing assembly to prevent water damage.
Travis B.
Travis B. Checked in
Responded to service call for leaking water tank in 27-year-old residential property. Upon inspection, identified leak originating from pressure tank assembly and associated brass fittings in basement utility area. The existing expansion tank, which had been in service for approximately eight years, showed signs of failure at connection points. Evaluated pressure gauge readings and tested system integrity. Addressed leak source, inspected copper piping and PEX water line connections, and verified proper drainage catchment was in place beneath plumbing assembly to prevent water damage.
Canton, OH 44714
Responded to generator shutdown displaying error code 3503 (Engine Intake Manifold 1 Temperature - Low intake manifold temperature alarm). Upon arrival, inspected Mercedes-Benz manufactured generator unit housed in protective enclosure. Performed diagnostic assessment of intake manifold temperature sensor and associated wiring harness. Verified sensor connections, checked for proper voltage readings, and examined the corrugated protective conduit for any damage or environmental intrusion that could affect sensor performance. Documented equipment condition through photographic records showing generator control panel with indicator lights and engine compartment components. Generator operational status restored and customer notified of completed repairs with explanation of work performed.
Responded to generator shutdown displaying error code 3503 (Engine Intake Manifold 1 Temperature - Low intake manifold temperature alarm). Upon arrival, inspected Mercedes-Benz manufactured generator unit housed in protective enclosure. Performed diagnostic assessment of intake manifold temperature sensor and associated wiring harness. Verified sensor connections, checked for proper voltage readings, and examined the corrugated protective conduit for any damage or environmental intrusion that could affect sensor performance. Documented equipment condition through photographic records showing generator control panel with indicator lights and engine compartment components. Generator operational status restored and customer notified of completed repairs with explanation of work performed.
Matthew H.
Matthew H. Checked in
Responded to generator shutdown displaying error code 3503 (Engine Intake Manifold 1 Temperature - Low intake manifold temperature alarm). Upon arrival, inspected Mercedes-Benz manufactured generator unit housed in protective enclosure. Performed diagnostic assessment of intake manifold temperature sensor and associated wiring harness. Verified sensor connections, checked for proper voltage readings, and examined the corrugated protective conduit for any damage or environmental intrusion that could affect sensor performance. Documented equipment condition through photographic records showing generator control panel with indicator lights and engine compartment components. Generator operational status restored and customer notified of completed repairs with explanation of work performed.
Canton, OH 44718
Completed MVP cooling maintenance visit on residential Lennox system. Performed comprehensive inspection of outdoor condenser unit and indoor furnace assembly, verified proper operation of all components, documented equipment condition through photographic records, and confirmed system is operating within normal parameters for continued seasonal performance.
Completed MVP cooling maintenance visit on residential Lennox system. Performed comprehensive inspection of outdoor condenser unit and indoor furnace assembly, verified proper operation of all components, documented equipment condition through photographic records, and confirmed system is operating within normal parameters for continued seasonal performance.
William S.
William S. Checked in
Completed MVP cooling maintenance visit on residential Lennox system. Performed comprehensive inspection of outdoor condenser unit and indoor furnace assembly, verified proper operation of all components, documented equipment condition through photographic records, and confirmed system is operating within normal parameters for continued seasonal performance.
Canton, OH 44718
Performed comprehensive cooling system maintenance on residential HVAC unit. Thoroughly cleaned heavily soiled outdoor condenser coil which had significant accumulation of dirt, dust, and debris between fins that was restricting airflow and reducing system efficiency. Inspected indoor evaporator coil assembly, refrigerant lines, copper piping, electrical connections, and associated components to ensure proper operation and system integrity.
Performed comprehensive cooling system maintenance on residential HVAC unit. Thoroughly cleaned heavily soiled outdoor condenser coil which had significant accumulation of dirt, dust, and debris between fins that was restricting airflow and reducing system efficiency. Inspected indoor evaporator coil assembly, refrigerant lines, copper piping, electrical connections, and associated components to ensure proper operation and system integrity.
