Professional Heating, Cooling, Plumbing & Electrical Services in Painesville, OH

soldering of copper water pipes. Soldering of water distribution pipelines in the apartment. Copper plumbing pipe. Home repair, remodeling concept. High quality photo

Your home in Painesville is more than just where you live-it’s where your family makes memories, feels safe, and builds the future. Protecting that space means making sure every system inside it is dependable and built to last. At Blind & Sons, we’ve been helping Northeast Ohio families protect their homes for over 80 years. We know that in Painesville, from the lake-effect snow to humid summers, your heating, cooling, plumbing, and electrical systems work overtime. Our job is to make sure they keep running smoothly so you don’t have to worry. Regain your peace of mind by calling 330-362-9232 or contacting us online today!

Local Expertise That Painesville Families Can Trust

Painesville is a city with character-historic Main Street buildings, community gatherings at Veterans Park, and neighborhoods shaped by the beauty of the Grand River. Families here enjoy the small-town feel with the convenience of Lake County living, but they also face weather that can change on a dime. Snowstorms, spring flooding, and summer humidity are part of life in Northeast Ohio. Blind & Sons knows the area and understands these challenges. We design our solutions to meet the unique needs of Painesville homes, whether it’s upgrading an older system in a century-old house or installing modern, energy-efficient equipment in a newer build.

Need Services?

Complete Cooling Services in Painesville, OH

When the summer sun beats down and humidity lingers, your home should be a place of relief. Our Painesville cooling services are built to protect your investment while keeping your family comfortable.

Reliable cooling isn’t just about staying comfortable-it’s about keeping your home and family safe during Painesville’s hottest days.

Safe, Efficient Heating Services for Painesville Winters

Winter here is no joke. Between lake-effect snow and freezing winds, you need a heating system you can count on. Blind & Sons provides heating solutions that safeguard your family against Ohio’s harshest months.

A dependable heating system is more than comfort-it’s a matter of safety and protecting your property from the dangers of extreme cold.

Indoor Air Quality Services in Painesville, OH

The indoor air quality in your Painesville home plays a huge role in your family’s comfort, health, and even your property’s long-term value. Blind & Sons offers professional indoor air quality services in Painesville, OH designed to keep your air fresh, balanced, and safe.

Functioning Plumbing Services in Painesville, OH

Person holding a plunger in a sink

The plumbing in your Painesville home is essential for everyday comfort, and even small issues can lead to expensive damage if ignored. Blind & Sons offers professional plumbing services in Painesville, OH that keep your home protected, your water clean, and your family’s routines running smoothly.

Need Services?

Powerful Electrical Services in Painesville, OH

Your home’s electrical system is the backbone of modern living. From powering appliances to keeping your devices charged, safe and reliable electricity is essential for everyday life in Painesville. Blind & Sons offers professional electrical services in Painesville, OH that keep your home protected, efficient, and up to date.

Contact Blind & Sons for Professional Home Services in Painesville, OH

From AC emergencies in July to frozen pipes in January, Blind & Sons is here year-round to protect your investment and keep your family comfortable. With over 80 years of trusted experience and a commitment to professional service, we’re the partner Painesville homeowners can count on. Call 330-362-9232 today or schedule your appointment online to experience why so many families in Painesville rely on Blind & Sons for heating, cooling, plumbing, and electrical services.

 

Recent Jobs and Reviews in Painesville, OH

Painesville, OH at a glance

Blind and Sons has completed 20 jobs in Painesville, OH between February 2026 and October 2026.

The most recent job was on October 5, 2026.

Blind and Sons has completed 22 jobs in Painesville, OH in the last 12 months.

