Schedule Service

HVAC, Electrical & Plumbing Services in Hinckley, OH

Whole-home generator in front of HVAC units

Your home in Hinckley works hard to keep you comfortable and safe day in and day out. When your HVAC, plumbing, or electrical systems encounter problems, you deserve a dependable team that can deliver solutions fast. Blind & Sons has been the trusted name for home services in Northeast Ohio for over 80 years, and we’re proud to bring our full suite of services to the Hinckley community.

From HVAC emergencies to routine maintenance, electrical upgrades to plumbing repairs, we handle it all with care, professionalism, and a commitment to your satisfaction.

Call Blind & Sons at 330-362-9232 to schedule expert home services in Hinckley, OH.

Personalized Service for Hinckley Residents

Hinckley, Ohio is a town that balances serene living with a strong sense of community. Known for its picturesque landscapes and the iconic Hinckley Reservation—a part of the Cleveland Metroparks system—this area is a haven for outdoor enthusiasts. Families flock to enjoy hiking trails, scenic views, and the yearly celebration of Buzzard Day, which honors the return of buzzards every March. With its charming blend of rural beauty and suburban growth, Hinckley is a place where modern living meets natural retreat.

Homes throughout Hinckley vary from historic farmhouses along State Road to new developments near Bellus Road, each presenting its own unique set of needs. At Blind & Sons, we understand the intricacies of serving this diverse housing landscape. Whether you’re living in a century-old home with aging plumbing or a new build requiring smart electrical upgrades, our team delivers solutions designed specifically for Hinckley residents. With deep knowledge of the area and a reputation built on trust, we offer services tailored to your home, your lifestyle, and your community.

Need Services?

Hinckley Heating Services to Keep You Warm and Worry-Free

Ohio winters can be unforgiving, and a failing heating system can quickly turn your home into an uncomfortable and even unsafe place. At Blind & Sons, we provide comprehensive heating services in Hinckley to keep your space warm and efficient:

Cooling Services in Hinckley for Ohio’s Hottest Days

Hot summer temperatures can quickly become unbearable without a properly functioning AC system. Our cooling services in Hinckley are designed to ensure your home remains a sanctuary of comfort, even during heatwaves:

Indoor Air Quality Services in Hinckley, OH

Many homeowners overlook their indoor air quality, but it’s a crucial part of your overall comfort and health. At Blind & Sons, we offer a full range of IAQ solutions that reduce airborne contaminants and create a healthier home environment:

Professional Electrical Services in Hinckley for Safe & Modern Living

Electrical issues can be both inconvenient and hazardous. Whether you’re looking to upgrade your system or fix an urgent issue, Blind & Sons has you covered. Our licensed electricians provide safe, code-compliant solutions, including:

Need Services?

Expert Plumbing Services in Hinckley, OH

Water HeaterInstallation

A minor plumbing issue can quickly escalate into a major hassle. Don’t wait until a leak causes costly damage—call Blind & Sons for reliable plumbing solutions that keep your home dry and functional:

Why Choose Blind & Sons in Hinckley?

When you call Blind & Sons, you’re partnering with a team that puts your home, time, and peace of mind first. Here’s why Hinckley residents trust us again and again:

  • Over 80 Years of Service Excellence: A legacy built on quality, professionalism, and customer satisfaction.
  • Certified, Background-Checked Technicians: Courteous, qualified experts who respect your time and your home.
  • Emergency Service Without Overtime Fees: Day or night, we’re here when you need us—without hidden costs.
  • Transparent, Upfront Pricing: No surprises—just honest, clear communication.
  • 100% Satisfaction Guarantee: We don’t consider the job done until you’re completely happy.
  • MVP Maintenance Program: Prevent breakdowns and save on repairs with scheduled service and exclusive benefits.

Schedule Trusted Home Services in Hinckley Today

Whether you’re facing a system failure or planning an upgrade, Blind & Sons is ready to help. Our commitment to reliable, high-quality service has made us the go-to provider for HVAC, plumbing, and electrical services throughout Hinckley and beyond.

Call 330-362-9232 or contact us online to schedule professional home services in Hinckley, OH. Discover the Blind & Sons difference today.

 

Recent Jobs and Reviews in Hinckley, OH

Hinckley, OH at a glance

Blind and Sons has completed 20 jobs in Hinckley, OH between April 2026 and August 2026.

The most recent job was on August 21, 2026.

Blind and Sons has completed 54 jobs in Hinckley, OH in the last 12 months.

