When you need the best home services in Cuyahoga Falls, trust the team at Blind & Sons. With over 80 years in business, our team of experts offers comprehensive HVAC, plumbing, and electrical services to ensure your home is functional and comfortable.
Our highly trained technicians are the best in the industry, and we stand behind our work with unmatched warranties and guarantees. That’s why we’re known to meet your needs and exceed your expectations!
Schedule HVAC, plumbing, or electrical services today by calling Blind & Sons at 330-362-9232!

Same-Day Cooling Services
Stay comfortable during the muggy season with our superior cooling services. We’re proud to offer installation, replacement, repair, and maintenance on various systems, including central air, heat pumps, and ductless mini-splits. With our extensive experience, we can handle it all, and with our available emergency AC repair, we’re there for you when you need us most!
Need Services?
We Can Help!
Reliable Heating Services
Winters in Cuyahoga Falls can be bitterly cold and snowy. Stay warm and comfortable on even the coldest day of the year with our unmatched heating services. From installation and maintenance to repair and replacement, our skilled technicians have the tools and training to provide outstanding service for various system types, including furnaces, boilers, and Hybrid Heat. Are you stuck without heat due to a breakdown? Trust our emergency heating repair service to restore your system quickly!
Stay warm all winter by scheduling a heating service with Blind & Sons at 330-362-9232!
Air Quality Services in Cuyahoga Falls
Enjoy your time inside with indoor air quality services from Blind & Sons. Our solutions can help improve your comfort & health with services and products, including:
- Air cleaners & purifiers
- Air scrubbers
- Whole-house humidifiers & dehumidifiers
- UV lamp air purification
- Duct cleanings
To schedule indoor air quality services, call 330-362-9232 today!
Dependable Electrical Services
For safe and reliable electrical services, trust the licensed electricians at Blind & Sons. Our comprehensive electrical services include general installation, replacement, repair, electrical panel services, and rewiring. We also offer specialized services, including electrical inspections, whole-home generators, EV chargers, and more!
Call Blind & Sons today at 330-362-9232 to schedule your next electrical service with our team!
Top-Rated Plumbing Services
Keep your plumbing system operating at peak performance with plumbing services from Blind & Sons. Our expert plumbers are here to handle even the most complex repairs to help protect your home from water damage and ensure that you have the reliable plumbing you need.
We also provide comprehensive water heater services for standard and tankless systems to ensure you can access the hot water you need. Plus, with drain cleaning services, we’ll remove stubborn clogs to ensure your pipes can flow freely!
Trust the plumbers at Blind & Sons! Call 330-362-9232 today to schedule service!
Choose Blind & Sons in Cuyahoga Falls
Since 1937, Blind & Sons has provided outstanding HVAC, plumbing, and electrical service to the residents of Cuyahoga Falls and Northeast Ohio. We’re proud to offer emergency heating and cooling services to ensure our customers’ comfort is never compromised. Plus, with our satisfaction guarantee, you can trust you’re only getting the best possible service from our team!
Call 330-362-9232 today to schedule HVAC, plumbing, or electrical services for your Cuyahoga Falls home!
Blind and Sons has completed 20 jobs in Cuyahoga Falls, OH in October 2026. The most recent job was on October 14, 2026. Blind and Sons has completed 1,010 jobs in Cuyahoga Falls, OH in the last 12 months.Recent Jobs and Reviews in Cuyahoga Falls, OH
Cuyahoga Falls, OH at a glance
Job Locations and Reviews
Performed scheduled maintenance on a 6-year-old high-efficiency condensing gas furnace, including inspection of PVC venting, condensate drain lines, and electrical connections. Conducted combustion analysis with a Bacharach analyzer on natural gas, recording stack temperature of 104°F, excess air of 33.4%, and CO of 36 ppm, with no frost, ice, or visible rust observed on the equipment.
Removed the existing basement toilet and installed a new chair-height toilet, including a new wax seal, closet bolts, and supply connection. Verified the drain connection and ABS piping, secured the fixture level to the floor flange, and tested for proper flushing and leaks.
Performed a seasonal tune-up on a Lennox EL296UH070XV36B high-efficiency gas furnace, inspecting the control board, wiring connections, and blower compartment, and finding all components intact with no signs of rust, frost, or damage. Cleared heavy accumulations of dust, lint, and debris from the plenum and blower areas to restore proper airflow and system efficiency.
Completed comprehensive duct cleaning service for 15 vents throughout the residence. All supply and return vents were thoroughly cleaned and sanitized, with particular attention paid to the attic and crawl space areas where significant dust accumulation was present. HVAC return grille was properly resealed with foil tape to ensure airtight connection and prevent air leakage, improving system efficiency.
Performed scheduled maintenance on a 14kW residential standby generator, approximately two years old. Conducted comprehensive system inspection, verified proper operation of all components, and performed battery load testing using diagnostic equipment which confirmed 100% state of health and state of charge with passing results. Unit operating within normal parameters with status indicators showing proper function.