Taylor F.
Taylor F. Checked in
Performed comprehensive cooling system maintenance on residential HVAC unit. Thoroughly cleaned heavily soiled outdoor condenser coil which had significant accumulation of dirt, dust, and debris between fins that was restricting airflow and reducing system efficiency. Inspected indoor evaporator coil assembly, refrigerant lines, copper piping, electrical connections, and associated components to ensure proper operation and system integrity.
Canton, OH 44721
Responded to service call for leak repair in basement of 69-year-old vacant single-family home scheduled for sale. Upon arrival, accessed property and conducted thorough inspection of plumbing systems in basement and crawl space areas.

Discovered extensive corrosion on copper supply lines in crawl space, with significant green-blue patina (verdigris) indicating advanced deterioration. Main horizontal copper pipe exhibited rough, bumpy texture with turquoise discoloration covering substantial section. Blue-handled shutoff valve showed dark staining and corrosion around base and connection points. Secondary diagonal copper pipe also displayed patches of green corrosion consistent with aging plumbing system.

Inspected kitchen sink cabinet area and found double sink drain system with white PVC trap configuration. Examined chrome sink strainers, flexible braided supply lines, and associated drain connections. Noted dark spots on cabinet floor but determined these were pre-existing stains
Responded to service call for leak repair in basement of 69-year-old vacant single-family home scheduled for sale. Upon arrival, accessed property and conducted thorough inspection of plumbing systems in basement and crawl space areas.

Discovered extensive corrosion on copper supply lines in crawl space, with significant green-blue patina (verdigris) indicating advanced deterioration. Main horizontal copper pipe exhibited rough, bumpy texture with turquoise discoloration covering substantial section. Blue-handled shutoff valve showed dark staining and corrosion around base and connection points. Secondary diagonal copper pipe also displayed patches of green corrosion consistent with aging plumbing system.

Inspected kitchen sink cabinet area and found double sink drain system with white PVC trap configuration. Examined chrome sink strainers, flexible braided supply lines, and associated drain connections. Noted dark spots on cabinet floor but determined these were pre-existing stains
Mark W.
Mark W. Checked in
Responded to service call for leak repair in basement of 69-year-old vacant single-family home scheduled for sale. Upon arrival, accessed property and conducted thorough inspection of plumbing systems in basement and crawl space areas. Discovered extensive corrosion on copper supply lines in crawl space, with significant green-blue patina (verdigris) indicating advanced deterioration. Main horizontal copper pipe exhibited rough, bumpy texture with turquoise discoloration covering substantial section. Blue-handled shutoff valve showed dark staining and corrosion around base and connection points. Secondary diagonal copper pipe also displayed patches of green corrosion consistent with aging plumbing system. Inspected kitchen sink cabinet area and found double sink drain system with white PVC trap configuration. Examined chrome sink strainers, flexible braided supply lines, and associated drain connections. Noted dark spots on cabinet floor but determined these were pre-existing stains
Canton, OH 44706
Completed comprehensive tune-up on 10-year-old residential air conditioning system. Performed standard maintenance procedures including inspection of condenser unit, electrical disconnect, and refrigerant lines. Evaluated concrete pad condition beneath outdoor unit as requested by customer and documented foundation area with gravel bedding, PVC condensate drain line with proper venting, and electrical connections to ensure system stability and proper drainage.
Completed comprehensive tune-up on 10-year-old residential air conditioning system. Performed standard maintenance procedures including inspection of condenser unit, electrical disconnect, and refrigerant lines. Evaluated concrete pad condition beneath outdoor unit as requested by customer and documented foundation area with gravel bedding, PVC condensate drain line with proper venting, and electrical connections to ensure system stability and proper drainage.
John W.
John W. Checked in
Completed comprehensive tune-up on 10-year-old residential air conditioning system. Performed standard maintenance procedures including inspection of condenser unit, electrical disconnect, and refrigerant lines. Evaluated concrete pad condition beneath outdoor unit as requested by customer and documented foundation area with gravel bedding, PVC condensate drain line with proper venting, and electrical connections to ensure system stability and proper drainage.
