Schedule Service

HVAC, Electrical & Plumbing Services in Kent, OH – Trusted by Homeowners Since 1937

Smart Home Installation

In Kent, OH, where the seasons can swing from icy winters to sweltering summers, it’s essential to have a home that keeps up. That’s why homeowners turn to Blind & Sons—a trusted name in HVAC, plumbing, and electrical services for more than 85 years. We’re proud to offer complete solutions to keep your Kent home running safely, efficiently, and comfortably all year long.

From emergency furnace repairs to whole-home generator installs, we handle it all with professionalism and pride. We’ve built our reputation by putting Kent families first, and it shows in every service call we make.

Call 330-362-9232 or schedule a visit online to book expert home services in Kent.

Proudly Serving Kent, OH

Situated along the scenic Cuyahoga River, Kent, OH offers a unique blend of historic charm and a laid-back, community-focused atmosphere. It’s known for Kent State University, its vibrant downtown filled with local cafés and shops, and the strong sense of community that runs through every neighborhood. From the scenic walking trails and Kent Bog to weekly events like the Haymaker Farmers’ Market, Kent offers residents a unique mix of natural beauty and lively culture.

Homes here range from charming older properties with character to more modern builds, each with its own needs. At Blind & Sons, we understand the local nuances that come with living in Kent. We’ve worked in homes all over town and know how to adapt our services to match the specific requirements of your property—whether that means working with older plumbing systems or helping you install an energy-efficient HVAC upgrade. Our commitment to Kent goes beyond service calls—we’re proud to be part of the community and to help our neighbors keep their homes running comfortably year-round.

Need Services?

Kent Heating Services That Deliver Lasting Comfort

When winter arrives in Northeast Ohio, your heating system becomes the heart of your home. Blind & Sons provides top-quality heating services to ensure you stay warm no matter how cold it gets outside. Our expert technicians are trained to work on all types of heating systems and will never recommend a replacement unless it’s truly necessary.

We offer:

We prioritize fast service, thorough diagnostics, and repairs that last—because your comfort and safety are our top priorities.

Air Conditioning Services in Kent

Summers in Kent can bring high humidity and long stretches of heat, and when your air conditioning system starts to struggle, it can quickly turn your home into an uncomfortable space. At Blind & Sons, we provide dependable air conditioning services designed to help Kent homeowners stay cool, relaxed, and worry-free throughout the warmest months of the year.

Our Kent cooling services include:

We take the time to properly assess your home’s cooling needs and recommend systems that deliver efficient performance for years to come. Whether you’re upgrading an older system or troubleshooting strange noises, we’ll get the job done right.

Improve the Air You Breathe with Indoor Air Quality Services in Kent

If you’ve noticed more sneezing, coughing, or stale smells in your home, poor indoor air quality could be the cause. Our indoor air quality solutions are designed to make your home not just comfortable—but healthy too.

We offer:

Indoor air pollution is a growing concern, especially in tightly sealed homes. Let our team evaluate your home and create a custom plan to clean up your air.

Professional Electrical Services in Kent

When electrical issues strike, they’re more than just annoying—they can be dangerous. That’s why Blind & Sons takes a safety-first approach to all our electrical services in Kent. Whether you’re upgrading a fuse box or adding an EV charger, our licensed electricians have you covered.

Our electrical services in Kent include:

No matter how big or small the job, we approach every project with care, precision, and a commitment to safety and compliance.

Reliable Plumbing Services in Kent When You Need Them Most

Gas burner

Plumbing problems can go from small annoyances to major emergencies in no time. Our experienced plumbers are here to resolve issues quickly and thoroughly—saving you time, money, and stress. From leaky pipes to major upgrades, we offer the full range of plumbing services Kent homeowners need.

Services include:

Our technicians arrive on time, treat your home with care, and make sure the work is done right the first time.

Need Services?

Why Kent Homeowners Trust Blind & Sons

At Blind & Sons, we don’t believe in cutting corners or offering one-size-fits-all solutions. Every home is different, and every homeowner deserves personal attention. That’s what has helped us serve the Kent community for over eight decades.

Here’s what you can expect when you work with us:

  • Over 85 years of trusted service in Northeast Ohio
  • emergency support when you need it most
  • Honest, upfront pricing with no surprise fees
  • Fully licensed, background-checked technicians
  • Clean, respectful service and attention to detail
  • Online scheduling and repair discounts
  • 100% satisfaction guarantee on all services

We treat your home as if it were our own—and we won’t rest until you’re completely satisfied.