Installed a new 50-gallon Bradford White water heater with a 10-year manufacturer warranty in the basement utility area. Installation included a new ball valve, thermal expansion tank, and all necessary copper piping and brass fittings to complete the connection to the existing plumbing system. All components were properly secured and tested to ensure proper operation of the new water heating system.
Responded to service call for leaking water heater at cold water valve connections on an 8-year-old residential unit. Upon inspection, identified active leak at cold water inlet valve, tightened connections, and verified proper sealing of braided flex connector and copper piping joints to resolve the issue.
Responded to main drain backup issue at residential property. Upon arrival, performed camera inspection of main sewer line, revealing significant buildup and staining within the drain system. Inspected utility sink plumbing connections and floor drain assembly in basement area. Successfully cleared the clogged main drain line, restoring proper drainage function throughout the system.
Completed scheduled MVP cooling maintenance visit on residential air conditioning system. Inspected outdoor condenser unit and found finned coil surface with moderate accumulation of dirt, dust, and debris between fins, along with minor fin damage typical of outdoor exposure. Examined air filter and discovered heavy soiling with significant dust and debris buildup requiring attention. Documented equipment condition through photographs showing condenser coil deterioration and filter contamination levels. System components assessed for operational efficiency and maintenance requirements per recurring service protocol.
Completed comprehensive MVP cooling maintenance on Lennox outdoor condenser unit. Performed standard inspection of electrical components including capacitor, contactor, and wiring connections, verified all terminals secure and functioning properly. Unit exterior and coils inspected, system operating within normal parameters upon completion of maintenance service.
Completed scheduled furnace tune-up and maintenance for MVP customer. Performed comprehensive system inspection including visual examination of furnace components, burner assembly, heat exchanger, and blower motor. Utilized digital inspection camera to assess crawl space conditions and verify proper system installation and clearances. All components found operating within normal parameters, and system returned to full service.
Completed scheduled MVP cooling system maintenance visit at residential property. Performed comprehensive inspection of furnace and HVAC equipment, including visual assessment of draft hood, flue connections, and PVC condensate drainage lines. Conducted temperature diagnostics using thermal probe to verify proper system operation and efficiency. Inspected electrical wiring connections, flexible ductwork, and all accessible mechanical components to ensure safe and optimal performance for the cooling season.
Diagnosed leaking rear hose bib at packing nut on slab foundation property. Replaced outdated exterior faucet with new frost-free hydrant assembly including dedicated shut-off valve and supply piping. Cut access opening through interior wall behind dryer location and installed permanent access panel for future serviceability. Completed full installation with maintenance value plan coverage.
Completed maintenance visit program on an 11-year-old furnace system. Inspected and replaced heavily soiled air filter that showed significant dust accumulation, discoloration, and debris buildup affecting system airflow and efficiency. Performed standard heating system inspection and maintenance procedures to ensure optimal operation for the heating season.
Completed scheduled MVP maintenance on a 5-year-old furnace system. Performed comprehensive inspection of heating equipment, verified proper operation of all components, and confirmed system is functioning within manufacturer specifications. Unit is operating efficiently with no issues identified at this time.
Replaced defective hot side anode rod and nipple on one-year-old Bradford 40-gallon short water heater that was actively leaking. Installed new female adapter and slip coupling to complete the repair and restore proper function to the unit.
Completed scheduled MVP heating maintenance visit. Inspected and verified proper operation of electronic control panel and circuit boards, checked all electrical connections and wiring harnesses for secure termination, and performed standard system diagnostics to ensure optimal heating system performance for the upcoming season.
Completed comprehensive furnace maintenance on MVP heating system. Performed diagnostic testing using Fieldpiece dual port manometer to measure temperature differentials and system pressures, recording inlet temperature of 118.2°F and ambient temperature of 75.2°F. Utilized Fieldpiece SC680 clamp meter to verify electrical parameters including voltage, amperage, and resistance across motor and blower assembly. Inspected internal components including blower motor, heat exchanger, wiring harnesses, and gas valve connections. Verified proper operation of all mechanical and electrical systems, confirmed R-410A refrigerant labeling and safety warnings are present and legible. All components functioning within manufacturer specifications, no repairs required at this time.
Completed preventive maintenance on a 7-year-old gas furnace under the MVP heating maintenance program. Performed diagnostic measurements using digital manometer, recording gas pressure readings at 12.55" to verify proper combustion and system operation. Inspected blower motor assembly, electrical connections, gas valve terminals, and all associated components, confirming equipment is operating within manufacturer specifications with no deficiencies noted.
Completed comprehensive AC tune-up on 11-year-old cooling system for MVP member. Performed electrical testing using clamp meter to verify proper amperage draw and system performance, inspected contactor assembly and all electrical connections for secure termination and proper operation, and documented equipment condition through detailed photography. All components operating within manufacturer specifications at time of service.