Schedule Service

Heating, AC, Plumbing & Electric in Bedford, OH

Garbage disposal under a sink

Since 1937, Blind & Sons has proudly served Bedford, OH, and the surrounding communities with expert home services. From repairing leaky pipes and installing new air conditioners to upgrading electrical panels, our team is equipped to handle it all. With over 80 years of industry experience, we bring professionalism, transparency, and reliable workmanship to every job.

If your home systems aren’t working like they should—or you’re planning an upgrade—call Blind & Sons at (330) 753-7711 or contact us online to schedule a service visit in Bedford today.

Discover Life in Bedford, OH

Located in Cuyahoga County, Bedford is a historic and welcoming community known for its charming town square, tree-lined streets, and access to outdoor recreation. With close proximity to Cleveland and a small-town feel, Bedford offers residents the best of both worlds. The city is home to beautiful green spaces like Bedford Reservation, historic landmarks, and an active downtown that reflects its strong sense of community and pride.

Bedford homeowners take pride in maintaining their homes, and Blind & Sons is honored to play a part in that mission. Whether you live in a classic colonial or a contemporary build, you can trust us to keep your essential systems running efficiently and safely year-round.

Need Services?

Trusted Plumbing Services in Bedford

When a plumbing problem strikes, it can disrupt your entire day. Blind & Sons provides reliable and responsive plumbing services in Bedford designed to restore order and comfort to your home quickly. Our licensed plumbers arrive fully equipped to diagnose and resolve any issue—from a minor leak to a full system replacement.

  • Water Heater Services: Hot water is a necessity, not a luxury. Whether you have a traditional tank or a tankless system, we handle repairs, replacements, and routine maintenance to ensure you’re never left in the cold.
  • Drain Cleaning: Stubborn clogs and slow drains can lead to more serious problems if ignored. We use advanced drain cleaning tools to remove blockages and restore proper flow.
  • Leak Detection & Pipe Repairs: Undetected leaks can lead to high water bills and property damage. Our team uses precise techniques to locate and fix leaks fast.
  • Sump Pump Installation & Maintenance: Protect your basement from water intrusion and flooding with dependable sump pump services tailored to the Ohio climate.
  • Sewer Line Services: We offer camera inspections and trenchless sewer solutions to identify and repair issues without tearing up your yard.

From small issues to major upgrades, Blind & Sons is the plumbing company Bedford homeowners count on.

Professional Electrical Services in Bedford, OH

Electricity powers nearly every function of modern life, and when electrical issues arise, safety is a top concern. At Blind & Sons, we provide expert electrical services in Bedford to keep your home running smoothly and securely.

Whether you’re renovating or simply need a repair, you can rely on Blind & Sons for electrical services that meet the highest standards of safety and efficiency.

Bedford Heating and Cooling Services for Year-Round Comfort

Home gas water heater in bathroom for hot water

With Bedford’s changing seasons, having a dependable heating and cooling system isn’t just a luxury—it’s essential. At Blind & Sons, our comprehensive HVAC services help you stay comfortable no matter the temperature outside. From emergency repairs to energy-saving upgrades, we’ve got you covered.

Our HVAC services include:

Our NATE-certified technicians prioritize your comfort, energy savings, and long-term system performance with every visit.

Need Services?

Why Bedford Homeowners Choose Blind & Sons

Choosing the right home services provider means trusting someone with your comfort, safety, and investment. Blind & Sons has earned the trust of Bedford residents with over eight decades of consistent, high-quality service. We’re not just another contractor—we’re your neighbors.

Here’s why Bedford families rely on us:

  • Over 80 Years of Trusted Experience
  • Locally Operated
  • Trust Certified Technicians (Background Checked & Drug Tested)
  • Upfront Pricing and Transparent Quotes
  • No Overtime Charges—Ever
  • 100% Satisfaction Guarantee
  • Maintenance Value Plan (MVP) with Exclusive Perks

We take the time to listen to your concerns, explain your options clearly, and ensure the job is done right the first time. From leaky faucets to full system replacements, we bring the same commitment to excellence.

