Schedule Service

HVAC, Plumbing & Electrical Experts Serving Seville, OH

HVAC System Repair

When Seville, OH, homeowners need dependable HVAC, plumbing, or electrical services, Blind & Sons is the name they trust. Since 1937, we’ve delivered high-quality home comfort solutions across Northeast Ohio, earning a reputation for reliability, professionalism, and friendly service. Whether you’re dealing with an unexpected breakdown or planning a major system upgrade, our experienced team is here to help you stay comfortable and safe.

Call Blind & Sons at (330) 753-7711 or contact us online to schedule expert HVAC, plumbing, or electrical services in Seville today.

Proudly Serving the Seville Community

Seville is more than just a village in Medina County—it’s a close-knit community steeped in small-town charm. Whether you’re taking a stroll through Hubbard Valley Park, enjoying one of Seville’s historic downtown shops, or settling down in one of its quiet neighborhoods, there’s something special about calling this town home. At Blind & Sons, we understand the importance of preserving that sense of comfort in your own space.

From century-old homes that require thoughtful updates to newer builds needing the latest in energy-efficient technology, we provide services customized to fit the needs of Seville residents. Our technicians live and work in the area, so we know the local building codes, common infrastructure concerns, and weather patterns that can affect your systems.

Need Services?

Dependable Electrical Services in Seville

From powering your lights and appliances to running your security system and electric vehicle charger, your home’s electrical system is essential. Our certified electricians in Seville provide a wide range of services to keep everything running safely and efficiently:

We’re committed to helping Seville homeowners power their homes with confidence.

Expert Plumbing Services in Seville, OH

Leaky faucets, clogged drains, or a broken water heater can throw your day off track. Our plumbing team is prepared to fix the problem fast with reliable workmanship and courteous service. Our Seville plumbing services include:

We’re here for all your plumbing needs—big or small, routine or urgent.

Emergency Heating Services in Seville

A gas furnace installed in a residential basement

When winter settles in and the air turns crisp in Seville, there’s nothing more comforting than knowing your home is warm and safe. At Blind & Sons, we understand how unsettling it can be when your heat unexpectedly goes out. That’s why we’re always here to help, offering gentle, dependable emergency heating services in Seville tailored to your needs.

  • Furnace Repairs: Is your system making odd noises, blowing cool air, or not turning on at all? We’ll diagnose and fix the issue quickly.
  • Boiler Services: We repair and maintain traditional boiler systems to ensure radiant heat runs efficiently.
  • Hybrid Heat™ Solutions: For energy-conscious homeowners, our hybrid systems offer efficient comfort using both gas and electric.
  • Emergency Repairs: Heating emergencies don’t wait, and neither do we.

Top-Rated Cooling Services in Seville, OH

Summers in Seville are known for their warm, humid days—perfect for a picnic in Cy Hewit Park, but not so great when your AC breaks down. Our air conditioning services keep your home cool, efficient, and comfortable:

  • AC Repairs: Whether your system is short cycling, leaking refrigerant, or blowing warm air, we’ll get it working again.
  • New AC Installations: Time for an upgrade? We’ll recommend and install a high-efficiency system that fits your needs.
  • AC Replacements: Old unit costing you money? We’ll replace it with one that performs better and saves on energy.
  • Ductless Mini-Splits: Great for zoned cooling or homes without ductwork.
  • Heat Pumps: Efficient all-in-one heating and cooling options ideal for year-round comfort.
  • Emergency AC Services: Our technicians are available for urgent cooling issues.

Indoor Air Quality Services for Seville Homes

Breathing clean air at home is just as important as keeping your space at the right temperature. Our indoor air quality services in Seville are designed to enhance your health and home comfort:

If you’ve noticed more dust, persistent allergies, or musty odors, it may be time for an air quality check.

Need Services?

Why Choose Blind & Sons in Seville?

For over 80 years, Blind & Sons has served families across Northeast Ohio with dedication and care. What makes us different?

