Schedule Service

HVAC, Plumbing & Electrical in Cuyahoga Falls, OH

When you need the best home services in Cuyahoga Falls, trust the team at Blind & Sons. With over 80 years in business, our team of experts offers comprehensive HVAC, plumbing, and electrical services to ensure your home is functional and comfortable.

Our highly trained technicians are the best in the industry, and we stand behind our work with unmatched warranties and guarantees. That’s why we’re known to meet your needs and exceed your expectations!

Schedule HVAC, plumbing, or electrical services today by calling Blind & Sons at 330-362-9232!

An expert plumber skillfully repairs a leaking pipe using a tool.

Same-Day Cooling Services

Stay comfortable during the muggy season with our superior cooling services. We’re proud to offer installation, replacement, repair, and maintenance on various systems, including central air, heat pumps, and ductless mini-splits. With our extensive experience, we can handle it all, and with our available emergency AC repair, we’re there for you when you need us most!

Need Services?

Reliable Heating Services

Winters in Cuyahoga Falls can be bitterly cold and snowy. Stay warm and comfortable on even the coldest day of the year with our unmatched heating services. From installation and maintenance to repair and replacement, our skilled technicians have the tools and training to provide outstanding service for various system types, including furnaces, boilers, and Hybrid Heat. Are you stuck without heat due to a breakdown? Trust our emergency heating repair service to restore your system quickly!

Stay warm all winter by scheduling a heating service with Blind & Sons at 330-362-9232!

Air Quality Services in Cuyahoga Falls

Enjoy your time inside with indoor air quality services from Blind & Sons. Our solutions can help improve your comfort & health with services and products, including:

To schedule indoor air quality services, call 330-362-9232 today!

Dependable Electrical Services

For safe and reliable electrical services, trust the licensed electricians at Blind & Sons. Our comprehensive electrical services include general installation, replacement, repair, electrical panel services, and rewiring. We also offer specialized services, including electrical inspections, whole-home generators, EV chargers, and more!

Call Blind & Sons today at 330-362-9232 to schedule your next electrical service with our team!

Top-Rated Plumbing Services

Keep your plumbing system operating at peak performance with plumbing services from Blind & Sons. Our expert plumbers are here to handle even the most complex repairs to help protect your home from water damage and ensure that you have the reliable plumbing you need.

We also provide comprehensive water heater services for standard and tankless systems to ensure you can access the hot water you need. Plus, with drain cleaning services, we’ll remove stubborn clogs to ensure your pipes can flow freely!

Trust the plumbers at Blind & Sons! Call 330-362-9232 today to schedule service!

Choose Blind & Sons in Cuyahoga Falls

Since 1937, Blind & Sons has provided outstanding HVAC, plumbing, and electrical service to the residents of Cuyahoga Falls and Northeast Ohio. We’re proud to offer emergency heating and cooling services to ensure our customers’ comfort is never compromised. Plus, with our satisfaction guarantee, you can trust you’re only getting the best possible service from our team!

Call 330-362-9232 today to schedule HVAC, plumbing, or electrical services for your Cuyahoga Falls home!

 

Recent Jobs and Reviews in Cuyahoga Falls, OH

Cuyahoga Falls, OH at a glance

Blind and Sons has completed 20 jobs in Cuyahoga Falls, OH in October 2026.

The most recent job was on October 21, 2026.

Blind and Sons has completed 1,010 jobs in Cuyahoga Falls, OH in the last 12 months.

