Schedule Service

Keeping Rocky River Homes Safe, Comfortable & Efficient

open dishwasher with clean dishes at home kitchen

Rocky River is a city where charm meets convenience. With its beautiful lakefront views, tree-lined streets, and close-knit neighborhoods, it’s easy to see why families love living here. But Rocky River homeowners also know the challenges that come with Northeast Ohio’s unpredictable weather. From icy blasts off Lake Erie to humid summer stretches, your home’s systems work hard year-round to keep your family safe and comfortable.

For more than 80 years, Blind & Sons has been a trusted partner for families across Northeast Ohio. In Rocky River, we bring that same dedication with local insight and a promise to always put your family’s comfort and safety first. Whether it’s a furnace that breaks down in the middle of the night, a clogged drain that disrupts your day, or an electrical upgrade to support modern living, call our team today at 330-362-9232 or contact us online to get started. 

Why Rocky River Homeowners Choose Blind & Sons

Rocky River is a vibrant lakefront community, home to spots like Rocky River Park, the marina, and bustling Old Detroit Road where neighbors gather. The city blends historic homes near Lake Erie with modern developments further inland, each with its own comfort demands. From freezing lake-effect winds in winter to humid summers spent at Bradstreet’s Landing, local homeowners know their systems are put to the test. Blind & Sons understands these unique challenges and provides solutions tailored to Rocky River’s housing styles, weather, and lifestyle. 

Need Services?

Industry-Leading Heating Services for Rocky River Homes

When winter winds sweep in off Lake Erie, having a safe and reliable heating system isn’t optional, it’s essential. Blind & Sons provides complete heating services designed to keep Rocky River homes warm, efficient, and safe.

Top-Notch Cooling Services to Beat the Rocky River Heat

Summers in Rocky River can bring both high temperatures and high humidity. A dependable air conditioning system is key to staying comfortable. Blind & Sons offers a full range of cooling services designed to keep your home cool, efficient, and safe.

Indoor Air Quality Solutions for Cleaner, Healthier Homes

The air inside your Rocky River home should support your family’s health. Blind & Sons provides indoor air quality solutions that target pollutants, balance humidity, and improve overall comfort.

Comprehensive Plumbing Services Rocky River Families Can Rely On

Garbage disposal under a sink

Plumbing issues can cause major stress and damage if not addressed quickly. Blind & Sons provides plumbing solutions that focus on safety, efficiency, and long-term reliability.

Need Services?

Modern Electrical Services to Power Rocky River Homes Safely

Reliable power is the backbone of modern living. Blind & Sons offers electrical services that keep your home safe, efficient, and ready for the future.

Schedule Trusted Home Services in Rocky River Today

Your home should be a safe haven in every season. Blind & Sons is here to keep it that way with professional heating, cooling, plumbing, and electrical services designed for Rocky River families. From routine maintenance to emergency repairs, we deliver safe and efficient solutions you can count on.

Call 330-362-9232 today or contact us online to schedule service with Blind & Sons. Discover why generations of Northeast Ohio families—including many right here in Rocky River—continue to trust us for dependable home comfort and peace of mind.

 

Recent Jobs and Reviews in Rocky River, OH

Rocky River, OH at a glance

Blind and Sons has completed 20 jobs in Rocky River, OH between April 2026 and October 2026.

The most recent job was on October 14, 2026.

Blind and Sons has completed 25 jobs in Rocky River, OH in the last 12 months.

