Schedule Service

Blind & Sons: Trusted HVAC, Plumbing & Electrical Services in Massillon, OH

A gas furnace installed in a residential basement

Established in 1937, Blind & Sons has been Massillon’s premier source for high-quality HVAC, plumbing, and electrical services. We’re proud to serve homeowners throughout this historic Ohio city with trusted craftsmanship, availability, and no overtime fees. Our licensed and insured technicians bring a legacy of nearly 100 years of experience, along with modern solutions tailored to every home. Whether you need emergency repairs or scheduled maintenance, Blind & Sons delivers peace of mind with every visit.

Call 330-362-9232 today to schedule fast, dependable service in Massillon, OH or contact us online!

Proudly Serving the City of Massillon

Massillon, OH, isn’t just known for its historic roots and legendary football pride—it’s a city where tradition meets progress. With a blend of early 20th-century homes, revitalized neighborhoods, and new residential developments, each property presents its own unique challenges when it comes to comfort, safety, and efficiency.

At Blind & Sons, we know Massillon inside and out. From homes near Duncan Plaza and the downtown district to those out toward Amherst or Perry Heights, we’ve tailored solutions for every type of structure. Our deep local knowledge and nearly a century of experience allow us to provide custom HVAC, plumbing, and electrical service plans built around your home’s age, architecture, and your family’s everyday needs.

Comprehensive Massillon Plumbing Services 

From clogged drains and leaky faucets to full water heater replacements, Blind & Sons provides expert plumbing solutions backed by decades of experience. We respond quickly, treat your home with respect, and deliver lasting results. Blind & Sons offer Massillon plumbing services that include:

  • Drain Cleaning & Sewer Services: We clear clogs, clean drains, and use video camera inspections to identify blockages or damage deep within your pipes.
  • Water Heater Services: Whether you need a traditional tank or are upgrading to a tankless model, we handle installation, repair, and routine maintenance.
  • Reverse Osmosis Systems: Improve the taste and quality of your water with advanced filtration installed by our experienced plumbers.
  • General Plumbing Repairs: We repair kitchen and bathroom fixtures, leaky pipes, broken shut-off valves, and more.
    • Gas Line Services: Our team installs and repairs residential gas lines to ensure the safe and efficient delivery of natural gas to your appliances and heating systems.
    • Leak Detection: Using advanced diagnostic tools, we locate and resolve hidden water or gas leaks before they lead to costly damage or safety risks.

    Sump Pump Services: Protect your basement from water damage with expert sump pump installation, maintenance, and repair services. We ensure your system activates when needed and operates at peak efficiency to keep your home dry and safe.

Don’t let a minor plumbing issue turn into a major headache—call the Blind & Sons team today.

Need Services?

Massillon Electrical Services Done Right

Electrical work is no place to cut corners. Blind & Sons’ licensed electricians bring top-level expertise to every project, from simple outlet repairs to full panel upgrades. Our Massillon electrical services include:

Our electricians arrive with fully stocked vehicles and solve most issues the same day.

Indoor Air Quality Services for a Healthier Massillon Home

Breathing clean, pollutant-free air indoors is vital for your health—especially for those with asthma or allergies. Our indoor air quality experts assess and improve the air in your home using proven techniques and products.

Ask about our full indoor air quality evaluation for your Massillon home.

Air Conditioning Services for Massillon Summers

Heat pump unit outside a brick building

With temperatures rising in recent years, it’s more important than ever to have an efficient and reliable cooling system. Blind & Sons provides complete AC services for homeowners throughout Massillon.

Through our Maintenance Value Plan, you’ll get exclusive access to priority service, repair discounts, and seasonal tune-ups.

Heating Services for Massillon’s Cold Winters

When the snow piles up in Massillon, you need a heating system that won’t let you down. Blind & Sons is equipped to handle all your heating needs—whether you’re staying warm with a gas furnace or looking to upgrade to a heat pump.

Our team is trained to recommend the best heating options based on your home’s layout and budget.

Need Services?

Why Massillon Homeowners Trust Blind & Sons

With over 85 years of serving the community, Blind & Sons continues to lead the way in quality, responsiveness, and long-term reliability. We’re not just experts—we’re your neighbors.