Job Locations and Reviews

Performed a heating maintenance inspection on the furnace, using a borescope to examine the heat exchanger and burner compartment. Imaging revealed heavy rust and soot/burnt residue accumulation in the lower heat exchanger area, along with dust buildup and an oval opening in the exchanger wall, indicating possible corrosion or deterioration. Findings should be evaluated further to determine heat exchanger integrity and safe system operation.
Performed a heating maintenance inspection on the furnace, using a borescope to examine the heat exchanger and burner compartment. Imaging revealed heavy rust and soot/burnt residue accumulation in the lower heat exchanger area, along with dust buildup and an oval opening in the exchanger wall, indicating possible corrosion or deterioration. Findings should be evaluated further to determine heat exchanger integrity and safe system operation.
Jesus M.
Jesus M. Checked in
Performed a heating maintenance inspection on the furnace, using a borescope to examine the heat exchanger and burner compartment. Imaging revealed heavy rust and soot/burnt residue accumulation in the lower heat exchanger area, along with dust buildup and an oval opening in the exchanger wall, indicating possible corrosion or deterioration. Findings should be evaluated further to determine heat exchanger integrity and safe system operation.
Cuyahoga Falls, OH 44223
Performed scheduled maintenance on a 9-year-old gas-fired furnace, including inspection of the flue venting, Y-fitting connections, and PVC condensate/intake piping. Identified surface rust and corrosion along the galvanized duct elbow seams and plenum connection, and noted patched masonry and sealant at the vent transition for continued monitoring. System was cleaned and left operational.
Performed scheduled maintenance on a 9-year-old gas-fired furnace, including inspection of the flue venting, Y-fitting connections, and PVC condensate/intake piping. Identified surface rust and corrosion along the galvanized duct elbow seams and plenum connection, and noted patched masonry and sealant at the vent transition for continued monitoring. System was cleaned and left operational.
John W.
John W. Checked in
Performed scheduled maintenance on a 9-year-old gas-fired furnace, including inspection of the flue venting, Y-fitting connections, and PVC condensate/intake piping. Identified surface rust and corrosion along the galvanized duct elbow seams and plenum connection, and noted patched masonry and sealant at the vent transition for continued monitoring. System was cleaned and left operational.
Cuyahoga Falls, OH 44223
Performed seasonal furnace maintenance, including inspection of the return air filter, which was heavily loaded with dust and debris and indicated a need for replacement, and inspection of the blower assembly, where the squirrel-cage wheel showed a light accumulation of dust on the blades. Verified the blower wheel and motor shaft were intact and the housing was in serviceable condition.
Performed seasonal furnace maintenance, including inspection of the return air filter, which was heavily loaded with dust and debris and indicated a need for replacement, and inspection of the blower assembly, where the squirrel-cage wheel showed a light accumulation of dust on the blades. Verified the blower wheel and motor shaft were intact and the housing was in serviceable condition.
Daniel
Daniel Checked in
Performed seasonal furnace maintenance, including inspection of the return air filter, which was heavily loaded with dust and debris and indicated a need for replacement, and inspection of the blower assembly, where the squirrel-cage wheel showed a light accumulation of dust on the blades. Verified the blower wheel and motor shaft were intact and the housing was in serviceable condition.
Cuyahoga Falls, OH 44223
Cleared a clogged main drain line serving the upstairs shower that was causing standing water in the basement, using drain cleaning equipment to remove the obstruction and restore full flow. Verified proper drainage by running water through the affected fixture and confirmed the PVC drain piping, couplings, and floor drain connections were free of leaks and the area was free of standing water.
Cleared a clogged main drain line serving the upstairs shower that was causing standing water in the basement, using drain cleaning equipment to remove the obstruction and restore full flow. Verified proper drainage by running water through the affected fixture and confirmed the PVC drain piping, couplings, and floor drain connections were free of leaks and the area was free of standing water.
Mark W.
Mark W. Checked in
Cleared a clogged main drain line serving the upstairs shower that was causing standing water in the basement, using drain cleaning equipment to remove the obstruction and restore full flow. Verified proper drainage by running water through the affected fixture and confirmed the PVC drain piping, couplings, and floor drain connections were free of leaks and the area was free of standing water.
Cuyahoga Falls, OH 44221
