Schedule Service

Top-Rated Home Services in North Royalton, OH

HVAC professional installing an new gas heating system in a home

Because your home relies on a slew of appliances to operate appropriately, it’s important to hire a team of professionals for service. Blind & Sons offers an extensive list of services to benefit the entirety of your home, including heating, cooling, and plumbing! With years of experience in the industry paired with the field’s leading tools and methods, we’ll complete each project with ease and proficiency.

In need of HVAC or plumbing help? Call us today at 330-362-9232 or contact us online to get started.

Living in North Royalton, OH

Set against the backdrop of northeast Ohio’s rolling hills, North Royalton offers a welcoming atmosphere rooted in tradition and community. With its mix of charming residential areas, expansive green spaces, and highly rated schools, this suburban gem is ideal for families and anyone looking for a peaceful place to call home.

Nature lovers enjoy the many recreational opportunities found at Memorial Park and nearby Metroparks, while history buffs appreciate the town’s small touches of heritage woven throughout its neighborhoods. From backyard barbecues to seasonal festivals and farmers markets, North Royalton fosters a strong sense of belonging.

At Blind & Sons, we’re proud to serve the homeowners of North Royalton. We understand that this community values comfort, safety, and reliability—and we’re committed to delivering just that. Whether you’re dealing with a sudden HVAC issue, a leaky pipe, or a flickering light, our team is ready to bring trusted expertise to your doorstep, helping you take care of your home with confidence.

Need Services?

Heating Services

Winters in North Royalton, Ohio, can be brutal — that’s why it’s crucial to ensure your home’s heater is ready to stand the test of time! From furnaces to boilers, our heating services are designed with your comfort and well-being in mind. These services include:

Furnaces

Our furnace offerings are affordable and trusted, and we proudly service all makes and models for your convenience! The furnace services provided by Blind & Sons include:

Check out our maintenance plan online today!

Boilers

If your home stays warm with the help of a boiler, we’ve got services that will keep it in tiptop shape. No matter your need, we’re bound to have a service that’s right for you. Our boiler services include:

Call today at 330-362-9232 to learn more about our boiler services!

Need Services?

Cooling Services

Stay cool and cozy throughout the hotter months with cooling services from Blind & Sons:

AC Repair

When issues with your air conditioner are starting to affect your comfort, an AC repair is due. Our team will be there to diagnose the issue and offer a repair solution as needed. We also offer emergency AC repair because we realize that sometimes, issues just can’t wait! Keep an eye out for the following signs that your AC needs repairs:

  • Lack of airflow
  • Uneven cooling
  • Unusually high utility bills
  • Weird noises, such as banging, squealing, or clanking
  • Leaking refrigerant or water around the system
  • AC blowing warm air
  • Ice forming on the unit
  • Unresponsive or inaccurate thermostat

AC Installation/Replacement

If you’re in the midst of a new build or need a unit replacement, we’ve got you covered! Our AC installation and replacement services are designed to ensure your home is fitted with the best possible unit, and we will install it properly and test it to make sure it’s working well.

AC Maintenance

The best way to keep your unit’s components in check is by having maintenance performed annually by a professional. Blind & Sons offers comprehensive maintenance services that will inspect your unit wholly and provide cleanings and tune-ups as needed. We also offer an HVAC maintenance plan that makes scheduling a breeze!

Heat Pumps

Heat pumps are a wonderful HVAC alternative as they provide both heating and cooling depending on your needs. Blind & Sons offers a comprehensive list of heat pump services for your benefit, including:

Need Services?

Emergency HVAC Service

open electrical panel with circuit breakers visible

If your heater suddenly shuts down or your AC can’t keep up with your cooling needs during a heat wave, Blind & Sons is here to help! Our team is available because we know that HVAC emergencies can happen at the most inconvenient times. So, whether your issue is occurring in the middle of the night or during the weekend, don’t hesitate to call on our team. We’ll be out as soon as possible to repair your air conditioner or heating system.

If your AC or furnace issue can’t wait until “normal business hours,” don’t fret! Call Blind & Sons at 330-362-9232 for speedy repair services.

