Schedule Service

Air Conditioning, Heating, Electrical & Plumbing Services in Tallmadge, OH

Close-up on an electrician fixing an electrical outlet and measuring the voltage at a house

If your home’s plumbing or HVAC systems aren’t maintained by qualified professionals, they can quickly lose efficiency and reliability. Blind & Sons is here to make sure everything runs smoothly. Since 1937, we’ve proudly served Tallmadge homeowners with expert heating, cooling, plumbing, and electrical services—keeping homes comfortable and safe for over 85 years.

Schedule HVAC, plumbing, or electrical service in Tallmadge, OH, by calling Blind & Sons at (330) 753-7711 or contact us online today!.

Discover Life in Tallmadge, OH

Located in Summit County, just minutes from Akron, Tallmadge, OH, is a community that blends historic charm with modern living. Known for its iconic Tallmadge Circle and welcoming neighborhoods, this city offers a peaceful suburban atmosphere while still providing easy access to shopping, dining, and outdoor recreation. Tallmadge is home to a vibrant community with top-rated schools, beautiful parks like Tallmadge Meadows, and strong family values that make it a desirable place to live.

Homes in Tallmadge range from historic properties with character to new builds with modern efficiency. Regardless of the style or age of your home, having dependable HVAC, plumbing, and electrical systems is essential. Blind & Sons is proud to serve the Tallmadge community with home comfort solutions that are both reliable and tailored to the unique needs of local homeowners.

Heating Services for Comfort You Can Count On

Older heating systems often struggle to keep up with demand and can become costly to maintain. Whether your furnace is acting up or your boiler has seen better days, our expert technicians are trained to diagnose and repair all types of heating systems.

We offer:

If a replacement makes more financial sense than a repair, we’ll walk you through affordable options that fit your space and your budget.

Need Services?

Efficient Cooling Solutions in Tallmadge

AC systems typically last 10 to 15 years with proper care. But if your home is cooling unevenly, your system is making strange noises, or your air doesn’t feel as cool as it used to, it’s time to call Blind & Sons.

Our NATE-certified technicians in Tallmadge offer:

We handle everything from removing your old unit to walking you through how to use your new thermostat, so you’re never left guessing.

Indoor Air Quality Services for a Healthier Home

Air quality in your home has a huge impact on your health. According to the Consumer Product Safety Commission, up to 30% of newer or recently remodeled homes suffer from poor indoor air quality.

Our indoor air quality services help reduce allergens and contaminants, including:

Breathe easier with help from the Tallmadge air quality experts at Blind & Sons.

Tallmadge Electrical Services You Can Rely On

Red Electric Vehicle being charged by an EV Charging Station

Don’t take chances with DIY electrical work. Faulty wiring is one of the leading causes of residential fires, and it’s not worth the risk. Our certified electricians provide safe, code-compliant services for homes of all ages.

We offer:

Need a quick repair or a full system upgrade? Blind & Sons will handle it with safety and precision.

Need Services?

Expert Plumbing Services in Tallmadge, OH

Your home’s plumbing system is more complex than it may appear—and it doesn’t take much for older pipes to cause big problems. Whether you’re dealing with clogged drains, a broken water heater, or a sewer line issue, Blind & Sons is ready to help.

Our plumbing services include:

We use modern equipment to pinpoint problems quickly and fix them the right way—saving you time and money in the long run.

Why Choose Blind & Sons in Tallmadge?

At Blind & Sons, we’ve spent over eight decades building a reputation for quality, trust, and expert service. Our Trust Certified professionals undergo regular training, background checks, and follow a strict code of conduct to ensure your home is in the best hands.

  • 100% Satisfaction Guarantee: We stand behind our work with a commitment to getting it right.
  • No Overtime Charges—Ever: You’ll never pay extra for after-hours service.
  • Flexible Financing Options: Make your home upgrades more affordable.
  • Maintenance Value Plan: Enjoy savings, priority scheduling, and ongoing system care.

Contact Blind & Sons Today!