Schedule Home Services in Bedford, OH Today

Your home deserves the best—and so do you. Blind & Sons is proud to provide heating, cooling, plumbing, and electrical services you can count on in Bedford, OH. With flexible scheduling, friendly professionals, and unmatched service quality, we’re ready to help make your home more comfortable and efficient today.

Call Blind & Sons at (330) 753-7711 or contact us online to schedule your next home service appointment in Bedford!

 

Recent Jobs and Reviews in Bedford, OH

Bedford, OH at a glance

Blind and Sons has completed 20 jobs in Bedford, OH between July 2026 and October 2026.

The most recent job was on October 2, 2026.

Blind and Sons has completed 71 jobs in Bedford, OH in the last 12 months.

Job Locations and Reviews

Completed installation of 80% AFUE gas furnace in residential mechanical room. Unit installed with proper metallic ductwork connections, gas line hookup, and venting system. Installed new Kidde carbon monoxide alarm as required safety measure for combustion appliance installation. All equipment positioned and secured per manufacturer specifications and local code requirements.
Completed installation of 80% AFUE gas furnace in residential mechanical room. Unit installed with proper metallic ductwork connections, gas line hookup, and venting system. Installed new Kidde carbon monoxide alarm as required safety measure for combustion appliance installation. All equipment positioned and secured per manufacturer specifications and local code requirements.
Chris H.
Chris H. Checked in
Completed installation of 80% AFUE gas furnace in residential mechanical room. Unit installed with proper metallic ductwork connections, gas line hookup, and venting system. Installed new Kidde carbon monoxide alarm as required safety measure for combustion appliance installation. All equipment positioned and secured per manufacturer specifications and local code requirements.
Bedford, OH 44146
Responded to no-heat call on 15-year-old gas furnace with reported humming noise upon startup. Upon inspection, found extensive dirt and debris accumulation throughout the unit's interior components, including control module, blower compartment, and ductwork connections. The heavy buildup of dust and grime on electrical components and surrounding surfaces indicated prolonged operation without proper maintenance, which was contributing to operational issues. Assessed system condition, documented equipment state with photographs showing significant contamination on control boards and mechanical housing, and provided recommendations for thorough cleaning and maintenance to restore proper function and prevent future failures.
Responded to no-heat call on 15-year-old gas furnace with reported humming noise upon startup. Upon inspection, found extensive dirt and debris accumulation throughout the unit's interior components, including control module, blower compartment, and ductwork connections. The heavy buildup of dust and grime on electrical components and surrounding surfaces indicated prolonged operation without proper maintenance, which was contributing to operational issues. Assessed system condition, documented equipment state with photographs showing significant contamination on control boards and mechanical housing, and provided recommendations for thorough cleaning and maintenance to restore proper function and prevent future failures.
Chris G.
Chris G. Checked in
Responded to no-heat call on 15-year-old gas furnace with reported humming noise upon startup. Upon inspection, found extensive dirt and debris accumulation throughout the unit's interior components, including control module, blower compartment, and ductwork connections. The heavy buildup of dust and grime on electrical components and surrounding surfaces indicated prolonged operation without proper maintenance, which was contributing to operational issues. Assessed system condition, documented equipment state with photographs showing significant contamination on control boards and mechanical housing, and provided recommendations for thorough cleaning and maintenance to restore proper function and prevent future failures.
Bedford, OH 44146
Responded to service call for air conditioning system with reported refrigerant leak. Performed comprehensive diagnostic evaluation of existing Trane furnace and dual outdoor condenser units installed on brick paver pad adjacent to residence. Assessment revealed active refrigerant leak in AC system requiring repair, humidifier component needing replacement, and potential furnace issues warranting further evaluation. Provided detailed estimate for complete HVAC system replacement including new furnace, air conditioning equipment, and associated components to address multiple system deficiencies and ensure reliable climate control operation.
