Blind & Sons: Trusted HVAC, Plumbing & Electrical Services in Massillon, OH

A gas furnace installed in a residential basement

Established in 1937, Blind & Sons has been Massillon’s premier source for high-quality HVAC, plumbing, and electrical services. We’re proud to serve homeowners throughout this historic Ohio city with trusted craftsmanship, availability, and no overtime fees. Our licensed and insured technicians bring a legacy of nearly 100 years of experience, along with modern solutions tailored to every home. Whether you need emergency repairs or scheduled maintenance, Blind & Sons delivers peace of mind with every visit.

Call (330) 753-7711 today to schedule fast, dependable service in Massillon, OH or contact us online!

Proudly Serving the City of Massillon

Massillon, OH, isn’t just known for its historic roots and legendary football pride—it’s a city where tradition meets progress. With a blend of early 20th-century homes, revitalized neighborhoods, and new residential developments, each property presents its own unique challenges when it comes to comfort, safety, and efficiency.

At Blind & Sons, we know Massillon inside and out. From homes near Duncan Plaza and the downtown district to those out toward Amherst or Perry Heights, we’ve tailored solutions for every type of structure. Our deep local knowledge and nearly a century of experience allow us to provide custom HVAC, plumbing, and electrical service plans built around your home’s age, architecture, and your family’s everyday needs.

Comprehensive Massillon Plumbing Services 

From clogged drains and leaky faucets to full water heater replacements, Blind & Sons provides expert plumbing solutions backed by decades of experience. We respond quickly, treat your home with respect, and deliver lasting results. Blind & Sons offer Massillon plumbing services that include:

  • Drain Cleaning & Sewer Services: We clear clogs, clean drains, and use video camera inspections to identify blockages or damage deep within your pipes.
  • Water Heater Services: Whether you need a traditional tank or are upgrading to a tankless model, we handle installation, repair, and routine maintenance.
  • Reverse Osmosis Systems: Improve the taste and quality of your water with advanced filtration installed by our experienced plumbers.
  • General Plumbing Repairs: We repair kitchen and bathroom fixtures, leaky pipes, broken shut-off valves, and more.
    • Gas Line Services: Our team installs and repairs residential gas lines to ensure the safe and efficient delivery of natural gas to your appliances and heating systems.
    • Leak Detection: Using advanced diagnostic tools, we locate and resolve hidden water or gas leaks before they lead to costly damage or safety risks.

    Sump Pump Services: Protect your basement from water damage with expert sump pump installation, maintenance, and repair services. We ensure your system activates when needed and operates at peak efficiency to keep your home dry and safe.

Don’t let a minor plumbing issue turn into a major headache—call the Blind & Sons team today.

Need Services?

Massillon Electrical Services Done Right

Electrical work is no place to cut corners. Blind & Sons’ licensed electricians bring top-level expertise to every project, from simple outlet repairs to full panel upgrades. Our Massillon electrical services include:

Our electricians arrive with fully stocked vehicles and solve most issues the same day.

Indoor Air Quality Services for a Healthier Massillon Home

Breathing clean, pollutant-free air indoors is vital for your health—especially for those with asthma or allergies. Our indoor air quality experts assess and improve the air in your home using proven techniques and products.

Ask about our full indoor air quality evaluation for your Massillon home.

Air Conditioning Services for Massillon Summers

Heat pump unit outside a brick building

With temperatures rising in recent years, it’s more important than ever to have an efficient and reliable cooling system. Blind & Sons provides complete AC services for homeowners throughout Massillon.

Through our Maintenance Value Plan, you’ll get exclusive access to priority service, repair discounts, and seasonal tune-ups.

Heating Services for Massillon’s Cold Winters

When the snow piles up in Massillon, you need a heating system that won’t let you down. Blind & Sons is equipped to handle all your heating needs—whether you’re staying warm with a gas furnace or looking to upgrade to a heat pump.

Our team is trained to recommend the best heating options based on your home’s layout and budget.

Need Services?

Why Massillon Homeowners Trust Blind & Sons

With over 85 years of serving the community, Blind & Sons continues to lead the way in quality, responsiveness, and long-term reliability. We’re not just experts—we’re your neighbors.

Benefits of choosing Blind & Sons include:

  • HVAC emergency services with no overtime charges
  • 100% satisfaction guaranteed on all repairs and installations
  • Licensed, background-checked, and extensively trained technicians
  • Straightforward, honest pricing with no surprise fees
  • Exclusive Maintenance Value Plan with tune-ups and discounts

We know the homes of Massillon—from classic two-stories to newer developments—and tailor our service to match the unique needs of every property.