From our family to yours, we’re committed to delivering service that goes above and beyond. Call Blind & Sons at (330) 753-7711 today or contact us online to schedule HVAC, plumbing, or electrical services in Tallmadge, OH.

 

Recent Jobs and Reviews in Tallmadge, OH

Job Locations and Reviews

Responded to service call for malfunctioning handheld shower head with water leaking from multiple points at the wall connection and hose attachment to spray handle. Removed defective unit and installed new chrome-finished handheld shower head assembly with flexible metal hose and adjustable wall-mounted bracket. Tested installation to verify proper water flow and confirmed no leaks at connection points.
Responded to service call for malfunctioning handheld shower head with water leaking from multiple points at the wall connection and hose attachment to spray handle. Removed defective unit and installed new chrome-finished handheld shower head assembly with flexible metal hose and adjustable wall-mounted bracket. Tested installation to verify proper water flow and confirmed no leaks at connection points.
David K.
David K. Checked in
Responded to service call for malfunctioning handheld shower head with water leaking from multiple points at the wall connection and hose attachment to spray handle. Removed defective unit and installed new chrome-finished handheld shower head assembly with flexible metal hose and adjustable wall-mounted bracket. Tested installation to verify proper water flow and confirmed no leaks at connection points.
Tallmadge, OH 44278
Completed BS-MVP cooling maintenance visit on residential HVAC system. Inspected and verified air filtration system with clean accordion-style filters properly installed in housing unit. Performed diagnostic temperature measurements on system components, recording supply air temperature of 45°F which indicates proper cooling operation and refrigerant charge levels within acceptable parameters.
Completed BS-MVP cooling maintenance visit on residential HVAC system. Inspected and verified air filtration system with clean accordion-style filters properly installed in housing unit. Performed diagnostic temperature measurements on system components, recording supply air temperature of 45°F which indicates proper cooling operation and refrigerant charge levels within acceptable parameters.
Colton D.
Colton D. Checked in
Completed BS-MVP cooling maintenance visit on residential HVAC system. Inspected and verified air filtration system with clean accordion-style filters properly installed in housing unit. Performed diagnostic temperature measurements on system components, recording supply air temperature of 45°F which indicates proper cooling operation and refrigerant charge levels within acceptable parameters.
Tallmadge, OH 44278
Responded to service call for outdoor spigot inspection involving four separate concerns. Upon arrival, accessed crawl space and basement areas to evaluate plumbing infrastructure serving exterior hose bibs. Inspected brass shut-off valves with cross-handle controls mounted to wooden platform in crawl space, verifying proper operation and checking for leaks or corrosion. Examined ABS DWV vent piping and associated copper supply lines running through floor joists to ensure no interference with outdoor spigot functionality. Assessed valve mounting security and insulation condition around supply lines to prevent freeze damage. Documented existing plumbing configuration with photographs showing valve locations, pipe routing, and structural support systems. All four areas of concern were evaluated and findings communicated to customer via phone contact.
Responded to service call for outdoor spigot inspection involving four separate concerns. Upon arrival, accessed crawl space and basement areas to evaluate plumbing infrastructure serving exterior hose bibs. Inspected brass shut-off valves with cross-handle controls mounted to wooden platform in crawl space, verifying proper operation and checking for leaks or corrosion. Examined ABS DWV vent piping and associated copper supply lines running through floor joists to ensure no interference with outdoor spigot functionality. Assessed valve mounting security and insulation condition around supply lines to prevent freeze damage. Documented existing plumbing configuration with photographs showing valve locations, pipe routing, and structural support systems. All four areas of concern were evaluated and findings communicated to customer via phone contact.
Isaiah H.
Isaiah H. Checked in
Responded to service call for outdoor spigot inspection involving four separate concerns. Upon arrival, accessed crawl space and basement areas to evaluate plumbing infrastructure serving exterior hose bibs. Inspected brass shut-off valves with cross-handle controls mounted to wooden platform in crawl space, verifying proper operation and checking for leaks or corrosion. Examined ABS DWV vent piping and associated copper supply lines running through floor joists to ensure no interference with outdoor spigot functionality. Assessed valve mounting security and insulation condition around supply lines to prevent freeze damage. Documented existing plumbing configuration with photographs showing valve locations, pipe routing, and structural support systems. All four areas of concern were evaluated and findings communicated to customer via phone contact.