Responded to service call for air conditioning system with reported refrigerant leak. Performed comprehensive diagnostic evaluation of existing Trane furnace and dual outdoor condenser units installed on brick paver pad adjacent to residence. Assessment revealed active refrigerant leak in AC system requiring repair, humidifier component needing replacement, and potential furnace issues warranting further evaluation. Provided detailed estimate for complete HVAC system replacement including new furnace, air conditioning equipment, and associated components to address multiple system deficiencies and ensure reliable climate control operation.
Kevin T.
Kevin T. Checked in
Responded to service call for air conditioning system with reported refrigerant leak. Performed comprehensive diagnostic evaluation of existing Trane furnace and dual outdoor condenser units installed on brick paver pad adjacent to residence. Assessment revealed active refrigerant leak in AC system requiring repair, humidifier component needing replacement, and potential furnace issues warranting further evaluation. Provided detailed estimate for complete HVAC system replacement including new furnace, air conditioning equipment, and associated components to address multiple system deficiencies and ensure reliable climate control operation.
Bedford, OH 44146
Responded to service call for non-functioning water heater that required electrical verification following previous unsuccessful repair attempt. Inspected electrical panel, junction box, and associated wiring in utility room to diagnose power supply issues affecting water heater operation. Verified electrical connections and circuit integrity to mechanical equipment, documented existing conditions with photos showing panel configuration and utility room electrical infrastructure.
Responded to service call for non-functioning water heater that required electrical verification following previous unsuccessful repair attempt. Inspected electrical panel, junction box, and associated wiring in utility room to diagnose power supply issues affecting water heater operation. Verified electrical connections and circuit integrity to mechanical equipment, documented existing conditions with photos showing panel configuration and utility room electrical infrastructure.
Matthew H.
Matthew H. Checked in
Responded to service call for non-functioning water heater that required electrical verification following previous unsuccessful repair attempt. Inspected electrical panel, junction box, and associated wiring in utility room to diagnose power supply issues affecting water heater operation. Verified electrical connections and circuit integrity to mechanical equipment, documented existing conditions with photos showing panel configuration and utility room electrical infrastructure.
Bedford, OH 44146
Responded to service call addressing multiple plumbing concerns including a stuck hose fitting on exterior spigot, frequently clogging floor drain, and non-functioning water heater. Inspected outdoor spigot mounted on foundation where hose end was seized to the connection point. Assessed electrical panel and water heater system to diagnose heating failure. Documented site conditions with photographic evidence showing exterior spigot location on brick and vinyl siding foundation area, as well as electrical panel configuration for water heater troubleshooting purposes.
Responded to service call addressing multiple plumbing concerns including a stuck hose fitting on exterior spigot, frequently clogging floor drain, and non-functioning water heater. Inspected outdoor spigot mounted on foundation where hose end was seized to the connection point. Assessed electrical panel and water heater system to diagnose heating failure. Documented site conditions with photographic evidence showing exterior spigot location on brick and vinyl siding foundation area, as well as electrical panel configuration for water heater troubleshooting purposes.
Denny J.
Denny J. Checked in
Responded to service call addressing multiple plumbing concerns including a stuck hose fitting on exterior spigot, frequently clogging floor drain, and non-functioning water heater. Inspected outdoor spigot mounted on foundation where hose end was seized to the connection point. Assessed electrical panel and water heater system to diagnose heating failure. Documented site conditions with photographic evidence showing exterior spigot location on brick and vinyl siding foundation area, as well as electrical panel configuration for water heater troubleshooting purposes.
bedford, OH 44146
Responded to no cooling complaint on 21-year-old air conditioning system. Upon arrival, performed diagnostic testing using digital multimeter to measure electrical values and system performance. Also inspected 23-year-old furnace and humidifier as requested, as these components had not been serviced recently and customer was concerned about their operational status.
Responded to no cooling complaint on 21-year-old air conditioning system. Upon arrival, performed diagnostic testing using digital multimeter to measure electrical values and system performance. Also inspected 23-year-old furnace and humidifier as requested, as these components had not been serviced recently and customer was concerned about their operational status.