Benefits of choosing Blind & Sons include:

  • HVAC emergency services with no overtime charges
  • 100% satisfaction guaranteed on all repairs and installations
  • Licensed, background-checked, and extensively trained technicians
  • Straightforward, honest pricing with no surprise fees
  • Exclusive Maintenance Value Plan with tune-ups and discounts

We know the homes of Massillon—from classic two-stories to newer developments—and tailor our service to match the unique needs of every property.

Book Your HVAC, Plumbing & Electrical Service in Massillon Today

Whether you’re upgrading your heating system, troubleshooting a flickering light, or dealing with a leaky faucet, Blind & Sons is the name Massillon families trust for comprehensive and dependable service.

Call 330-362-9232 or contact us online now to schedule your service appointment in Massillon, OH!

 

Recent Jobs and Reviews in Massillon, OH

Massillon, OH at a glance

Blind and Sons has completed 20 jobs in Massillon, OH in July 2026.

The most recent job was on July 28, 2026.

Blind and Sons has completed 460 jobs in Massillon, OH in the last 12 months.

Job Locations and Reviews

Completed comprehensive preventive maintenance tune-up on a 10-year-old Trane air conditioning system. Performed full system inspection including electrical connections, capacitor testing, refrigerant line evaluation, and condenser unit examination. All components found operating within normal parameters with no issues identified; unit cleared for continued service.
Completed comprehensive preventive maintenance tune-up on a 10-year-old Trane air conditioning system. Performed full system inspection including electrical connections, capacitor testing, refrigerant line evaluation, and condenser unit examination. All components found operating within normal parameters with no issues identified; unit cleared for continued service.
Taylor F.
Taylor F. Checked in
Completed comprehensive preventive maintenance tune-up on a 10-year-old Trane air conditioning system. Performed full system inspection including electrical connections, capacitor testing, refrigerant line evaluation, and condenser unit examination. All components found operating within normal parameters with no issues identified; unit cleared for continued service.
Massillon, OH 44647
Replaced defective shower valve assembly in bathroom shower enclosure. Installed new valve control with trim plate and lever handle, connecting to existing copper supply lines. Completed installation and tested for proper operation and leak-free performance. Homeowner advised that drywall repair resulting from valve access is not included in scope of work.
Replaced defective shower valve assembly in bathroom shower enclosure. Installed new valve control with trim plate and lever handle, connecting to existing copper supply lines. Completed installation and tested for proper operation and leak-free performance. Homeowner advised that drywall repair resulting from valve access is not included in scope of work.
David K.
David K. Checked in
Replaced defective shower valve assembly in bathroom shower enclosure. Installed new valve control with trim plate and lever handle, connecting to existing copper supply lines. Completed installation and tested for proper operation and leak-free performance. Homeowner advised that drywall repair resulting from valve access is not included in scope of work.
Massillon, OH 44646
Responded to service call for leaking under kitchen sink. Upon inspection, identified loose tailpiece connections and cracked PVC piping in the P-trap assembly of double-sink drainage system. Tightened all threaded connections at basket strainers and tailpieces. Replaced damaged sections of white PVC drain pipe and P-trap components. Verified all supply line connections at shut-off valves were secure with no leaks present. Tested both drains under full water flow to confirm proper drainage and verified all connections remained dry and leak-free.