Job Locations and Reviews

Completed maintenance MVP service on a 4-5 year old steam gas boiler system. Performed comprehensive inspection of blower assembly, verified proper operation of fan impeller and housing components, and checked refrigerant lines and condensate drain tubing for integrity. Reviewed boiler control system parameters and documented control display interface settings for atmospheric venting configuration, confirming all operating modes, status indicators, and error code reference materials were accessible and legible for future diagnostics.
Completed maintenance MVP service on a 4-5 year old steam gas boiler system. Performed comprehensive inspection of blower assembly, verified proper operation of fan impeller and housing components, and checked refrigerant lines and condensate drain tubing for integrity. Reviewed boiler control system parameters and documented control display interface settings for atmospheric venting configuration, confirming all operating modes, status indicators, and error code reference materials were accessible and legible for future diagnostics.
Chris G.
Chris G. Checked in
Completed maintenance MVP service on a 4-5 year old steam gas boiler system. Performed comprehensive inspection of blower assembly, verified proper operation of fan impeller and housing components, and checked refrigerant lines and condensate drain tubing for integrity. Reviewed boiler control system parameters and documented control display interface settings for atmospheric venting configuration, confirming all operating modes, status indicators, and error code reference materials were accessible and legible for future diagnostics.
Painesville, OH 44077
Completed comprehensive tune-up service on 2-year-old Lennox EL17XC1 air conditioning unit and 7-year-old Lennox SL280UH110V60C furnace. Inspected and verified air filter condition, performed electrical diagnostics and temperature differential measurements using digital instrumentation, and confirmed proper operation of all system components. All equipment tested within normal operating parameters with no deficiencies noted.
Completed comprehensive tune-up service on 2-year-old Lennox EL17XC1 air conditioning unit and 7-year-old Lennox SL280UH110V60C furnace. Inspected and verified air filter condition, performed electrical diagnostics and temperature differential measurements using digital instrumentation, and confirmed proper operation of all system components. All equipment tested within normal operating parameters with no deficiencies noted.
Mario M.
Mario M. Checked in
Completed comprehensive tune-up service on 2-year-old Lennox EL17XC1 air conditioning unit and 7-year-old Lennox SL280UH110V60C furnace. Inspected and verified air filter condition, performed electrical diagnostics and temperature differential measurements using digital instrumentation, and confirmed proper operation of all system components. All equipment tested within normal operating parameters with no deficiencies noted.
Painesville, OH 44077
Completed routine tune-up maintenance on both mini-split and heat pump systems, each approximately eight years old. Performed comprehensive inspection of outdoor unit components including refrigerant lines, electrical connections, and compressor assembly. All systems operating within normal parameters with no issues identified or repairs required.
Completed routine tune-up maintenance on both mini-split and heat pump systems, each approximately eight years old. Performed comprehensive inspection of outdoor unit components including refrigerant lines, electrical connections, and compressor assembly. All systems operating within normal parameters with no issues identified or repairs required.
Chris G.
Chris G. Checked in
Completed routine tune-up maintenance on both mini-split and heat pump systems, each approximately eight years old. Performed comprehensive inspection of outdoor unit components including refrigerant lines, electrical connections, and compressor assembly. All systems operating within normal parameters with no issues identified or repairs required.
Painesville, OH 44077
Completed scheduled MVP cooling maintenance visit. Performed system diagnostics using digital multimeter to verify electrical parameters and component functionality. Inspected control board circuitry, sensors, and outdoor disconnect components to ensure proper operation of cooling system.
Completed scheduled MVP cooling maintenance visit. Performed system diagnostics using digital multimeter to verify electrical parameters and component functionality. Inspected control board circuitry, sensors, and outdoor disconnect components to ensure proper operation of cooling system.
Chris G.
Chris G. Checked in
Completed scheduled MVP cooling maintenance visit. Performed system diagnostics using digital multimeter to verify electrical parameters and component functionality. Inspected control board circuitry, sensors, and outdoor disconnect components to ensure proper operation of cooling system.
Painesville, OH 44077
Completed scheduled cooling maintenance visit on 5-year-old air conditioning system. Performed comprehensive inspection of evaporator coil assembly, noting accumulated dust and debris on finned heat exchanger surfaces typical of normal operation. Inspected electronic control board assembly including ECM drive module and verified all wire connections, terminals, and circuit board components were secure and functioning properly.