Chris G.
Chris G. Checked in
Responded to no cooling complaint on 21-year-old air conditioning system. Upon arrival, performed diagnostic testing using digital multimeter to measure electrical values and system performance. Also inspected 23-year-old furnace and humidifier as requested, as these components had not been serviced recently and customer was concerned about their operational status.
bedford, OH 44146
Replaced existing garage floodlight fixture with customer-provided dual-head LED motion sensor security light on exterior metal building. Removed old fixture, installed new mounting hardware, connected electrical wiring to the dual-head unit with central motion detector, and verified proper operation of both LED light heads and motion sensing functionality.
Replaced existing garage floodlight fixture with customer-provided dual-head LED motion sensor security light on exterior metal building. Removed old fixture, installed new mounting hardware, connected electrical wiring to the dual-head unit with central motion detector, and verified proper operation of both LED light heads and motion sensing functionality.
Matthew H.
Matthew H. Checked in
Replaced existing garage floodlight fixture with customer-provided dual-head LED motion sensor security light on exterior metal building. Removed old fixture, installed new mounting hardware, connected electrical wiring to the dual-head unit with central motion detector, and verified proper operation of both LED light heads and motion sensing functionality.
Bedford, OH 44146
Completed MVP air conditioning maintenance service. Inspected and tested electrical components including time-delay fuses rated at 250V in outdoor disconnect, verified proper amperage ratings and fuse integrity. Performed electrical diagnostics using clamp meter to measure current draw on system wiring, confirmed normal operating parameters within manufacturer specifications. All electrical connections, wiring, and safety components found in satisfactory working condition.
Completed MVP air conditioning maintenance service. Inspected and tested electrical components including time-delay fuses rated at 250V in outdoor disconnect, verified proper amperage ratings and fuse integrity. Performed electrical diagnostics using clamp meter to measure current draw on system wiring, confirmed normal operating parameters within manufacturer specifications. All electrical connections, wiring, and safety components found in satisfactory working condition.
Colton D.
Colton D. Checked in
Completed MVP air conditioning maintenance service. Inspected and tested electrical components including time-delay fuses rated at 250V in outdoor disconnect, verified proper amperage ratings and fuse integrity. Performed electrical diagnostics using clamp meter to measure current draw on system wiring, confirmed normal operating parameters within manufacturer specifications. All electrical connections, wiring, and safety components found in satisfactory working condition.
Bedford, OH 44146
Responded to no-cooling complaint on newly installed Lennox system. Upon arrival, confirmed outdoor condensing unit fan motor was not operating. Diagnosed failed capacitor preventing compressor and condenser fan operation. Replaced defective dual-run capacitor with OEM replacement part, restoring proper system function. Verified correct amperage draw on both compressor and fan motor, confirmed adequate refrigerant charge, and tested system through complete cooling cycle. Unit now operating within manufacturer specifications with proper airflow and temperature differential across evaporator coil.
Responded to no-cooling complaint on newly installed Lennox system. Upon arrival, confirmed outdoor condensing unit fan motor was not operating. Diagnosed failed capacitor preventing compressor and condenser fan operation. Replaced defective dual-run capacitor with OEM replacement part, restoring proper system function. Verified correct amperage draw on both compressor and fan motor, confirmed adequate refrigerant charge, and tested system through complete cooling cycle. Unit now operating within manufacturer specifications with proper airflow and temperature differential across evaporator coil.
Kevin D.
Kevin D. Checked in
Responded to no-cooling complaint on newly installed Lennox system. Upon arrival, confirmed outdoor condensing unit fan motor was not operating. Diagnosed failed capacitor preventing compressor and condenser fan operation. Replaced defective dual-run capacitor with OEM replacement part, restoring proper system function. Verified correct amperage draw on both compressor and fan motor, confirmed adequate refrigerant charge, and tested system through complete cooling cycle. Unit now operating within manufacturer specifications with proper airflow and temperature differential across evaporator coil.
Bedford, OH 44146
# HVAC Install - Complete System