Job Locations and Reviews

Hinckley, OH - Responded to service call for A/C unit short cycling every 4 minutes, 13 days post-installation. Upon inspection, identified issue with the control board and thermostat communication. Verified all wiring connections at the control module terminal block, checked thermostat status indicators showing proper power and communication signals, and confirmed the wireless setup module was functioning correctly. Addressed the short cycling issue by reconfiguring the control board settings and ensuring proper sensor operation. System tested and verified to be operating within normal parameters with appropriate run cycles restored.
Frank W.
Frank W. Checked in
Responded to service call for A/C unit short cycling every 4 minutes, 13 days post-installation. Upon inspection, identified issue with the control board and thermostat communication. Verified all wiring connections at the control module terminal block, checked thermostat status indicators showing proper power and communication signals, and confirmed the wireless setup module was functioning correctly. Addressed the short cycling issue by reconfiguring the control board settings and ensuring proper sensor operation. System tested and verified to be operating within normal parameters with appropriate run cycles restored.
Hinckley, OH 44233
Hinckley, OH - Responded to emergency call for damaged underground utilities. During excavation work, both water and electrical lines running to the septic system were struck and compromised. Successfully repaired the damaged water line on-site. Electrical line remains damaged and requires follow-up service, as it may be heat tape which can be addressed by plumbing technician.
Travis B.
Travis B. Checked in
Responded to emergency call for damaged underground utilities. During excavation work, both water and electrical lines running to the septic system were struck and compromised. Successfully repaired the damaged water line on-site. Electrical line remains damaged and requires follow-up service, as it may be heat tape which can be addressed by plumbing technician.
Hinckley, OH 44233
Hinckley, OH - Responded to failed electrical inspection for generator installation. Corrected undersized seal tight connector at generator knockout to prevent water intrusion and installed proper size straps on seal tight conduit. Upgraded number 4 copper conductor to appropriately rated wire for 100-amp service. Documented existing electrical panel configuration showing main breaker section and distribution breakers with conduit routing. Awaiting delivery of 2-pole breaker to complete final connection.
Logan H.
Logan H. Checked in
Responded to failed electrical inspection for generator installation. Corrected undersized seal tight connector at generator knockout to prevent water intrusion and installed proper size straps on seal tight conduit. Upgraded number 4 copper conductor to appropriately rated wire for 100-amp service. Documented existing electrical panel configuration showing main breaker section and distribution breakers with conduit routing. Awaiting delivery of 2-pole breaker to complete final connection.
Hinckley, OH 44233
Hinckley, OH - Responded to no-cooling complaint on 3-year-old residential air conditioning system. Upon arrival, connected manifold gauges to measure refrigerant pressures and utilized digital instruments to diagnose the condenser unit. System was found to have improper refrigerant charge affecting cooling performance. Corrected refrigerant levels to manufacturer specifications, verified proper operation of condenser fan and compressor, and restored unit to normal cooling function.
Frank W.
Frank W. Checked in
Responded to no-cooling complaint on 3-year-old residential air conditioning system. Upon arrival, connected manifold gauges to measure refrigerant pressures and utilized digital instruments to diagnose the condenser unit. System was found to have improper refrigerant charge affecting cooling performance. Corrected refrigerant levels to manufacturer specifications, verified proper operation of condenser fan and compressor, and restored unit to normal cooling function.
Hinckley, OH 44233
Completed annual maintenance on one-year-old air conditioning system, performing standard inspection and servicing of outdoor condensing unit. Provided homeowner education on proper air filter replacement procedures and demonstrated condensate drain line maintenance using distilled white vinegar flush method to prevent future clogs and ensure optimal system performance.
Completed annual maintenance on one-year-old air conditioning system, performing standard inspection and servicing of outdoor condensing unit. Provided homeowner education on proper air filter replacement procedures and demonstrated condensate drain line maintenance using distilled white vinegar flush method to prevent future clogs and ensure optimal system performance.
Colton D.
Colton D. Checked in
Completed annual maintenance on one-year-old air conditioning system, performing standard inspection and servicing of outdoor condensing unit. Provided homeowner education on proper air filter replacement procedures and demonstrated condensate drain line maintenance using distilled white vinegar flush method to prevent future clogs and ensure optimal system performance.
Hinckley, OH 44233
Hinckley, OH - Responded to service call for gas fireplace pilot light issues. Successfully relit pilot lights on two gas fireplaces in residence and verified proper ignition and flame operation on both units.
Mark W.
Mark W. Checked in
Responded to service call for gas fireplace pilot light issues. Successfully relit pilot lights on two gas fireplaces in residence and verified proper ignition and flame operation on both units.
Hinckley, OH 44233