Schedule HVAC, Electrical & Plumbing Services in Kent, OH

No matter what your home needs, Blind & Sons is here to help. From a dripping faucet to a full HVAC overhaul, you can count on us for expert service that puts your comfort and safety first.

Call 330-362-9232 or book your service online today and discover why Blind & Sons is Kent’s trusted name in home comfort.

Blind & Sons—Keeping Kent homes comfortable, safe, and running smoothly since 1937.

 

Recent Jobs and Reviews in Kent, OH

Kent, OH at a glance

Blind and Sons has completed 20 jobs in Kent, OH between October 2026 and November 2026.

The most recent job was on November 9, 2026.

Blind and Sons has completed 389 jobs in Kent, OH in the last 12 months.

Job Locations and Reviews

Performed annual maintenance on a 6-year-old natural gas furnace, including a combustion analysis verifying safe, efficient operation (CO 25 ppm, CO2 7.5%, stack temperature 114°F, 91.9% efficiency). During inspection, frost and ice accumulation was observed on the evaporator coil, with surface rust on the cabinet flange; recommend further evaluation of airflow and refrigerant charge to determine the cause of the icing.
Performed annual maintenance on a 6-year-old natural gas furnace, including a combustion analysis verifying safe, efficient operation (CO 25 ppm, CO2 7.5%, stack temperature 114°F, 91.9% efficiency). During inspection, frost and ice accumulation was observed on the evaporator coil, with surface rust on the cabinet flange; recommend further evaluation of airflow and refrigerant charge to determine the cause of the icing.
Stephanie E.
Stephanie E. Checked in
Performed annual maintenance on a 6-year-old natural gas furnace, including a combustion analysis verifying safe, efficient operation (CO 25 ppm, CO2 7.5%, stack temperature 114°F, 91.9% efficiency). During inspection, frost and ice accumulation was observed on the evaporator coil, with surface rust on the cabinet flange; recommend further evaluation of airflow and refrigerant charge to determine the cause of the icing.
Kent, OH 44240
Performed annual furnace maintenance, including a combustion analysis on the natural gas unit that returned O2 at 11.0%, CO at 21 ppm, CO2 at 5.6%, and a reported efficiency of 99.3%. Inspected the return air filter and found heavy dust and debris loading on the pleats, indicating the filter is due for replacement.
Performed annual furnace maintenance, including a combustion analysis on the natural gas unit that returned O2 at 11.0%, CO at 21 ppm, CO2 at 5.6%, and a reported efficiency of 99.3%. Inspected the return air filter and found heavy dust and debris loading on the pleats, indicating the filter is due for replacement.
Stephanie E.
Stephanie E. Checked in
Performed annual furnace maintenance, including a combustion analysis on the natural gas unit that returned O2 at 11.0%, CO at 21 ppm, CO2 at 5.6%, and a reported efficiency of 99.3%. Inspected the return air filter and found heavy dust and debris loading on the pleats, indicating the filter is due for replacement.
Kent, OH 44240
Kent, OH - Performed an on-site estimate for a zoning system installation, evaluating existing galvanized sheet metal ductwork in the basement/utility space, including the round trunk, rectangular-to-round transition, and branch collars. Ductwork was found in good condition with properly secured, screw-fastened collars and seams and no visible rust, damage, or deterioration, indicating it can be modified to accommodate zone dampers and branch control as part of the replacement scope.
Lee L.
Lee L. Checked in
Performed an on-site estimate for a zoning system installation, evaluating existing galvanized sheet metal ductwork in the basement/utility space, including the round trunk, rectangular-to-round transition, and branch collars. Ductwork was found in good condition with properly secured, screw-fastened collars and seams and no visible rust, damage, or deterioration, indicating it can be modified to accommodate zone dampers and branch control as part of the replacement scope.
Kent, OH 44240
Responded to a no-heat call on a 3-year-old furnace and diagnosed the thermostat as locked into a programmed schedule that could not be overridden, preventing a call for heat. Reviewed and reprogrammed the thermostat settings to restore normal operation, then inspected the furnace cabinet and found no frost, cracks, or rust, noting minor thread sealant residue and slight corrosion at a galvanized union fitting on the adjacent piping as a condition to monitor.
Responded to a no-heat call on a 3-year-old furnace and diagnosed the thermostat as locked into a programmed schedule that could not be overridden, preventing a call for heat. Reviewed and reprogrammed the thermostat settings to restore normal operation, then inspected the furnace cabinet and found no frost, cracks, or rust, noting minor thread sealant residue and slight corrosion at a galvanized union fitting on the adjacent piping as a condition to monitor.