  • Locally Rooted: We’re not just contractors—we’re part of the community.
  • Availability: We offer emergency HVAC and plumbing services day or night.
  • Upfront Pricing: No hidden fees, just honest work.
  • Background-Checked, Certified Technicians: Professional, respectful, and fully trained.
  • Maintenance Value Plans (MVP): Enjoy discounts, priority scheduling, and annual tune-ups.
  • Satisfaction Guaranteed: We stand behind everything we do.

Our commitment to quality, safety, and customer satisfaction has made us a trusted name in Seville and beyond.

Book Trusted HVAC, Plumbing & Electrical Services in Seville, OH

Whether you’re experiencing an unexpected breakdown or planning a proactive upgrade, Blind & Sons is your go-to partner for home comfort in Seville. From emergency repairs to routine maintenance, we provide reliable, local service backed by decades of experience.

Call Blind & Sons at (330) 753-7711 or contact us online to schedule your HVAC, plumbing, or electrical services in Seville, OH. Discover why generations of homeowners trust us to care for their homes.

 

Recent Jobs and Reviews in Seville, OH

Job Locations and Reviews

Responded to multiple plumbing concerns at a 31-year-old residential property. Addressed high water pressure issue causing loud squealing noise in pipes by adjusting pressure regulator to manufacturer specifications. Replaced deteriorated drain trap assembly under utility sink with new P-trap and tailpiece components, ensuring proper seal and drainage. Performed mechanical snaking of bathtub drain to remove hair and debris buildup, restoring proper water flow. All fixtures tested and confirmed operational upon completion.
Responded to multiple plumbing concerns at a 31-year-old residential property. Addressed high water pressure issue causing loud squealing noise in pipes by adjusting pressure regulator to manufacturer specifications. Replaced deteriorated drain trap assembly under utility sink with new P-trap and tailpiece components, ensuring proper seal and drainage. Performed mechanical snaking of bathtub drain to remove hair and debris buildup, restoring proper water flow. All fixtures tested and confirmed operational upon completion.
Karl M.
Karl M. Checked in
Responded to multiple plumbing concerns at a 31-year-old residential property. Addressed high water pressure issue causing loud squealing noise in pipes by adjusting pressure regulator to manufacturer specifications. Replaced deteriorated drain trap assembly under utility sink with new P-trap and tailpiece components, ensuring proper seal and drainage. Performed mechanical snaking of bathtub drain to remove hair and debris buildup, restoring proper water flow. All fixtures tested and confirmed operational upon completion.
Seville, OH 44273
Replaced existing sewage pit and sewage pump with new units, connecting new pump to existing discharge line and vent system. Modified lavatory drain configuration for basement bathroom by connecting to sewage pit vent rather than direct pit lid connection, requiring access through drywall and tile in basement bathroom area. Jackhammered concrete near existing sewage pit location to install new storm water crock and connected existing perforated pipe to new discharge line running to existing downspout. Installed new 1/3 HP sump pump in new sump crock with new check valve. Tested all connections and discharge systems to verify proper operation and absence of leaks. Repoured concrete to rough finish over excavated areas. Exterior drainage system now includes visible turquoise PVC piping running through foundation planting bed, connecting to white downspout along house siding for proper storm water management.
Replaced existing sewage pit and sewage pump with new units, connecting new pump to existing discharge line and vent system. Modified lavatory drain configuration for basement bathroom by connecting to sewage pit vent rather than direct pit lid connection, requiring access through drywall and tile in basement bathroom area. Jackhammered concrete near existing sewage pit location to install new storm water crock and connected existing perforated pipe to new discharge line running to existing downspout. Installed new 1/3 HP sump pump in new sump crock with new check valve. Tested all connections and discharge systems to verify proper operation and absence of leaks. Repoured concrete to rough finish over excavated areas. Exterior drainage system now includes visible turquoise PVC piping running through foundation planting bed, connecting to white downspout along house siding for proper storm water management.
Denny J.
Denny J. Checked in