## Summary
Completed full HVAC system installation including 90% efficiency furnace with humidifier and matching air conditioning unit, verified proper venting installation to ensure flues are not cellular core construction.

## Work Performed

Installed complete residential heating and cooling system in basement mechanical room and exterior location. System consists of Trane brand furnace unit with integrated humidifier and corresponding outdoor condensing unit.

**Indoor Equipment Installation:**
- Mounted gray metal furnace unit on concrete basement floor
- Connected white PVC intake and exhaust venting from furnace, routing upward through structure
- Verified all flue pipes are appropriate non-cellular core material per code requirements
- Installed electrical connections with proper wiring run along installation perimeter
- Connected silver metallic supply ductwork to furnace plenum
- Positioned tall air handler unit adjacent to furnace with prope
# HVAC Install - Complete System

## Summary
Completed full HVAC system installation including 90% efficiency furnace with humidifier and matching air conditioning unit, verified proper venting installation to ensure flues are not cellular core construction.

## Work Performed

Installed complete residential heating and cooling system in basement mechanical room and exterior location. System consists of Trane brand furnace unit with integrated humidifier and corresponding outdoor condensing unit.

**Indoor Equipment Installation:**
- Mounted gray metal furnace unit on concrete basement floor
- Connected white PVC intake and exhaust venting from furnace, routing upward through structure
- Verified all flue pipes are appropriate non-cellular core material per code requirements
- Installed electrical connections with proper wiring run along installation perimeter
- Connected silver metallic supply ductwork to furnace plenum
- Positioned tall air handler unit adjacent to furnace with prope
Jay E.
Jay E. Checked in
# HVAC Install - Complete System ## Summary Completed full HVAC system installation including 90% efficiency furnace with humidifier and matching air conditioning unit, verified proper venting installation to ensure flues are not cellular core construction. ## Work Performed Installed complete residential heating and cooling system in basement mechanical room and exterior location. System consists of Trane brand furnace unit with integrated humidifier and corresponding outdoor condensing unit. **Indoor Equipment Installation:** - Mounted gray metal furnace unit on concrete basement floor - Connected white PVC intake and exhaust venting from furnace, routing upward through structure - Verified all flue pipes are appropriate non-cellular core material per code requirements - Installed electrical connections with proper wiring run along installation perimeter - Connected silver metallic supply ductwork to furnace plenum - Positioned tall air handler unit adjacent to furnace with prope
Bedford, OH 44146
Completed MVP Cooling Visit on a 2-year-old Lennox EL17XC1-030-230A02 system containing HFC-410A refrigerant with a factory charge of 6 lbs 8 oz. Performed comprehensive maintenance inspection of both indoor and outdoor units. Verified electrical specifications are within acceptable parameters (208/230V nominal, MIN 197, MAX 253). Inspected outdoor condenser unit positioned on concrete pad, noting environmental debris accumulation and vegetation growth in surrounding area. Evaluated wall-mounted electrical disconnect box and associated conduit connections for proper operation. Documented equipment specifications including compressor ratings and fan motor specifications (0.7 FLA, 1/8 HP). Recommended installation of surge protector on motherboard to safeguard against electrical surges from home power supply or furnace-generated fluctuations. System operational and performing to manufacturer specifications upon completion of maintenance visit.
Completed MVP Cooling Visit on a 2-year-old Lennox EL17XC1-030-230A02 system containing HFC-410A refrigerant with a factory charge of 6 lbs 8 oz. Performed comprehensive maintenance inspection of both indoor and outdoor units. Verified electrical specifications are within acceptable parameters (208/230V nominal, MIN 197, MAX 253). Inspected outdoor condenser unit positioned on concrete pad, noting environmental debris accumulation and vegetation growth in surrounding area. Evaluated wall-mounted electrical disconnect box and associated conduit connections for proper operation. Documented equipment specifications including compressor ratings and fan motor specifications (0.7 FLA, 1/8 HP). Recommended installation of surge protector on motherboard to safeguard against electrical surges from home power supply or furnace-generated fluctuations. System operational and performing to manufacturer specifications upon completion of maintenance visit.
Mario M.
Mario M. Checked in
Completed MVP Cooling Visit on a 2-year-old Lennox EL17XC1-030-230A02 system containing HFC-410A refrigerant with a factory charge of 6 lbs 8 oz. Performed comprehensive maintenance inspection of both indoor and outdoor units. Verified electrical specifications are within acceptable parameters (208/230V nominal, MIN 197, MAX 253). Inspected outdoor condenser unit positioned on concrete pad, noting environmental debris accumulation and vegetation growth in surrounding area. Evaluated wall-mounted electrical disconnect box and associated conduit connections for proper operation. Documented equipment specifications including compressor ratings and fan motor specifications (0.7 FLA, 1/8 HP). Recommended installation of surge protector on motherboard to safeguard against electrical surges from home power supply or furnace-generated fluctuations. System operational and performing to manufacturer specifications upon completion of maintenance visit.
Bedford, OH 44146
Bedford, OH - Responded to service call for multiple electrical issues including blown circuit requiring split, non-functioning kitchen outlet, and garage motion detector with suspected improper wiring. Inspected electrical panel, identified tripped breaker, and assessed circuit loading to determine need for circuit split to accommodate two customer-supplied light fixtures requiring installation. Troubleshot and corrected motion detector wiring in garage and restored power to inoperative kitchen outlet.
Matthew H.