Completed scheduled cooling maintenance visit on 5-year-old air conditioning system. Performed comprehensive inspection of evaporator coil assembly, noting accumulated dust and debris on finned heat exchanger surfaces typical of normal operation. Inspected electronic control board assembly including ECM drive module and verified all wire connections, terminals, and circuit board components were secure and functioning properly.
Mario M.
Mario M. Checked in
Completed scheduled cooling maintenance visit on 5-year-old air conditioning system. Performed comprehensive inspection of evaporator coil assembly, noting accumulated dust and debris on finned heat exchanger surfaces typical of normal operation. Inspected electronic control board assembly including ECM drive module and verified all wire connections, terminals, and circuit board components were secure and functioning properly.
Painesville, OH 44077
Completed routine preventive maintenance cooling visit on 4-year-old residential air conditioning system. Performed comprehensive inspection of outdoor condensing unit, verified proper operation of compressor and condenser fan motor, checked refrigerant line connections and electrical components. Unit found in good working condition with normal outdoor weathering; all components operating within manufacturer specifications.
Completed routine preventive maintenance cooling visit on 4-year-old residential air conditioning system. Performed comprehensive inspection of outdoor condensing unit, verified proper operation of compressor and condenser fan motor, checked refrigerant line connections and electrical components. Unit found in good working condition with normal outdoor weathering; all components operating within manufacturer specifications.
John W.
John W. Checked in
Completed routine preventive maintenance cooling visit on 4-year-old residential air conditioning system. Performed comprehensive inspection of outdoor condensing unit, verified proper operation of compressor and condenser fan motor, checked refrigerant line connections and electrical components. Unit found in good working condition with normal outdoor weathering; all components operating within manufacturer specifications.
Painesville, OH 44077
Completed air conditioning tune-up on 2-year-old system. Inspected electrical connections at contactor and terminal block, verified all wiring secure with no signs of overheating or loose terminals. Inspected 16x25x1 air filter showing moderate dirt accumulation and documented condition; filter remains serviceable but should be monitored for replacement at next service interval.
Completed air conditioning tune-up on 2-year-old system. Inspected electrical connections at contactor and terminal block, verified all wiring secure with no signs of overheating or loose terminals. Inspected 16x25x1 air filter showing moderate dirt accumulation and documented condition; filter remains serviceable but should be monitored for replacement at next service interval.
Chris G.
Chris G. Checked in
Completed air conditioning tune-up on 2-year-old system. Inspected electrical connections at contactor and terminal block, verified all wiring secure with no signs of overheating or loose terminals. Inspected 16x25x1 air filter showing moderate dirt accumulation and documented condition; filter remains serviceable but should be monitored for replacement at next service interval.
Painesville, OH 44077
Responded to service call for non-operational air conditioning unit that had been relocated due to recent sewer line excavation work. Performed thorough inspection of outdoor condenser unit and indoor evaporator coil to verify proper reconnection and identify any issues resulting from the relocation. Found outdoor condenser unit properly positioned on concrete pad with refrigerant lines intact. However, discovered indoor evaporator coil heavily contaminated with excessive dust and debris accumulation, significantly restricting airflow and system performance. The dense buildup on coil fins indicated prolonged maintenance neglect that predated the unit relocation. Documented unit condition through photographs showing both outdoor condenser assembly and severely fouled indoor coil. Confirmed all electrical connections and refrigerant lines were properly secured following the move, with no apparent damage from relocation activities.
Responded to service call for non-operational air conditioning unit that had been relocated due to recent sewer line excavation work. Performed thorough inspection of outdoor condenser unit and indoor evaporator coil to verify proper reconnection and identify any issues resulting from the relocation. Found outdoor condenser unit properly positioned on concrete pad with refrigerant lines intact. However, discovered indoor evaporator coil heavily contaminated with excessive dust and debris accumulation, significantly restricting airflow and system performance. The dense buildup on coil fins indicated prolonged maintenance neglect that predated the unit relocation. Documented unit condition through photographs showing both outdoor condenser assembly and severely fouled indoor coil. Confirmed all electrical connections and refrigerant lines were properly secured following the move, with no apparent damage from relocation activities.