Plumbing in North Royalton

Your home requires reliable plumbing to knock out day-to-day tasks. You need to be able to depend on your appliances for duties such as cooking, bathing, and laundry. Blind & Sons works hard to keep homeowners’ plumbing systems working well!

Water Heaters

Your water heater works overtime to provide you with hot water for bathing, washing dishes, and more. Our water heater services will guarantee you will never go hot water, so call us for:

Check out the full list of our plumbing services here!

Trust in Blind & Sons for Your HVAC & Plumbing Needs!

Blind & Sons has been establishing our place in the HVAC and plumbing industry since 1937, and we’ve worked tirelessly to develop our skills and hone our craft so that we can deliver exceptional results to our North Royalton community. With over 80 years of experience, we will never quit unless 100% satisfaction is achieved. We also offer warranties and guarantees for added peace of mind!

By calling 330-362-9232, you can learn more about what we can do for you and schedule an appointment at a time that works best for you.

 

Recent Jobs and Reviews in North Royalton, OH

North Royalton, OH at a glance

Blind and Sons has completed 20 jobs in North Royalton, OH between September 2026 and November 2026.

The most recent job was on November 9, 2026.

Blind and Sons has completed 116 jobs in North Royalton, OH in the last 12 months.

Job Locations and Reviews

Inspected the doorbell system, including the chime unit and main electrical panel area, and traced the low-voltage circuit to diagnose the malfunction. Rewired the chime unit's terminal connections, securing the transformer and button wiring to the correct terminals, and tested the circuit to confirm proper chime operation.
Inspected the doorbell system, including the chime unit and main electrical panel area, and traced the low-voltage circuit to diagnose the malfunction. Rewired the chime unit's terminal connections, securing the transformer and button wiring to the correct terminals, and tested the circuit to confirm proper chime operation.
Matthew H.
Matthew H. Checked in
Inspected the doorbell system, including the chime unit and main electrical panel area, and traced the low-voltage circuit to diagnose the malfunction. Rewired the chime unit's terminal connections, securing the transformer and button wiring to the correct terminals, and tested the circuit to confirm proper chime operation.
North Royalton, OH 44133
Performed heating-season maintenance on an 11-year-old heat pump system, inspecting the outdoor condenser's electrical compartment, including the 60-amp disconnect/breaker, high- and low-voltage wiring and connections, run capacitors, contactor, and control board. All components were found in good condition with no evidence of frost, rust, corrosion, or burn marks, and the unit is operating properly.
Performed heating-season maintenance on an 11-year-old heat pump system, inspecting the outdoor condenser's electrical compartment, including the 60-amp disconnect/breaker, high- and low-voltage wiring and connections, run capacitors, contactor, and control board. All components were found in good condition with no evidence of frost, rust, corrosion, or burn marks, and the unit is operating properly.
Kevin D.
Kevin D. Checked in
Performed heating-season maintenance on an 11-year-old heat pump system, inspecting the outdoor condenser's electrical compartment, including the 60-amp disconnect/breaker, high- and low-voltage wiring and connections, run capacitors, contactor, and control board. All components were found in good condition with no evidence of frost, rust, corrosion, or burn marks, and the unit is operating properly.
North Royalton, OH 44133
Installed new 90% AFUE furnace with new venting/flue piping. Performed startup and verified operation, measuring a 53.8°F temperature reading at the duct/plenum and 1.76 inWC static pressure with a dual-port manometer to confirm proper system airflow and performance.
Installed new 90% AFUE furnace with new venting/flue piping. Performed startup and verified operation, measuring a 53.8°F temperature reading at the duct/plenum and 1.76 inWC static pressure with a dual-port manometer to confirm proper system airflow and performance.
Ethan F.
Ethan F. Checked in
Installed new 90% AFUE furnace with new venting/flue piping. Performed startup and verified operation, measuring a 53.8°F temperature reading at the duct/plenum and 1.76 inWC static pressure with a dual-port manometer to confirm proper system airflow and performance.
North Royalton, OH 44133
Updated the electrical service panel to accommodate a portable generator connection, reorganizing and securing the interior wiring and verifying breaker labeling for the A/C, range, office, garage, and barn circuits. Supplied color-coded conductors (white, red, black, green) for the panel modifications, with cable terminations made through proper connectors at the OSB-mounted enclosure on the CMU wall.