Job Locations and Reviews

Performed scheduled preventive maintenance on two air conditioning systems and two gas furnaces (four systems total). On the furnace, verified gas manifold pressure with a digital manometer, inspected the inducer motor assembly, gas valve, and control board for proper operation, and serviced the flame sensor/ignitor components. Inspected return air filters (16x25x1) and confirmed all systems were operating within normal parameters.
Performed scheduled preventive maintenance on two air conditioning systems and two gas furnaces (four systems total). On the furnace, verified gas manifold pressure with a digital manometer, inspected the inducer motor assembly, gas valve, and control board for proper operation, and serviced the flame sensor/ignitor components. Inspected return air filters (16x25x1) and confirmed all systems were operating within normal parameters.
Mario M.
Mario M. Checked in
Performed scheduled preventive maintenance on two air conditioning systems and two gas furnaces (four systems total). On the furnace, verified gas manifold pressure with a digital manometer, inspected the inducer motor assembly, gas valve, and control board for proper operation, and serviced the flame sensor/ignitor components. Inspected return air filters (16x25x1) and confirmed all systems were operating within normal parameters.
Rocky River, OH 44116
Performed comprehensive maintenance on a 98-year-old Monitor Gauge Boiler cast iron heating system. Inspection included verification of pressure gauge operation, assessment of all piping connections and fittings, examination of control components and safety devices, and evaluation of system insulation condition. All accessible components were checked for proper operation, with particular attention paid to the age and condition of this vintage Lord James Plant boiler unit to ensure continued safe operation.
Performed comprehensive maintenance on a 98-year-old Monitor Gauge Boiler cast iron heating system. Inspection included verification of pressure gauge operation, assessment of all piping connections and fittings, examination of control components and safety devices, and evaluation of system insulation condition. All accessible components were checked for proper operation, with particular attention paid to the age and condition of this vintage Lord James Plant boiler unit to ensure continued safe operation.
Chris G.
Chris G. Checked in
Performed comprehensive maintenance on a 98-year-old Monitor Gauge Boiler cast iron heating system. Inspection included verification of pressure gauge operation, assessment of all piping connections and fittings, examination of control components and safety devices, and evaluation of system insulation condition. All accessible components were checked for proper operation, with particular attention paid to the age and condition of this vintage Lord James Plant boiler unit to ensure continued safe operation.
Rocky River, OH 44116
Rocky River, OH - Removed and replaced damaged union and coupler section in PVC pipe system. Customer was advised that they are responsible for winterizing plumbing during cold weather conditions to prevent freeze damage. Documentation photos were taken of the completed repair work.
Craig S.
Craig S. Checked in
Removed and replaced damaged union and coupler section in PVC pipe system. Customer was advised that they are responsible for winterizing plumbing during cold weather conditions to prevent freeze damage. Documentation photos were taken of the completed repair work.
Rocky River, OH 44116
Completed installation of two 90% efficiency furnaces and two air conditioning systems. New outdoor condenser units were positioned on concrete pads with proper clearances from the building structure, electrical disconnects mounted on exterior wall, and refrigerant lines installed. Replaced faulty 25-amp Littelfuse fuses during electrical connections to ensure proper circuit protection for the new equipment. All units tested and operational upon completion.
Completed installation of two 90% efficiency furnaces and two air conditioning systems. New outdoor condenser units were positioned on concrete pads with proper clearances from the building structure, electrical disconnects mounted on exterior wall, and refrigerant lines installed. Replaced faulty 25-amp Littelfuse fuses during electrical connections to ensure proper circuit protection for the new equipment. All units tested and operational upon completion.
Charles A.
Charles A. Checked in
Completed installation of two 90% efficiency furnaces and two air conditioning systems. New outdoor condenser units were positioned on concrete pads with proper clearances from the building structure, electrical disconnects mounted on exterior wall, and refrigerant lines installed. Replaced faulty 25-amp Littelfuse fuses during electrical connections to ensure proper circuit protection for the new equipment. All units tested and operational upon completion.
Rocky River, OH 44116
Performed scheduled maintenance descaling service on tankless water heater unit that had been in operation for approximately two years. Completed full system flush using descaling solution pumped through the heat exchanger to remove mineral buildup and calcium deposits. Connected service hoses to inlet and outlet isolation valves, circulated cleaning solution through the unit for proper dwell time, then flushed system with clean water to restore optimal flow and heating efficiency. Inspected all copper supply lines, brass valve connections, and PVC venting for proper operation and secure mounting. Unit returned to normal operation with improved performance characteristics.