Responded to service call for leaking under kitchen sink. Upon inspection, identified loose tailpiece connections and cracked PVC piping in the P-trap assembly of double-sink drainage system. Tightened all threaded connections at basket strainers and tailpieces. Replaced damaged sections of white PVC drain pipe and P-trap components. Verified all supply line connections at shut-off valves were secure with no leaks present. Tested both drains under full water flow to confirm proper drainage and verified all connections remained dry and leak-free.
Karl M.
Karl M. Checked in
Responded to service call for leaking under kitchen sink. Upon inspection, identified loose tailpiece connections and cracked PVC piping in the P-trap assembly of double-sink drainage system. Tightened all threaded connections at basket strainers and tailpieces. Replaced damaged sections of white PVC drain pipe and P-trap components. Verified all supply line connections at shut-off valves were secure with no leaks present. Tested both drains under full water flow to confirm proper drainage and verified all connections remained dry and leak-free.
Massillon, OH 44646
Completed MVP recurring cooling maintenance visit on residential HVAC system. Performed comprehensive inspection of indoor furnace unit in basement and outdoor condensing unit, verified proper operation of all components, checked refrigerant line connections, and confirmed system is functioning within normal parameters. Equipment showed no visible signs of damage or operational issues, with proper clearances maintained and professional installation standards observed throughout.
Completed MVP recurring cooling maintenance visit on residential HVAC system. Performed comprehensive inspection of indoor furnace unit in basement and outdoor condensing unit, verified proper operation of all components, checked refrigerant line connections, and confirmed system is functioning within normal parameters. Equipment showed no visible signs of damage or operational issues, with proper clearances maintained and professional installation standards observed throughout.
William S.
William S. Checked in
Completed MVP recurring cooling maintenance visit on residential HVAC system. Performed comprehensive inspection of indoor furnace unit in basement and outdoor condensing unit, verified proper operation of all components, checked refrigerant line connections, and confirmed system is functioning within normal parameters. Equipment showed no visible signs of damage or operational issues, with proper clearances maintained and professional installation standards observed throughout.
Massillon, OH 44646
Completed MVP recurring cooling maintenance visit on residential HVAC system. Performed comprehensive inspection of Amana furnace unit and associated components including air distribution system, curved louver diffuser assembly, PVC intake/exhaust piping, and flexible ductwork connections. All system components found to be in good operating condition with no visible signs of deterioration, damage, or required repairs. Documentation photos captured for service records.
Completed MVP recurring cooling maintenance visit on residential HVAC system. Performed comprehensive inspection of Amana furnace unit and associated components including air distribution system, curved louver diffuser assembly, PVC intake/exhaust piping, and flexible ductwork connections. All system components found to be in good operating condition with no visible signs of deterioration, damage, or required repairs. Documentation photos captured for service records.
Derrick M.
Derrick M. Checked in
Completed MVP recurring cooling maintenance visit on residential HVAC system. Performed comprehensive inspection of Amana furnace unit and associated components including air distribution system, curved louver diffuser assembly, PVC intake/exhaust piping, and flexible ductwork connections. All system components found to be in good operating condition with no visible signs of deterioration, damage, or required repairs. Documentation photos captured for service records.
Massillon, OH 44646
# HVAC Install - Complete System