Matthew H. Checked in
Responded to service call for multiple electrical issues including blown circuit requiring split, non-functioning kitchen outlet, and garage motion detector with suspected improper wiring. Inspected electrical panel, identified tripped breaker, and assessed circuit loading to determine need for circuit split to accommodate two customer-supplied light fixtures requiring installation. Troubleshot and corrected motion detector wiring in garage and restored power to inoperative kitchen outlet.
Bedford, OH 44146
Conducted comprehensive HVAC system evaluation for equipment replacement estimate. Assessed existing gas furnace/air handler unit located in basement utility area, including connected ductwork distribution system, copper refrigerant lines, and electrical connections. Evaluated outdoor condensing unit positioned on concrete pad adjacent to building foundation, inspecting refrigerant line sets, electrical conduit routing, and overall system configuration. Documented current equipment specifications, installation conditions, and provided replacement recommendations based on system age and performance requirements.
Conducted comprehensive HVAC system evaluation for equipment replacement estimate. Assessed existing gas furnace/air handler unit located in basement utility area, including connected ductwork distribution system, copper refrigerant lines, and electrical connections. Evaluated outdoor condensing unit positioned on concrete pad adjacent to building foundation, inspecting refrigerant line sets, electrical conduit routing, and overall system configuration. Documented current equipment specifications, installation conditions, and provided replacement recommendations based on system age and performance requirements.
Kevin T.
Kevin T. Checked in
Conducted comprehensive HVAC system evaluation for equipment replacement estimate. Assessed existing gas furnace/air handler unit located in basement utility area, including connected ductwork distribution system, copper refrigerant lines, and electrical connections. Evaluated outdoor condensing unit positioned on concrete pad adjacent to building foundation, inspecting refrigerant line sets, electrical conduit routing, and overall system configuration. Documented current equipment specifications, installation conditions, and provided replacement recommendations based on system age and performance requirements.
Bedford, OH 44146
Bedford, OH - Installed GFCI outlet in upstairs bathroom per customer request, replacing standard receptacle to provide ground fault protection in wet location as required by electrical code. Coordinated arrival time with customer's wife due to homeowner being unavailable during service call.
Landon M.
Landon M. Checked in
Installed GFCI outlet in upstairs bathroom per customer request, replacing standard receptacle to provide ground fault protection in wet location as required by electrical code. Coordinated arrival time with customer's wife due to homeowner being unavailable during service call.
Bedford, OH 44146
Responded to service call regarding electrical concerns following recent roof work. Performed comprehensive inspection of exterior electrical panel and associated systems. Panel inspection revealed proper circuit breaker configuration with no immediate safety hazards observed. Verified all branch circuit connections, main breaker functionality, and panel integrity. Examined exterior conduit penetrations and junction points near roofline to ensure no damage occurred during roofing operations. All electrical connections found secure with no loose wiring or compromised conductors. Documented panel conditions and surrounding utility infrastructure with photographic evidence for record.
Responded to service call regarding electrical concerns following recent roof work. Performed comprehensive inspection of exterior electrical panel and associated systems. Panel inspection revealed proper circuit breaker configuration with no immediate safety hazards observed. Verified all branch circuit connections, main breaker functionality, and panel integrity. Examined exterior conduit penetrations and junction points near roofline to ensure no damage occurred during roofing operations. All electrical connections found secure with no loose wiring or compromised conductors. Documented panel conditions and surrounding utility infrastructure with photographic evidence for record.
Landon M.
Landon M. Checked in
Responded to service call regarding electrical concerns following recent roof work. Performed comprehensive inspection of exterior electrical panel and associated systems. Panel inspection revealed proper circuit breaker configuration with no immediate safety hazards observed. Verified all branch circuit connections, main breaker functionality, and panel integrity. Examined exterior conduit penetrations and junction points near roofline to ensure no damage occurred during roofing operations. All electrical connections found secure with no loose wiring or compromised conductors. Documented panel conditions and surrounding utility infrastructure with photographic evidence for record.
Bedford, OH 44146
Completed MVP recurring cooling maintenance visit on 4-year-old Lennox HVAC system. Inspected furnace unit, ductwork, refrigerant lines, electrical components including capacitor and contactor, and verified proper system operation. Documented equipment condition with photos showing normal wear and minor debris accumulation in outdoor unit; all components functioning within normal parameters.
Completed MVP recurring cooling maintenance visit on 4-year-old Lennox HVAC system. Inspected furnace unit, ductwork, refrigerant lines, electrical components including capacitor and contactor, and verified proper system operation. Documented equipment condition with photos showing normal wear and minor debris accumulation in outdoor unit; all components functioning within normal parameters.
Mario M.
Mario M. Checked in
Completed MVP recurring cooling maintenance visit on 4-year-old Lennox HVAC system. Inspected furnace unit, ductwork, refrigerant lines, electrical components including capacitor and contactor, and verified proper system operation. Documented equipment condition with photos showing normal wear and minor debris accumulation in outdoor unit; all components functioning within normal parameters.
Bedford, OH 44146
# HVAC Service Report