Book Your HVAC, Plumbing & Electrical Service in Massillon Today

Whether you’re upgrading your heating system, troubleshooting a flickering light, or dealing with a leaky faucet, Blind & Sons is the name Massillon families trust for comprehensive and dependable service.

Call (330) 753-7711 or contact us online now to schedule your service appointment in Massillon, OH!

 

Recent Jobs and Reviews in Massillon, OH

Job Locations and Reviews

Installed new AC circuit with proper wiring and conduit routing in attic space. Work included mounting electrical panel with dual-row circuit breaker configuration, running metallic and flexible conduit from panel to equipment location, and completing all necessary connections per code requirements for dedicated air conditioning power supply.
Installed new AC circuit with proper wiring and conduit routing in attic space. Work included mounting electrical panel with dual-row circuit breaker configuration, running metallic and flexible conduit from panel to equipment location, and completing all necessary connections per code requirements for dedicated air conditioning power supply.
Matthew H.
Matthew H. Checked in
Installed new AC circuit with proper wiring and conduit routing in attic space. Work included mounting electrical panel with dual-row circuit breaker configuration, running metallic and flexible conduit from panel to equipment location, and completing all necessary connections per code requirements for dedicated air conditioning power supply.
Massillon, OH 44646
Conducted on-site assessment for whole house generator installation at a 2100 square foot ranch home constructed in 1998. Evaluated electrical service panel capacity, existing utility connections, and potential generator placement locations. Documented current electrical infrastructure including basement wiring configurations and available space for transfer switch installation. Photographed proposed installation areas and existing electrical components to develop comprehensive pricing estimate for complete standby generator system with automatic transfer switch capability.
Conducted on-site assessment for whole house generator installation at a 2100 square foot ranch home constructed in 1998. Evaluated electrical service panel capacity, existing utility connections, and potential generator placement locations. Documented current electrical infrastructure including basement wiring configurations and available space for transfer switch installation. Photographed proposed installation areas and existing electrical components to develop comprehensive pricing estimate for complete standby generator system with automatic transfer switch capability.
Eric L.
Eric L. Checked in
Conducted on-site assessment for whole house generator installation at a 2100 square foot ranch home constructed in 1998. Evaluated electrical service panel capacity, existing utility connections, and potential generator placement locations. Documented current electrical infrastructure including basement wiring configurations and available space for transfer switch installation. Photographed proposed installation areas and existing electrical components to develop comprehensive pricing estimate for complete standby generator system with automatic transfer switch capability.
Massillon, OH 44646
Responded to major water leak originating from furnace coil. Upon arrival, inspected HVAC unit and confirmed active leak from evaporator coil causing water damage to surrounding area. Documented equipment condition and leak source with photos showing affected cabinet panels and drainage components.
Responded to major water leak originating from furnace coil. Upon arrival, inspected HVAC unit and confirmed active leak from evaporator coil causing water damage to surrounding area. Documented equipment condition and leak source with photos showing affected cabinet panels and drainage components.
William S.
William S. Checked in
Responded to major water leak originating from furnace coil. Upon arrival, inspected HVAC unit and confirmed active leak from evaporator coil causing water damage to surrounding area. Documented equipment condition and leak source with photos showing affected cabinet panels and drainage components.
Massillon, OH 44646
Massillon, OH - Responded to no cooling complaint at residential property. Upon arrival, inspected outdoor condenser unit and found system operational with no visible defects or mechanical issues. Unit running normally with proper airflow through coils and fan operation confirmed.
William S.
William S. Checked in
Responded to no cooling complaint at residential property. Upon arrival, inspected outdoor condenser unit and found system operational with no visible defects or mechanical issues. Unit running normally with proper airflow through coils and fan operation confirmed.
Massillon, OH 44646
Massillon, OH - Replaced failed bar sink faucet that had frozen and split the plastic components. Ordered replacement parts, which arrived at shop the following day, and completed installation of new chrome two-handle faucet assembly on stainless steel drop-in sink.
Travis B.
Travis B. Checked in
Replaced failed bar sink faucet that had frozen and split the plastic components. Ordered replacement parts, which arrived at shop the following day, and completed installation of new chrome two-handle faucet assembly on stainless steel drop-in sink.
Massillon, OH 44646