Completed installation of a 90% efficiency furnace and air conditioning system. Installed a Lennox 3-ton air conditioning unit (Model E16KC1-036-230A03) with R-454B refrigerant, manufactured June 2026, rated for 208/230V single-phase operation. Unit specifications include compressor RLA of 16.7 amps and total refrigerant charge of 7 lbs 6 oz. Verified proper electrical connections and installed 30-amp Littelfuse fuses in disconnect housing for overcurrent protection. Connected refrigerant lines with appropriate service ports and secured all electrical wiring per manufacturer specifications and local code requirements. System tested and operational, meeting AHRI certification standards with IPX4 weather resistance rating.
# HVAC Install - Complete System

Completed installation of a 90% efficiency furnace and air conditioning system. Installed a Lennox 3-ton air conditioning unit (Model E16KC1-036-230A03) with R-454B refrigerant, manufactured June 2026, rated for 208/230V single-phase operation. Unit specifications include compressor RLA of 16.7 amps and total refrigerant charge of 7 lbs 6 oz. Verified proper electrical connections and installed 30-amp Littelfuse fuses in disconnect housing for overcurrent protection. Connected refrigerant lines with appropriate service ports and secured all electrical wiring per manufacturer specifications and local code requirements. System tested and operational, meeting AHRI certification standards with IPX4 weather resistance rating.
Austin B.
Austin B. Checked in
# HVAC Install - Complete System Completed installation of a 90% efficiency furnace and air conditioning system. Installed a Lennox 3-ton air conditioning unit (Model E16KC1-036-230A03) with R-454B refrigerant, manufactured June 2026, rated for 208/230V single-phase operation. Unit specifications include compressor RLA of 16.7 amps and total refrigerant charge of 7 lbs 6 oz. Verified proper electrical connections and installed 30-amp Littelfuse fuses in disconnect housing for overcurrent protection. Connected refrigerant lines with appropriate service ports and secured all electrical wiring per manufacturer specifications and local code requirements. System tested and operational, meeting AHRI certification standards with IPX4 weather resistance rating.
Massillon, OH 44646
Completed comprehensive estimate for replacement of existing residential heating and cooling system. Assessed current Conquest 80 furnace installation in basement utility area along with outdoor condensing unit, documenting equipment conditions, ductwork configuration, and existing infrastructure including PVC condensate drainage, electrical connections, and supply/return plenum arrangements. Provided homeowner with replacement options and recommendations for updated HVAC system to improve efficiency and reliability.
Completed comprehensive estimate for replacement of existing residential heating and cooling system. Assessed current Conquest 80 furnace installation in basement utility area along with outdoor condensing unit, documenting equipment conditions, ductwork configuration, and existing infrastructure including PVC condensate drainage, electrical connections, and supply/return plenum arrangements. Provided homeowner with replacement options and recommendations for updated HVAC system to improve efficiency and reliability.
Dave T.
Dave T. Checked in
Completed comprehensive estimate for replacement of existing residential heating and cooling system. Assessed current Conquest 80 furnace installation in basement utility area along with outdoor condensing unit, documenting equipment conditions, ductwork configuration, and existing infrastructure including PVC condensate drainage, electrical connections, and supply/return plenum arrangements. Provided homeowner with replacement options and recommendations for updated HVAC system to improve efficiency and reliability.
Massillon, OH 44646
Completed comprehensive tune-up service on 11-year-old air conditioning system, including inspection of control board components, electrical connections, and outdoor condenser unit. Accessed and photographed interior control board showing all wiring harnesses, connectors, and circuit components in proper working condition. Removed outdoor unit access panel to inspect compressor motor, fan assembly, condenser coils, and verified all internal components operational with no visible damage or deterioration noted.
Completed comprehensive tune-up service on 11-year-old air conditioning system, including inspection of control board components, electrical connections, and outdoor condenser unit. Accessed and photographed interior control board showing all wiring harnesses, connectors, and circuit components in proper working condition. Removed outdoor unit access panel to inspect compressor motor, fan assembly, condenser coils, and verified all internal components operational with no visible damage or deterioration noted.
Manager S.
Manager S. Checked in
Completed comprehensive tune-up service on 11-year-old air conditioning system, including inspection of control board components, electrical connections, and outdoor condenser unit. Accessed and photographed interior control board showing all wiring harnesses, connectors, and circuit components in proper working condition. Removed outdoor unit access panel to inspect compressor motor, fan assembly, condenser coils, and verified all internal components operational with no visible damage or deterioration noted.
Massillon, OH 44646
# Plumbing Service Report

Responded to service call at group home facility for two clogged bathroom sinks. Upon inspection, found white porcelain Jacuzzi bathroom sinks with chrome two-handle faucets experiencing drainage issues. Cleared obstructions from both sink drain lines using appropriate drain cleaning equipment and techniques. Inspected accessible plumbing connections beneath sinks, noting existing corrosion and mineral deposits on visible piping, though these pre-existing conditions did not impact the immediate drainage repair. Tested water flow and drainage in both bathroom sinks after clearing blockages, confirming proper function and adequate drainage speed. Both sinks now draining properly with no standing water or slow drainage issues remaining.
# Plumbing Service Report