Matthew F.
Matthew F. Checked in
Responded to a no-heat call on a 3-year-old furnace and diagnosed the thermostat as locked into a programmed schedule that could not be overridden, preventing a call for heat. Reviewed and reprogrammed the thermostat settings to restore normal operation, then inspected the furnace cabinet and found no frost, cracks, or rust, noting minor thread sealant residue and slight corrosion at a galvanized union fitting on the adjacent piping as a condition to monitor.
Kent, OH 44240
Performed a heating maintenance inspection on the system, including evaluation of the ignition components (hot surface igniter) and a visual inspection of the indoor evaporator coil cabinet. Observed light frost and mineral buildup with surface grime on the coil return bends and refrigerant lines, and noted the condition of the condensate drain piping, insulation, and distributor tubing for follow-up as needed.
Performed a heating maintenance inspection on the system, including evaluation of the ignition components (hot surface igniter) and a visual inspection of the indoor evaporator coil cabinet. Observed light frost and mineral buildup with surface grime on the coil return bends and refrigerant lines, and noted the condition of the condensate drain piping, insulation, and distributor tubing for follow-up as needed.
Stephanie E.
Stephanie E. Checked in
Performed a heating maintenance inspection on the system, including evaluation of the ignition components (hot surface igniter) and a visual inspection of the indoor evaporator coil cabinet. Observed light frost and mineral buildup with surface grime on the coil return bends and refrigerant lines, and noted the condition of the condensate drain piping, insulation, and distributor tubing for follow-up as needed.
Kent, OH 44240
Performed recurring heating maintenance on a natural gas furnace, including inspection of the control board, wiring harness, and blower compartment, and performed a combustion analysis with a Bacharach analyzer (O₂ 5.0%, CO 197 ppm, CO₂ 9.0%, efficiency 82.5%). Documented a dust-laden cabinet interior, corrosion on the blower housing, and a heat-damaged, charred wire insulation on the wiring harness, which should be repaired or replaced. The elevated CO reading should also be evaluated through burner and heat exchanger inspection and adjustment.
Performed recurring heating maintenance on a natural gas furnace, including inspection of the control board, wiring harness, and blower compartment, and performed a combustion analysis with a Bacharach analyzer (O₂ 5.0%, CO 197 ppm, CO₂ 9.0%, efficiency 82.5%). Documented a dust-laden cabinet interior, corrosion on the blower housing, and a heat-damaged, charred wire insulation on the wiring harness, which should be repaired or replaced. The elevated CO reading should also be evaluated through burner and heat exchanger inspection and adjustment.
Stephanie E.
Stephanie E. Checked in
Performed recurring heating maintenance on a natural gas furnace, including inspection of the control board, wiring harness, and blower compartment, and performed a combustion analysis with a Bacharach analyzer (O₂ 5.0%, CO 197 ppm, CO₂ 9.0%, efficiency 82.5%). Documented a dust-laden cabinet interior, corrosion on the blower housing, and a heat-damaged, charred wire insulation on the wiring harness, which should be repaired or replaced. The elevated CO reading should also be evaluated through burner and heat exchanger inspection and adjustment.
Kent, OH 44240
Performed startup and commissioning of the oil-fired furnace, verifying proper ignition, burner operation, and control board and wiring connections to the ductwork and plenum. Conducted combustion analysis with a Bacharach analyzer on #2 oil, recording O2 at 5.3%, CO2 at 11.7%, CO at 42 ppm, and 85.3% combustion efficiency, confirming the unit is operating within acceptable parameters.
Performed startup and commissioning of the oil-fired furnace, verifying proper ignition, burner operation, and control board and wiring connections to the ductwork and plenum. Conducted combustion analysis with a Bacharach analyzer on #2 oil, recording O2 at 5.3%, CO2 at 11.7%, CO at 42 ppm, and 85.3% combustion efficiency, confirming the unit is operating within acceptable parameters.
William S.
William S. Checked in
Performed startup and commissioning of the oil-fired furnace, verifying proper ignition, burner operation, and control board and wiring connections to the ductwork and plenum. Conducted combustion analysis with a Bacharach analyzer on #2 oil, recording O2 at 5.3%, CO2 at 11.7%, CO at 42 ppm, and 85.3% combustion efficiency, confirming the unit is operating within acceptable parameters.
Kent, OH 44240
