When you need the best home services in Cuyahoga Falls, trust the team at Blind & Sons. With over 80 years in business, our team of experts offers comprehensive HVAC, plumbing, and electrical services to ensure your home is functional and comfortable.
Our highly trained technicians are the best in the industry, and we stand behind our work with unmatched warranties and guarantees. That’s why we’re known to meet your needs and exceed your expectations!
Schedule HVAC, plumbing, or electrical services today by calling Blind & Sons at (330) 753-7711!

Same-Day Cooling Services
Stay comfortable during the muggy season with our superior cooling services. We’re proud to offer installation, replacement, repair, and maintenance on various systems, including central air, heat pumps, and ductless mini-splits. With our extensive experience, we can handle it all, and with our available emergency AC repair, we’re there for you when you need us most!
Need Services?
We Can Help!
Reliable Heating Services
Winters in Cuyahoga Falls can be bitterly cold and snowy. Stay warm and comfortable on even the coldest day of the year with our unmatched heating services. From installation and maintenance to repair and replacement, our skilled technicians have the tools and training to provide outstanding service for various system types, including furnaces, boilers, and Hybrid Heat. Are you stuck without heat due to a breakdown? Trust our emergency heating repair service to restore your system quickly!
Stay warm all winter by scheduling a heating service with Blind & Sons at (330) 753-7711!
Air Quality Services in Cuyahoga Falls
Enjoy your time inside with indoor air quality services from Blind & Sons. Our solutions can help improve your comfort & health with services and products, including:
- Air cleaners & purifiers
- Air scrubbers
- Whole-house humidifiers & dehumidifiers
- UV lamp air purification
- Duct cleanings
To schedule indoor air quality services, call (330) 753-7711 today!
Dependable Electrical Services
For safe and reliable electrical services, trust the licensed electricians at Blind & Sons. Our comprehensive electrical services include general installation, replacement, repair, electrical panel services, and rewiring. We also offer specialized services, including electrical inspections, whole-home generators, EV chargers, and more!
Call Blind & Sons today at (330) 753-7711 to schedule your next electrical service with our team!
Top-Rated Plumbing Services
Keep your plumbing system operating at peak performance with plumbing services from Blind & Sons. Our expert plumbers are here to handle even the most complex repairs to help protect your home from water damage and ensure that you have the reliable plumbing you need.
We also provide comprehensive water heater services for standard and tankless systems to ensure you can access the hot water you need. Plus, with drain cleaning services, we’ll remove stubborn clogs to ensure your pipes can flow freely!
Trust the plumbers at Blind & Sons! Call (330) 753-7711 today to schedule service!
Choose Blind & Sons in Cuyahoga Falls
Since 1937, Blind & Sons has provided outstanding HVAC, plumbing, and electrical service to the residents of Cuyahoga Falls and Northeast Ohio. We’re proud to offer emergency heating and cooling services to ensure our customers’ comfort is never compromised. Plus, with our satisfaction guarantee, you can trust you’re only getting the best possible service from our team!
Call (330) 753-7711 today to schedule HVAC, plumbing, or electrical services for your Cuyahoga Falls home!
Recent Jobs and Reviews in Cuyahoga Falls, OH
Job Locations and Reviews
Conducted site evaluation for outdoor water spigot replacement and provided quote for frost-free hose bib installation. Assessed existing gray spigot mounted on vinyl siding with connected garden hoses and inspected corresponding interior plumbing connections in basement crawl space. Documented current configuration through exterior and interior photography to support installation proposal for upgraded frost-free spigot system.
Performed comprehensive cooling maintenance on a five-year-old air conditioning system. Conducted complete system diagnostics using clamp meter to verify electrical performance and amperage draws on the outdoor condensing unit. Inspected all electrical connections, wiring, and capacitor within the outdoor unit's electrical panel. Verified proper operation of all components, checked refrigerant pressures, and ensured system is operating within manufacturer specifications for the upcoming cooling season.
Repaired refrigerator ice maker water supply line in attic space. Accessed existing copper tubing routed through ceiling joists near HVAC ductwork, replaced damaged section with new supply line, and secured connections to prevent future leaks. System tested and confirmed operational with proper water flow to ice maker unit.
Completed preventive maintenance visit on Bryant HVAC system for MVP customer. Performed inspection of blower wheel assembly, which showed dust accumulation on central hub but otherwise clean blade surfaces, and verified proper operation of furnace and air handler components in basement mechanical room.
Replaced leaking outdoor spigot with new fixture and installed shut-off valves on copper supply lines mounted to interior wall access panel. Tested system for proper operation and verified no leaks at connections.
Responded to outdoor spigot failure caused by freeze damage. Located and shut off water supply at basement shutoff valve. Removed damaged frost-free sillcock that exhibited cracked body and compromised internal components causing omnidirectional water spray. Installed new frost-free outdoor spigot with proper pitch for drainage, secured mounting bracket to exterior wall, and soldered copper connections at supply line. Tested operation under full pressure to verify proper function and confirmed no leaks at connections or valve body.
Responded to emergency service call for broken copper water line in kitchen ceiling. Upon arrival, confirmed copper pipe failure within ceiling cavity requiring immediate repair. Shut off water supply to affected area to prevent further water damage. Accessed damaged section through existing ceiling opening. Cut out failed copper line section and installed new copper piping using proper soldering techniques and fittings. Pressure tested repair to ensure no leaks. Verified water flow restoration to kitchen fixtures. Left ceiling access open as requested for customer's contractor to complete drywall repairs.