Responded to service call at group home facility for two clogged bathroom sinks. Upon inspection, found white porcelain Jacuzzi bathroom sinks with chrome two-handle faucets experiencing drainage issues. Cleared obstructions from both sink drain lines using appropriate drain cleaning equipment and techniques. Inspected accessible plumbing connections beneath sinks, noting existing corrosion and mineral deposits on visible piping, though these pre-existing conditions did not impact the immediate drainage repair. Tested water flow and drainage in both bathroom sinks after clearing blockages, confirming proper function and adequate drainage speed. Both sinks now draining properly with no standing water or slow drainage issues remaining.
Denny J.
Denny J. Checked in
# Plumbing Service Report Responded to service call at group home facility for two clogged bathroom sinks. Upon inspection, found white porcelain Jacuzzi bathroom sinks with chrome two-handle faucets experiencing drainage issues. Cleared obstructions from both sink drain lines using appropriate drain cleaning equipment and techniques. Inspected accessible plumbing connections beneath sinks, noting existing corrosion and mineral deposits on visible piping, though these pre-existing conditions did not impact the immediate drainage repair. Tested water flow and drainage in both bathroom sinks after clearing blockages, confirming proper function and adequate drainage speed. Both sinks now draining properly with no standing water or slow drainage issues remaining.
Massillon, OH 44647
Massillon, OH - Installed customer-supplied Delta shower valve and mixing control on existing tiled bathroom wall. Mounted single-handle valve assembly with circular face plate, ensuring proper alignment and secure attachment to wall substrate, and verified operational functionality of temperature control mechanism.
James P.
James P. Checked in
Installed customer-supplied Delta shower valve and mixing control on existing tiled bathroom wall. Mounted single-handle valve assembly with circular face plate, ensuring proper alignment and secure attachment to wall substrate, and verified operational functionality of temperature control mechanism.
Massillon, OH 44646
Completed comprehensive electrical assessment of residential property undergoing major renovation with extensive structural exposure. Evaluated existing electrical infrastructure in main living area and addition requiring complete rewire. Inspected exposed floor joists, ceiling cavities with missing drywall sections, and wall framing stripped to studs to determine optimal routing paths for new electrical circuits. Assessed requirements for updated service panel capacity, branch circuit distribution, lighting fixtures including existing recessed ceiling lights, and outlet placement throughout renovated spaces. Documented conditions of exposed brick masonry, deteriorated wall surfaces, and structural elements to coordinate electrical rough-in with ongoing construction phases. Provided detailed estimate for complete home rewiring including addition wiring installation, accounting for exposed joists and open wall cavities that will facilitate new wire runs before finish work commences.
Completed comprehensive electrical assessment of residential property undergoing major renovation with extensive structural exposure. Evaluated existing electrical infrastructure in main living area and addition requiring complete rewire. Inspected exposed floor joists, ceiling cavities with missing drywall sections, and wall framing stripped to studs to determine optimal routing paths for new electrical circuits. Assessed requirements for updated service panel capacity, branch circuit distribution, lighting fixtures including existing recessed ceiling lights, and outlet placement throughout renovated spaces. Documented conditions of exposed brick masonry, deteriorated wall surfaces, and structural elements to coordinate electrical rough-in with ongoing construction phases. Provided detailed estimate for complete home rewiring including addition wiring installation, accounting for exposed joists and open wall cavities that will facilitate new wire runs before finish work commences.
Landon M.
Landon M. Checked in
Completed comprehensive electrical assessment of residential property undergoing major renovation with extensive structural exposure. Evaluated existing electrical infrastructure in main living area and addition requiring complete rewire. Inspected exposed floor joists, ceiling cavities with missing drywall sections, and wall framing stripped to studs to determine optimal routing paths for new electrical circuits. Assessed requirements for updated service panel capacity, branch circuit distribution, lighting fixtures including existing recessed ceiling lights, and outlet placement throughout renovated spaces. Documented conditions of exposed brick masonry, deteriorated wall surfaces, and structural elements to coordinate electrical rough-in with ongoing construction phases. Provided detailed estimate for complete home rewiring including addition wiring installation, accounting for exposed joists and open wall cavities that will facilitate new wire runs before finish work commences.
Massillon, OH 44647
Conducted a comprehensive evaluation of the existing electrical service to provide a second opinion estimate for installing an additional subpanel to serve a garage. Assessment included examining the main service panel, available breaker spaces, and current electrical load to determine feasibility of adding a new 100-amp or larger subpanel with capacity for two 40-amp circuit breakers. Evaluated the exterior electrical service equipment, meter base, and existing conduit routing to establish the most practical installation path. Reviewed the service entrance conductors and main disconnect to confirm adequate capacity for the proposed subpanel addition. Documented the current electrical infrastructure including the exterior panel locations, conduit runs, and available mounting surfaces on the building exterior. Photographed existing utility connections, weatherproof enclosures, and potential routing paths for new feeder conductors from the main service to the proposed garage subpanel loc