Performed scheduled maintenance descaling service on tankless water heater unit that had been in operation for approximately two years. Completed full system flush using descaling solution pumped through the heat exchanger to remove mineral buildup and calcium deposits. Connected service hoses to inlet and outlet isolation valves, circulated cleaning solution through the unit for proper dwell time, then flushed system with clean water to restore optimal flow and heating efficiency. Inspected all copper supply lines, brass valve connections, and PVC venting for proper operation and secure mounting. Unit returned to normal operation with improved performance characteristics.
Craig S.
Craig S. Checked in
Performed scheduled maintenance descaling service on tankless water heater unit that had been in operation for approximately two years. Completed full system flush using descaling solution pumped through the heat exchanger to remove mineral buildup and calcium deposits. Connected service hoses to inlet and outlet isolation valves, circulated cleaning solution through the unit for proper dwell time, then flushed system with clean water to restore optimal flow and heating efficiency. Inspected all copper supply lines, brass valve connections, and PVC venting for proper operation and secure mounting. Unit returned to normal operation with improved performance characteristics.
Rocky River, OH 44116
Completed MVP cooling maintenance visit on four HVAC systems. Investigated reported intermittent thermostat connectivity issues with smart home application. Performed comprehensive inspection of all system components including gas valve assemblies, electrical connections, wiring harnesses, heat exchangers, and control boards. Verified proper operation of all mechanical and electrical components across all four units. All systems found to be functioning within normal parameters with no immediate service requirements identified.
Completed MVP cooling maintenance visit on four HVAC systems. Investigated reported intermittent thermostat connectivity issues with smart home application. Performed comprehensive inspection of all system components including gas valve assemblies, electrical connections, wiring harnesses, heat exchangers, and control boards. Verified proper operation of all mechanical and electrical components across all four units. All systems found to be functioning within normal parameters with no immediate service requirements identified.
Chris G.
Chris G. Checked in
Completed MVP cooling maintenance visit on four HVAC systems. Investigated reported intermittent thermostat connectivity issues with smart home application. Performed comprehensive inspection of all system components including gas valve assemblies, electrical connections, wiring harnesses, heat exchangers, and control boards. Verified proper operation of all mechanical and electrical components across all four units. All systems found to be functioning within normal parameters with no immediate service requirements identified.
Rocky River, OH 44116
Completed preventative maintenance cooling visit on two residential air conditioning systems. Performed comprehensive inspection of both units, including the original system that came with the property and a newer replacement system. Inspected electrical disconnect boxes, noting aged wiring connections with some corrosion present on terminal blocks and mounting plates. Examined contactor assemblies and electrical components for proper operation. All connections were verified secure, and both systems were found operating within normal parameters for continued seasonal use.
Completed preventative maintenance cooling visit on two residential air conditioning systems. Performed comprehensive inspection of both units, including the original system that came with the property and a newer replacement system. Inspected electrical disconnect boxes, noting aged wiring connections with some corrosion present on terminal blocks and mounting plates. Examined contactor assemblies and electrical components for proper operation. All connections were verified secure, and both systems were found operating within normal parameters for continued seasonal use.
Mario M.
Mario M. Checked in
Completed preventative maintenance cooling visit on two residential air conditioning systems. Performed comprehensive inspection of both units, including the original system that came with the property and a newer replacement system. Inspected electrical disconnect boxes, noting aged wiring connections with some corrosion present on terminal blocks and mounting plates. Examined contactor assemblies and electrical components for proper operation. All connections were verified secure, and both systems were found operating within normal parameters for continued seasonal use.
Rocky River, OH 44116
Responded to service call for 1-year-old Lennox air conditioning system displaying error code 413, indicating a high-pressure switch lockout on the outdoor unit. Upon arrival, diagnosed that the system had shut down due to refrigerant pressure exceeding safe operating limits. Customer had been attempting to reset the system by manually flipping the switch at the condenser unit. Performed system evaluation and reset high-pressure switch to restore normal operation.