Successfully installed a 28kW Generac generator system with dual 200-amp automatic transfer switches to provide comprehensive backup power coverage for the residence. Installation included integration of cold weather protection kit with oil heater, dual load shed modules for prioritized power management, and two slow start kits to minimize startup surge demands on the system. Coordinated with gas line contractor for 30-foot natural gas supply line installation to fuel source. Mounted generator unit on exterior pad adjacent to stone facade wall, routing electrical conduit and gas piping along building exterior to minimize visual impact. Installed grey conduit vertically down stone wall corner with proper weatherproof fittings and junction boxes for code-compliant electrical connections. Configured both transfer switches to automatically detect utility power loss and seamlessly transfer critical circuits to generator power. Programmed load shed controllers to sequence non-essential loads
Successfully installed a 28kW Generac generator system with dual 200-amp automatic transfer switches to provide comprehensive backup power coverage for the residence. Installation included integration of cold weather protection kit with oil heater, dual load shed modules for prioritized power management, and two slow start kits to minimize startup surge demands on the system. Coordinated with gas line contractor for 30-foot natural gas supply line installation to fuel source. Mounted generator unit on exterior pad adjacent to stone facade wall, routing electrical conduit and gas piping along building exterior to minimize visual impact. Installed grey conduit vertically down stone wall corner with proper weatherproof fittings and junction boxes for code-compliant electrical connections. Configured both transfer switches to automatically detect utility power loss and seamlessly transfer critical circuits to generator power. Programmed load shed controllers to sequence non-essential loads
Generator
Generator Checked in
Successfully installed a 28kW Generac generator system with dual 200-amp automatic transfer switches to provide comprehensive backup power coverage for the residence. Installation included integration of cold weather protection kit with oil heater, dual load shed modules for prioritized power management, and two slow start kits to minimize startup surge demands on the system. Coordinated with gas line contractor for 30-foot natural gas supply line installation to fuel source. Mounted generator unit on exterior pad adjacent to stone facade wall, routing electrical conduit and gas piping along building exterior to minimize visual impact. Installed grey conduit vertically down stone wall corner with proper weatherproof fittings and junction boxes for code-compliant electrical connections. Configured both transfer switches to automatically detect utility power loss and seamlessly transfer critical circuits to generator power. Programmed load shed controllers to sequence non-essential loads
Hinckley, OH 44233
Hinckley, OH - Completed installation of new Lennox 90% efficiency air conditioning system. Installed FLNR 45 amp fuses in outdoor disconnect for proper overcurrent protection of the condenser unit. System tested and operational upon completion.
Charles A.
Charles A. Checked in
Completed installation of new Lennox 90% efficiency air conditioning system. Installed FLNR 45 amp fuses in outdoor disconnect for proper overcurrent protection of the condenser unit. System tested and operational upon completion.
Hinckley, OH 44233
Conducted on-site evaluation for whole-house standby generator installation. Assessed existing electrical service panel to determine compatibility and required modifications for generator integration. Panel inspection revealed 200-amp main service with adequate breaker capacity and proper circuit identification for essential loads. Documented current electrical configuration including HVAC systems, garage circuits, and critical household loads to establish transfer switch requirements. Photographed electrical panel layout and circuit distribution for accurate material estimation and permit preparation. Provided homeowner with recommendations for generator sizing based on existing electrical demand and discussed placement options for outdoor generator unit and automatic transfer switch installation.
Conducted on-site evaluation for whole-house standby generator installation. Assessed existing electrical service panel to determine compatibility and required modifications for generator integration. Panel inspection revealed 200-amp main service with adequate breaker capacity and proper circuit identification for essential loads. Documented current electrical configuration including HVAC systems, garage circuits, and critical household loads to establish transfer switch requirements. Photographed electrical panel layout and circuit distribution for accurate material estimation and permit preparation. Provided homeowner with recommendations for generator sizing based on existing electrical demand and discussed placement options for outdoor generator unit and automatic transfer switch installation.
Eric L.
Eric L. Checked in
Conducted on-site evaluation for whole-house standby generator installation. Assessed existing electrical service panel to determine compatibility and required modifications for generator integration. Panel inspection revealed 200-amp main service with adequate breaker capacity and proper circuit identification for essential loads. Documented current electrical configuration including HVAC systems, garage circuits, and critical household loads to establish transfer switch requirements. Photographed electrical panel layout and circuit distribution for accurate material estimation and permit preparation. Provided homeowner with recommendations for generator sizing based on existing electrical demand and discussed placement options for outdoor generator unit and automatic transfer switch installation.
