HVAC, Electrical & Plumbing Services in Kent, OH – Trusted by Homeowners Since 1937

Smart Home Installation

In Kent, OH, where the seasons can swing from icy winters to sweltering summers, it’s essential to have a home that keeps up. That’s why homeowners turn to Blind & Sons—a trusted name in HVAC, plumbing, and electrical services for more than 85 years. We’re proud to offer complete solutions to keep your Kent home running safely, efficiently, and comfortably all year long.

From emergency furnace repairs to whole-home generator installs, we handle it all with professionalism and pride. We’ve built our reputation by putting Kent families first, and it shows in every service call we make.

Call (330) 753-7711 or schedule a visit online to book expert home services in Kent.

Proudly Serving Kent, OH

Situated along the scenic Cuyahoga River, Kent, OH offers a unique blend of historic charm and a laid-back, community-focused atmosphere. It’s known for Kent State University, its vibrant downtown filled with local cafés and shops, and the strong sense of community that runs through every neighborhood. From the scenic walking trails and Kent Bog to weekly events like the Haymaker Farmers’ Market, Kent offers residents a unique mix of natural beauty and lively culture.

Homes here range from charming older properties with character to more modern builds, each with its own needs. At Blind & Sons, we understand the local nuances that come with living in Kent. We’ve worked in homes all over town and know how to adapt our services to match the specific requirements of your property—whether that means working with older plumbing systems or helping you install an energy-efficient HVAC upgrade. Our commitment to Kent goes beyond service calls—we’re proud to be part of the community and to help our neighbors keep their homes running comfortably year-round.

Need Services?

Kent Heating Services That Deliver Lasting Comfort

When winter arrives in Northeast Ohio, your heating system becomes the heart of your home. Blind & Sons provides top-quality heating services to ensure you stay warm no matter how cold it gets outside. Our expert technicians are trained to work on all types of heating systems and will never recommend a replacement unless it’s truly necessary.

We offer:

We prioritize fast service, thorough diagnostics, and repairs that last—because your comfort and safety are our top priorities.

Air Conditioning Services in Kent

Summers in Kent can bring high humidity and long stretches of heat, and when your air conditioning system starts to struggle, it can quickly turn your home into an uncomfortable space. At Blind & Sons, we provide dependable air conditioning services designed to help Kent homeowners stay cool, relaxed, and worry-free throughout the warmest months of the year.

Our Kent cooling services include:

We take the time to properly assess your home’s cooling needs and recommend systems that deliver efficient performance for years to come. Whether you’re upgrading an older system or troubleshooting strange noises, we’ll get the job done right.

Improve the Air You Breathe with Indoor Air Quality Services in Kent

If you’ve noticed more sneezing, coughing, or stale smells in your home, poor indoor air quality could be the cause. Our indoor air quality solutions are designed to make your home not just comfortable—but healthy too.

We offer:

Indoor air pollution is a growing concern, especially in tightly sealed homes. Let our team evaluate your home and create a custom plan to clean up your air.

Professional Electrical Services in Kent

When electrical issues strike, they’re more than just annoying—they can be dangerous. That’s why Blind & Sons takes a safety-first approach to all our electrical services in Kent. Whether you’re upgrading a fuse box or adding an EV charger, our licensed electricians have you covered.

Our electrical services in Kent include:

No matter how big or small the job, we approach every project with care, precision, and a commitment to safety and compliance.

Reliable Plumbing Services in Kent When You Need Them Most

Gas burner

Plumbing problems can go from small annoyances to major emergencies in no time. Our experienced plumbers are here to resolve issues quickly and thoroughly—saving you time, money, and stress. From leaky pipes to major upgrades, we offer the full range of plumbing services Kent homeowners need.

Services include:

Our technicians arrive on time, treat your home with care, and make sure the work is done right the first time.

Need Services?

Why Kent Homeowners Trust Blind & Sons

At Blind & Sons, we don’t believe in cutting corners or offering one-size-fits-all solutions. Every home is different, and every homeowner deserves personal attention. That’s what has helped us serve the Kent community for over eight decades.