Tallmadge, OH 44278
Completed annual air conditioning maintenance on outdoor condensing unit. Performed comprehensive system inspection including electrical connections, capacitor condition, and compressor operation. Measured and verified electrical current draw using clamp meter, confirming proper amperage within manufacturer specifications. Cleaned and inspected contactor, capacitor, and wiring connections in electrical compartment. All components found to be operating normally with no immediate service needs identified. System tested and left in proper working condition.
Completed annual air conditioning maintenance on outdoor condensing unit. Performed comprehensive system inspection including electrical connections, capacitor condition, and compressor operation. Measured and verified electrical current draw using clamp meter, confirming proper amperage within manufacturer specifications. Cleaned and inspected contactor, capacitor, and wiring connections in electrical compartment. All components found to be operating normally with no immediate service needs identified. System tested and left in proper working condition.
Jesus M.
Jesus M. Checked in
Completed annual air conditioning maintenance on outdoor condensing unit. Performed comprehensive system inspection including electrical connections, capacitor condition, and compressor operation. Measured and verified electrical current draw using clamp meter, confirming proper amperage within manufacturer specifications. Cleaned and inspected contactor, capacitor, and wiring connections in electrical compartment. All components found to be operating normally with no immediate service needs identified. System tested and left in proper working condition.
Tallmadge, OH 44278
Tallmadge, OH - Responded to customer request for replacement pricing on 16-year-old tanked water heater. Performed on-site assessment and documented existing Fury EverKleen model unit installed in basement utility area. Inspected current installation including supply lines, shut-off valves, temperature/pressure relief valve, and drain valve. Unit appeared in clean condition with no visible leaks or corrosion at time of inspection. Photographed equipment and provided replacement estimate to customer.
James P.
James P. Checked in
Responded to customer request for replacement pricing on 16-year-old tanked water heater. Performed on-site assessment and documented existing Fury EverKleen model unit installed in basement utility area. Inspected current installation including supply lines, shut-off valves, temperature/pressure relief valve, and drain valve. Unit appeared in clean condition with no visible leaks or corrosion at time of inspection. Photographed equipment and provided replacement estimate to customer.
Tallmadge, OH 44278
Completed MVP cooling maintenance visit on residential air conditioning system. Performed comprehensive inspection of outdoor condenser unit, verified proper operation of fan assembly, and documented equipment condition with photos showing unit in good operational status with intact housing and components.
Completed MVP cooling maintenance visit on residential air conditioning system. Performed comprehensive inspection of outdoor condenser unit, verified proper operation of fan assembly, and documented equipment condition with photos showing unit in good operational status with intact housing and components.
Kevin D.
Kevin D. Checked in
Completed MVP cooling maintenance visit on residential air conditioning system. Performed comprehensive inspection of outdoor condenser unit, verified proper operation of fan assembly, and documented equipment condition with photos showing unit in good operational status with intact housing and components.
Tallmadge, OH 44278
Conducted estimate for replacement of existing gas boiler system showing significant age and deterioration, including heavily rusted components and weathered ductwork connections. Assessment confirmed boiler replacement needed in current location without relocation, with existing copper piping infrastructure and gas lines to remain in place for connection to new unit.
Conducted estimate for replacement of existing gas boiler system showing significant age and deterioration, including heavily rusted components and weathered ductwork connections. Assessment confirmed boiler replacement needed in current location without relocation, with existing copper piping infrastructure and gas lines to remain in place for connection to new unit.
Kevin T.
Kevin T. Checked in