Removed the existing oil-fired furnace and installed a replacement unit with new galvanized supply and return ductwork connections in the basement mechanical space. Mounted the digital thermostat and control/zoning board, terminated and secured the low-voltage control wiring with wire connectors, and completed the line-voltage junction box connections at the overhead supply plenum. Verified safe system operation after installation.
Removed the existing oil-fired furnace and installed a replacement unit with new galvanized supply and return ductwork connections in the basement mechanical space. Mounted the digital thermostat and control/zoning board, terminated and secured the low-voltage control wiring with wire connectors, and completed the line-voltage junction box connections at the overhead supply plenum. Verified safe system operation after installation.
Uriel W.
Uriel W. Checked in
Removed the existing oil-fired furnace and installed a replacement unit with new galvanized supply and return ductwork connections in the basement mechanical space. Mounted the digital thermostat and control/zoning board, terminated and secured the low-voltage control wiring with wire connectors, and completed the line-voltage junction box connections at the overhead supply plenum. Verified safe system operation after installation.
Kent, OH 44240
Performed an on-site electrical estimate for a standby generator installation, evaluating the property's service entrance and available routing paths for the generator feed and transfer switch connection. Documented existing conditions of the crawl space and basement utility areas, including framing, drain piping, and plumbing runs, to plan conduit routing and identify potential obstructions for the install.
Performed an on-site electrical estimate for a standby generator installation, evaluating the property's service entrance and available routing paths for the generator feed and transfer switch connection. Documented existing conditions of the crawl space and basement utility areas, including framing, drain piping, and plumbing runs, to plan conduit routing and identify potential obstructions for the install.
Eric L.
Eric L. Checked in
Performed an on-site electrical estimate for a standby generator installation, evaluating the property's service entrance and available routing paths for the generator feed and transfer switch connection. Documented existing conditions of the crawl space and basement utility areas, including framing, drain piping, and plumbing runs, to plan conduit routing and identify potential obstructions for the install.
Kent, OH 44240
Performed annual heating maintenance on the gas furnace, inspecting the inducer motor, pressure switch, wiring harness, and control board, with the board's status LEDs indicating normal operation. Verified the PVC condensate drain and venting assembly, along with adjacent gas, copper, and ductwork connections, and found no visible rust, frost, or damage. The system was left in proper working order.
Performed annual heating maintenance on the gas furnace, inspecting the inducer motor, pressure switch, wiring harness, and control board, with the board's status LEDs indicating normal operation. Verified the PVC condensate drain and venting assembly, along with adjacent gas, copper, and ductwork connections, and found no visible rust, frost, or damage. The system was left in proper working order.
Daniel S.
Daniel S. Checked in
Performed annual heating maintenance on the gas furnace, inspecting the inducer motor, pressure switch, wiring harness, and control board, with the board's status LEDs indicating normal operation. Verified the PVC condensate drain and venting assembly, along with adjacent gas, copper, and ductwork connections, and found no visible rust, frost, or damage. The system was left in proper working order.
Kent, OH 44240
Performed MVP furnace maintenance, including inspection of the integrated furnace control board, relays, terminal block, and wiring harness; no signs of overheating, burn marks, corrosion, or damage were found, and wiring was confirmed to be secure and properly routed. Inspected the flue/vent and burner assembly area for residue buildup and checked the run capacitor rating (approx. 5 µF) as noted on the unit. Furnace was left in proper working condition.
Performed MVP furnace maintenance, including inspection of the integrated furnace control board, relays, terminal block, and wiring harness; no signs of overheating, burn marks, corrosion, or damage were found, and wiring was confirmed to be secure and properly routed. Inspected the flue/vent and burner assembly area for residue buildup and checked the run capacitor rating (approx. 5 µF) as noted on the unit. Furnace was left in proper working condition.
Stephanie E.
Stephanie E. Checked in
Performed MVP furnace maintenance, including inspection of the integrated furnace control board, relays, terminal block, and wiring harness; no signs of overheating, burn marks, corrosion, or damage were found, and wiring was confirmed to be secure and properly routed. Inspected the flue/vent and burner assembly area for residue buildup and checked the run capacitor rating (approx. 5 µF) as noted on the unit. Furnace was left in proper working condition.