Massillon, OH - Responded to service call for installation of dedicated electrical outlet for newly installed tankless water heater. Assessed existing electrical panel capacity and circuit availability, identified appropriate breaker location, and provided estimate for running dedicated circuit with proper amperage rating to support tankless water heater electrical requirements within requested timeframe.
Steven M.
Steven M. Checked in
Responded to service call for installation of dedicated electrical outlet for newly installed tankless water heater. Assessed existing electrical panel capacity and circuit availability, identified appropriate breaker location, and provided estimate for running dedicated circuit with proper amperage rating to support tankless water heater electrical requirements within requested timeframe.
Massillon, OH 44646
Responded to no-cooling complaint on 12-year-old outdoor air conditioning unit. Upon arrival, found contactor assembly and capacitor heavily covered in cobwebs and debris, indicating lack of recent maintenance. Inspected electrical connections and found aged, worn wiring throughout the unit. Observed 45/5µF dual-run capacitor rated at 370V AC with multiple wire connections. Cleaned contactor assembly and surrounding electrical components, removing extensive spider web accumulation from relay contacts, terminals, and wiring connections. Verified all wire connections were secure at contactor and capacitor terminals. Tested contactor operation and capacitor functionality. System restored to proper cooling operation following cleaning and inspection of electrical components.
Responded to no-cooling complaint on 12-year-old outdoor air conditioning unit. Upon arrival, found contactor assembly and capacitor heavily covered in cobwebs and debris, indicating lack of recent maintenance. Inspected electrical connections and found aged, worn wiring throughout the unit. Observed 45/5µF dual-run capacitor rated at 370V AC with multiple wire connections. Cleaned contactor assembly and surrounding electrical components, removing extensive spider web accumulation from relay contacts, terminals, and wiring connections. Verified all wire connections were secure at contactor and capacitor terminals. Tested contactor operation and capacitor functionality. System restored to proper cooling operation following cleaning and inspection of electrical components.
Daniel S.
Daniel S. Checked in
Responded to no-cooling complaint on 12-year-old outdoor air conditioning unit. Upon arrival, found contactor assembly and capacitor heavily covered in cobwebs and debris, indicating lack of recent maintenance. Inspected electrical connections and found aged, worn wiring throughout the unit. Observed 45/5µF dual-run capacitor rated at 370V AC with multiple wire connections. Cleaned contactor assembly and surrounding electrical components, removing extensive spider web accumulation from relay contacts, terminals, and wiring connections. Verified all wire connections were secure at contactor and capacitor terminals. Tested contactor operation and capacitor functionality. System restored to proper cooling operation following cleaning and inspection of electrical components.
Massillon, OH 44646
Massillon, OH - Completed first-time air conditioning and evaporator coil installation at residential property. Installed new dual-fuse disconnect block with FLNR-rated fuses and established proper electrical connections to outdoor condensing unit, ensuring all wiring met code requirements and manufacturer specifications.
Charles A.
Charles A. Checked in
Completed first-time air conditioning and evaporator coil installation at residential property. Installed new dual-fuse disconnect block with FLNR-rated fuses and established proper electrical connections to outdoor condensing unit, ensuring all wiring met code requirements and manufacturer specifications.
Massillon, OH 44646
Responded to emergency call for mainline backup in basement. Upon inspection, discovered cracked and deteriorating cast iron sewer line causing sewage backup into residential plumbing system. Backup had resulted in water damage to basement ceiling with visible structural deterioration and staining. Documented extensive damage to ceiling materials and evidence of sewage backup affecting bathroom fixtures on upper level, with visible staining in toilet bowl indicating compromised drainage. Assessed mainline crack location and severity to determine repair scope required for proper system restoration.
Responded to emergency call for mainline backup in basement. Upon inspection, discovered cracked and deteriorating cast iron sewer line causing sewage backup into residential plumbing system. Backup had resulted in water damage to basement ceiling with visible structural deterioration and staining. Documented extensive damage to ceiling materials and evidence of sewage backup affecting bathroom fixtures on upper level, with visible staining in toilet bowl indicating compromised drainage. Assessed mainline crack location and severity to determine repair scope required for proper system restoration.
Mark W.
Mark W. Checked in
Responded to emergency call for mainline backup in basement. Upon inspection, discovered cracked and deteriorating cast iron sewer line causing sewage backup into residential plumbing system. Backup had resulted in water damage to basement ceiling with visible structural deterioration and staining. Documented extensive damage to ceiling materials and evidence of sewage backup affecting bathroom fixtures on upper level, with visible staining in toilet bowl indicating compromised drainage. Assessed mainline crack location and severity to determine repair scope required for proper system restoration.
Massillon, OH 44646