Conducted estimate for replacement of existing gas boiler system showing significant age and deterioration, including heavily rusted components and weathered ductwork connections. Assessment confirmed boiler replacement needed in current location without relocation, with existing copper piping infrastructure and gas lines to remain in place for connection to new unit.
Tallmadge, OH 44278
Completed comprehensive air conditioning tune-up on residential outdoor condenser unit. Performed standard preventive maintenance procedures including inspection of electrical components, verified proper fuse operation, checked refrigerant lines for leaks and proper insulation, cleaned condenser coils, and tested system performance. All components found to be in good working condition with no immediate repairs required.
Completed comprehensive air conditioning tune-up on residential outdoor condenser unit. Performed standard preventive maintenance procedures including inspection of electrical components, verified proper fuse operation, checked refrigerant lines for leaks and proper insulation, cleaned condenser coils, and tested system performance. All components found to be in good working condition with no immediate repairs required.
Hershel M.
Hershel M. Checked in
Completed comprehensive air conditioning tune-up on residential outdoor condenser unit. Performed standard preventive maintenance procedures including inspection of electrical components, verified proper fuse operation, checked refrigerant lines for leaks and proper insulation, cleaned condenser coils, and tested system performance. All components found to be in good working condition with no immediate repairs required.
Tallmadge, OH 44278
Completed scheduled cooling maintenance visit for MVP customer. Performed standard system inspection and preventive maintenance procedures on air conditioning equipment. Unit operational and functioning properly upon completion of service. Exterior disconnect and condenser area inspected with no immediate concerns noted.
Completed scheduled cooling maintenance visit for MVP customer. Performed standard system inspection and preventive maintenance procedures on air conditioning equipment. Unit operational and functioning properly upon completion of service. Exterior disconnect and condenser area inspected with no immediate concerns noted.
Jibreel H.
Jibreel H. Checked in
Completed scheduled cooling maintenance visit for MVP customer. Performed standard system inspection and preventive maintenance procedures on air conditioning equipment. Unit operational and functioning properly upon completion of service. Exterior disconnect and condenser area inspected with no immediate concerns noted.
Tallmadge, OH 44278
Completed scheduled BS-MVP cooling maintenance visit on a 3-year-old Bryant residential HVAC system. Performed comprehensive inspection of furnace unit, verified proper operation of condensate drainage system including PVC trap configuration and condensate pump, and inspected all associated ductwork and electrical connections. All components found operating within normal parameters with no issues identified.
Completed scheduled BS-MVP cooling maintenance visit on a 3-year-old Bryant residential HVAC system. Performed comprehensive inspection of furnace unit, verified proper operation of condensate drainage system including PVC trap configuration and condensate pump, and inspected all associated ductwork and electrical connections. All components found operating within normal parameters with no issues identified.
Daniel S.
Daniel S. Checked in
Completed scheduled BS-MVP cooling maintenance visit on a 3-year-old Bryant residential HVAC system. Performed comprehensive inspection of furnace unit, verified proper operation of condensate drainage system including PVC trap configuration and condensate pump, and inspected all associated ductwork and electrical connections. All components found operating within normal parameters with no issues identified.
Tallmadge, OH 44278
Installed a 2.1 gallon expansion tank on a 50-gallon water heater system with 3/4" connection. Parts were ordered and staged with the water heater kit prior to installation, then properly integrated into the existing plumbing system to provide thermal expansion protection and maintain system pressure stability.
Installed a 2.1 gallon expansion tank on a 50-gallon water heater system with 3/4" connection. Parts were ordered and staged with the water heater kit prior to installation, then properly integrated into the existing plumbing system to provide thermal expansion protection and maintain system pressure stability.
Mark W.
Mark W. Checked in
Installed a 2.1 gallon expansion tank on a 50-gallon water heater system with 3/4" connection. Parts were ordered and staged with the water heater kit prior to installation, then properly integrated into the existing plumbing system to provide thermal expansion protection and maintain system pressure stability.
Tallmadge, OH 44278