Conducted a comprehensive evaluation of the existing electrical service to provide a second opinion estimate for installing an additional subpanel to serve a garage. Assessment included examining the main service panel, available breaker spaces, and current electrical load to determine feasibility of adding a new 100-amp or larger subpanel with capacity for two 40-amp circuit breakers. Evaluated the exterior electrical service equipment, meter base, and existing conduit routing to establish the most practical installation path. Reviewed the service entrance conductors and main disconnect to confirm adequate capacity for the proposed subpanel addition. Documented the current electrical infrastructure including the exterior panel locations, conduit runs, and available mounting surfaces on the building exterior. Photographed existing utility connections, weatherproof enclosures, and potential routing paths for new feeder conductors from the main service to the proposed garage subpanel loc
Landon M.
Landon M. Checked in
Conducted a comprehensive evaluation of the existing electrical service to provide a second opinion estimate for installing an additional subpanel to serve a garage. Assessment included examining the main service panel, available breaker spaces, and current electrical load to determine feasibility of adding a new 100-amp or larger subpanel with capacity for two 40-amp circuit breakers. Evaluated the exterior electrical service equipment, meter base, and existing conduit routing to establish the most practical installation path. Reviewed the service entrance conductors and main disconnect to confirm adequate capacity for the proposed subpanel addition. Documented the current electrical infrastructure including the exterior panel locations, conduit runs, and available mounting surfaces on the building exterior. Photographed existing utility connections, weatherproof enclosures, and potential routing paths for new feeder conductors from the main service to the proposed garage subpanel loc
Massillon, OH 44646
Installed new AC circuit with proper wiring and conduit routing in attic space. Work included mounting electrical panel with dual-row circuit breaker configuration, running metallic and flexible conduit from panel to equipment location, and completing all necessary connections per code requirements for dedicated air conditioning power supply.
Installed new AC circuit with proper wiring and conduit routing in attic space. Work included mounting electrical panel with dual-row circuit breaker configuration, running metallic and flexible conduit from panel to equipment location, and completing all necessary connections per code requirements for dedicated air conditioning power supply.
Matthew H.
Matthew H. Checked in
Installed new AC circuit with proper wiring and conduit routing in attic space. Work included mounting electrical panel with dual-row circuit breaker configuration, running metallic and flexible conduit from panel to equipment location, and completing all necessary connections per code requirements for dedicated air conditioning power supply.
Massillon, OH 44646
Conducted on-site assessment for whole house generator installation at a 2100 square foot ranch home constructed in 1998. Evaluated electrical service panel capacity, existing utility connections, and potential generator placement locations. Documented current electrical infrastructure including basement wiring configurations and available space for transfer switch installation. Photographed proposed installation areas and existing electrical components to develop comprehensive pricing estimate for complete standby generator system with automatic transfer switch capability.
Conducted on-site assessment for whole house generator installation at a 2100 square foot ranch home constructed in 1998. Evaluated electrical service panel capacity, existing utility connections, and potential generator placement locations. Documented current electrical infrastructure including basement wiring configurations and available space for transfer switch installation. Photographed proposed installation areas and existing electrical components to develop comprehensive pricing estimate for complete standby generator system with automatic transfer switch capability.
Eric L.
Eric L. Checked in
Conducted on-site assessment for whole house generator installation at a 2100 square foot ranch home constructed in 1998. Evaluated electrical service panel capacity, existing utility connections, and potential generator placement locations. Documented current electrical infrastructure including basement wiring configurations and available space for transfer switch installation. Photographed proposed installation areas and existing electrical components to develop comprehensive pricing estimate for complete standby generator system with automatic transfer switch capability.
Massillon, OH 44646
Responded to major water leak originating from furnace coil. Upon arrival, inspected HVAC unit and confirmed active leak from evaporator coil causing water damage to surrounding area. Documented equipment condition and leak source with photos showing affected cabinet panels and drainage components.