Kent, OH 44240
Performed annual maintenance on the gas-fired furnace, including a combustion analysis that returned O2 at 8.6%, CO at 36 ppm, CO2 at 6.9%, and 96.3% efficiency, all within acceptable operating ranges. Inspected the integrated control board, wiring harness, and terminal connections, finding no evidence of damage, corrosion, or overheating, and verified the system was operating normally with the status indicator lit.
Performed annual maintenance on the gas-fired furnace, including a combustion analysis that returned O2 at 8.6%, CO at 36 ppm, CO2 at 6.9%, and 96.3% efficiency, all within acceptable operating ranges. Inspected the integrated control board, wiring harness, and terminal connections, finding no evidence of damage, corrosion, or overheating, and verified the system was operating normally with the status indicator lit.
Stephanie E.
Stephanie E. Checked in
Performed annual maintenance on the gas-fired furnace, including a combustion analysis that returned O2 at 8.6%, CO at 36 ppm, CO2 at 6.9%, and 96.3% efficiency, all within acceptable operating ranges. Inspected the integrated control board, wiring harness, and terminal connections, finding no evidence of damage, corrosion, or overheating, and verified the system was operating normally with the status indicator lit.
Kent, OH 44240
Performed main drain cleanout to clear a suspected shared-line blockage affecting the kitchen sink and dishwasher drain, which was causing intermittent backups and standing water at the dishwasher. Inspected the under-sink drain assembly and found a weeping P-trap slip-nut joint with rust staining and water-damaged cabinet flooring, indicating a slow leak at the connection. Restored proper drainage and verified flow through the kitchen drain line.
Performed main drain cleanout to clear a suspected shared-line blockage affecting the kitchen sink and dishwasher drain, which was causing intermittent backups and standing water at the dishwasher. Inspected the under-sink drain assembly and found a weeping P-trap slip-nut joint with rust staining and water-damaged cabinet flooring, indicating a slow leak at the connection. Restored proper drainage and verified flow through the kitchen drain line.
Mark W.
Mark W. Checked in
Performed main drain cleanout to clear a suspected shared-line blockage affecting the kitchen sink and dishwasher drain, which was causing intermittent backups and standing water at the dishwasher. Inspected the under-sink drain assembly and found a weeping P-trap slip-nut joint with rust staining and water-damaged cabinet flooring, indicating a slow leak at the connection. Restored proper drainage and verified flow through the kitchen drain line.
Kent, OH 44240
Kent, OH - Removed the existing well pressure tank and installed a new 40-gallon Flex-Lite pre-charged tank in the basement, reconnecting it to the pressure switch, brass fittings, and supply piping. Verified proper air pre-charge, system pressure, and leak-free connections, with the well system restored to normal operation.
Denny J.
Denny J. Checked in
Removed the existing well pressure tank and installed a new 40-gallon Flex-Lite pre-charged tank in the basement, reconnecting it to the pressure switch, brass fittings, and supply piping. Verified proper air pre-charge, system pressure, and leak-free connections, with the well system restored to normal operation.
Kent, OH 44240
Corrected grounding and bonding deficiencies identified in the failed inspection by adjusting the grounding electrode system and bonding connections at the main service panel to meet code requirements. Utility locate marker flags were present at the exterior work area, and photos of the final adjustments and panel were taken for the inspector's review.
Corrected grounding and bonding deficiencies identified in the failed inspection by adjusting the grounding electrode system and bonding connections at the main service panel to meet code requirements. Utility locate marker flags were present at the exterior work area, and photos of the final adjustments and panel were taken for the inspector's review.
Logan H.
Logan H. Checked in
Corrected grounding and bonding deficiencies identified in the failed inspection by adjusting the grounding electrode system and bonding connections at the main service panel to meet code requirements. Utility locate marker flags were present at the exterior work area, and photos of the final adjustments and panel were taken for the inspector's review.
Kent, OH 44240
Performed scheduled heating maintenance on a 4-year-old furnace, including inspection of the blower assembly, gas piping, wiring connections, and sensor probe mounting. Measured system pressures with a dual-port digital manometer to verify proper operation, and found no signs of rust, frost, or component damage.