Completed preventive maintenance service on 15-year-old air conditioning system for MVP customer. Performed comprehensive inspection of air handler unit, including examination of evaporator coils, refrigerant lines, capacitor, and control board. Verified proper operation of all electrical components, connections, and system controls to ensure optimal cooling performance.
Completed preventive maintenance service on 15-year-old air conditioning system for MVP customer. Performed comprehensive inspection of air handler unit, including examination of evaporator coils, refrigerant lines, capacitor, and control board. Verified proper operation of all electrical components, connections, and system controls to ensure optimal cooling performance.
Stephanie E.
Stephanie E. Checked in
Completed preventive maintenance service on 15-year-old air conditioning system for MVP customer. Performed comprehensive inspection of air handler unit, including examination of evaporator coils, refrigerant lines, capacitor, and control board. Verified proper operation of all electrical components, connections, and system controls to ensure optimal cooling performance.
Tallmadge, OH 44278
Completed MVP cooling maintenance visit on residential HVAC system. Performed temperature diagnostics using digital thermometer, recording supply air temperature of 58.8°F at register and measuring temperatures at air handler/ductwork to verify proper system operation and adequate cooling performance.
Completed MVP cooling maintenance visit on residential HVAC system. Performed temperature diagnostics using digital thermometer, recording supply air temperature of 58.8°F at register and measuring temperatures at air handler/ductwork to verify proper system operation and adequate cooling performance.
Colton D.
Colton D. Checked in
Completed MVP cooling maintenance visit on residential HVAC system. Performed temperature diagnostics using digital thermometer, recording supply air temperature of 58.8°F at register and measuring temperatures at air handler/ductwork to verify proper system operation and adequate cooling performance.
Tallmadge, OH 44278
Performed routine maintenance inspection on 8-year-old air conditioning system for MVP customer. Evaluated system components including heat exchanger and recorded ambient temperature reading of 53°F in attic space. Documented equipment condition through photographic records showing HVAC unit with secured banding and temperature measurements on weathered decking, confirming system operational status.
Performed routine maintenance inspection on 8-year-old air conditioning system for MVP customer. Evaluated system components including heat exchanger and recorded ambient temperature reading of 53°F in attic space. Documented equipment condition through photographic records showing HVAC unit with secured banding and temperature measurements on weathered decking, confirming system operational status.
Kevin D.
Kevin D. Checked in
Performed routine maintenance inspection on 8-year-old air conditioning system for MVP customer. Evaluated system components including heat exchanger and recorded ambient temperature reading of 53°F in attic space. Documented equipment condition through photographic records showing HVAC unit with secured banding and temperature measurements on weathered decking, confirming system operational status.
Tallmadge, OH 44278
Tallmadge, OH - Responded to service call for leaking 4-year-old natural gas tanked water heater. Upon inspection, identified active leak at water heater requiring evaluation of unit and connected plumbing system including copper supply lines, PVC venting, expansion tank, and associated valves and fittings.
James P.
James P. Checked in
Responded to service call for leaking 4-year-old natural gas tanked water heater. Upon inspection, identified active leak at water heater requiring evaluation of unit and connected plumbing system including copper supply lines, PVC venting, expansion tank, and associated valves and fittings.
Tallmadge, OH 44278
Tallmadge, OH - Performed annual descaling maintenance on tankless water heater in residential basement utility area. Flushed unit with descaling solution to remove mineral buildup and maintain optimal efficiency. Customer reported no operational issues or concerns prior to service; unit tested and confirmed functioning properly upon completion of routine maintenance.
Craig S.
Craig S. Checked in
Performed annual descaling maintenance on tankless water heater in residential basement utility area. Flushed unit with descaling solution to remove mineral buildup and maintain optimal efficiency. Customer reported no operational issues or concerns prior to service; unit tested and confirmed functioning properly upon completion of routine maintenance.
Tallmadge, OH 44278
Completed routine MVP cooling maintenance on 8-year-old system. During inspection, discovered blown fuses in outdoor unit's electrical circuit. Removed and inspected failed fuses, confirmed electrical fault condition using digital multimeter to test voltage and continuity at disconnect and control board terminals. Replaced defective fuses with proper amperage-rated components, verified all electrical connections were secure, and tested system operation to ensure proper cooling function restored.