Chris G.
Chris G. Checked in
Responded to service call for non-operational air conditioning unit that had been relocated due to recent sewer line excavation work. Performed thorough inspection of outdoor condenser unit and indoor evaporator coil to verify proper reconnection and identify any issues resulting from the relocation. Found outdoor condenser unit properly positioned on concrete pad with refrigerant lines intact. However, discovered indoor evaporator coil heavily contaminated with excessive dust and debris accumulation, significantly restricting airflow and system performance. The dense buildup on coil fins indicated prolonged maintenance neglect that predated the unit relocation. Documented unit condition through photographs showing both outdoor condenser assembly and severely fouled indoor coil. Confirmed all electrical connections and refrigerant lines were properly secured following the move, with no apparent damage from relocation activities.
Painesville, OH 44077
Completed MVP cooling maintenance visit on 20-year-old air conditioning system. Performed standard preventive maintenance inspection including evaluation of electrical control panel, wiring connections, and terminal blocks. Documented existing equipment condition showing normal operational wear and accumulated debris on electrical components. Additionally installed new thermostat per customer request to replace existing unit. System operational upon completion of service.
Completed MVP cooling maintenance visit on 20-year-old air conditioning system. Performed standard preventive maintenance inspection including evaluation of electrical control panel, wiring connections, and terminal blocks. Documented existing equipment condition showing normal operational wear and accumulated debris on electrical components. Additionally installed new thermostat per customer request to replace existing unit. System operational upon completion of service.
Chris G.
Chris G. Checked in
Completed MVP cooling maintenance visit on 20-year-old air conditioning system. Performed standard preventive maintenance inspection including evaluation of electrical control panel, wiring connections, and terminal blocks. Documented existing equipment condition showing normal operational wear and accumulated debris on electrical components. Additionally installed new thermostat per customer request to replace existing unit. System operational upon completion of service.
Painesville, OH 44077
Painesville, OH - Completed exterior electrical conduit installation and mounted ceiling fan with integrated light fixture on covered patio. Fan installed on wooden tongue-and-groove ceiling with proper support and clearance, tested for operation, and recessed lighting verified functional.
Andrew V.
Andrew V. Checked in
Completed exterior electrical conduit installation and mounted ceiling fan with integrated light fixture on covered patio. Fan installed on wooden tongue-and-groove ceiling with proper support and clearance, tested for operation, and recessed lighting verified functional.
Painesville, OH 44077
Completed comprehensive tune-up on 9-year-old R410A air conditioning system. Performed system diagnostics using digital manifold gauges, recording operating pressures of 131.4 psi suction and 344.4 psi discharge with corresponding saturation temperatures of 45.5°F and 105.6°F. Measured superheat at 10.1°F and subcooling at 1.3°F, indicating system is operating within acceptable parameters though subcooling is slightly low. Inspected electrical connections and wiring within unit, verifying all terminations are secure and properly routed. System is functioning properly and ready for continued operation.
Completed comprehensive tune-up on 9-year-old R410A air conditioning system. Performed system diagnostics using digital manifold gauges, recording operating pressures of 131.4 psi suction and 344.4 psi discharge with corresponding saturation temperatures of 45.5°F and 105.6°F. Measured superheat at 10.1°F and subcooling at 1.3°F, indicating system is operating within acceptable parameters though subcooling is slightly low. Inspected electrical connections and wiring within unit, verifying all terminations are secure and properly routed. System is functioning properly and ready for continued operation.
Chris G.
Chris G. Checked in
Completed comprehensive tune-up on 9-year-old R410A air conditioning system. Performed system diagnostics using digital manifold gauges, recording operating pressures of 131.4 psi suction and 344.4 psi discharge with corresponding saturation temperatures of 45.5°F and 105.6°F. Measured superheat at 10.1°F and subcooling at 1.3°F, indicating system is operating within acceptable parameters though subcooling is slightly low. Inspected electrical connections and wiring within unit, verifying all terminations are secure and properly routed. System is functioning properly and ready for continued operation.
Painesville, OH 44077