Replaced existing sewage pit and sewage pump with new units, connecting new pump to existing discharge line and vent system. Modified lavatory drain configuration for basement bathroom by connecting to sewage pit vent rather than direct pit lid connection, requiring access through drywall and tile in basement bathroom area. Jackhammered concrete near existing sewage pit location to install new storm water crock and connected existing perforated pipe to new discharge line running to existing downspout. Installed new 1/3 HP sump pump in new sump crock with new check valve. Tested all connections and discharge systems to verify proper operation and absence of leaks. Repoured concrete to rough finish over excavated areas. Exterior drainage system now includes visible turquoise PVC piping running through foundation planting bed, connecting to white downspout along house siding for proper storm water management.
Seville, OH 44273
Completed annual MVP cooling maintenance visit on 1-year-old HVAC system. Removed access panels to inspect control board, electrical connections, and blower motor assembly. Verified all wiring connections secure with proper color-coded routing throughout control section. Inspected transformer, circuit boards, and motor components for proper operation and wear patterns. All components functioning within normal parameters with minimal dust accumulation consistent with system age.
Completed annual MVP cooling maintenance visit on 1-year-old HVAC system. Removed access panels to inspect control board, electrical connections, and blower motor assembly. Verified all wiring connections secure with proper color-coded routing throughout control section. Inspected transformer, circuit boards, and motor components for proper operation and wear patterns. All components functioning within normal parameters with minimal dust accumulation consistent with system age.
Daniel
Daniel Checked in
Completed annual MVP cooling maintenance visit on 1-year-old HVAC system. Removed access panels to inspect control board, electrical connections, and blower motor assembly. Verified all wiring connections secure with proper color-coded routing throughout control section. Inspected transformer, circuit boards, and motor components for proper operation and wear patterns. All components functioning within normal parameters with minimal dust accumulation consistent with system age.
Seville, OH 44273
Completed routine maintenance visit for MVP customer's cooling system. Inspected indoor Lennox furnace unit in basement and outdoor condensing unit, verifying proper installation, venting configuration, and refrigerant line connections. Both units operating within normal parameters with no visible damage or service issues identified at time of inspection.
Completed routine maintenance visit for MVP customer's cooling system. Inspected indoor Lennox furnace unit in basement and outdoor condensing unit, verifying proper installation, venting configuration, and refrigerant line connections. Both units operating within normal parameters with no visible damage or service issues identified at time of inspection.
William S.
William S. Checked in
Completed routine maintenance visit for MVP customer's cooling system. Inspected indoor Lennox furnace unit in basement and outdoor condensing unit, verifying proper installation, venting configuration, and refrigerant line connections. Both units operating within normal parameters with no visible damage or service issues identified at time of inspection.
Seville, OH 44273
Seville, OH - Completed MVP recurring cooling maintenance visit on 4-year-old Lennox system. Performed standard preventive maintenance inspection of air handler and furnace unit, verified proper operation of all components, checked refrigerant levels, inspected ductwork connections, and confirmed system is operating within manufacturer specifications.
William S.
William S. Checked in
Completed MVP recurring cooling maintenance visit on 4-year-old Lennox system. Performed standard preventive maintenance inspection of air handler and furnace unit, verified proper operation of all components, checked refrigerant levels, inspected ductwork connections, and confirmed system is operating within manufacturer specifications.
Seville, OH 44273
Responded to service call for malfunctioning injector pump experiencing sewer and gas odor issues. Inspected utility closet installation containing dual pump system with associated PVC discharge piping, electrical connections, and ventilation components. Documented existing conditions of pump equipment, wiring configuration, and plumbing connections for assessment and customer consideration of maintenance protection plan options.
Responded to service call for malfunctioning injector pump experiencing sewer and gas odor issues. Inspected utility closet installation containing dual pump system with associated PVC discharge piping, electrical connections, and ventilation components. Documented existing conditions of pump equipment, wiring configuration, and plumbing connections for assessment and customer consideration of maintenance protection plan options.
Denny J.
Denny J. Checked in