Responded to service call for 1-year-old Lennox air conditioning system displaying error code 413, indicating a high-pressure switch lockout on the outdoor unit. Upon arrival, diagnosed that the system had shut down due to refrigerant pressure exceeding safe operating limits. Customer had been attempting to reset the system by manually flipping the switch at the condenser unit. Performed system evaluation and reset high-pressure switch to restore normal operation.
Mario M.
Mario M. Checked in
Responded to service call for 1-year-old Lennox air conditioning system displaying error code 413, indicating a high-pressure switch lockout on the outdoor unit. Upon arrival, diagnosed that the system had shut down due to refrigerant pressure exceeding safe operating limits. Customer had been attempting to reset the system by manually flipping the switch at the condenser unit. Performed system evaluation and reset high-pressure switch to restore normal operation.
Rocky River, OH 44116
Rocky River, OH - Installed dedicated 480V electrical circuit and wiring for ductless mini-split heat pump system. Ran conduit and electrical lines from outdoor condenser unit to building entry point, mounted gray electrical disconnect box on exterior wall per code requirements, and completed all necessary connections to power the HVAC equipment.
Landon M.
Landon M. Checked in
Installed dedicated 480V electrical circuit and wiring for ductless mini-split heat pump system. Ran conduit and electrical lines from outdoor condenser unit to building entry point, mounted gray electrical disconnect box on exterior wall per code requirements, and completed all necessary connections to power the HVAC equipment.
Rocky River, OH 44116
Completed installation of a 2-head ductless mini split system in residential property. Mounted indoor air handler units in two separate bedrooms, with one unit installed above bed area and second unit mounted on wall in adjacent bedroom. Established refrigerant line connections, electrical wiring, and condensate drainage for both zones to provide independent climate control for each room.
Completed installation of a 2-head ductless mini split system in residential property. Mounted indoor air handler units in two separate bedrooms, with one unit installed above bed area and second unit mounted on wall in adjacent bedroom. Established refrigerant line connections, electrical wiring, and condensate drainage for both zones to provide independent climate control for each room.
Deontae G.
Deontae G. Checked in
Completed installation of a 2-head ductless mini split system in residential property. Mounted indoor air handler units in two separate bedrooms, with one unit installed above bed area and second unit mounted on wall in adjacent bedroom. Established refrigerant line connections, electrical wiring, and condensate drainage for both zones to provide independent climate control for each room.
Rocky River, OH 44116
Conducted on-site evaluation for mini split system installation in home addition located beyond practical reach of existing furnace ductwork. Assessed two interior spaces to determine optimal equipment placement and capacity requirements for adequate climate control of the remote living area.
Conducted on-site evaluation for mini split system installation in home addition located beyond practical reach of existing furnace ductwork. Assessed two interior spaces to determine optimal equipment placement and capacity requirements for adequate climate control of the remote living area.
Kevin T.
Kevin T. Checked in
Conducted on-site evaluation for mini split system installation in home addition located beyond practical reach of existing furnace ductwork. Assessed two interior spaces to determine optimal equipment placement and capacity requirements for adequate climate control of the remote living area.
Rocky River, OH 44116
Responded to service call regarding unusual odor from unit following recent maintenance. Performed comprehensive system inspection to verify all components were properly secured and functioning correctly. Measured and recorded temperature differential across evaporator coil at 41.92 degrees, confirming adequate cooling performance and proper refrigerant charge. Checked all electrical connections, verified no components were disturbed during previous service, and confirmed unit operating within normal parameters. System found to be secure and safe for continued operation.
Responded to service call regarding unusual odor from unit following recent maintenance. Performed comprehensive system inspection to verify all components were properly secured and functioning correctly. Measured and recorded temperature differential across evaporator coil at 41.92 degrees, confirming adequate cooling performance and proper refrigerant charge. Checked all electrical connections, verified no components were disturbed during previous service, and confirmed unit operating within normal parameters. System found to be secure and safe for continued operation.
Chris G.
Chris G. Checked in