Updated the electrical service panel to accommodate a portable generator connection, reorganizing and securing the interior wiring and verifying breaker labeling for the A/C, range, office, garage, and barn circuits. Supplied color-coded conductors (white, red, black, green) for the panel modifications, with cable terminations made through proper connectors at the OSB-mounted enclosure on the CMU wall.
Austin B.
Austin B. Checked in
Updated the electrical service panel to accommodate a portable generator connection, reorganizing and securing the interior wiring and verifying breaker labeling for the A/C, range, office, garage, and barn circuits. Supplied color-coded conductors (white, red, black, green) for the panel modifications, with cable terminations made through proper connectors at the OSB-mounted enclosure on the CMU wall.
North Royalton, OH 44133
Performed annual preventive maintenance on the furnace, inspecting the evaporator coil, refrigerant lines, and copper fittings, and noting frost accumulation on the coil U-bends, surface oxidation on the copper tubing, and moderate rust on a mounting bracket. Inspected the blower wheel and found the blades intact and free of rust or damage, with only a light dust coating. Unit was left operational, with the rusted bracket and coil frosting recommended for further evaluation.
Performed annual preventive maintenance on the furnace, inspecting the evaporator coil, refrigerant lines, and copper fittings, and noting frost accumulation on the coil U-bends, surface oxidation on the copper tubing, and moderate rust on a mounting bracket. Inspected the blower wheel and found the blades intact and free of rust or damage, with only a light dust coating. Unit was left operational, with the rusted bracket and coil frosting recommended for further evaluation.
Mario M.
Mario M. Checked in
Performed annual preventive maintenance on the furnace, inspecting the evaporator coil, refrigerant lines, and copper fittings, and noting frost accumulation on the coil U-bends, surface oxidation on the copper tubing, and moderate rust on a mounting bracket. Inspected the blower wheel and found the blades intact and free of rust or damage, with only a light dust coating. Unit was left operational, with the rusted bracket and coil frosting recommended for further evaluation.
North Royalton, OH 44133
Arrived to find the system non-operational. Diagnostics determined the pressure switch was failing to open, preventing proper furnace operation, and the switch was corrected to restore operation. Replacement of the pressure switch is recommended to prevent an untimely failure, and corrosion was noted on the gas manifold and shelf beneath the inducer motor.
Arrived to find the system non-operational. Diagnostics determined the pressure switch was failing to open, preventing proper furnace operation, and the switch was corrected to restore operation. Replacement of the pressure switch is recommended to prevent an untimely failure, and corrosion was noted on the gas manifold and shelf beneath the inducer motor.
Mario M.
Mario M. Checked in
Arrived to find the system non-operational. Diagnostics determined the pressure switch was failing to open, preventing proper furnace operation, and the switch was corrected to restore operation. Replacement of the pressure switch is recommended to prevent an untimely failure, and corrosion was noted on the gas manifold and shelf beneath the inducer motor.
North Royalton, OH 44133
Installed a new gas supply line to the kitchen range, tapping into the main trunk line located directly below and running rigid black iron pipe to the appliance location per the customer's request for hard pipe. Connections were threaded and sealed with gas-rated pipe dope, followed by a pressure test and leak check to verify a safe, code-compliant installation.
Installed a new gas supply line to the kitchen range, tapping into the main trunk line located directly below and running rigid black iron pipe to the appliance location per the customer's request for hard pipe. Connections were threaded and sealed with gas-rated pipe dope, followed by a pressure test and leak check to verify a safe, code-compliant installation.
Jared K.
Jared K. Checked in
Installed a new gas supply line to the kitchen range, tapping into the main trunk line located directly below and running rigid black iron pipe to the appliance location per the customer's request for hard pipe. Connections were threaded and sealed with gas-rated pipe dope, followed by a pressure test and leak check to verify a safe, code-compliant installation.
North Royalton, OH 44133