Responded to service call for malfunctioning injector pump experiencing sewer and gas odor issues. Inspected utility closet installation containing dual pump system with associated PVC discharge piping, electrical connections, and ventilation components. Documented existing conditions of pump equipment, wiring configuration, and plumbing connections for assessment and customer consideration of maintenance protection plan options.
Seville, OH 44273
Completed MVP cooling maintenance visit on 11-year-old Trane heat pump system. Performed comprehensive inspection of outdoor condenser unit and indoor air handler components. Indoor blower wheel assembly showed significant dust and debris accumulation on metal fins, which can reduce airflow efficiency and system performance. Outdoor condenser unit appeared in serviceable condition with normal weathering for exterior equipment. Conducted standard preventive maintenance procedures including system performance evaluation and visual inspection of all accessible components to ensure continued reliable operation throughout the cooling season.
Completed MVP cooling maintenance visit on 11-year-old Trane heat pump system. Performed comprehensive inspection of outdoor condenser unit and indoor air handler components. Indoor blower wheel assembly showed significant dust and debris accumulation on metal fins, which can reduce airflow efficiency and system performance. Outdoor condenser unit appeared in serviceable condition with normal weathering for exterior equipment. Conducted standard preventive maintenance procedures including system performance evaluation and visual inspection of all accessible components to ensure continued reliable operation throughout the cooling season.
Stephanie E.
Stephanie E. Checked in
Completed MVP cooling maintenance visit on 11-year-old Trane heat pump system. Performed comprehensive inspection of outdoor condenser unit and indoor air handler components. Indoor blower wheel assembly showed significant dust and debris accumulation on metal fins, which can reduce airflow efficiency and system performance. Outdoor condenser unit appeared in serviceable condition with normal weathering for exterior equipment. Conducted standard preventive maintenance procedures including system performance evaluation and visual inspection of all accessible components to ensure continued reliable operation throughout the cooling season.
Seville, OH 44273
Removed and disposed of existing deteriorated toilet fixture showing severe staining and discoloration. Installed new American Standard Champion Pro toilet with round bowl and standard height configuration. Replaced existing water supply shut-off valve with new shut-off on the water line to ensure proper function and code compliance. Hauled away old toilet and debris from the premises upon completion.
Removed and disposed of existing deteriorated toilet fixture showing severe staining and discoloration. Installed new American Standard Champion Pro toilet with round bowl and standard height configuration. Replaced existing water supply shut-off valve with new shut-off on the water line to ensure proper function and code compliance. Hauled away old toilet and debris from the premises upon completion.
Mark W.
Mark W. Checked in
Removed and disposed of existing deteriorated toilet fixture showing severe staining and discoloration. Installed new American Standard Champion Pro toilet with round bowl and standard height configuration. Replaced existing water supply shut-off valve with new shut-off on the water line to ensure proper function and code compliance. Hauled away old toilet and debris from the premises upon completion.
Seville, OH 44273
Seville, OH - Responded to service call for reported small gas leak at stove connection. Upon arrival, performed diagnostic inspection and pressure testing of gas line assembly and termination flange connections. Identified leak at stove termination point, confirmed proper gas pressure readings throughout system, and documented findings with photographs of the gas line configuration and pressure gauge readings for customer reference and potential future repair needs.
Karl M.
Karl M. Checked in
Responded to service call for reported small gas leak at stove connection. Upon arrival, performed diagnostic inspection and pressure testing of gas line assembly and termination flange connections. Identified leak at stove termination point, confirmed proper gas pressure readings throughout system, and documented findings with photographs of the gas line configuration and pressure gauge readings for customer reference and potential future repair needs.
Seville, OH 44273
Responded to service call for toilet leaking at base during flushing. Upon arrival, inspected portable commode unit and determined leak was originating from compromised seal between collection bucket and base assembly. Reseated collection bucket, verified proper alignment of gasket, and confirmed leak was resolved through multiple flush tests with no water discharge observed at floor level.