Responded to service call regarding unusual odor from unit following recent maintenance. Performed comprehensive system inspection to verify all components were properly secured and functioning correctly. Measured and recorded temperature differential across evaporator coil at 41.92 degrees, confirming adequate cooling performance and proper refrigerant charge. Checked all electrical connections, verified no components were disturbed during previous service, and confirmed unit operating within normal parameters. System found to be secure and safe for continued operation.
Rocky River, OH 44116
Completed full HVAC system installation including 90% efficiency furnace, air conditioning unit, and humidifier in residential basement utility room. Installed new furnace with proper venting using white PVC piping configured with multiple elbows for exhaust and intake termination. Connected furnace to existing ductwork and established electrical connections. Mounted and positioned Rheem brand air conditioning condenser unit at exterior location. Integrated humidifier into HVAC system for whole-home humidity control. Verified all PVC venting meets code requirements with proper slope and support. Tested system operation including furnace ignition sequence, blower motor function, and thermostat communication. Confirmed AC refrigerant lines properly connected and system charged to manufacturer specifications. Ensured all safety labels and documentation affixed to equipment. System tested and operational upon completion.
Completed full HVAC system installation including 90% efficiency furnace, air conditioning unit, and humidifier in residential basement utility room. Installed new furnace with proper venting using white PVC piping configured with multiple elbows for exhaust and intake termination. Connected furnace to existing ductwork and established electrical connections. Mounted and positioned Rheem brand air conditioning condenser unit at exterior location. Integrated humidifier into HVAC system for whole-home humidity control. Verified all PVC venting meets code requirements with proper slope and support. Tested system operation including furnace ignition sequence, blower motor function, and thermostat communication. Confirmed AC refrigerant lines properly connected and system charged to manufacturer specifications. Ensured all safety labels and documentation affixed to equipment. System tested and operational upon completion.
Jay E.
Jay E. Checked in
Completed full HVAC system installation including 90% efficiency furnace, air conditioning unit, and humidifier in residential basement utility room. Installed new furnace with proper venting using white PVC piping configured with multiple elbows for exhaust and intake termination. Connected furnace to existing ductwork and established electrical connections. Mounted and positioned Rheem brand air conditioning condenser unit at exterior location. Integrated humidifier into HVAC system for whole-home humidity control. Verified all PVC venting meets code requirements with proper slope and support. Tested system operation including furnace ignition sequence, blower motor function, and thermostat communication. Confirmed AC refrigerant lines properly connected and system charged to manufacturer specifications. Ensured all safety labels and documentation affixed to equipment. System tested and operational upon completion.
Rocky River, OH 44116
Completed MVP recurring cooling maintenance visit on residential air conditioning system. Performed visual inspection of outdoor condenser unit, verified proper placement on concrete pad, checked clearances and surrounding area for debris accumulation. Unit operating within normal parameters with all safety labels intact and accessible for future reference.
Completed MVP recurring cooling maintenance visit on residential air conditioning system. Performed visual inspection of outdoor condenser unit, verified proper placement on concrete pad, checked clearances and surrounding area for debris accumulation. Unit operating within normal parameters with all safety labels intact and accessible for future reference.
John W.
John W. Checked in
Completed MVP recurring cooling maintenance visit on residential air conditioning system. Performed visual inspection of outdoor condenser unit, verified proper placement on concrete pad, checked clearances and surrounding area for debris accumulation. Unit operating within normal parameters with all safety labels intact and accessible for future reference.
Rocky River, OH 44116
Rocky River, OH - Completed routine MVP cooling maintenance visit on outdoor air conditioning condenser unit. Performed standard system inspection and documented current equipment condition, noting significant dirt and debris accumulation on condenser coils and cabinet surfaces requiring attention during service. Unit operational at time of visit with maintenance procedures completed per recurring service protocol.
John W.
John W. Checked in
Completed routine MVP cooling maintenance visit on outdoor air conditioning condenser unit. Performed standard system inspection and documented current equipment condition, noting significant dirt and debris accumulation on condenser coils and cabinet surfaces requiring attention during service. Unit operational at time of visit with maintenance procedures completed per recurring service protocol.
Rocky River, OH 44116
Completed installation of replacement air conditioning unit and coil system located beneath rear deck of Building 1. Unit positioned in screened area behind property, shielded by existing tree line for aesthetic purposes. Verified and replaced FLNR 25A electrical fuses as part of electrical disconnect service, ensuring proper amperage protection for new system startup and operation.