Canton, OH 44708
Responded to furnace lockout issue with error code that would clear when access panel was removed. Upon arrival, performed diagnostic testing and measured supply air temperature at 72°F. Inspected inducer motor assembly and associated wiring connections, which appeared to be the source of the intermittent fault. Determined that door safety switch was likely causing nuisance shutdowns due to improper contact or alignment. Verified all electrical connections were secure and tested system operation through multiple cycles with panel properly installed to confirm reliable operation without further error codes.
Responded to furnace lockout issue with error code that would clear when access panel was removed. Upon arrival, performed diagnostic testing and measured supply air temperature at 72°F. Inspected inducer motor assembly and associated wiring connections, which appeared to be the source of the intermittent fault. Determined that door safety switch was likely causing nuisance shutdowns due to improper contact or alignment. Verified all electrical connections were secure and tested system operation through multiple cycles with panel properly installed to confirm reliable operation without further error codes.
William S.
William S. Checked in
Responded to furnace lockout issue with error code that would clear when access panel was removed. Upon arrival, performed diagnostic testing and measured supply air temperature at 72°F. Inspected inducer motor assembly and associated wiring connections, which appeared to be the source of the intermittent fault. Determined that door safety switch was likely causing nuisance shutdowns due to improper contact or alignment. Verified all electrical connections were secure and tested system operation through multiple cycles with panel properly installed to confirm reliable operation without further error codes.
Canton, OH 44709
Performed preventative maintenance on 22-year-old residential air conditioning system. Completed comprehensive tune-up including inspection of outdoor condenser unit, capacitor testing and evaluation, refrigerant line connections, and electrical components. All system components operational at time of service completion.
Performed preventative maintenance on 22-year-old residential air conditioning system. Completed comprehensive tune-up including inspection of outdoor condenser unit, capacitor testing and evaluation, refrigerant line connections, and electrical components. All system components operational at time of service completion.
Jibreel H.
Jibreel H. Checked in
Performed preventative maintenance on 22-year-old residential air conditioning system. Completed comprehensive tune-up including inspection of outdoor condenser unit, capacitor testing and evaluation, refrigerant line connections, and electrical components. All system components operational at time of service completion.
Canton, OH 44714
Completed annual maintenance on 22-year-old DUOSTAR furnace system located in basement of duplex residence. Performed comprehensive tune-up including inspection of heat exchanger, burner assembly, ignition system, and all safety controls. Verified proper operation of venting system and condensate drainage lines, checked all electrical connections, and tested system startup and shutdown cycles to ensure safe and efficient operation.
Completed annual maintenance on 22-year-old DUOSTAR furnace system located in basement of duplex residence. Performed comprehensive tune-up including inspection of heat exchanger, burner assembly, ignition system, and all safety controls. Verified proper operation of venting system and condensate drainage lines, checked all electrical connections, and tested system startup and shutdown cycles to ensure safe and efficient operation.
Jibreel H.
Jibreel H. Checked in
Completed annual maintenance on 22-year-old DUOSTAR furnace system located in basement of duplex residence. Performed comprehensive tune-up including inspection of heat exchanger, burner assembly, ignition system, and all safety controls. Verified proper operation of venting system and condensate drainage lines, checked all electrical connections, and tested system startup and shutdown cycles to ensure safe and efficient operation.
Canton, OH 44714
Completed comprehensive MVP cooling maintenance on Lennox HVAC system. Performed thorough inspection of unit components, control boards, electrical connections, and wiring harnesses. Verified proper operation of all system controls, condensate drain lines, and ventilation piping. All components found to be in good working condition with no issues identified.
Completed comprehensive MVP cooling maintenance on Lennox HVAC system. Performed thorough inspection of unit components, control boards, electrical connections, and wiring harnesses. Verified proper operation of all system controls, condensate drain lines, and ventilation piping. All components found to be in good working condition with no issues identified.
Jesus M.