Hinckley, OH 44233
Conducted comprehensive estimate for furnace and air conditioning system replacement at residential property. Customer reported unusually high utility bills and history of multiple refrigerant recharges by previous service provider. Evaluated existing Carrier furnace installation and associated air conditioning system, documenting current equipment configuration including PVC venting, electrical connections, and ductwork integration. Assessed system performance concerns and provided replacement options to address ongoing efficiency issues and repeated refrigerant loss indicating potential system failure.
Conducted comprehensive estimate for furnace and air conditioning system replacement at residential property. Customer reported unusually high utility bills and history of multiple refrigerant recharges by previous service provider. Evaluated existing Carrier furnace installation and associated air conditioning system, documenting current equipment configuration including PVC venting, electrical connections, and ductwork integration. Assessed system performance concerns and provided replacement options to address ongoing efficiency issues and repeated refrigerant loss indicating potential system failure.
Kevin T.
Kevin T. Checked in
Conducted comprehensive estimate for furnace and air conditioning system replacement at residential property. Customer reported unusually high utility bills and history of multiple refrigerant recharges by previous service provider. Evaluated existing Carrier furnace installation and associated air conditioning system, documenting current equipment configuration including PVC venting, electrical connections, and ductwork integration. Assessed system performance concerns and provided replacement options to address ongoing efficiency issues and repeated refrigerant loss indicating potential system failure.
Hinckley, OH 44233
Installed new gas line from main residence to pool and barn area to replace previously severed line. Trenched and ran new gas piping underground across property, connecting to existing gas supply at the home. Installed appropriate shutoff valves and flexible connectors at termination points, ensuring proper support and mounting of exposed pipe sections at structure connections.
Installed new gas line from main residence to pool and barn area to replace previously severed line. Trenched and ran new gas piping underground across property, connecting to existing gas supply at the home. Installed appropriate shutoff valves and flexible connectors at termination points, ensuring proper support and mounting of exposed pipe sections at structure connections.
Nick L.
Nick L. Checked in
Installed new gas line from main residence to pool and barn area to replace previously severed line. Trenched and ran new gas piping underground across property, connecting to existing gas supply at the home. Installed appropriate shutoff valves and flexible connectors at termination points, ensuring proper support and mounting of exposed pipe sections at structure connections.
Hinckley, OH 44233
Conducted on-site evaluation for whole home generator installation. Assessed basement utility area to determine electrical service capacity, available space for transfer switch installation, and proper routing for electrical conduit from main service panel. Evaluated attic space to identify optimal location for generator connection and reviewed existing electrical infrastructure. Documented current water heater, plumbing, and HVAC configurations to ensure proper clearances and code compliance for generator placement. Photographed electrical panel access points and structural considerations for load calculation and equipment sizing recommendations.
Conducted on-site evaluation for whole home generator installation. Assessed basement utility area to determine electrical service capacity, available space for transfer switch installation, and proper routing for electrical conduit from main service panel. Evaluated attic space to identify optimal location for generator connection and reviewed existing electrical infrastructure. Documented current water heater, plumbing, and HVAC configurations to ensure proper clearances and code compliance for generator placement. Photographed electrical panel access points and structural considerations for load calculation and equipment sizing recommendations.
Eric L.
Eric L. Checked in
Conducted on-site evaluation for whole home generator installation. Assessed basement utility area to determine electrical service capacity, available space for transfer switch installation, and proper routing for electrical conduit from main service panel. Evaluated attic space to identify optimal location for generator connection and reviewed existing electrical infrastructure. Documented current water heater, plumbing, and HVAC configurations to ensure proper clearances and code compliance for generator placement. Photographed electrical panel access points and structural considerations for load calculation and equipment sizing recommendations.
Hinckley, OH 44233
Completed preventive maintenance on a 2-year-old MVP air conditioning system. Inspected control board electronics, verified all wire connections and harnesses were secure, and examined the pleated air filter element which showed normal condition for the system's age.
Completed preventive maintenance on a 2-year-old MVP air conditioning system. Inspected control board electronics, verified all wire connections and harnesses were secure, and examined the pleated air filter element which showed normal condition for the system's age.
Stephanie E.
Stephanie E. Checked in
