When you need the best home services in Cuyahoga Falls, trust the team at Blind & Sons. With over 80 years in business, our team of experts offers comprehensive HVAC, plumbing, and electrical services to ensure your home is functional and comfortable.
Our highly trained technicians are the best in the industry, and we stand behind our work with unmatched warranties and guarantees. That’s why we’re known to meet your needs and exceed your expectations!
Schedule HVAC, plumbing, or electrical services today by calling Blind & Sons at 330-362-9232!

Same-Day Cooling Services
Stay comfortable during the muggy season with our superior cooling services. We’re proud to offer installation, replacement, repair, and maintenance on various systems, including central air, heat pumps, and ductless mini-splits. With our extensive experience, we can handle it all, and with our available emergency AC repair, we’re there for you when you need us most!
Need Services?
We Can Help!
Reliable Heating Services
Winters in Cuyahoga Falls can be bitterly cold and snowy. Stay warm and comfortable on even the coldest day of the year with our unmatched heating services. From installation and maintenance to repair and replacement, our skilled technicians have the tools and training to provide outstanding service for various system types, including furnaces, boilers, and Hybrid Heat. Are you stuck without heat due to a breakdown? Trust our emergency heating repair service to restore your system quickly!
Stay warm all winter by scheduling a heating service with Blind & Sons at 330-362-9232!
Air Quality Services in Cuyahoga Falls
Enjoy your time inside with indoor air quality services from Blind & Sons. Our solutions can help improve your comfort & health with services and products, including:
- Air cleaners & purifiers
- Air scrubbers
- Whole-house humidifiers & dehumidifiers
- UV lamp air purification
- Duct cleanings
To schedule indoor air quality services, call 330-362-9232 today!
Dependable Electrical Services
For safe and reliable electrical services, trust the licensed electricians at Blind & Sons. Our comprehensive electrical services include general installation, replacement, repair, electrical panel services, and rewiring. We also offer specialized services, including electrical inspections, whole-home generators, EV chargers, and more!
Call Blind & Sons today at 330-362-9232 to schedule your next electrical service with our team!
Top-Rated Plumbing Services
Keep your plumbing system operating at peak performance with plumbing services from Blind & Sons. Our expert plumbers are here to handle even the most complex repairs to help protect your home from water damage and ensure that you have the reliable plumbing you need.
We also provide comprehensive water heater services for standard and tankless systems to ensure you can access the hot water you need. Plus, with drain cleaning services, we’ll remove stubborn clogs to ensure your pipes can flow freely!
Trust the plumbers at Blind & Sons! Call 330-362-9232 today to schedule service!
Choose Blind & Sons in Cuyahoga Falls
Since 1937, Blind & Sons has provided outstanding HVAC, plumbing, and electrical service to the residents of Cuyahoga Falls and Northeast Ohio. We’re proud to offer emergency heating and cooling services to ensure our customers’ comfort is never compromised. Plus, with our satisfaction guarantee, you can trust you’re only getting the best possible service from our team!
Call 330-362-9232 today to schedule HVAC, plumbing, or electrical services for your Cuyahoga Falls home!
Blind and Sons has completed 20 jobs in Cuyahoga Falls, OH in May 2026. The most recent job was on May 15, 2026. Blind and Sons has completed 1,014 jobs in Cuyahoga Falls, OH in the last 12 months.Recent Jobs and Reviews in Cuyahoga Falls, OH
Cuyahoga Falls, OH at a glance
Job Locations and Reviews
Responded to no cooling complaint on 14-year-old rooftop air conditioning unit. Accessed unit via ladder and crawlspace. Upon inspection, found failed motor-run capacitor preventing compressor operation. Removed access panel and inspected electrical components. Replaced defective Amrad Turbo 200 capacitor with new unit, reconnected all electrical terminals, and verified proper wire connections. Tested system operation and confirmed compressor startup and normal cooling function restored. Secured access panel and left unit operational.
Completed routine MVP cooling maintenance visit on HVAC system. Performed electrical diagnostics using clamp meter to verify proper amperage draws and system performance. Inspected and documented electrical connections, contactors, and terminal blocks, noting all components operating within normal parameters for continued reliable cooling operation.
Replaced faulty thermal expansion valve (TXV) and line drier on HVAC system. Evacuated refrigerant, removed old components, installed new brass TXV and drier, then recharged system to manufacturer specifications. System tested and confirmed operating properly with correct superheat and subcooling temperatures.
Provided comprehensive estimate for replacement of 23-year-old gas furnace and air conditioning system with confirmed refrigerant leak in existing AC unit. Assessment included evaluation of current Carrier furnace installation, inspection of ductwork showing significant condensation issues, and discussion of additional equipment options including humidifier and salt-free water softening system to address customer's specific requirements.
Responded to warranty call for newly installed air conditioning system producing abnormal loud noise upon startup. Performed comprehensive inspection of Lennox HVAC system including furnace, air handler, and associated components. Verified proper installation of intake and exhaust venting, gas line connections, and electrical wiring. Inspected AprilAire humidifier and ductwork connections for secure mounting and potential vibration sources. Documented system configuration with photographs showing complete installation layout. System evaluated for loose panels, unsecured components, or improper mounting that could cause operational noise during AC startup cycle.