Responded to a no-heat call on a furnace that would not initiate a heating cycle and performed a diagnostic evaluation of the system, including inspection of the damper control module wiring and low-voltage connections, with the unit's age and condition documented. Based on the findings, a replacement estimate was prepared for the customer's review, and the customer was advised that their service membership is due for renewal.
Responded to a no-heat call on a furnace that would not initiate a heating cycle and performed a diagnostic evaluation of the system, including inspection of the damper control module wiring and low-voltage connections, with the unit's age and condition documented. Based on the findings, a replacement estimate was prepared for the customer's review, and the customer was advised that their service membership is due for renewal.
Kevin T.
Kevin T. Checked in
Responded to a no-heat call on a furnace that would not initiate a heating cycle and performed a diagnostic evaluation of the system, including inspection of the damper control module wiring and low-voltage connections, with the unit's age and condition documented. Based on the findings, a replacement estimate was prepared for the customer's review, and the customer was advised that their service membership is due for renewal.
Cuyahoga Falls, OH 44223
Performed annual maintenance on a gas furnace, including combustion analysis with a flue gas analyzer (O2 9.7%, CO 36 ppm, CO2 6.3%, efficiency 80.8%) to verify safe, proper combustion. Measured supply and return air temperatures at the air handler cabinet to confirm normal temperature rise and heating performance. System operated within acceptable parameters at completion.
Performed annual maintenance on a gas furnace, including combustion analysis with a flue gas analyzer (O2 9.7%, CO 36 ppm, CO2 6.3%, efficiency 80.8%) to verify safe, proper combustion. Measured supply and return air temperatures at the air handler cabinet to confirm normal temperature rise and heating performance. System operated within acceptable parameters at completion.
Matthew F.
Matthew F. Checked in
Performed annual maintenance on a gas furnace, including combustion analysis with a flue gas analyzer (O2 9.7%, CO 36 ppm, CO2 6.3%, efficiency 80.8%) to verify safe, proper combustion. Measured supply and return air temperatures at the air handler cabinet to confirm normal temperature rise and heating performance. System operated within acceptable parameters at completion.
Cuyahoga Falls, OH 44221
Performed annual maintenance on a 21-year-old natural gas furnace, including inspection of the blower compartment, wiring, and venting components. Conducted a combustion analysis, with readings of 8.9% O2, 18 ppm CO, 6.8% CO2, and 81.5% efficiency, indicating CO within acceptable limits. Noted heavy corrosion and oxidation on the galvanized flue pipe elbow at the furnace connection, and recommend inspection or replacement of the vent connector to maintain safe venting.
Performed annual maintenance on a 21-year-old natural gas furnace, including inspection of the blower compartment, wiring, and venting components. Conducted a combustion analysis, with readings of 8.9% O2, 18 ppm CO, 6.8% CO2, and 81.5% efficiency, indicating CO within acceptable limits. Noted heavy corrosion and oxidation on the galvanized flue pipe elbow at the furnace connection, and recommend inspection or replacement of the vent connector to maintain safe venting.
William S.
William S. Checked in
Performed annual maintenance on a 21-year-old natural gas furnace, including inspection of the blower compartment, wiring, and venting components. Conducted a combustion analysis, with readings of 8.9% O2, 18 ppm CO, 6.8% CO2, and 81.5% efficiency, indicating CO within acceptable limits. Noted heavy corrosion and oxidation on the galvanized flue pipe elbow at the furnace connection, and recommend inspection or replacement of the vent connector to maintain safe venting.
Cuyahoga Falls, OH 44223
Performed scheduled heating maintenance on a gas furnace, including inspection of the cabinet interior, control board, and wiring, where a frayed wire sleeve and heavy dust and lint accumulation were noted. Verified draft and pressure performance using a dual-port digital manometer, with readings stable and balanced at approximately 11.7 across both ports. Inspected the inducer motor, gas valve assembly, and flue piping to confirm proper system operation.
Performed scheduled heating maintenance on a gas furnace, including inspection of the cabinet interior, control board, and wiring, where a frayed wire sleeve and heavy dust and lint accumulation were noted. Verified draft and pressure performance using a dual-port digital manometer, with readings stable and balanced at approximately 11.7 across both ports. Inspected the inducer motor, gas valve assembly, and flue piping to confirm proper system operation.
Matthew F.
Matthew F. Checked in