Completed scheduled MVP cooling maintenance visit on 5-year-old air conditioning system. Performed comprehensive inspection of HVAC unit including examination of control board, electrical connections, and wiring configuration within furnace compartment. Verified proper termination of all electrical components and connections to control board. Inspected air filtration system and documented filter condition showing moderate dust accumulation consistent with normal operation. All electrical components, terminal blocks, and wiring connections found secure and functioning within normal parameters.
Completed MVP cooling maintenance visit on 5-year-old system. Performed comprehensive inspection of furnace/air handler unit, ductwork connections, and associated HVAC components in mechanical room. Verified electrical disconnect box operation and connection integrity, inspecting all wire terminals and circuit breaker mechanism for proper function and safety compliance. Documented equipment condition with photographs showing all major system components, including metallic supply and return ductwork, humidification equipment, and copper refrigerant lines. All equipment operating within normal parameters with no immediate service needs identified.
Completed MVP cooling maintenance visit on 16-year-old HVAC system. Inspected blower wheel assembly and evaporator coil, documenting normal dust accumulation on blower blades and dark discoloration with debris buildup on evaporator fins. Unit operational with age-appropriate wear patterns observed throughout components.
Responded to non-functional doorbell system that had been inoperative for several years. Upon inspection, discovered loose connection between romex and transformer, which was secured. After reconnection, chime produced buzzing noise due to damaged wire insulation at front door button with insufficient wire length for repair. Ran new 18/2 thermostat wire from transformer junction box to exterior, routing along siding to front door button. Utilized existing multi-conductor wire in basement to connect new feed to chime, eliminating need for complete rewire of that section.
Completed installation of new air conditioning system and evaporator coil in residential basement mechanical room. Unit was properly positioned, connected to existing ductwork, and all condensate drainage lines were installed with PVC piping to ensure proper system operation and efficiency.
Completed annual tune-up on 29-year-old air conditioning system. Discovered and removed significant animal nesting material from electrical compartment of outdoor condensing unit, which posed serious fire hazard and could have prevented proper system operation. Inspected electrical connections, contactor, and wiring for damage; noted corrosion on contactor terminals requiring monitoring for future replacement.
Responded to service call for cracked ground wire in supply line near exterior walkway affecting wiring before entry point to home. Inspected exterior supply line and identified compromised insulation on ground conductor requiring attention. Assessed electrical panel and associated breaker connections to ensure no secondary issues from deteriorated exterior wiring. Documented panel condition and exterior wire damage with photographs for service records.
Responded to no-cooling call on recently installed residential AC unit. Upon arrival, found unit attempting to start but failing to run. Removed service panel and performed electrical diagnostics on condensing unit. Measured voltage at capacitor terminals using digital multimeter, which indicated insufficient capacitance at 4.63 microfarads. Identified failed run capacitor as root cause preventing compressor from starting. Replaced defective capacitor with proper OEM replacement, verified correct voltage and amperage readings, and successfully tested unit operation. System now cooling properly with normal startup and run cycle.
Completed installation of new outdoor air conditioning condenser unit on concrete pad with proper electrical disconnect and refrigerant line routing secured to exterior siding. Installed new evaporator coil system in basement mechanical room alongside existing water heater, including all necessary refrigerant connections, condensate drainage, and electrical controls. All components tested and verified operational upon completion.
Responded to emergency call for burst cold water line supplying outdoor spigot. Upon arrival, found homeowner had shut off main water supply to stop active flooding. Accessed affected piping in basement/crawlspace area where copper supply line had failed. Assessed damage to water line and surrounding infrastructure, including proximity to HVAC ductwork and ceiling joists. Documented existing plumbing configuration showing multiple copper lines, insulated piping, and connection points. Evaluated extent of water damage to ceiling materials and structural components. Provided diagnostic assessment of failed pipe section and recommended repair options to restore water service to the property.
Completed installation of Lennox ML14KC1-030-230A03 air conditioning unit with matching evaporator coil as part of second-phase HVAC system installation. Unit manufactured September 2025, factory-charged with R-410A refrigerant at 540 PSIG for 50-foot line set. Installed 25-amp Littelfuse fuses in outdoor disconnect for proper electrical protection. Verified all electrical connections meet manufacturer specifications for 208/230V, single-phase, 60Hz operation. System commissioned and operational.
Completed full HVAC system installation including 80% efficiency furnace and air conditioning unit. Installed outdoor AC condenser on pad beside residence with refrigerant lines and electrical conduit properly secured to exterior siding, and positioned indoor furnace unit in mechanical room with all necessary plumbing connections, ductwork, and venting completed per manufacturer specifications.
Responded to multiple plumbing concerns including a basement shower leak, reduced water pressure, and refrigerator water line leak. Inspected jetted bathtub fixtures and aging tub spout/shower diverter valve showing significant oxidation and wear. Examined basement plumbing infrastructure, including PVC P-trap drain assembly beneath floor joists serving upper level fixtures. Assessed drain system connections and mounting hardware for proper installation and potential leak sources. Documented condition of plumbing components and fixtures to address reported water leak issues and pressure concerns.