Here’s what you can expect when you work with us:

  • Over 85 years of trusted service in Northeast Ohio
  • emergency support when you need it most
  • Honest, upfront pricing with no surprise fees
  • Fully licensed, background-checked technicians
  • Clean, respectful service and attention to detail
  • Online scheduling and repair discounts
  • 100% satisfaction guarantee on all services

We treat your home as if it were our own—and we won’t rest until you’re completely satisfied.

Schedule HVAC, Electrical & Plumbing Services in Kent, OH

No matter what your home needs, Blind & Sons is here to help. From a dripping faucet to a full HVAC overhaul, you can count on us for expert service that puts your comfort and safety first.

Call (330) 753-7711 or book your service online today and discover why Blind & Sons is Kent’s trusted name in home comfort.

Blind & Sons—Keeping Kent homes comfortable, safe, and running smoothly since 1937.

 

Recent Jobs and Reviews in Kent, OH

Job Locations and Reviews

Performed comprehensive air conditioner tune-up on outdoor condensing unit. Conducted electrical diagnostics using digital multimeter to verify proper voltage and amperage readings, with measurements indicating system operating within normal parameters at approximately 50.5 volts during testing. Inspected condenser unit exterior condition, noting accumulated debris and weathering on mesh grill covering that required attention for optimal airflow and system efficiency.
Performed comprehensive air conditioner tune-up on outdoor condensing unit. Conducted electrical diagnostics using digital multimeter to verify proper voltage and amperage readings, with measurements indicating system operating within normal parameters at approximately 50.5 volts during testing. Inspected condenser unit exterior condition, noting accumulated debris and weathering on mesh grill covering that required attention for optimal airflow and system efficiency.
Jesus M.
Jesus M. Checked in
Performed comprehensive air conditioner tune-up on outdoor condensing unit. Conducted electrical diagnostics using digital multimeter to verify proper voltage and amperage readings, with measurements indicating system operating within normal parameters at approximately 50.5 volts during testing. Inspected condenser unit exterior condition, noting accumulated debris and weathering on mesh grill covering that required attention for optimal airflow and system efficiency.
Kent, OH 44240
Responded to washing machine drainage issue causing water backup into adjacent shower stall in 1955-era home. Upon arrival, assessed the plumbing configuration and determined the washing machine discharge line was improperly draining into the shared drain system, creating hydraulic pressure that forced water through the shower drain during wash cycles. Inspected the drain line routing and confirmed inadequate venting or partial blockage in the common waste line serving both fixtures. Cleared the drainage pathway to restore proper flow and eliminate the backup condition. Verified successful operation by running test cycles and confirming no further water discharge into the shower area.
Responded to washing machine drainage issue causing water backup into adjacent shower stall in 1955-era home. Upon arrival, assessed the plumbing configuration and determined the washing machine discharge line was improperly draining into the shared drain system, creating hydraulic pressure that forced water through the shower drain during wash cycles. Inspected the drain line routing and confirmed inadequate venting or partial blockage in the common waste line serving both fixtures. Cleared the drainage pathway to restore proper flow and eliminate the backup condition. Verified successful operation by running test cycles and confirming no further water discharge into the shower area.
Mark W.
Mark W. Checked in
Responded to washing machine drainage issue causing water backup into adjacent shower stall in 1955-era home. Upon arrival, assessed the plumbing configuration and determined the washing machine discharge line was improperly draining into the shared drain system, creating hydraulic pressure that forced water through the shower drain during wash cycles. Inspected the drain line routing and confirmed inadequate venting or partial blockage in the common waste line serving both fixtures. Cleared the drainage pathway to restore proper flow and eliminate the backup condition. Verified successful operation by running test cycles and confirming no further water discharge into the shower area.
Kent, OH 44240
Completed MVP cooling maintenance visit on outdoor condensing unit. Performed visual inspection of equipment exterior, verified unit positioning on concrete pad with rock landscaping, and documented current condition of coil surfaces and fan assembly. Unit operational with minor dirt accumulation noted on filter panel requiring standard cleaning during next service interval.
Completed MVP cooling maintenance visit on outdoor condensing unit. Performed visual inspection of equipment exterior, verified unit positioning on concrete pad with rock landscaping, and documented current condition of coil surfaces and fan assembly. Unit operational with minor dirt accumulation noted on filter panel requiring standard cleaning during next service interval.
Jesus M.
Jesus M. Checked in