Performed scheduled two-year maintenance service on residential standby generator. Conducted comprehensive battery testing using diagnostic equipment, which revealed the starting battery requires replacement due to diminished cold cranking amp capacity (340 CCA) and state of health at 58%, despite maintaining full charge at 13.12V. Tested backup battery showing optimal performance with 100% state of health, 100% state of charge, and low internal resistance of 3.96mΩ. Documented all findings with photographs for customer records and recommended immediate battery replacement to ensure reliable generator operation during power outages.
Performed scheduled two-year maintenance service on residential standby generator. Conducted comprehensive battery testing using diagnostic equipment, which revealed the starting battery requires replacement due to diminished cold cranking amp capacity (340 CCA) and state of health at 58%, despite maintaining full charge at 13.12V. Tested backup battery showing optimal performance with 100% state of health, 100% state of charge, and low internal resistance of 3.96mΩ. Documented all findings with photographs for customer records and recommended immediate battery replacement to ensure reliable generator operation during power outages.
Andrew V.
Andrew V. Checked in
Performed scheduled two-year maintenance service on residential standby generator. Conducted comprehensive battery testing using diagnostic equipment, which revealed the starting battery requires replacement due to diminished cold cranking amp capacity (340 CCA) and state of health at 58%, despite maintaining full charge at 13.12V. Tested backup battery showing optimal performance with 100% state of health, 100% state of charge, and low internal resistance of 3.96mΩ. Documented all findings with photographs for customer records and recommended immediate battery replacement to ensure reliable generator operation during power outages.
Painesville, OH 44077
Completed electrical trim-out work for deck installation, including circuit breaker panel configuration and rough-in wiring in basement area. Installed and organized circuit breakers in main electrical panel, with proper labeling and knockout preparation for future expansion. Routed electrical wiring through floor joists and coordinated installation with existing mechanical systems including PVC ductwork. All work performed to code specifications with parts ordered and received prior to final installation.
Completed electrical trim-out work for deck installation, including circuit breaker panel configuration and rough-in wiring in basement area. Installed and organized circuit breakers in main electrical panel, with proper labeling and knockout preparation for future expansion. Routed electrical wiring through floor joists and coordinated installation with existing mechanical systems including PVC ductwork. All work performed to code specifications with parts ordered and received prior to final installation.
Andrew V.
Andrew V. Checked in
Completed electrical trim-out work for deck installation, including circuit breaker panel configuration and rough-in wiring in basement area. Installed and organized circuit breakers in main electrical panel, with proper labeling and knockout preparation for future expansion. Routed electrical wiring through floor joists and coordinated installation with existing mechanical systems including PVC ductwork. All work performed to code specifications with parts ordered and received prior to final installation.
Painesville, OH 44077
Conducted on-site assessment for HVAC system replacement at residential property with 19-year-old existing equipment. Evaluated current Goodman furnace installation in basement mechanical room, noting PVC venting configuration and refrigerant line routing. Documented exterior conditions including deteriorated foundation barrier material near outdoor condensing unit location, with significant damage requiring attention during replacement installation. Photographed existing system components and site conditions to prepare comprehensive replacement estimate for complete HVAC system upgrade.
Conducted on-site assessment for HVAC system replacement at residential property with 19-year-old existing equipment. Evaluated current Goodman furnace installation in basement mechanical room, noting PVC venting configuration and refrigerant line routing. Documented exterior conditions including deteriorated foundation barrier material near outdoor condensing unit location, with significant damage requiring attention during replacement installation. Photographed existing system components and site conditions to prepare comprehensive replacement estimate for complete HVAC system upgrade.
Jordan K.
Jordan K. Checked in
Conducted on-site assessment for HVAC system replacement at residential property with 19-year-old existing equipment. Evaluated current Goodman furnace installation in basement mechanical room, noting PVC venting configuration and refrigerant line routing. Documented exterior conditions including deteriorated foundation barrier material near outdoor condensing unit location, with significant damage requiring attention during replacement installation. Photographed existing system components and site conditions to prepare comprehensive replacement estimate for complete HVAC system upgrade.
Painesville, OH 44077
Installed four customer-provided recessed can lights and one customer-provided ceiling fan in covered patio area with exposed ceiling joists. Completed all electrical connections, secured fixtures to structural framing, and verified proper operation of all lighting and fan controls.