Responded to major water leak originating from furnace coil. Upon arrival, inspected HVAC unit and confirmed active leak from evaporator coil causing water damage to surrounding area. Documented equipment condition and leak source with photos showing affected cabinet panels and drainage components.
William S.
William S. Checked in
Responded to major water leak originating from furnace coil. Upon arrival, inspected HVAC unit and confirmed active leak from evaporator coil causing water damage to surrounding area. Documented equipment condition and leak source with photos showing affected cabinet panels and drainage components.
Massillon, OH 44646
Massillon, OH - Responded to no cooling complaint at residential property. Upon arrival, inspected outdoor condenser unit and found system operational with no visible defects or mechanical issues. Unit running normally with proper airflow through coils and fan operation confirmed.
William S.
William S. Checked in
Responded to no cooling complaint at residential property. Upon arrival, inspected outdoor condenser unit and found system operational with no visible defects or mechanical issues. Unit running normally with proper airflow through coils and fan operation confirmed.
Massillon, OH 44646
Massillon, OH - Replaced failed bar sink faucet that had frozen and split the plastic components. Ordered replacement parts, which arrived at shop the following day, and completed installation of new chrome two-handle faucet assembly on stainless steel drop-in sink.
Travis B.
Travis B. Checked in
Replaced failed bar sink faucet that had frozen and split the plastic components. Ordered replacement parts, which arrived at shop the following day, and completed installation of new chrome two-handle faucet assembly on stainless steel drop-in sink.
Massillon, OH 44646
Massillon, OH - Responded to service call for installation of dedicated electrical outlet for newly installed tankless water heater. Assessed existing electrical panel capacity and circuit availability, identified appropriate breaker location, and provided estimate for running dedicated circuit with proper amperage rating to support tankless water heater electrical requirements within requested timeframe.
Steven M.
Steven M. Checked in
Responded to service call for installation of dedicated electrical outlet for newly installed tankless water heater. Assessed existing electrical panel capacity and circuit availability, identified appropriate breaker location, and provided estimate for running dedicated circuit with proper amperage rating to support tankless water heater electrical requirements within requested timeframe.
Massillon, OH 44646
Responded to no-cooling complaint on 12-year-old outdoor air conditioning unit. Upon arrival, found contactor assembly and capacitor heavily covered in cobwebs and debris, indicating lack of recent maintenance. Inspected electrical connections and found aged, worn wiring throughout the unit. Observed 45/5µF dual-run capacitor rated at 370V AC with multiple wire connections. Cleaned contactor assembly and surrounding electrical components, removing extensive spider web accumulation from relay contacts, terminals, and wiring connections. Verified all wire connections were secure at contactor and capacitor terminals. Tested contactor operation and capacitor functionality. System restored to proper cooling operation following cleaning and inspection of electrical components.
Responded to no-cooling complaint on 12-year-old outdoor air conditioning unit. Upon arrival, found contactor assembly and capacitor heavily covered in cobwebs and debris, indicating lack of recent maintenance. Inspected electrical connections and found aged, worn wiring throughout the unit. Observed 45/5µF dual-run capacitor rated at 370V AC with multiple wire connections. Cleaned contactor assembly and surrounding electrical components, removing extensive spider web accumulation from relay contacts, terminals, and wiring connections. Verified all wire connections were secure at contactor and capacitor terminals. Tested contactor operation and capacitor functionality. System restored to proper cooling operation following cleaning and inspection of electrical components.
Daniel S.
Daniel S. Checked in
Responded to no-cooling complaint on 12-year-old outdoor air conditioning unit. Upon arrival, found contactor assembly and capacitor heavily covered in cobwebs and debris, indicating lack of recent maintenance. Inspected electrical connections and found aged, worn wiring throughout the unit. Observed 45/5µF dual-run capacitor rated at 370V AC with multiple wire connections. Cleaned contactor assembly and surrounding electrical components, removing extensive spider web accumulation from relay contacts, terminals, and wiring connections. Verified all wire connections were secure at contactor and capacitor terminals. Tested contactor operation and capacitor functionality. System restored to proper cooling operation following cleaning and inspection of electrical components.
Massillon, OH 44646
Massillon, OH - Completed first-time air conditioning and evaporator coil installation at residential property. Installed new dual-fuse disconnect block with FLNR-rated fuses and established proper electrical connections to outdoor condensing unit, ensuring all wiring met code requirements and manufacturer specifications.
Charles A.
Charles A. Checked in
Completed first-time air conditioning and evaporator coil installation at residential property. Installed new dual-fuse disconnect block with FLNR-rated fuses and established proper electrical connections to outdoor condensing unit, ensuring all wiring met code requirements and manufacturer specifications.
Massillon, OH 44646

 

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image