Completed MVP cooling maintenance visit on outdoor condensing unit. Performed visual inspection of equipment exterior, verified unit positioning on concrete pad with rock landscaping, and documented current condition of coil surfaces and fan assembly. Unit operational with minor dirt accumulation noted on filter panel requiring standard cleaning during next service interval.
Kent, OH 44240
Conducted on-site assessment for HVAC system replacement, documenting existing electrical infrastructure including main breaker panel configuration and exterior electrical disconnect box. Photographed current equipment locations and electrical connections to prepare comprehensive replacement estimate for new air conditioning system installation.
Conducted on-site assessment for HVAC system replacement, documenting existing electrical infrastructure including main breaker panel configuration and exterior electrical disconnect box. Photographed current equipment locations and electrical connections to prepare comprehensive replacement estimate for new air conditioning system installation.
Jordan K.
Jordan K. Checked in
Conducted on-site assessment for HVAC system replacement, documenting existing electrical infrastructure including main breaker panel configuration and exterior electrical disconnect box. Photographed current equipment locations and electrical connections to prepare comprehensive replacement estimate for new air conditioning system installation.
Kent, OH 44240
Completed scheduled MVP cooling maintenance visit on residential HVAC system. Performed comprehensive inspection of Lennox furnace and cooling components, including examination of electrical connections, capacitor condition, refrigerant lines, condensate drain system, and ductwork. All system components found operating within normal parameters with no deficiencies noted.
Completed scheduled MVP cooling maintenance visit on residential HVAC system. Performed comprehensive inspection of Lennox furnace and cooling components, including examination of electrical connections, capacitor condition, refrigerant lines, condensate drain system, and ductwork. All system components found operating within normal parameters with no deficiencies noted.
Kevin D.
Kevin D. Checked in
Completed scheduled MVP cooling maintenance visit on residential HVAC system. Performed comprehensive inspection of Lennox furnace and cooling components, including examination of electrical connections, capacitor condition, refrigerant lines, condensate drain system, and ductwork. All system components found operating within normal parameters with no deficiencies noted.
Kent, OH 44240
Completed scheduled cooling maintenance visit on 7-year-old air conditioning system. Performed comprehensive inspection of air handler unit, including examination of evaporator coil and heat exchanger assembly. Verified proper condition of pleated air filter and confirmed adequate airflow through system. All components found operating within normal parameters.
Completed scheduled cooling maintenance visit on 7-year-old air conditioning system. Performed comprehensive inspection of air handler unit, including examination of evaporator coil and heat exchanger assembly. Verified proper condition of pleated air filter and confirmed adequate airflow through system. All components found operating within normal parameters.
Stephanie E.
Stephanie E. Checked in
Completed scheduled cooling maintenance visit on 7-year-old air conditioning system. Performed comprehensive inspection of air handler unit, including examination of evaporator coil and heat exchanger assembly. Verified proper condition of pleated air filter and confirmed adequate airflow through system. All components found operating within normal parameters.
Kent, OH 44240
Successfully installed a 10 KW Generac standby generator with a 16-circuit automatic transfer switch. Ran approximately 30 feet of gas line from the existing meter to the generator location to provide adequate fuel supply. Mounted the transfer switch in the utility area and completed all necessary electrical connections between the main service panel, transfer switch, and generator unit. Wired 16 designated circuits through the transfer switch to ensure automatic power transfer during utility outages. Tested all transfer switch operations and verified proper generator startup sequence and load transfer functionality. No utility disconnect was required per electrical inspection authority approval. All work completed to manufacturer specifications and local electrical code requirements.
Successfully installed a 10 KW Generac standby generator with a 16-circuit automatic transfer switch. Ran approximately 30 feet of gas line from the existing meter to the generator location to provide adequate fuel supply. Mounted the transfer switch in the utility area and completed all necessary electrical connections between the main service panel, transfer switch, and generator unit. Wired 16 designated circuits through the transfer switch to ensure automatic power transfer during utility outages. Tested all transfer switch operations and verified proper generator startup sequence and load transfer functionality. No utility disconnect was required per electrical inspection authority approval. All work completed to manufacturer specifications and local electrical code requirements.
Steven M.
Steven M. Checked in