Completed installation of replacement air conditioning unit and coil system located beneath rear deck of Building 1. Unit positioned in screened area behind property, shielded by existing tree line for aesthetic purposes. Verified and replaced FLNR 25A electrical fuses as part of electrical disconnect service, ensuring proper amperage protection for new system startup and operation.
Uriel W.
Uriel W. Checked in
Completed installation of replacement air conditioning unit and coil system located beneath rear deck of Building 1. Unit positioned in screened area behind property, shielded by existing tree line for aesthetic purposes. Verified and replaced FLNR 25A electrical fuses as part of electrical disconnect service, ensuring proper amperage protection for new system startup and operation.
Rocky River, OH 44116
Completed scheduled cooling maintenance inspection. Performed system evaluation including blower assembly examination and electrical component inspection. Blower wheel showed normal dust accumulation; verified proper operation of capacitors, relays, and control board wiring connections. All components functioning within normal parameters at time of service.
Completed scheduled cooling maintenance inspection. Performed system evaluation including blower assembly examination and electrical component inspection. Blower wheel showed normal dust accumulation; verified proper operation of capacitors, relays, and control board wiring connections. All components functioning within normal parameters at time of service.
Chris G.
Chris G. Checked in
Completed scheduled cooling maintenance inspection. Performed system evaluation including blower assembly examination and electrical component inspection. Blower wheel showed normal dust accumulation; verified proper operation of capacitors, relays, and control board wiring connections. All components functioning within normal parameters at time of service.
Rocky River, OH 44116
Rocky River, OH - Responded to partial power outage in 55-year-old residence affecting specific areas of the home. Investigated electrical distribution system and identified circuit issues causing loss of power to affected zones. Performed necessary repairs to restore full electrical service to all areas of the residence.
Matthew H.
Matthew H. Checked in
Responded to partial power outage in 55-year-old residence affecting specific areas of the home. Investigated electrical distribution system and identified circuit issues causing loss of power to affected zones. Performed necessary repairs to restore full electrical service to all areas of the residence.
Rocky River, OH 44116
Completed comprehensive estimate for installation of new Generac standby generator system at residential property. Evaluated existing General Electric load center electrical panel with multiple circuit breakers and assessed side yard installation location between house and garage for optimal generator placement. Coordinated gas line installation requirements and arranged future maintenance program enrollment for ongoing system support.
Completed comprehensive estimate for installation of new Generac standby generator system at residential property. Evaluated existing General Electric load center electrical panel with multiple circuit breakers and assessed side yard installation location between house and garage for optimal generator placement. Coordinated gas line installation requirements and arranged future maintenance program enrollment for ongoing system support.
Dustin J.
Dustin J. Checked in
Completed comprehensive estimate for installation of new Generac standby generator system at residential property. Evaluated existing General Electric load center electrical panel with multiple circuit breakers and assessed side yard installation location between house and garage for optimal generator placement. Coordinated gas line installation requirements and arranged future maintenance program enrollment for ongoing system support.
Rocky River, OH 44116
Completed scheduled BS-MVP cooling maintenance visit on 8-year-old Lennox HVAC system. Performed comprehensive inspection of outdoor condensing unit electrical components, indoor furnace unit, and all associated connections. Verified proper operation of contactors, relays, capacitor, and control wiring; documented equipment condition through photographic records of electrical panel and indoor unit installation.
Completed scheduled BS-MVP cooling maintenance visit on 8-year-old Lennox HVAC system. Performed comprehensive inspection of outdoor condensing unit electrical components, indoor furnace unit, and all associated connections. Verified proper operation of contactors, relays, capacitor, and control wiring; documented equipment condition through photographic records of electrical panel and indoor unit installation.
Mario M.
Mario M. Checked in
Completed scheduled BS-MVP cooling maintenance visit on 8-year-old Lennox HVAC system. Performed comprehensive inspection of outdoor condensing unit electrical components, indoor furnace unit, and all associated connections. Verified proper operation of contactors, relays, capacitor, and control wiring; documented equipment condition through photographic records of electrical panel and indoor unit installation.
Rocky River, OH 44116

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image