Completed preventive maintenance on a 2-year-old MVP air conditioning system. Inspected control board electronics, verified all wire connections and harnesses were secure, and examined the pleated air filter element which showed normal condition for the system's age.
Hinckley, OH 44233
Completed installation of 22kW Generac standby generator with 200-amp automatic transfer switch, oil warmer, and surge protection system. Ran 15 feet of gas line to unit and coordinated with gas utility for service connection. Wired transfer switch to main electrical panel, configured all circuits for automatic transfer during power outages, and verified proper operation of all safety systems and electrical connections per manufacturer specifications and local code requirements.
Completed installation of 22kW Generac standby generator with 200-amp automatic transfer switch, oil warmer, and surge protection system. Ran 15 feet of gas line to unit and coordinated with gas utility for service connection. Wired transfer switch to main electrical panel, configured all circuits for automatic transfer during power outages, and verified proper operation of all safety systems and electrical connections per manufacturer specifications and local code requirements.
Generator
Generator Checked in
Completed installation of 22kW Generac standby generator with 200-amp automatic transfer switch, oil warmer, and surge protection system. Ran 15 feet of gas line to unit and coordinated with gas utility for service connection. Wired transfer switch to main electrical panel, configured all circuits for automatic transfer during power outages, and verified proper operation of all safety systems and electrical connections per manufacturer specifications and local code requirements.
Hinckley, OH 44233
Responded to service call for 16-year-old Generac generator with reported low oil pressure issue. Upon arrival, performed comprehensive diagnostic evaluation of the unit including visual inspection, oil level verification, and pressure system assessment. Documented existing conditions with measurements and photographs of the generator installation at the exterior foundation location. Customer was advised that a detailed estimate for necessary repairs would be provided following the diagnostic evaluation.
Responded to service call for 16-year-old Generac generator with reported low oil pressure issue. Upon arrival, performed comprehensive diagnostic evaluation of the unit including visual inspection, oil level verification, and pressure system assessment. Documented existing conditions with measurements and photographs of the generator installation at the exterior foundation location. Customer was advised that a detailed estimate for necessary repairs would be provided following the diagnostic evaluation.
Eric L.
Eric L. Checked in
Responded to service call for 16-year-old Generac generator with reported low oil pressure issue. Upon arrival, performed comprehensive diagnostic evaluation of the unit including visual inspection, oil level verification, and pressure system assessment. Documented existing conditions with measurements and photographs of the generator installation at the exterior foundation location. Customer was advised that a detailed estimate for necessary repairs would be provided following the diagnostic evaluation.
Hinckley, OH 44233
Completed water heater replacement in residential utility room. Removed existing unit and installed new A.O. Smith ProLine tanked water heater with proper plumbing connections, expansion tank, drain pan, and temperature control assembly. All copper and PVC piping configured to code specifications with system tested and operational upon completion.
Completed water heater replacement in residential utility room. Removed existing unit and installed new A.O. Smith ProLine tanked water heater with proper plumbing connections, expansion tank, drain pan, and temperature control assembly. All copper and PVC piping configured to code specifications with system tested and operational upon completion.
Isaiah H.
Isaiah H. Checked in
Completed water heater replacement in residential utility room. Removed existing unit and installed new A.O. Smith ProLine tanked water heater with proper plumbing connections, expansion tank, drain pan, and temperature control assembly. All copper and PVC piping configured to code specifications with system tested and operational upon completion.
Hinckley, OH 44233
Responded to emergency call for outdoor GFCI outlet that experienced arcing and sparking incident. Upon arrival, found existing outlet installation with severely corroded metal electrical box, deteriorated weatherproof housing, and compromised wire connections due to prolonged moisture exposure. Removed damaged GFCI receptacle and corroded junction box from exterior wall. Installed new weather-resistant electrical box with proper sealing, replaced all compromised wiring, and installed new GFCI outlet with appropriate weatherproof-in-use cover rated for outdoor applications. Verified proper ground fault protection functionality through testing of trip mechanism. Additionally installed second outdoor receptacle at separate location on property as requested, ensuring compliance with exterior outlet spacing requirements and proper GFCI protection for outdoor circuits.
Responded to emergency call for outdoor GFCI outlet that experienced arcing and sparking incident. Upon arrival, found existing outlet installation with severely corroded metal electrical box, deteriorated weatherproof housing, and compromised wire connections due to prolonged moisture exposure. Removed damaged GFCI receptacle and corroded junction box from exterior wall. Installed new weather-resistant electrical box with proper sealing, replaced all compromised wiring, and installed new GFCI outlet with appropriate weatherproof-in-use cover rated for outdoor applications. Verified proper ground fault protection functionality through testing of trip mechanism. Additionally installed second outdoor receptacle at separate location on property as requested, ensuring compliance with exterior outlet spacing requirements and proper GFCI protection for outdoor circuits.