Successfully installed a 10 KW Generac standby generator with a 16-circuit automatic transfer switch. Ran approximately 30 feet of gas line from the existing meter to the generator location to provide adequate fuel supply. Mounted the transfer switch in the utility area and completed all necessary electrical connections between the main service panel, transfer switch, and generator unit. Wired 16 designated circuits through the transfer switch to ensure automatic power transfer during utility outages. Tested all transfer switch operations and verified proper generator startup sequence and load transfer functionality. No utility disconnect was required per electrical inspection authority approval. All work completed to manufacturer specifications and local electrical code requirements.
Kent, OH 44240
Performed comprehensive descaling service on Navien tankless water heater/boiler combo unit. Flushed system with descaling solution to remove mineral buildup and maintain optimal heat exchanger efficiency. Inspected all connections, copper piping runs, valves, and mounting hardware for proper operation and secure installation upon completion of the maintenance procedure.
Performed comprehensive descaling service on Navien tankless water heater/boiler combo unit. Flushed system with descaling solution to remove mineral buildup and maintain optimal heat exchanger efficiency. Inspected all connections, copper piping runs, valves, and mounting hardware for proper operation and secure installation upon completion of the maintenance procedure.
Karl M.
Karl M. Checked in
Performed comprehensive descaling service on Navien tankless water heater/boiler combo unit. Flushed system with descaling solution to remove mineral buildup and maintain optimal heat exchanger efficiency. Inspected all connections, copper piping runs, valves, and mounting hardware for proper operation and secure installation upon completion of the maintenance procedure.
Kent, OH 44240
Completed electrical assessment for standby generator installation. Documented existing electrical service configuration including main breaker panel with current circuit directory and secondary distribution panel. Photographed panel locations, available installation space near existing electrical infrastructure, and exposed wall framing in preparation area. Confirmed existing electrical system specifications and identified optimal connection points for generator transfer switch integration with current service panels.
Completed electrical assessment for standby generator installation. Documented existing electrical service configuration including main breaker panel with current circuit directory and secondary distribution panel. Photographed panel locations, available installation space near existing electrical infrastructure, and exposed wall framing in preparation area. Confirmed existing electrical system specifications and identified optimal connection points for generator transfer switch integration with current service panels.
Dave T.
Dave T. Checked in
Completed electrical assessment for standby generator installation. Documented existing electrical service configuration including main breaker panel with current circuit directory and secondary distribution panel. Photographed panel locations, available installation space near existing electrical infrastructure, and exposed wall framing in preparation area. Confirmed existing electrical system specifications and identified optimal connection points for generator transfer switch integration with current service panels.
Kent, OH 44240
Completed MVP cooling maintenance visit on 3-year-old system. Inspected and tested electrical components including fuse block with four copper fuses, verified proper ratings and connections. Performed electrical diagnostics using clamp meter to measure voltage, amperage, and system performance at outdoor condensing unit. All electrical components tested within normal operating parameters and system operating efficiently.
Completed MVP cooling maintenance visit on 3-year-old system. Inspected and tested electrical components including fuse block with four copper fuses, verified proper ratings and connections. Performed electrical diagnostics using clamp meter to measure voltage, amperage, and system performance at outdoor condensing unit. All electrical components tested within normal operating parameters and system operating efficiently.
Jesus M.
Jesus M. Checked in
Completed MVP cooling maintenance visit on 3-year-old system. Inspected and tested electrical components including fuse block with four copper fuses, verified proper ratings and connections. Performed electrical diagnostics using clamp meter to measure voltage, amperage, and system performance at outdoor condensing unit. All electrical components tested within normal operating parameters and system operating efficiently.
Kent, OH 44240
Completed preventive maintenance on two cooling systems: a Mitsubishi Electric ductless mini-split and a Lennox central air conditioning unit (8 years old). Inspected electrical components including capacitor and wiring connections, verified proper operation of both systems, and documented equipment condition with photos per recurring service agreement requirements.
Completed preventive maintenance on two cooling systems: a Mitsubishi Electric ductless mini-split and a Lennox central air conditioning unit (8 years old). Inspected electrical components including capacitor and wiring connections, verified proper operation of both systems, and documented equipment condition with photos per recurring service agreement requirements.