Responded to service call for toilet leaking at base during flushing. Upon arrival, inspected portable commode unit and determined leak was originating from compromised seal between collection bucket and base assembly. Reseated collection bucket, verified proper alignment of gasket, and confirmed leak was resolved through multiple flush tests with no water discharge observed at floor level.
Mark W.
Mark W. Checked in
Responded to service call for toilet leaking at base during flushing. Upon arrival, inspected portable commode unit and determined leak was originating from compromised seal between collection bucket and base assembly. Reseated collection bucket, verified proper alignment of gasket, and confirmed leak was resolved through multiple flush tests with no water discharge observed at floor level.
Seville, OH 44273
Completed HVAC tune-up service including system inspection and filter replacement. Installed new pleated air filters at the air handler unit and verified proper fit and sealing. Inspected outdoor unit components including solenoid valve and electrical connections, confirming all wiring and copper fittings were secure and functioning properly.
Completed HVAC tune-up service including system inspection and filter replacement. Installed new pleated air filters at the air handler unit and verified proper fit and sealing. Inspected outdoor unit components including solenoid valve and electrical connections, confirming all wiring and copper fittings were secure and functioning properly.
Colton D.
Colton D. Checked in
Completed HVAC tune-up service including system inspection and filter replacement. Installed new pleated air filters at the air handler unit and verified proper fit and sealing. Inspected outdoor unit components including solenoid valve and electrical connections, confirming all wiring and copper fittings were secure and functioning properly.
Seville, OH 44273
Performed diagnostic evaluation of existing reverse osmosis filtration system currently connected to refrigerator. Assessed kitchen sink area and plumbing configuration to determine feasibility of extending RO system to include dedicated faucet installation at sink location. Examined under-sink cabinet space, existing water supply lines, and countertop layout to identify optimal routing path for filtered water line. Evaluated current system capacity and pressure requirements to ensure adequate flow rate for dual-point distribution. Provided comprehensive quote for installation of additional feed line from RO system to new sink-mounted dispenser faucet, including necessary fittings, tubing, and mounting hardware.
Performed diagnostic evaluation of existing reverse osmosis filtration system currently connected to refrigerator. Assessed kitchen sink area and plumbing configuration to determine feasibility of extending RO system to include dedicated faucet installation at sink location. Examined under-sink cabinet space, existing water supply lines, and countertop layout to identify optimal routing path for filtered water line. Evaluated current system capacity and pressure requirements to ensure adequate flow rate for dual-point distribution. Provided comprehensive quote for installation of additional feed line from RO system to new sink-mounted dispenser faucet, including necessary fittings, tubing, and mounting hardware.
Craig S.
Craig S. Checked in
Performed diagnostic evaluation of existing reverse osmosis filtration system currently connected to refrigerator. Assessed kitchen sink area and plumbing configuration to determine feasibility of extending RO system to include dedicated faucet installation at sink location. Examined under-sink cabinet space, existing water supply lines, and countertop layout to identify optimal routing path for filtered water line. Evaluated current system capacity and pressure requirements to ensure adequate flow rate for dual-point distribution. Provided comprehensive quote for installation of additional feed line from RO system to new sink-mounted dispenser faucet, including necessary fittings, tubing, and mounting hardware.
Seville, OH 44273
Seville, OH - Responded to no power call for pool equipment. Upon arrival, found pool motor circuit tripping and displaying error code. Inspected electrical panel and pool motor connections, replaced faulty 20-amp breaker that was failing to hold load, verified proper wiring connections at motor and panel, tested system operation, and restored power to pool equipment with motor running properly without tripping.
Matthew H.
Matthew H. Checked in
Responded to no power call for pool equipment. Upon arrival, found pool motor circuit tripping and displaying error code. Inspected electrical panel and pool motor connections, replaced faulty 20-amp breaker that was failing to hold load, verified proper wiring connections at motor and panel, tested system operation, and restored power to pool equipment with motor running properly without tripping.
Seville, OH 44273
# HVAC Maintenance - Cooling