Responded to service call for tankless water heater displaying exhaust blockage error and failing to heat water. Upon arrival, performed diagnostic inspection of the unit and exhaust venting system. Inspected internal components, electrical connections, and exhaust pathway to identify the source of the blockage error. Cleared obstruction from exhaust vent termination and verified proper airflow through the venting system. Tested unit operation and confirmed water heater restored to normal heating function with error code cleared.
Responded to service call for tankless water heater displaying exhaust blockage error and failing to heat water. Upon arrival, performed diagnostic inspection of the unit and exhaust venting system. Inspected internal components, electrical connections, and exhaust pathway to identify the source of the blockage error. Cleared obstruction from exhaust vent termination and verified proper airflow through the venting system. Tested unit operation and confirmed water heater restored to normal heating function with error code cleared.
Craig S.
Craig S. Checked in
Responded to service call for tankless water heater displaying exhaust blockage error and failing to heat water. Upon arrival, performed diagnostic inspection of the unit and exhaust venting system. Inspected internal components, electrical connections, and exhaust pathway to identify the source of the blockage error. Cleared obstruction from exhaust vent termination and verified proper airflow through the venting system. Tested unit operation and confirmed water heater restored to normal heating function with error code cleared.
Massillon, OH 44646
Completed MVP recurring cooling maintenance visit. Inspected and documented condition of indoor air filter, which showed significant dust accumulation and discoloration requiring attention. Evaluated outdoor condenser unit, noting dirt buildup on heat exchanger coils and minor paint deterioration on exterior casing. Photographed equipment conditions for maintenance records.
Completed MVP recurring cooling maintenance visit. Inspected and documented condition of indoor air filter, which showed significant dust accumulation and discoloration requiring attention. Evaluated outdoor condenser unit, noting dirt buildup on heat exchanger coils and minor paint deterioration on exterior casing. Photographed equipment conditions for maintenance records.
Taylor F.
Taylor F. Checked in
Completed MVP recurring cooling maintenance visit. Inspected and documented condition of indoor air filter, which showed significant dust accumulation and discoloration requiring attention. Evaluated outdoor condenser unit, noting dirt buildup on heat exchanger coils and minor paint deterioration on exterior casing. Photographed equipment conditions for maintenance records.
Massillon, OH 44646
Responded to service call for outdoor spigot replacement and extension work. Accessed crawl space to assess existing plumbing infrastructure and locate water supply lines serving two outdoor spigots. Navigated through confined area with exposed copper piping, vapor barriers, and brick foundation to evaluate current spigot installations and determine optimal routing for extensions. One outdoor spigot identified as requiring complete replacement with frost-free unit to prevent freeze damage. Documented existing conditions including pipe locations, accessibility constraints, and connection points for planned extensions. Additionally provided on-site evaluation of two existing fireplaces for potential conversion to gas operation, examining firebox construction, existing ventilation, and structural considerations for future gas line installation and burner system integration.
Responded to service call for outdoor spigot replacement and extension work. Accessed crawl space to assess existing plumbing infrastructure and locate water supply lines serving two outdoor spigots. Navigated through confined area with exposed copper piping, vapor barriers, and brick foundation to evaluate current spigot installations and determine optimal routing for extensions. One outdoor spigot identified as requiring complete replacement with frost-free unit to prevent freeze damage. Documented existing conditions including pipe locations, accessibility constraints, and connection points for planned extensions. Additionally provided on-site evaluation of two existing fireplaces for potential conversion to gas operation, examining firebox construction, existing ventilation, and structural considerations for future gas line installation and burner system integration.
Craig S.
Craig S. Checked in
Responded to service call for outdoor spigot replacement and extension work. Accessed crawl space to assess existing plumbing infrastructure and locate water supply lines serving two outdoor spigots. Navigated through confined area with exposed copper piping, vapor barriers, and brick foundation to evaluate current spigot installations and determine optimal routing for extensions. One outdoor spigot identified as requiring complete replacement with frost-free unit to prevent freeze damage. Documented existing conditions including pipe locations, accessibility constraints, and connection points for planned extensions. Additionally provided on-site evaluation of two existing fireplaces for potential conversion to gas operation, examining firebox construction, existing ventilation, and structural considerations for future gas line installation and burner system integration.
Massillon, OH 44647