Jibreel H.
Jibreel H. Checked in
Completed preventive maintenance on two cooling systems: a Mitsubishi Electric ductless mini-split and a Lennox central air conditioning unit (8 years old). Inspected electrical components including capacitor and wiring connections, verified proper operation of both systems, and documented equipment condition with photos per recurring service agreement requirements.
Kent, OH 44240
Completed comprehensive cooling season tune-up on residential air conditioning system. Performed visual inspection of outdoor condenser unit, verified proper operation of dual run capacitor and Honeywell relay control module, checked all electrical connections and wiring terminations within control panel for tightness and proper insulation. All components found operating within normal parameters and system ready for cooling season.
Completed comprehensive cooling season tune-up on residential air conditioning system. Performed visual inspection of outdoor condenser unit, verified proper operation of dual run capacitor and Honeywell relay control module, checked all electrical connections and wiring terminations within control panel for tightness and proper insulation. All components found operating within normal parameters and system ready for cooling season.
Jibreel H.
Jibreel H. Checked in
Completed comprehensive cooling season tune-up on residential air conditioning system. Performed visual inspection of outdoor condenser unit, verified proper operation of dual run capacitor and Honeywell relay control module, checked all electrical connections and wiring terminations within control panel for tightness and proper insulation. All components found operating within normal parameters and system ready for cooling season.
Kent, OH 44240
Performed routine maintenance on 13-year-old air conditioning system. Inspected electrical components, contactor, and blower motor; verified all connections secure and functioning properly. Cleaned condenser coil and checked refrigerant levels to ensure optimal system performance.
Performed routine maintenance on 13-year-old air conditioning system. Inspected electrical components, contactor, and blower motor; verified all connections secure and functioning properly. Cleaned condenser coil and checked refrigerant levels to ensure optimal system performance.
Hershel M.
Hershel M. Checked in
Performed routine maintenance on 13-year-old air conditioning system. Inspected electrical components, contactor, and blower motor; verified all connections secure and functioning properly. Cleaned condenser coil and checked refrigerant levels to ensure optimal system performance.
Kent, OH 44240
Installed a 200 amp meter main disconnect combo with exterior service upgrade, running SER cable into the existing panel with proper ground bar installation and separation of ground and neutral conductors. Installed a dedicated 60 amp circuit using #6 copper wire routed around the exterior of the structure to the driveway for an electric vehicle charger, including a disconnect at the charging location. Upgraded the main electrical grounding system to current code requirements, including installation of new ground rods, hot water tank bonding, and main waterline grounding, and added a whole home surge protector to protect the electrical system.
Installed a 200 amp meter main disconnect combo with exterior service upgrade, running SER cable into the existing panel with proper ground bar installation and separation of ground and neutral conductors. Installed a dedicated 60 amp circuit using #6 copper wire routed around the exterior of the structure to the driveway for an electric vehicle charger, including a disconnect at the charging location. Upgraded the main electrical grounding system to current code requirements, including installation of new ground rods, hot water tank bonding, and main waterline grounding, and added a whole home surge protector to protect the electrical system.
Austin B.
Austin B. Checked in
Installed a 200 amp meter main disconnect combo with exterior service upgrade, running SER cable into the existing panel with proper ground bar installation and separation of ground and neutral conductors. Installed a dedicated 60 amp circuit using #6 copper wire routed around the exterior of the structure to the driveway for an electric vehicle charger, including a disconnect at the charging location. Upgraded the main electrical grounding system to current code requirements, including installation of new ground rods, hot water tank bonding, and main waterline grounding, and added a whole home surge protector to protect the electrical system.
Kent, OH 44240
Repaired actively corroded copper water line located above the laundry sink in the basement. Replaced deteriorated washing machine supply hoses and installed new 1/2" boiler drains to prevent future leaks and water damage.
Repaired actively corroded copper water line located above the laundry sink in the basement. Replaced deteriorated washing machine supply hoses and installed new 1/2" boiler drains to prevent future leaks and water damage.
Karl M.
Karl M. Checked in
Repaired actively corroded copper water line located above the laundry sink in the basement. Replaced deteriorated washing machine supply hoses and installed new 1/2" boiler drains to prevent future leaks and water damage.
Kent, OH 44240