Performed a complete furnace tune-up, inspecting the burner compartment, inducer motor assembly, gas valve, pressure switch, control board, and wiring harnesses. Observed surface rust and debris buildup on the burner tubes and compartment floor, which was noted for monitoring and cleaned as part of the service. All other components were in typical condition with no signs of breakage or ice, and the system was verified for proper operation.
Performed a complete furnace tune-up, inspecting the burner compartment, inducer motor assembly, gas valve, pressure switch, control board, and wiring harnesses. Observed surface rust and debris buildup on the burner tubes and compartment floor, which was noted for monitoring and cleaned as part of the service. All other components were in typical condition with no signs of breakage or ice, and the system was verified for proper operation.
Mario M.
Mario M. Checked in
Performed a complete furnace tune-up, inspecting the burner compartment, inducer motor assembly, gas valve, pressure switch, control board, and wiring harnesses. Observed surface rust and debris buildup on the burner tubes and compartment floor, which was noted for monitoring and cleaned as part of the service. All other components were in typical condition with no signs of breakage or ice, and the system was verified for proper operation.
North Royalton, OH 44133
North Royalton, OH - Responded to a no-heat call on a Lennox gas furnace, approximately one year old, after the system was switched over to heating mode. Inspected the furnace and surrounding components, including the gas piping, PVC vent and condensate lines, electrical connections, and supply plenum, and found no visible damage, corrosion, or ice formation. Performed diagnostics on the heating sequence to verify operation, and the unit is now running and producing heat.
Kevin D.
Kevin D. Checked in
Responded to a no-heat call on a Lennox gas furnace, approximately one year old, after the system was switched over to heating mode. Inspected the furnace and surrounding components, including the gas piping, PVC vent and condensate lines, electrical connections, and supply plenum, and found no visible damage, corrosion, or ice formation. Performed diagnostics on the heating sequence to verify operation, and the unit is now running and producing heat.
North Royalton, OH 44133
North Royalton, OH - Diagnosed an inoperative exterior lamp post fixture that did not respond to a bulb replacement, testing the circuit and fixture components to isolate the fault. Replaced the lantern-style lamp top with the customer-supplied unit, secured the new head to the post, and restored power. Verified proper operation of the fixture.
Eric L.
Eric L. Checked in
Diagnosed an inoperative exterior lamp post fixture that did not respond to a bulb replacement, testing the circuit and fixture components to isolate the fault. Replaced the lantern-style lamp top with the customer-supplied unit, secured the new head to the post, and restored power. Verified proper operation of the fixture.
North Royalton, OH 44133
Performed annual maintenance on a 22-year-old gas furnace, inspecting the heat exchanger section, gas valve assembly, wiring, and gas piping, with no visible rust, breakage, or damage noted in the furnace cabinet. Filter had already been replaced by the customer. Inspected the evaporator coil cabinet and observed surface corrosion and rust spotting on the coil edge and cabinet base, along with mineral residue on the cabinet wall, and recommend monitoring or further evaluation of the coil.
Performed annual maintenance on a 22-year-old gas furnace, inspecting the heat exchanger section, gas valve assembly, wiring, and gas piping, with no visible rust, breakage, or damage noted in the furnace cabinet. Filter had already been replaced by the customer. Inspected the evaporator coil cabinet and observed surface corrosion and rust spotting on the coil edge and cabinet base, along with mineral residue on the cabinet wall, and recommend monitoring or further evaluation of the coil.
Mario M.
Mario M. Checked in
Performed annual maintenance on a 22-year-old gas furnace, inspecting the heat exchanger section, gas valve assembly, wiring, and gas piping, with no visible rust, breakage, or damage noted in the furnace cabinet. Filter had already been replaced by the customer. Inspected the evaporator coil cabinet and observed surface corrosion and rust spotting on the coil edge and cabinet base, along with mineral residue on the cabinet wall, and recommend monitoring or further evaluation of the coil.
North Royalton, OH 44133
Completed MVP furnace maintenance service including full system inspection and air filter replacement. Removed heavily soiled pleated air filter showing significant dust and particle accumulation, installed new filter with proper seating in mounting frame, and verified all refrigerant lines and connections were secure with no visible leaks or damage.