Completed MVP cooling maintenance visit on Lennox HVAC system. Performed comprehensive inspection of furnace unit, verified proper operation of all components, checked electrical connections at exterior service panel, and documented system condition with photographs. All equipment found operating within normal parameters.
Completed routine cooling maintenance visit on 3-year-old residential HVAC system as part of recurring MVP service plan. Performed comprehensive inspection of indoor furnace/air handler unit with Aprilaire humidifier in basement mechanical room and outdoor condensing unit. Verified proper operation of all system components, checked refrigerant lines, inspected condensate pump and drainage system, and confirmed adequate airflow through both indoor and outdoor equipment. System operating within normal parameters with no deficiencies noted.
Replaced second floor tub shower faucet with new Moen Eva trim assembly, including installation of new shut-off valves accessed through wall panel. Removed existing waste and overflow assembly and installed new lift and turn style drain system. All copper supply lines and brass compression fittings properly secured, tested system for leaks, and verified proper operation of all components.
Completed scheduled water softener maintenance checkup on IMPRESSION Plus water-right brand system. Inspected system operation and digital control panel displaying total gallons processed at 188,491. Replenished salt supply from warehouse inventory to maintain proper brine levels for continued ion exchange functionality. Verified system settings and regeneration cycle programming. All equipment operating within normal parameters.
Repaired two dripping exterior hose bibs and replaced a faulty shut-off valve located at the back corner of the residence. The shut-off valve replacement was performed in the attic/ceiling space where the copper supply line was accessed, requiring work among the wooden framing and insulation. All exterior faucets were tested for proper operation and leaks were eliminated upon completion.
Conducted on-site evaluation of existing electrical panel and breaker box for potential upgrade. Inspected aged residential panel installation showing worn wiring connections, documented current panel configuration with dual-column circuit breaker arrangement, and assessed condition of main disconnect. Provided comprehensive estimate for panel replacement to meet current electrical code requirements and improve system safety.
Conducted comprehensive on-site evaluation for complete HVAC system replacement at residential property. Assessed existing Goodman furnace unit located in basement utility area and outdoor air conditioning condenser unit positioned in side yard service area. Documented current equipment conditions, installation configurations, ductwork connections, electrical service routing, and clearance requirements. Provided detailed replacement estimate including equipment specifications and installation scope for new heating and cooling system.
Completed comprehensive tune-up on 9-year-old air conditioning system. Inspected electrical components including dual run capacitor and associated wiring connections, verified proper wire terminations and mounting hardware integrity. Evaluated outdoor condensing unit installation, checked refrigerant line insulation condition, and confirmed disconnect box operation and exterior mounting security.
Performed routine descaling maintenance on a 2-year-old Energy Star-rated tankless water heater unit. Flushed system with descaling solution to remove mineral buildup and ensure optimal heat exchanger performance and efficiency.
Performed scheduled preventive maintenance on residential Generac standby generator unit. Conducted comprehensive system diagnostics using digital testing equipment to verify battery voltage and overall electrical system health. Battery load test confirmed optimal performance with readings within manufacturer specifications. Inspected all exterior components including control panel, indicator lights, and ventilation louvers for proper operation. Verified unit status indicator showing normal standby mode. All systems tested and confirmed operational, ready for automatic transfer during utility power interruption.
Completed preventive maintenance tune-up on 6-year-old Lennox 13ACX air conditioning system. Performed standard maintenance procedures including inspection of condenser unit, verification of proper operation, and assessment of overall system condition. Evaluated ductwork and discussed membership program renewal with property owner.
Performed annual preventive maintenance on one-year-old air conditioning system. Conducted comprehensive inspection of control board, electrical connections, evaporator coil assembly, and refrigerant lines. All components found to be operating within normal parameters with proper connections and no visible defects noted.
# HVAC Maintenance Report
Completed scheduled cooling system maintenance visit on a 3-year-old air conditioning unit. Upon inspection, discovered evaporator coil completely covered in heavy frost and ice buildup, indicating restricted airflow or potential refrigerant issues. Documented system condition with photographs showing the air handler installation in basement utility area and the frozen evaporator coil assembly with extensive ice accumulation across aluminum fins and copper refrigerant lines. The frost buildup was uniform and severe, covering the entire coil surface and surrounding components, which would significantly reduce system efficiency and cooling capacity if left unaddressed.
Identified the ice formation as a critical issue requiring immediate attention, as this condition typically results from reduced airflow due to dirty filters, blocked return air, blower motor problems, or low refrigerant charge. The system components including ductwork, condensate drains, and re
Completed annual air conditioning tune-up on 5-6 year old system. Performed comprehensive inspection of indoor air handler unit, checked all electrical connections and wiring terminals, verified proper operation of mechanical components, and inspected condensate drainage system. All components found operating within normal parameters with no issues identified requiring immediate attention.
Completed MVP cooling maintenance visit on 12-year-old system. Replaced dirty air filter with new unit, as evidenced by significant dust accumulation on the old filter. Inspected condensate drain system and found standing water with debris and sediment accumulation in drain pan, indicating potential drainage issue that will require monitoring or future attention to prevent overflow and water damage.