Completed MVP cooling maintenance visit on 7-year-old air conditioning system. Inspected air handler unit and found heavily soiled pleated air filter with significant dust and debris accumulation throughout accordion-style folds. Examined control board assembly, verifying proper operation of relays, integrated circuits, and electrical connections. All wire harnesses, connectors, and circuit board components found in good working condition with no signs of damage or failure.
Completed MVP cooling maintenance visit on 7-year-old air conditioning system. Inspected air handler unit and found heavily soiled pleated air filter with significant dust and debris accumulation throughout accordion-style folds. Examined control board assembly, verifying proper operation of relays, integrated circuits, and electrical connections. All wire harnesses, connectors, and circuit board components found in good working condition with no signs of damage or failure.
Stephanie E.
Stephanie E. Checked in
Completed MVP cooling maintenance visit on 7-year-old air conditioning system. Inspected air handler unit and found heavily soiled pleated air filter with significant dust and debris accumulation throughout accordion-style folds. Examined control board assembly, verifying proper operation of relays, integrated circuits, and electrical connections. All wire harnesses, connectors, and circuit board components found in good working condition with no signs of damage or failure.
Kent, OH 44240
Replaced defective light switch in century-old residential property, accessing work area through rear entrance as requested. Successfully installed new switch to restore proper electrical control of basement utility area lighting, ensuring safe operation in compliance with current electrical codes while respecting the home's vintage wiring configuration.
Replaced defective light switch in century-old residential property, accessing work area through rear entrance as requested. Successfully installed new switch to restore proper electrical control of basement utility area lighting, ensuring safe operation in compliance with current electrical codes while respecting the home's vintage wiring configuration.
Steven M.
Steven M. Checked in
Replaced defective light switch in century-old residential property, accessing work area through rear entrance as requested. Successfully installed new switch to restore proper electrical control of basement utility area lighting, ensuring safe operation in compliance with current electrical codes while respecting the home's vintage wiring configuration.
Kent, OH 44240
Responded to service call for malfunctioning garbage disposal and loose second-floor toilet. Assessed garbage disposal unit and confirmed motor failure due to burnout. Evaluated second-floor toilet instability caused by broken mounting bolts at the base, which occurred during previous tightening attempt. Documented existing conditions including deteriorated toilet bowl condition and missing floor tiles around toilet base requiring future attention.
Responded to service call for malfunctioning garbage disposal and loose second-floor toilet. Assessed garbage disposal unit and confirmed motor failure due to burnout. Evaluated second-floor toilet instability caused by broken mounting bolts at the base, which occurred during previous tightening attempt. Documented existing conditions including deteriorated toilet bowl condition and missing floor tiles around toilet base requiring future attention.
Isaiah H.
Isaiah H. Checked in
Responded to service call for malfunctioning garbage disposal and loose second-floor toilet. Assessed garbage disposal unit and confirmed motor failure due to burnout. Evaluated second-floor toilet instability caused by broken mounting bolts at the base, which occurred during previous tightening attempt. Documented existing conditions including deteriorated toilet bowl condition and missing floor tiles around toilet base requiring future attention.
Kent, OH 44240
Kent, OH - Corrected failed electrical inspection by properly removing grounding electrode conductors that were previously cut and left attached to the neutral bar, eliminating potential for induced current. Reconnected existing Ufer ground and established proper grounding connection to the transfer switch, which serves as the first means of disconnect per code requirements.
Logan H.
Logan H. Checked in
Corrected failed electrical inspection by properly removing grounding electrode conductors that were previously cut and left attached to the neutral bar, eliminating potential for induced current. Reconnected existing Ufer ground and established proper grounding connection to the transfer switch, which serves as the first means of disconnect per code requirements.
Kent, OH 44240
Kent, OH - Responded to service call for non-functioning kitchen outlets. Troubleshot electrical circuits, identified faulty receptacles, and replaced defective outlets to restore power. Verified proper operation of all kitchen receptacles upon completion and ensured all connections met code requirements.
Landon M.
Landon M. Checked in
Responded to service call for non-functioning kitchen outlets. Troubleshot electrical circuits, identified faulty receptacles, and replaced defective outlets to restore power. Verified proper operation of all kitchen receptacles upon completion and ensured all connections met code requirements.
Kent, OH 44240

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image