Performed scheduled heating maintenance on a 4-year-old furnace, including inspection of the blower assembly, gas piping, wiring connections, and sensor probe mounting. Measured system pressures with a dual-port digital manometer to verify proper operation, and found no signs of rust, frost, or component damage.
Matthew F.
Matthew F. Checked in
Performed scheduled heating maintenance on a 4-year-old furnace, including inspection of the blower assembly, gas piping, wiring connections, and sensor probe mounting. Measured system pressures with a dual-port digital manometer to verify proper operation, and found no signs of rust, frost, or component damage.
Kent, OH 44240
Responded to a sulfur odor complaint following a recent tank-style water heater installation. Inspected the unit and removed the anode rod, which showed heavy mineral encrustation, a common source of hydrogen sulfide odor caused by sulfate-reducing bacteria reacting with the sacrificial anode. Corrected the issue to eliminate the odor and restore normal water quality.
Responded to a sulfur odor complaint following a recent tank-style water heater installation. Inspected the unit and removed the anode rod, which showed heavy mineral encrustation, a common source of hydrogen sulfide odor caused by sulfate-reducing bacteria reacting with the sacrificial anode. Corrected the issue to eliminate the odor and restore normal water quality.
James P.
James P. Checked in
Responded to a sulfur odor complaint following a recent tank-style water heater installation. Inspected the unit and removed the anode rod, which showed heavy mineral encrustation, a common source of hydrogen sulfide odor caused by sulfate-reducing bacteria reacting with the sacrificial anode. Corrected the issue to eliminate the odor and restore normal water quality.
Kent, OH 44240
Kent, OH - Connected the dishwasher's water supply lines, which had been improperly hooked up during the previous installation. Routed and secured the supply connection from the existing PEX and copper supply piping, verified fittings were tight, and confirmed there were no leaks at the connections.
James P.
James P. Checked in
Connected the dishwasher's water supply lines, which had been improperly hooked up during the previous installation. Routed and secured the supply connection from the existing PEX and copper supply piping, verified fittings were tight, and confirmed there were no leaks at the connections.
Kent, OH 44240
Responded to an active basement flooding call affecting two bathrooms and the utility room, with non-flushing toilets and a flooded shower, and performed a diagnostic inspection to locate the water source. Inspection found significant water pooling and rust-colored staining on the concrete floor around the base of the furnace, as well as standing water in the toilet bowl, indicating a drain/sewer backup condition. Documented all findings with photos and identified the affected fixtures and areas for further repair.
Responded to an active basement flooding call affecting two bathrooms and the utility room, with non-flushing toilets and a flooded shower, and performed a diagnostic inspection to locate the water source. Inspection found significant water pooling and rust-colored staining on the concrete floor around the base of the furnace, as well as standing water in the toilet bowl, indicating a drain/sewer backup condition. Documented all findings with photos and identified the affected fixtures and areas for further repair.
Mark W.
Mark W. Checked in
Responded to an active basement flooding call affecting two bathrooms and the utility room, with non-flushing toilets and a flooded shower, and performed a diagnostic inspection to locate the water source. Inspection found significant water pooling and rust-colored staining on the concrete floor around the base of the furnace, as well as standing water in the toilet bowl, indicating a drain/sewer backup condition. Documented all findings with photos and identified the affected fixtures and areas for further repair.
Kent, OH 44240
Kent, OH - Returned to the site to replace the failed hot surface igniter on the gas furnace using a previously ordered replacement part. Removed the old igniter from the burner assembly, installed the new igniter with its mounting bracket and gasket, and reconnected the wiring harness. Verified secure installation, completing the repair to restore proper ignition operation.
Stephanie E.
Stephanie E. Checked in
Returned to the site to replace the failed hot surface igniter on the gas furnace using a previously ordered replacement part. Removed the old igniter from the burner assembly, installed the new igniter with its mounting bracket and gasket, and reconnected the wiring harness. Verified secure installation, completing the repair to restore proper ignition operation.
Kent, OH 44240

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image