## Summary
Responded to no-cool complaint on 3-year-old AC system. Diagnosed failed contactor with severe contamination and burn damage, replaced contactor and damaged line set section, restored system to normal cooling operation.

## Work Performed

Upon arrival, found AC system completely non-operational with no power to outdoor condensing unit. Visual inspection revealed contactor assembly heavily contaminated with dust, dirt, and carbon deposits indicating electrical arcing and overheating. Terminal connections showed significant discoloration and tarnishing, with evidence of sustained arcing damage to contact surfaces.

Performed electrical testing and confirmed contactor failure as primary cause of system shutdown. Contacts were welded together from excessive current draw, preventing proper cycling. Brass terminal screws exhibited heat damage and oxidation consistent with poor electrical connection over time.

During outdoor unit inspection, discovered refr
# HVAC Service Report

## Summary
Responded to no-cool complaint on 3-year-old AC system. Diagnosed failed contactor with severe contamination and burn damage, replaced contactor and damaged line set section, restored system to normal cooling operation.

## Work Performed

Upon arrival, found AC system completely non-operational with no power to outdoor condensing unit. Visual inspection revealed contactor assembly heavily contaminated with dust, dirt, and carbon deposits indicating electrical arcing and overheating. Terminal connections showed significant discoloration and tarnishing, with evidence of sustained arcing damage to contact surfaces.

Performed electrical testing and confirmed contactor failure as primary cause of system shutdown. Contacts were welded together from excessive current draw, preventing proper cycling. Brass terminal screws exhibited heat damage and oxidation consistent with poor electrical connection over time.