Performed scheduled heating maintenance on a gas furnace, including inspection of the cabinet interior, control board, and wiring, where a frayed wire sleeve and heavy dust and lint accumulation were noted. Verified draft and pressure performance using a dual-port digital manometer, with readings stable and balanced at approximately 11.7 across both ports. Inspected the inducer motor, gas valve assembly, and flue piping to confirm proper system operation.
Cuyahoga Falls, OH 44221
Responded to a no-heat call on a gas furnace under 10 years old; the unit would not initiate a heating cycle. Inspected the furnace control board, transformer, inducer assembly, pressure switch, and low-voltage and line-voltage wiring, with no visible damage, corrosion, or abnormal conditions found. Unit was restored to operation, and the customer was advised that the maintenance plan has expired and should be renewed.
Responded to a no-heat call on a gas furnace under 10 years old; the unit would not initiate a heating cycle. Inspected the furnace control board, transformer, inducer assembly, pressure switch, and low-voltage and line-voltage wiring, with no visible damage, corrosion, or abnormal conditions found. Unit was restored to operation, and the customer was advised that the maintenance plan has expired and should be renewed.
Daniel
Daniel Checked in
Responded to a no-heat call on a gas furnace under 10 years old; the unit would not initiate a heating cycle. Inspected the furnace control board, transformer, inducer assembly, pressure switch, and low-voltage and line-voltage wiring, with no visible damage, corrosion, or abnormal conditions found. Unit was restored to operation, and the customer was advised that the maintenance plan has expired and should be renewed.
Cuyahoga Falls, OH 44223
Repaired the cracked cast iron soil stack in the basement by cutting out the damaged section and installing new 3" PVC pipe with shielded rubber couplings and stainless clamps to restore a sound, watertight drain connection. Also removed and replaced the kitchen drain piping, leaving both drain lines properly sealed and free of leaks.
Repaired the cracked cast iron soil stack in the basement by cutting out the damaged section and installing new 3" PVC pipe with shielded rubber couplings and stainless clamps to restore a sound, watertight drain connection. Also removed and replaced the kitchen drain piping, leaving both drain lines properly sealed and free of leaks.
Denny J.
Denny J. Checked in
Repaired the cracked cast iron soil stack in the basement by cutting out the damaged section and installing new 3" PVC pipe with shielded rubber couplings and stainless clamps to restore a sound, watertight drain connection. Also removed and replaced the kitchen drain piping, leaving both drain lines properly sealed and free of leaks.
Cuyahoga Falls, OH 44221
Cuyahoga Falls, OH - Responded to a no-heat call on a 15-20 year old Carrier gas forced-air furnace where the blower cycled for approximately two minutes with no ignition. Diagnosed a failed hot surface igniter using a multimeter and replaced it, then verified proper ignition sequence, gas valve operation, burner flame, and blower function. System restored to normal heating operation.
Matthew F.
Matthew F. Checked in
Responded to a no-heat call on a 15-20 year old Carrier gas forced-air furnace where the blower cycled for approximately two minutes with no ignition. Diagnosed a failed hot surface igniter using a multimeter and replaced it, then verified proper ignition sequence, gas valve operation, burner flame, and blower function. System restored to normal heating operation.
Cuyahoga Falls, OH 44223
Cuyahoga Falls, OH - Responded to a service call on a one-month-old 21kW standby generator exhibiting abnormal engine revving after previously cycling normally, and replaced the printed circuit board (PCB) to address the speed control irregularity. Also inspected the rear lower enclosure panel openings and supplied the requested cover plates, and verified the unit and gas line connections on the concrete pad were secure with no visible damage.
Bradley L.
Bradley L. Checked in
Responded to a service call on a one-month-old 21kW standby generator exhibiting abnormal engine revving after previously cycling normally, and replaced the printed circuit board (PCB) to address the speed control irregularity. Also inspected the rear lower enclosure panel openings and supplied the requested cover plates, and verified the unit and gas line connections on the concrete pad were secure with no visible damage.
Cuyahoga Falls, OH 44221
Performed seasonal heating system maintenance and inspected the gas supply piping and shutoff components at the furnace. Verified operation of the brass ball valve on the black iron supply line and noted surface corrosion and residue at the threaded joints and union fitting. Recommend monitoring the corroded fittings and checking for leaks at the connections during future visits, and replacing them if deterioration progresses.
Performed seasonal heating system maintenance and inspected the gas supply piping and shutoff components at the furnace. Verified operation of the brass ball valve on the black iron supply line and noted surface corrosion and residue at the threaded joints and union fitting. Recommend monitoring the corroded fittings and checking for leaks at the connections during future visits, and replacing them if deterioration progresses.