Completed routine MVP cooling maintenance on 8-year-old system. During inspection, discovered blown fuses in outdoor unit's electrical circuit. Removed and inspected failed fuses, confirmed electrical fault condition using digital multimeter to test voltage and continuity at disconnect and control board terminals. Replaced defective fuses with proper amperage-rated components, verified all electrical connections were secure, and tested system operation to ensure proper cooling function restored.
Jesus M.
Jesus M. Checked in
Completed routine MVP cooling maintenance on 8-year-old system. During inspection, discovered blown fuses in outdoor unit's electrical circuit. Removed and inspected failed fuses, confirmed electrical fault condition using digital multimeter to test voltage and continuity at disconnect and control board terminals. Replaced defective fuses with proper amperage-rated components, verified all electrical connections were secure, and tested system operation to ensure proper cooling function restored.
Tallmadge, OH 44278
Tallmadge, OH - Provided estimate for clearing a localized clog in the master bathroom lavatory sink's left drain. Additionally assessed first floor hall bathroom shower valve with dripping at shower head and recommended replacement of cartridge with new Moen 1222 Positemp cartridge, with parts ordered and available for pickup at Famous Akron supply house under specified purchase order.
Karl M.
Karl M. Checked in
Provided estimate for clearing a localized clog in the master bathroom lavatory sink's left drain. Additionally assessed first floor hall bathroom shower valve with dripping at shower head and recommended replacement of cartridge with new Moen 1222 Positemp cartridge, with parts ordered and available for pickup at Famous Akron supply house under specified purchase order.
Tallmadge, OH 44278
Responded to a residential plumbing call for a clogged bathroom sink and dripping shower in a 10-year-old home. Successfully cleared the sink drain obstruction, restoring proper water flow and drainage. Inspected and addressed the shower fixture leak to eliminate the dripping issue.
Responded to a residential plumbing call for a clogged bathroom sink and dripping shower in a 10-year-old home. Successfully cleared the sink drain obstruction, restoring proper water flow and drainage. Inspected and addressed the shower fixture leak to eliminate the dripping issue.
Karl M.
Karl M. Checked in
Responded to a residential plumbing call for a clogged bathroom sink and dripping shower in a 10-year-old home. Successfully cleared the sink drain obstruction, restoring proper water flow and drainage. Inspected and addressed the shower fixture leak to eliminate the dripping issue.
Tallmadge, OH 44278
Responded to emergency service call for overheated and damaged electrical panel in 1957-built residence. Upon inspection, found obsolete main breaker assembly with significant heat damage, discoloration, and deteriorated internal components. Removed failed main breaker mechanism and assessed overall panel condition, which showed signs of age-related wear, dust accumulation, and outdated wiring configuration. Documented existing electrical service entrance cables and circuit distribution system. Recommended complete panel replacement due to safety concerns with vintage equipment and heat-compromised components in the 69-year-old installation.
Responded to emergency service call for overheated and damaged electrical panel in 1957-built residence. Upon inspection, found obsolete main breaker assembly with significant heat damage, discoloration, and deteriorated internal components. Removed failed main breaker mechanism and assessed overall panel condition, which showed signs of age-related wear, dust accumulation, and outdated wiring configuration. Documented existing electrical service entrance cables and circuit distribution system. Recommended complete panel replacement due to safety concerns with vintage equipment and heat-compromised components in the 69-year-old installation.
Eric L.
Eric L. Checked in
Responded to emergency service call for overheated and damaged electrical panel in 1957-built residence. Upon inspection, found obsolete main breaker assembly with significant heat damage, discoloration, and deteriorated internal components. Removed failed main breaker mechanism and assessed overall panel condition, which showed signs of age-related wear, dust accumulation, and outdated wiring configuration. Documented existing electrical service entrance cables and circuit distribution system. Recommended complete panel replacement due to safety concerns with vintage equipment and heat-compromised components in the 69-year-old installation.
Tallmadge, OH 44278

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image