Jesus M. Checked in
Completed comprehensive MVP cooling maintenance on Lennox HVAC system. Performed thorough inspection of unit components, control boards, electrical connections, and wiring harnesses. Verified proper operation of all system controls, condensate drain lines, and ventilation piping. All components found to be in good working condition with no issues identified.
Canton, OH 44706
Conducted on-site evaluation for HVAC furnace replacement in residential basement utility area. Assessed existing AIREASE brand furnace unit, documented current installation including metal ductwork configuration, PVC condensate drain and venting system, and electrical control components. Evaluated mechanical room layout and existing infrastructure to determine replacement requirements. Photographed equipment specifications, duct connections, and surrounding plumbing work including exposed wall section with PVC and black pipe assemblies to ensure accurate replacement planning and proper clearances for new installation.
Conducted on-site evaluation for HVAC furnace replacement in residential basement utility area. Assessed existing AIREASE brand furnace unit, documented current installation including metal ductwork configuration, PVC condensate drain and venting system, and electrical control components. Evaluated mechanical room layout and existing infrastructure to determine replacement requirements. Photographed equipment specifications, duct connections, and surrounding plumbing work including exposed wall section with PVC and black pipe assemblies to ensure accurate replacement planning and proper clearances for new installation.
Jordan K.
Jordan K. Checked in
Conducted on-site evaluation for HVAC furnace replacement in residential basement utility area. Assessed existing AIREASE brand furnace unit, documented current installation including metal ductwork configuration, PVC condensate drain and venting system, and electrical control components. Evaluated mechanical room layout and existing infrastructure to determine replacement requirements. Photographed equipment specifications, duct connections, and surrounding plumbing work including exposed wall section with PVC and black pipe assemblies to ensure accurate replacement planning and proper clearances for new installation.
Canton, OH 44718
Completed scheduled MVP cooling maintenance visit on 3-year-old HVAC system. Inspected evaporator coil assembly and found unit in good operating condition with clean coil surfaces showing proper airflow pattern through diamond mesh media. Removed and inspected air filter, which showed minimal debris accumulation; reinstalled pleated filter in proper orientation within mounting bracket to ensure optimal system performance and air quality.
Completed scheduled MVP cooling maintenance visit on 3-year-old HVAC system. Inspected evaporator coil assembly and found unit in good operating condition with clean coil surfaces showing proper airflow pattern through diamond mesh media. Removed and inspected air filter, which showed minimal debris accumulation; reinstalled pleated filter in proper orientation within mounting bracket to ensure optimal system performance and air quality.
Colton D.
Colton D. Checked in
Completed scheduled MVP cooling maintenance visit on 3-year-old HVAC system. Inspected evaporator coil assembly and found unit in good operating condition with clean coil surfaces showing proper airflow pattern through diamond mesh media. Removed and inspected air filter, which showed minimal debris accumulation; reinstalled pleated filter in proper orientation within mounting bracket to ensure optimal system performance and air quality.
Canton, OH 44721
Completed MVP recurring cooling maintenance visit. Performed thorough inspection of indoor evaporator coil assembly, confirming proper fin condition and cleanliness with no significant debris accumulation noted. Inspected and evaluated air filtration system, verifying filters are properly seated within the air handler compartment and maintaining adequate airflow for optimal system performance.
Completed MVP recurring cooling maintenance visit. Performed thorough inspection of indoor evaporator coil assembly, confirming proper fin condition and cleanliness with no significant debris accumulation noted. Inspected and evaluated air filtration system, verifying filters are properly seated within the air handler compartment and maintaining adequate airflow for optimal system performance.
Jesus M.
Jesus M. Checked in
Completed MVP recurring cooling maintenance visit. Performed thorough inspection of indoor evaporator coil assembly, confirming proper fin condition and cleanliness with no significant debris accumulation noted. Inspected and evaluated air filtration system, verifying filters are properly seated within the air handler compartment and maintaining adequate airflow for optimal system performance.
Canton, OH 44705

 

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image