Completed MVP furnace maintenance service including full system inspection and air filter replacement. Removed heavily soiled pleated air filter showing significant dust and particle accumulation, installed new filter with proper seating in mounting frame, and verified all refrigerant lines and connections were secure with no visible leaks or damage.
Mario M.
Mario M. Checked in
Completed MVP furnace maintenance service including full system inspection and air filter replacement. Removed heavily soiled pleated air filter showing significant dust and particle accumulation, installed new filter with proper seating in mounting frame, and verified all refrigerant lines and connections were secure with no visible leaks or damage.
North Royalton, OH 44133
Responded to outdoor porch light fixture with damaged wiring caused by animal activity. Upon inspection, found wires had been chewed through, rendering the fixture inoperable. Rewired the affected circuit with new conductors, ensuring proper connections and code compliance. Inspected electrical panel and meter installation to verify circuit integrity and proper grounding. Documented existing conditions and completed repairs to restore safe operation of the outdoor lighting fixture.
Responded to outdoor porch light fixture with damaged wiring caused by animal activity. Upon inspection, found wires had been chewed through, rendering the fixture inoperable. Rewired the affected circuit with new conductors, ensuring proper connections and code compliance. Inspected electrical panel and meter installation to verify circuit integrity and proper grounding. Documented existing conditions and completed repairs to restore safe operation of the outdoor lighting fixture.
Austin B.
Austin B. Checked in
Responded to outdoor porch light fixture with damaged wiring caused by animal activity. Upon inspection, found wires had been chewed through, rendering the fixture inoperable. Rewired the affected circuit with new conductors, ensuring proper connections and code compliance. Inspected electrical panel and meter installation to verify circuit integrity and proper grounding. Documented existing conditions and completed repairs to restore safe operation of the outdoor lighting fixture.
North Royalton, OH 44133
Completed scheduled maintenance visit for MVP customer's Lennox HVAC system. Performed standard cooling season inspection, verified furnace unit operation, and confirmed electrical disconnect box components were functioning properly with all three fuses intact and secure.
Completed scheduled maintenance visit for MVP customer's Lennox HVAC system. Performed standard cooling season inspection, verified furnace unit operation, and confirmed electrical disconnect box components were functioning properly with all three fuses intact and secure.
Kevin D.
Kevin D. Checked in
Completed scheduled maintenance visit for MVP customer's Lennox HVAC system. Performed standard cooling season inspection, verified furnace unit operation, and confirmed electrical disconnect box components were functioning properly with all three fuses intact and secure.
North Royalton, OH 44133
Completed MVP heating maintenance service on schedule. Performed comprehensive system inspection including blower assembly examination and condensate drain verification. All components found operating within normal parameters with blower wheel showing proper rotation and drainage system functioning correctly.
Completed MVP heating maintenance service on schedule. Performed comprehensive system inspection including blower assembly examination and condensate drain verification. All components found operating within normal parameters with blower wheel showing proper rotation and drainage system functioning correctly.
Taylor F.
Taylor F. Checked in
Completed MVP heating maintenance service on schedule. Performed comprehensive system inspection including blower assembly examination and condensate drain verification. All components found operating within normal parameters with blower wheel showing proper rotation and drainage system functioning correctly.
North Royalton, OH 44133
Responded to service call for toilet leaking at base. Upon inspection, identified failed wax ring and mounting hardware causing water seepage. Documented existing conditions with photos showing toilet tank components and fill valve assembly. Ordered replacement parts for return visit to complete repairs, including new wax ring and mounting bolts to properly reseal toilet base and eliminate leak.
Responded to service call for toilet leaking at base. Upon inspection, identified failed wax ring and mounting hardware causing water seepage. Documented existing conditions with photos showing toilet tank components and fill valve assembly. Ordered replacement parts for return visit to complete repairs, including new wax ring and mounting bolts to properly reseal toilet base and eliminate leak.