Andrew V.
Andrew V. Checked in
Responded to emergency call for outdoor GFCI outlet that experienced arcing and sparking incident. Upon arrival, found existing outlet installation with severely corroded metal electrical box, deteriorated weatherproof housing, and compromised wire connections due to prolonged moisture exposure. Removed damaged GFCI receptacle and corroded junction box from exterior wall. Installed new weather-resistant electrical box with proper sealing, replaced all compromised wiring, and installed new GFCI outlet with appropriate weatherproof-in-use cover rated for outdoor applications. Verified proper ground fault protection functionality through testing of trip mechanism. Additionally installed second outdoor receptacle at separate location on property as requested, ensuring compliance with exterior outlet spacing requirements and proper GFCI protection for outdoor circuits.
Hinckley, OH 44233
Conducted comprehensive HVAC estimate for complete system replacement including heat pump, furnace, and generator installation. Assessed existing mechanical room configuration with vertical ductwork and evaluated electrical panel capacity to determine requirements for new equipment integration and necessary electrical upgrades to support the proposed three-unit system installation.
Conducted comprehensive HVAC estimate for complete system replacement including heat pump, furnace, and generator installation. Assessed existing mechanical room configuration with vertical ductwork and evaluated electrical panel capacity to determine requirements for new equipment integration and necessary electrical upgrades to support the proposed three-unit system installation.
Kevin T.
Kevin T. Checked in
Conducted comprehensive HVAC estimate for complete system replacement including heat pump, furnace, and generator installation. Assessed existing mechanical room configuration with vertical ductwork and evaluated electrical panel capacity to determine requirements for new equipment integration and necessary electrical upgrades to support the proposed three-unit system installation.
Hinckley, OH 44233
Completed comprehensive air conditioning tune-up on residential HVAC system. Inspected evaporator coil and condenser components, noting minor surface oxidation at coil seam but no performance issues. Verified proper operation of furnace unit, condensate pump, and all associated drainage systems.
Completed comprehensive air conditioning tune-up on residential HVAC system. Inspected evaporator coil and condenser components, noting minor surface oxidation at coil seam but no performance issues. Verified proper operation of furnace unit, condensate pump, and all associated drainage systems.
Mario M.
Mario M. Checked in
Completed comprehensive air conditioning tune-up on residential HVAC system. Inspected evaporator coil and condenser components, noting minor surface oxidation at coil seam but no performance issues. Verified proper operation of furnace unit, condensate pump, and all associated drainage systems.
Hinckley, OH 44233
Performed comprehensive maintenance on Kohler residential backup generator system including inspection of all external components, conduit connections, and mounting hardware. Generator found in good operating condition with proper ventilation and secure installation on concrete pad. Investigated reported flickering lights throughout house and weak power issues in shed; inspected main electrical panel, branch circuits, and outdoor wiring runs. Examined exterior lighting circuits and conduit routing along foundation as requested. Verified all generator transfer switch connections and tested automatic startup functionality. Documented equipment condition with photographs showing generator placement, electrical connections, and associated exterior components including meter box and conduit pathways.
Performed comprehensive maintenance on Kohler residential backup generator system including inspection of all external components, conduit connections, and mounting hardware. Generator found in good operating condition with proper ventilation and secure installation on concrete pad. Investigated reported flickering lights throughout house and weak power issues in shed; inspected main electrical panel, branch circuits, and outdoor wiring runs. Examined exterior lighting circuits and conduit routing along foundation as requested. Verified all generator transfer switch connections and tested automatic startup functionality. Documented equipment condition with photographs showing generator placement, electrical connections, and associated exterior components including meter box and conduit pathways.
Austin B.
Austin B. Checked in
Performed comprehensive maintenance on Kohler residential backup generator system including inspection of all external components, conduit connections, and mounting hardware. Generator found in good operating condition with proper ventilation and secure installation on concrete pad. Investigated reported flickering lights throughout house and weak power issues in shed; inspected main electrical panel, branch circuits, and outdoor wiring runs. Examined exterior lighting circuits and conduit routing along foundation as requested. Verified all generator transfer switch connections and tested automatic startup functionality. Documented equipment condition with photographs showing generator placement, electrical connections, and associated exterior components including meter box and conduit pathways.
Hinckley, OH 44233

 

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image