Completed preventive maintenance on 14-year-old air conditioning system. Upon inspection, found significant dust accumulation, cobwebs, and debris throughout electrical compartment and capacitor housing. Electrical connections showed signs of aging with minor wire insulation deterioration and disorganized wiring routing. White deposits and potential corrosion observed on terminal blocks and brass fittings. Cleaned all electrical components, removed debris from compartment, and inspected capacitor functionality. Verified all wire connections were secure at terminal points. System tested and confirmed operational following maintenance procedures.
# HVAC Maintenance - Cooling

Completed preventive maintenance on 14-year-old air conditioning system. Upon inspection, found significant dust accumulation, cobwebs, and debris throughout electrical compartment and capacitor housing. Electrical connections showed signs of aging with minor wire insulation deterioration and disorganized wiring routing. White deposits and potential corrosion observed on terminal blocks and brass fittings. Cleaned all electrical components, removed debris from compartment, and inspected capacitor functionality. Verified all wire connections were secure at terminal points. System tested and confirmed operational following maintenance procedures.
Hershel M.
Hershel M. Checked in
# HVAC Maintenance - Cooling Completed preventive maintenance on 14-year-old air conditioning system. Upon inspection, found significant dust accumulation, cobwebs, and debris throughout electrical compartment and capacitor housing. Electrical connections showed signs of aging with minor wire insulation deterioration and disorganized wiring routing. White deposits and potential corrosion observed on terminal blocks and brass fittings. Cleaned all electrical components, removed debris from compartment, and inspected capacitor functionality. Verified all wire connections were secure at terminal points. System tested and confirmed operational following maintenance procedures.
Seville, OH 44273
Responded to emergency call for salt tank leaking and flooding basement. Upon arrival, inspected AIO water treatment system including stainless steel filtration tank, brine tank with compromised seal, and associated plumbing connections. Identified leak source at brine tank valve assembly, performed necessary repairs to stop active flooding, and verified all system components including pressure tank, multi-stage filtration housings, and expansion tank were functioning properly with no additional leaks present.
Responded to emergency call for salt tank leaking and flooding basement. Upon arrival, inspected AIO water treatment system including stainless steel filtration tank, brine tank with compromised seal, and associated plumbing connections. Identified leak source at brine tank valve assembly, performed necessary repairs to stop active flooding, and verified all system components including pressure tank, multi-stage filtration housings, and expansion tank were functioning properly with no additional leaks present.
Travis B.
Travis B. Checked in
Responded to emergency call for salt tank leaking and flooding basement. Upon arrival, inspected AIO water treatment system including stainless steel filtration tank, brine tank with compromised seal, and associated plumbing connections. Identified leak source at brine tank valve assembly, performed necessary repairs to stop active flooding, and verified all system components including pressure tank, multi-stage filtration housings, and expansion tank were functioning properly with no additional leaks present.
Seville, OH 44273
Performed scheduled maintenance on a Generac Guardian Series 14-17kW standby generator. Conducted comprehensive inspection of the unit, verified proper operation of the control panel and digital display system, and documented equipment condition through photographic records. Generator found to be in good working order with all systems functioning normally.
Performed scheduled maintenance on a Generac Guardian Series 14-17kW standby generator. Conducted comprehensive inspection of the unit, verified proper operation of the control panel and digital display system, and documented equipment condition through photographic records. Generator found to be in good working order with all systems functioning normally.
Matthew H.
Matthew H. Checked in
Performed scheduled maintenance on a Generac Guardian Series 14-17kW standby generator. Conducted comprehensive inspection of the unit, verified proper operation of the control panel and digital display system, and documented equipment condition through photographic records. Generator found to be in good working order with all systems functioning normally.
Seville, OH 44273
Completed seasonal tune-up on outdoor condensing unit, including capacitor inspection, electrical connection verification, and debris removal from equipment area. Unit tested and operating within normal parameters; all components functioning properly with no deficiencies noted.
Completed seasonal tune-up on outdoor condensing unit, including capacitor inspection, electrical connection verification, and debris removal from equipment area. Unit tested and operating within normal parameters; all components functioning properly with no deficiencies noted.
Jibreel H.
Jibreel H. Checked in