Isaiah H.
Isaiah H. Checked in
Responded to service call for toilet leaking at base. Upon inspection, identified failed wax ring and mounting hardware causing water seepage. Documented existing conditions with photos showing toilet tank components and fill valve assembly. Ordered replacement parts for return visit to complete repairs, including new wax ring and mounting bolts to properly reseal toilet base and eliminate leak.
North Royalton, OH 44133
Replaced three customer-supplied smoke detectors in bedroom locations. All units were successfully installed and tested for proper operation, with indicator lights confirming functionality upon completion.
Replaced three customer-supplied smoke detectors in bedroom locations. All units were successfully installed and tested for proper operation, with indicator lights confirming functionality upon completion.
Eric L.
Eric L. Checked in
Replaced three customer-supplied smoke detectors in bedroom locations. All units were successfully installed and tested for proper operation, with indicator lights confirming functionality upon completion.
North Royalton, OH 44133
Conducted assessment of exterior plumbing system to provide estimate for replacement of pressure reducing valve and outdoor hose bib. Inspected existing outdoor spigot mounted on building exterior and performed water pressure testing using calibrated gauge to evaluate system performance. Documentation included pressure readings and current condition of outdoor faucet assembly and associated fixtures.
Conducted assessment of exterior plumbing system to provide estimate for replacement of pressure reducing valve and outdoor hose bib. Inspected existing outdoor spigot mounted on building exterior and performed water pressure testing using calibrated gauge to evaluate system performance. Documentation included pressure readings and current condition of outdoor faucet assembly and associated fixtures.
Jared K.
Jared K. Checked in
Conducted assessment of exterior plumbing system to provide estimate for replacement of pressure reducing valve and outdoor hose bib. Inspected existing outdoor spigot mounted on building exterior and performed water pressure testing using calibrated gauge to evaluate system performance. Documentation included pressure readings and current condition of outdoor faucet assembly and associated fixtures.
North Royalton, OH 44133
Responded to gas leak emergency on 5-year-old furnace where Columbia Gas had already shut down system for safety. Performed diagnostic testing using digital manometer to measure gas pressure at valve assembly, confirming burner bleeding issue. Inspected gas valve, control wiring connections, and copper supply line for potential failure points. Documented equipment condition with photos showing gas valve assembly, pressure readings, and wire connections to terminals. Furnace remains offline pending further repairs to address gas valve or control box malfunction causing the leak condition.
Responded to gas leak emergency on 5-year-old furnace where Columbia Gas had already shut down system for safety. Performed diagnostic testing using digital manometer to measure gas pressure at valve assembly, confirming burner bleeding issue. Inspected gas valve, control wiring connections, and copper supply line for potential failure points. Documented equipment condition with photos showing gas valve assembly, pressure readings, and wire connections to terminals. Furnace remains offline pending further repairs to address gas valve or control box malfunction causing the leak condition.
Chris G.
Chris G. Checked in
Responded to gas leak emergency on 5-year-old furnace where Columbia Gas had already shut down system for safety. Performed diagnostic testing using digital manometer to measure gas pressure at valve assembly, confirming burner bleeding issue. Inspected gas valve, control wiring connections, and copper supply line for potential failure points. Documented equipment condition with photos showing gas valve assembly, pressure readings, and wire connections to terminals. Furnace remains offline pending further repairs to address gas valve or control box malfunction causing the leak condition.
North Royalton, OH 44133
North Royalton, OH - Replaced malfunctioning Moen tub shower faucet with new Moen Chateau valve assembly. Cut and installed new access panel for valve access, and installed two shut-off valves for isolation purposes to facilitate future maintenance and repairs.
Nick L.
Nick L. Checked in
Replaced malfunctioning Moen tub shower faucet with new Moen Chateau valve assembly. Cut and installed new access panel for valve access, and installed two shut-off valves for isolation purposes to facilitate future maintenance and repairs.
North Royalton, OH 44133

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image