Completed MVP cooling maintenance visit including system inspection and filter service. Replaced air filter at wall-mounted return vent and verified proper directional installation. Performed temperature measurements at ductwork in attic space, recording reading of 55.8 degrees to confirm system performance and adequate cooling output.
Completed MVP cooling maintenance visit including system inspection and filter service. Replaced air filter at wall-mounted return vent and verified proper directional installation. Performed temperature measurements at ductwork in attic space, recording reading of 55.8 degrees to confirm system performance and adequate cooling output.
Colton D.
Colton D. Checked in
Completed MVP cooling maintenance visit including system inspection and filter service. Replaced air filter at wall-mounted return vent and verified proper directional installation. Performed temperature measurements at ductwork in attic space, recording reading of 55.8 degrees to confirm system performance and adequate cooling output.
Massillon, OH 44646
Massillon, OH - Responded to service call for leaky shower faucet in bathroom with decorative oil-rubbed bronze fixtures. Inspected shower control valve and tub spout assembly mounted on beige ceramic tile surround, identified source of leak, and completed necessary repairs to restore proper function and eliminate water dripping.
James P.
James P. Checked in
Responded to service call for leaky shower faucet in bathroom with decorative oil-rubbed bronze fixtures. Inspected shower control valve and tub spout assembly mounted on beige ceramic tile surround, identified source of leak, and completed necessary repairs to restore proper function and eliminate water dripping.
Massillon, OH 44646
Massillon, OH - Responded to emergency call for water line repair following previous service visit. Upon arrival, discovered active water leak at kitchen sink faucet assembly when water supply was restored. The faucet spout head had become detached from the main fixture body, causing uncontrolled water discharge throughout the area. Shut off water supply to prevent further damage, assessed the dual-handle faucet assembly, and documented the failed component. Repaired the disconnected spout head and restored proper water flow to the fixture, ensuring all connections were secure and leak-free before completing the service call.
Travis B.
Travis B. Checked in
Responded to emergency call for water line repair following previous service visit. Upon arrival, discovered active water leak at kitchen sink faucet assembly when water supply was restored. The faucet spout head had become detached from the main fixture body, causing uncontrolled water discharge throughout the area. Shut off water supply to prevent further damage, assessed the dual-handle faucet assembly, and documented the failed component. Repaired the disconnected spout head and restored proper water flow to the fixture, ensuring all connections were secure and leak-free before completing the service call.
Massillon, OH 44646
Completed warranty repair to address minor leak in drain line connection on previously repaired main sewer line. Sourced and staged necessary replacement parts from multiple suppliers to ensure proper materials were available for repair. Replaced faulty PVC drain fittings and connections, including curved elbow joints and P-trap assembly. Verified proper sealing at all pipe joints and couplings to eliminate leak. Inspected surrounding plumbing infrastructure, including connections between PVC and copper piping with metal couplings. Tested system for proper drainage flow and confirmed no additional leaks present. All repairs completed to code specifications with warranty coverage applied.
Completed warranty repair to address minor leak in drain line connection on previously repaired main sewer line. Sourced and staged necessary replacement parts from multiple suppliers to ensure proper materials were available for repair. Replaced faulty PVC drain fittings and connections, including curved elbow joints and P-trap assembly. Verified proper sealing at all pipe joints and couplings to eliminate leak. Inspected surrounding plumbing infrastructure, including connections between PVC and copper piping with metal couplings. Tested system for proper drainage flow and confirmed no additional leaks present. All repairs completed to code specifications with warranty coverage applied.
Jared K.
Jared K. Checked in
Completed warranty repair to address minor leak in drain line connection on previously repaired main sewer line. Sourced and staged necessary replacement parts from multiple suppliers to ensure proper materials were available for repair. Replaced faulty PVC drain fittings and connections, including curved elbow joints and P-trap assembly. Verified proper sealing at all pipe joints and couplings to eliminate leak. Inspected surrounding plumbing infrastructure, including connections between PVC and copper piping with metal couplings. Tested system for proper drainage flow and confirmed no additional leaks present. All repairs completed to code specifications with warranty coverage applied.
Massillon, OH 44646
Completed MVP cooling maintenance visit on outdoor condensing units. Performed standard preventive maintenance procedures including inspection of both units, verification of proper operation, and assessment of surrounding conditions. Noted vegetation growth around equipment that may require future attention to maintain adequate airflow and accessibility for service.