Completed seasonal tune-up on outdoor condensing unit, including capacitor inspection, electrical connection verification, and debris removal from equipment area. Unit tested and operating within normal parameters; all components functioning properly with no deficiencies noted.
Seville, OH 44273
Completed installation of new Trane XE 900 air conditioning condenser unit and evaporator coil system at residential property. The outdoor condenser was positioned against the exterior foundation with proper clearances, connected to the indoor evaporator coil mounted above the existing furnace unit via refrigerant line set with black insulation. All ductwork connections were secured to the existing galvanized metal duct system, electrical connections completed, and system tested for proper operation and refrigerant charge.
Completed installation of new Trane XE 900 air conditioning condenser unit and evaporator coil system at residential property. The outdoor condenser was positioned against the exterior foundation with proper clearances, connected to the indoor evaporator coil mounted above the existing furnace unit via refrigerant line set with black insulation. All ductwork connections were secured to the existing galvanized metal duct system, electrical connections completed, and system tested for proper operation and refrigerant charge.
Jay E.
Jay E. Checked in
Completed installation of new Trane XE 900 air conditioning condenser unit and evaporator coil system at residential property. The outdoor condenser was positioned against the exterior foundation with proper clearances, connected to the indoor evaporator coil mounted above the existing furnace unit via refrigerant line set with black insulation. All ductwork connections were secured to the existing galvanized metal duct system, electrical connections completed, and system tested for proper operation and refrigerant charge.
Seville, OH 44273
Completed on-site evaluation for HVAC system replacement on a 37-year-old unit located in basement mechanical room. Assessed existing equipment configuration including condensate management, ductwork routing through floor joists, and electrical service connections. Documented current system installation including water heater proximity, concrete pad foundation condition, and available clearances for new equipment installation. Provided comprehensive replacement quote covering new system specifications and installation requirements.
Completed on-site evaluation for HVAC system replacement on a 37-year-old unit located in basement mechanical room. Assessed existing equipment configuration including condensate management, ductwork routing through floor joists, and electrical service connections. Documented current system installation including water heater proximity, concrete pad foundation condition, and available clearances for new equipment installation. Provided comprehensive replacement quote covering new system specifications and installation requirements.
Jim F.
Jim F. Checked in
Completed on-site evaluation for HVAC system replacement on a 37-year-old unit located in basement mechanical room. Assessed existing equipment configuration including condensate management, ductwork routing through floor joists, and electrical service connections. Documented current system installation including water heater proximity, concrete pad foundation condition, and available clearances for new equipment installation. Provided comprehensive replacement quote covering new system specifications and installation requirements.
Seville, OH 44273
Responded to no-cooling complaint on approximately 40-year-old Trane XE 900 air conditioning system. Upon arrival, performed visual inspection of outdoor condensing unit, which exhibited significant age-related deterioration including extensive rust, corrosion, and weathering on cabinet panels. Connected manifold gauge set to service ports to assess refrigerant pressures and system operation. Due to advanced age of equipment and observed condition, recommended system replacement rather than repair, as unit has far exceeded typical service life expectancy and replacement parts are no longer readily available for this vintage model.
Responded to no-cooling complaint on approximately 40-year-old Trane XE 900 air conditioning system. Upon arrival, performed visual inspection of outdoor condensing unit, which exhibited significant age-related deterioration including extensive rust, corrosion, and weathering on cabinet panels. Connected manifold gauge set to service ports to assess refrigerant pressures and system operation. Due to advanced age of equipment and observed condition, recommended system replacement rather than repair, as unit has far exceeded typical service life expectancy and replacement parts are no longer readily available for this vintage model.
Jibreel H.
Jibreel H. Checked in
Responded to no-cooling complaint on approximately 40-year-old Trane XE 900 air conditioning system. Upon arrival, performed visual inspection of outdoor condensing unit, which exhibited significant age-related deterioration including extensive rust, corrosion, and weathering on cabinet panels. Connected manifold gauge set to service ports to assess refrigerant pressures and system operation. Due to advanced age of equipment and observed condition, recommended system replacement rather than repair, as unit has far exceeded typical service life expectancy and replacement parts are no longer readily available for this vintage model.
Seville, OH 44273

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image