Installed four customer-provided recessed can lights and one customer-provided ceiling fan in covered patio area with exposed ceiling joists. Completed all electrical connections, secured fixtures to structural framing, and verified proper operation of all lighting and fan controls.
Andrew V.
Andrew V. Checked in
Installed four customer-provided recessed can lights and one customer-provided ceiling fan in covered patio area with exposed ceiling joists. Completed all electrical connections, secured fixtures to structural framing, and verified proper operation of all lighting and fan controls.
Painesville, OH 44077
Completed installation of a dedicated 220V circuit for an electric range. Installed conduit with appropriate electrical connections from the service panel to the range location. All work was performed to code specifications and the circuit is now operational.
Completed installation of a dedicated 220V circuit for an electric range. Installed conduit with appropriate electrical connections from the service panel to the range location. All work was performed to code specifications and the circuit is now operational.
Steven M.
Steven M. Checked in
Completed installation of a dedicated 220V circuit for an electric range. Installed conduit with appropriate electrical connections from the service panel to the range location. All work was performed to code specifications and the circuit is now operational.
Painesville, OH 44077
Inspected electrical panel to evaluate feasibility of connecting electric stove to existing 220V dryer circuit. Documented deteriorated insulation on supply lines and assessed current breaker configuration. Determined separate dedicated circuit would be required for code compliance and safe operation of both appliances.
Inspected electrical panel to evaluate feasibility of connecting electric stove to existing 220V dryer circuit. Documented deteriorated insulation on supply lines and assessed current breaker configuration. Determined separate dedicated circuit would be required for code compliance and safe operation of both appliances.
Patrick W.
Patrick W. Checked in
Inspected electrical panel to evaluate feasibility of connecting electric stove to existing 220V dryer circuit. Documented deteriorated insulation on supply lines and assessed current breaker configuration. Determined separate dedicated circuit would be required for code compliance and safe operation of both appliances.
Painesville, OH 44077
Performed lighting upgrade by bypassing ballasts in 3 failing fixtures and installing 6 new LED bulbs to restore proper illumination in commercial space with drop ceiling. Utilized ladder to access ceiling fixtures, completing conversion from fluorescent to direct-wire LED system for improved reliability and energy efficiency.
Performed lighting upgrade by bypassing ballasts in 3 failing fixtures and installing 6 new LED bulbs to restore proper illumination in commercial space with drop ceiling. Utilized ladder to access ceiling fixtures, completing conversion from fluorescent to direct-wire LED system for improved reliability and energy efficiency.
Andrew V.
Andrew V. Checked in
Performed lighting upgrade by bypassing ballasts in 3 failing fixtures and installing 6 new LED bulbs to restore proper illumination in commercial space with drop ceiling. Utilized ladder to access ceiling fixtures, completing conversion from fluorescent to direct-wire LED system for improved reliability and energy efficiency.
Painesville, OH 44077
Completed bypass of ballasts on 10 light fixtures and replaced the ballast in the front foyer light fixture. Work involved accessing ceiling-mounted fixtures using ladder in commercial space with drop ceiling tiles and pendant lighting. Parts were received and installation was completed as scheduled.
Completed bypass of ballasts on 10 light fixtures and replaced the ballast in the front foyer light fixture. Work involved accessing ceiling-mounted fixtures using ladder in commercial space with drop ceiling tiles and pendant lighting. Parts were received and installation was completed as scheduled.
Andrew V.
Andrew V. Checked in
Completed bypass of ballasts on 10 light fixtures and replaced the ballast in the front foyer light fixture. Work involved accessing ceiling-mounted fixtures using ladder in commercial space with drop ceiling tiles and pendant lighting. Parts were received and installation was completed as scheduled.
Painesville, OH 44077
Diagnosed and replaced faulty ballasts in two fluorescent light fixtures - one located in front lobby and another in pharmacy area. Verified proper operation after installation with new compatible ballasts, ensuring all fixtures now function correctly.
Diagnosed and replaced faulty ballasts in two fluorescent light fixtures - one located in front lobby and another in pharmacy area. Verified proper operation after installation with new compatible ballasts, ensuring all fixtures now function correctly.
Andrew V.
Andrew V. Checked in
Diagnosed and replaced faulty ballasts in two fluorescent light fixtures - one located in front lobby and another in pharmacy area. Verified proper operation after installation with new compatible ballasts, ensuring all fixtures now function correctly.
Painesville, OH 44077

 

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image