Colton D.
Colton D. Checked in
Performed seasonal heating system maintenance and inspected the gas supply piping and shutoff components at the furnace. Verified operation of the brass ball valve on the black iron supply line and noted surface corrosion and residue at the threaded joints and union fitting. Recommend monitoring the corroded fittings and checking for leaks at the connections during future visits, and replacing them if deterioration progresses.
Cuyahoga Falls, OH 44223
Performed a seasonal heating tune-up on a 9-year-old forced-air gas furnace, inspecting the cabinet, gas piping and shutoff, PVC condensate/venting, wiring connections, and ductwork, along with the Aprilaire humidifier and condensate pump. The system was operating properly at arrival and was prepared for winter heating demands. Photos were taken to document the equipment and installation condition.
Performed a seasonal heating tune-up on a 9-year-old forced-air gas furnace, inspecting the cabinet, gas piping and shutoff, PVC condensate/venting, wiring connections, and ductwork, along with the Aprilaire humidifier and condensate pump. The system was operating properly at arrival and was prepared for winter heating demands. Photos were taken to document the equipment and installation condition.
Daniel S.
Daniel S. Checked in
Performed a seasonal heating tune-up on a 9-year-old forced-air gas furnace, inspecting the cabinet, gas piping and shutoff, PVC condensate/venting, wiring connections, and ductwork, along with the Aprilaire humidifier and condensate pump. The system was operating properly at arrival and was prepared for winter heating demands. Photos were taken to document the equipment and installation condition.
Cuyahoga Falls, OH 44223
Installed a whole-home surge protector on the right side of the electrical panel by repurposing the unused electric range circuit: capped off the range conductors, removed the existing breaker, and installed a properly sized breaker for the surge protective device. Inspected the grounding system and found a single undersized ground rod outside, with a secondary bonding conductor jumped across the water meter; recommended adding two ground rods to meet current code, and noted that reliance on the water meter bonding may affect the device warranty. Identified a code violation on a 30-amp breaker feeding 12 AWG wire to the panel GFI and doorbell transformer (oversized overcurrent protection on undersized conductor), and documented a downstairs bathroom GFI on a dimmer to be removed, capped, and covered with a blank plate.
Installed a whole-home surge protector on the right side of the electrical panel by repurposing the unused electric range circuit: capped off the range conductors, removed the existing breaker, and installed a properly sized breaker for the surge protective device. Inspected the grounding system and found a single undersized ground rod outside, with a secondary bonding conductor jumped across the water meter; recommended adding two ground rods to meet current code, and noted that reliance on the water meter bonding may affect the device warranty. Identified a code violation on a 30-amp breaker feeding 12 AWG wire to the panel GFI and doorbell transformer (oversized overcurrent protection on undersized conductor), and documented a downstairs bathroom GFI on a dimmer to be removed, capped, and covered with a blank plate.
Andrew V.
Andrew V. Checked in
Installed a whole-home surge protector on the right side of the electrical panel by repurposing the unused electric range circuit: capped off the range conductors, removed the existing breaker, and installed a properly sized breaker for the surge protective device. Inspected the grounding system and found a single undersized ground rod outside, with a secondary bonding conductor jumped across the water meter; recommended adding two ground rods to meet current code, and noted that reliance on the water meter bonding may affect the device warranty. Identified a code violation on a 30-amp breaker feeding 12 AWG wire to the panel GFI and doorbell transformer (oversized overcurrent protection on undersized conductor), and documented a downstairs bathroom GFI on a dimmer to be removed, capped, and covered with a blank plate.
Cuyahoga Falls, OH 44223
Performed a seasonal tune-up on a 3-year-old system, including inspection of the condensate drain line and measurement of system pressure with a digital manometer, with all readings and connections within normal range. Checked condenser electrical components with a clamp meter, verifying amperage draw (approx. 6.95A) and wiring integrity, and found no visible damage, frost, or rust.
Performed a seasonal tune-up on a 3-year-old system, including inspection of the condensate drain line and measurement of system pressure with a digital manometer, with all readings and connections within normal range. Checked condenser electrical components with a clamp meter, verifying amperage draw (approx. 6.95A) and wiring integrity, and found no visible damage, frost, or rust.