Completed MVP cooling maintenance visit on outdoor condensing units. Performed standard preventive maintenance procedures including inspection of both units, verification of proper operation, and assessment of surrounding conditions. Noted vegetation growth around equipment that may require future attention to maintain adequate airflow and accessibility for service.
Matthew F.
Matthew F. Checked in
Completed MVP cooling maintenance visit on outdoor condensing units. Performed standard preventive maintenance procedures including inspection of both units, verification of proper operation, and assessment of surrounding conditions. Noted vegetation growth around equipment that may require future attention to maintain adequate airflow and accessibility for service.
Massillon, OH 44646
Completed scheduled preventive maintenance visit on 12-year-old residential air conditioning system. Performed comprehensive system inspection including electrical component examination, capacitor condition assessment, and temperature diagnostics. Verified proper operation of outdoor condensing unit, checked all electrical connections and wiring integrity, and confirmed system cooling performance with digital temperature measurements at supply registers reading 73°F. All components found to be functioning within normal operating parameters with no immediate repairs required.
Completed scheduled preventive maintenance visit on 12-year-old residential air conditioning system. Performed comprehensive system inspection including electrical component examination, capacitor condition assessment, and temperature diagnostics. Verified proper operation of outdoor condensing unit, checked all electrical connections and wiring integrity, and confirmed system cooling performance with digital temperature measurements at supply registers reading 73°F. All components found to be functioning within normal operating parameters with no immediate repairs required.
Taylor F.
Taylor F. Checked in
Completed scheduled preventive maintenance visit on 12-year-old residential air conditioning system. Performed comprehensive system inspection including electrical component examination, capacitor condition assessment, and temperature diagnostics. Verified proper operation of outdoor condensing unit, checked all electrical connections and wiring integrity, and confirmed system cooling performance with digital temperature measurements at supply registers reading 73°F. All components found to be functioning within normal operating parameters with no immediate repairs required.
Massillon, OH 44646
Installed two exterior GFCI-protected outlets with underground wiring runs. Excavated and trenched approximately 15 feet from the main residence and 10 feet from the detached shop building, routing direct burial cable through conduit to each new outlet location. Added dedicated circuit breakers to the electrical panel and completed all connections per NEC standards for outdoor receptacles.
Installed two exterior GFCI-protected outlets with underground wiring runs. Excavated and trenched approximately 15 feet from the main residence and 10 feet from the detached shop building, routing direct burial cable through conduit to each new outlet location. Added dedicated circuit breakers to the electrical panel and completed all connections per NEC standards for outdoor receptacles.
Matthew H.
Matthew H. Checked in
Installed two exterior GFCI-protected outlets with underground wiring runs. Excavated and trenched approximately 15 feet from the main residence and 10 feet from the detached shop building, routing direct burial cable through conduit to each new outlet location. Added dedicated circuit breakers to the electrical panel and completed all connections per NEC standards for outdoor receptacles.
Massillon, OH 44646
Completed kitchen faucet replacement, removing existing fixture and installing new Delta model matte black pull-down faucet with spring-style design and flexible spray head. Disconnected water supply lines, removed old faucet assembly and mounting hardware from granite countertop with double-basin undermount sink. Installed new faucet deck plate, secured mounting hardware, connected hot and cold water supply lines, and attached flexible hose assembly. Tested water flow and spray functions, checked all connections for leaks, and verified proper operation of pull-down mechanism and spray head settings.
Completed kitchen faucet replacement, removing existing fixture and installing new Delta model matte black pull-down faucet with spring-style design and flexible spray head. Disconnected water supply lines, removed old faucet assembly and mounting hardware from granite countertop with double-basin undermount sink. Installed new faucet deck plate, secured mounting hardware, connected hot and cold water supply lines, and attached flexible hose assembly. Tested water flow and spray functions, checked all connections for leaks, and verified proper operation of pull-down mechanism and spray head settings.
Nick L.
Nick L. Checked in
Completed kitchen faucet replacement, removing existing fixture and installing new Delta model matte black pull-down faucet with spring-style design and flexible spray head. Disconnected water supply lines, removed old faucet assembly and mounting hardware from granite countertop with double-basin undermount sink. Installed new faucet deck plate, secured mounting hardware, connected hot and cold water supply lines, and attached flexible hose assembly. Tested water flow and spray functions, checked all connections for leaks, and verified proper operation of pull-down mechanism and spray head settings.
Massillon, OH 44646

 

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image