During outdoor unit inspection, discovered refr
Chris G.
Chris G. Checked in
# HVAC Service Report ## Summary Responded to no-cool complaint on 3-year-old AC system. Diagnosed failed contactor with severe contamination and burn damage, replaced contactor and damaged line set section, restored system to normal cooling operation. ## Work Performed Upon arrival, found AC system completely non-operational with no power to outdoor condensing unit. Visual inspection revealed contactor assembly heavily contaminated with dust, dirt, and carbon deposits indicating electrical arcing and overheating. Terminal connections showed significant discoloration and tarnishing, with evidence of sustained arcing damage to contact surfaces. Performed electrical testing and confirmed contactor failure as primary cause of system shutdown. Contacts were welded together from excessive current draw, preventing proper cycling. Brass terminal screws exhibited heat damage and oxidation consistent with poor electrical connection over time. During outdoor unit inspection, discovered refr
Bedford, OH 44146
Completed installation of 80% efficiency furnace and air conditioning system in attic location. Installed new furnace unit with proper venting and exhaust piping, connected gas lines with appropriate securing, and integrated air handler with metallic supply ductwork. Installed outdoor condensing unit with proper electrical connections including 25-amp fused disconnect, ran refrigerant lines between indoor and outdoor equipment, and verified all electrical wiring and safety controls are functioning correctly per manufacturer specifications.
Completed installation of 80% efficiency furnace and air conditioning system in attic location. Installed new furnace unit with proper venting and exhaust piping, connected gas lines with appropriate securing, and integrated air handler with metallic supply ductwork. Installed outdoor condensing unit with proper electrical connections including 25-amp fused disconnect, ran refrigerant lines between indoor and outdoor equipment, and verified all electrical wiring and safety controls are functioning correctly per manufacturer specifications.
Trent B.
Trent B. Checked in
Completed installation of 80% efficiency furnace and air conditioning system in attic location. Installed new furnace unit with proper venting and exhaust piping, connected gas lines with appropriate securing, and integrated air handler with metallic supply ductwork. Installed outdoor condensing unit with proper electrical connections including 25-amp fused disconnect, ran refrigerant lines between indoor and outdoor equipment, and verified all electrical wiring and safety controls are functioning correctly per manufacturer specifications.
Bedford, OH 44146
Performed comprehensive cooling system tune-up and preventative maintenance on properly functioning HVAC unit. Conducted electrical diagnostics using digital multimeter, measuring system amperage at 8.68A and verifying voltage readings to ensure equipment operating within manufacturer specifications. All components inspected and found to be functioning correctly with no issues identified.
Performed comprehensive cooling system tune-up and preventative maintenance on properly functioning HVAC unit. Conducted electrical diagnostics using digital multimeter, measuring system amperage at 8.68A and verifying voltage readings to ensure equipment operating within manufacturer specifications. All components inspected and found to be functioning correctly with no issues identified.
Chris G.
Chris G. Checked in
Performed comprehensive cooling system tune-up and preventative maintenance on properly functioning HVAC unit. Conducted electrical diagnostics using digital multimeter, measuring system amperage at 8.68A and verifying voltage readings to ensure equipment operating within manufacturer specifications. All components inspected and found to be functioning correctly with no issues identified.
Bedford, OH 44146
Responded to hail damage assessment request for outdoor mini-split condenser unit. Conducted thorough visual inspection of equipment, documenting extensive rust staining on fan guard and top rim, along with weathered concrete pad showing algae growth. Performed electrical diagnostics using digital multimeter to verify system functionality and assess potential component damage from hail impact. Documented unit condition with photographs and provided customer with detailed repair quote based on findings.
Responded to hail damage assessment request for outdoor mini-split condenser unit. Conducted thorough visual inspection of equipment, documenting extensive rust staining on fan guard and top rim, along with weathered concrete pad showing algae growth. Performed electrical diagnostics using digital multimeter to verify system functionality and assess potential component damage from hail impact. Documented unit condition with photographs and provided customer with detailed repair quote based on findings.
Mario M.
Mario M. Checked in
Responded to hail damage assessment request for outdoor mini-split condenser unit. Conducted thorough visual inspection of equipment, documenting extensive rust staining on fan guard and top rim, along with weathered concrete pad showing algae growth. Performed electrical diagnostics using digital multimeter to verify system functionality and assess potential component damage from hail impact. Documented unit condition with photographs and provided customer with detailed repair quote based on findings.
Bedford, OH 44146

 

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image