Colton D.
Colton D. Checked in
Performed a seasonal tune-up on a 3-year-old system, including inspection of the condensate drain line and measurement of system pressure with a digital manometer, with all readings and connections within normal range. Checked condenser electrical components with a clamp meter, verifying amperage draw (approx. 6.95A) and wiring integrity, and found no visible damage, frost, or rust.
Cuyahoga Falls, OH 44223
Performed annual heating maintenance tune-up on a 4-year-old Lennox furnace with a functioning system. Inspected the unit's burner/flame viewing port, cabinet, supply plenum and ductwork, whole-home humidifier connection, and condensate drain line, finding no frost, heavy rust, cracks, or other deficiencies. System was operating properly with no repairs required.
Performed annual heating maintenance tune-up on a 4-year-old Lennox furnace with a functioning system. Inspected the unit's burner/flame viewing port, cabinet, supply plenum and ductwork, whole-home humidifier connection, and condensate drain line, finding no frost, heavy rust, cracks, or other deficiencies. System was operating properly with no repairs required.
Colton D.
Colton D. Checked in
Performed annual heating maintenance tune-up on a 4-year-old Lennox furnace with a functioning system. Inspected the unit's burner/flame viewing port, cabinet, supply plenum and ductwork, whole-home humidifier connection, and condensate drain line, finding no frost, heavy rust, cracks, or other deficiencies. System was operating properly with no repairs required.
Cuyahoga Falls, OH 44221
Responded to a main drain backup occurring with each toilet flush and accessed the basement drain system to assess the blockage. Performed a main line cleanout to restore flow and began a video camera inspection of the line, with a follow-up visit required to complete the inspection and evaluate the condition of the drain.
Responded to a main drain backup occurring with each toilet flush and accessed the basement drain system to assess the blockage. Performed a main line cleanout to restore flow and began a video camera inspection of the line, with a follow-up visit required to complete the inspection and evaluate the condition of the drain.
Denny J.
Denny J. Checked in
Responded to a main drain backup occurring with each toilet flush and accessed the basement drain system to assess the blockage. Performed a main line cleanout to restore flow and began a video camera inspection of the line, with a follow-up visit required to complete the inspection and evaluate the condition of the drain.
Cuyahoga Falls, OH 44221
Replaced the damaged liquid-tight conduit run routed beneath the deck to the rear of the standby generator, as the connector threads were stripped and the fitting was pulling out of the enclosure. Installed new liquid-tight conduit with a secure connector at the generator and re-secured the run to the deck framing with conduit clamps. Removed a cracked, corroded ring terminal found during the repair, and verified the connection and conduit run were secure.
Replaced the damaged liquid-tight conduit run routed beneath the deck to the rear of the standby generator, as the connector threads were stripped and the fitting was pulling out of the enclosure. Installed new liquid-tight conduit with a secure connector at the generator and re-secured the run to the deck framing with conduit clamps. Removed a cracked, corroded ring terminal found during the repair, and verified the connection and conduit run were secure.
Matthew H.
Matthew H. Checked in
Replaced the damaged liquid-tight conduit run routed beneath the deck to the rear of the standby generator, as the connector threads were stripped and the fitting was pulling out of the enclosure. Installed new liquid-tight conduit with a secure connector at the generator and re-secured the run to the deck framing with conduit clamps. Removed a cracked, corroded ring terminal found during the repair, and verified the connection and conduit run were secure.
Cuyahoga Falls, OH 44223
Installed a new 50-gallon, 8-year short electric Bradford White water heater with a new thermal expansion tank, using a water heater installation kit. Reconnected the copper supply piping with soldered joints and reused the existing ball valve and drain pan. The unit is in place with no visible leaks, rust, or damage.
Installed a new 50-gallon, 8-year short electric Bradford White water heater with a new thermal expansion tank, using a water heater installation kit. Reconnected the copper supply piping with soldered joints and reused the existing ball valve and drain pan. The unit is in place with no visible leaks, rust, or damage.
Isaiah H.
Isaiah H. Checked in
Installed a new 50-gallon, 8-year short electric Bradford White water heater with a new thermal expansion tank, using a water heater installation kit. Reconnected the copper supply piping with soldered joints and reused the existing ball valve and drain pan. The unit is in place with no visible leaks, rust, or damage.
Cuyahoga Falls, OH 44223

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image