Schedule Service

Trusted HVAC, Plumbing & Electrical Services in Medina, OH

An old air conditioning unit that needs to replacing.

Since 1937, Blind & Sons has proudly served Medina, OH homeowners with expert HVAC, plumbing, and electrical services. Our licensed and highly trained team is committed to delivering top-notch service backed by a 100% satisfaction guarantee. From heating and cooling repairs to plumbing installations and electrical inspections, we offer comprehensive home services in Medina that ensure your home stays comfortable, safe, and efficient all year long.

Need trusted local service in Medina? Call Blind & Sons at 330-362-9232 or contact us online to schedule an appointment today.

Serving the Heart of Medina County

Situated in the center of Medina County, Medina, OH combines rich history with modern living. The city is known for its beautifully preserved 19th-century architecture, tree-lined streets, and the bustling charm of Medina Square, where local shops, restaurants, and community events create a vibrant hub for residents and visitors alike. From historic homes on Broadway Street to newer developments in neighborhoods like Blue Heron and Fox Meadow, Medina offers diverse living options that require equally diverse home services.

At Blind & Sons, we take pride in being part of this growing and thriving community. We understand the specific challenges homeowners face in Medina—from aging infrastructure and evolving energy efficiency standards to the seasonal temperature swings that demand reliable HVAC systems. Our technicians live and work locally, giving them unique insight into the needs of Medina homes. Whether you’re upgrading an older home or maintaining a modern one, we deliver custom solutions built on trust, local expertise, and long-standing commitment to the region.

Complete Heating Services in Medina, OH

When snow blankets the streets of Medina and temperatures drop below freezing, having a reliable heating system is more than just comfort—it’s a necessity. At Blind & Sons, we specialize in full-service heating solutions designed specifically for the needs of Medina homes. Whether you live in a century-old colonial near Medina Square or a modern build on the outskirts, our team ensures your home stays warm and safe when it matters most:

Need Services?

Air Conditioning Services to Keep Medina Homes Cool

Summer days in Medina can go from pleasant to sweltering quickly. That’s why so many homeowners throughout the area—from the tree-lined streets near Medina Square to newer subdivisions like Windfall Estates—count on Blind & Sons to keep their homes cool and energy-efficient. Our expert Medina cooling services are built with those local details in mind, ensuring each system we service is tailored to perform at its best:

  • AC Repairs: Fast service for issues like warm airflow, refrigerant leaks, or noisy operation.
  • New AC Installations: We’ll help you choose the right system and install it to manufacturer standards.
  • AC Replacements: Upgrade to a more energy-efficient model that better serves your cooling needs.
  • AC Maintenance: Regular servicing to ensure performance, improve efficiency, and reduce long-term costs.
  • Heat Pumps & Ductless Mini-Splits: Ideal for zoned cooling or homes without existing ductwork.
  • Emergency AC Repair: Immediate support for system failures during extreme heat.

Indoor Air Quality Services in Medina, OH

Poor indoor air can lead to allergy flare-ups, respiratory issues, and discomfort. Blind & Sons helps you breathe easier with professional IAQ services:

Our solutions are customized to match your home’s layout and your family’s health needs.

Expert Electrical Services in Medina for Safe, Reliable Power

Young electrical technician writes in a notebook the data collected on a residential electric panel

From the kitchen appliances that fuel your mornings to the smart devices that keep you connected, electrical systems are the hidden backbone of modern living in Medina. Whether you’re updating an older home near Medina’s historic district or building a new one in a growing development, our team ensures your electrical systems are efficient, safe, and built to last. We keep your home powered and protected with:

Need Services?

Full-Service Plumbing in Medina, OH

Whether it’s a slow leak or a major plumbing emergency, Blind & Sons provides fast, effective plumbing services across Medina. We offer:

Why Choose Blind & Sons in Medina, OH?

Blind & Sons has earned the trust of Medina families for generations. Here’s what sets us apart:

  • Emergency HVAC Service: We’re here for you when you need us.
  • Licensed, Background-Checked Technicians: Skilled, respectful professionals in every home.
  • MVP Maintenance Program: Preventative care plans that save money and extend system life.
  • Flexible Financing & Online Scheduling: Convenience at your fingertips.
  • Referral Rewards & Special Offers: Save more while sharing our services.
  • 100% Satisfaction Guarantee: We’re not satisfied until you are.

Whether you’re near Medina Square, in the Heritage Woods neighborhood, or anywhere else in the city, we’re your local partner for total home comfort.

Schedule HVAC, Plumbing, or Electrical Services in Medina Today

When it comes to your home, there’s no room for guesswork. Trust the team at Blind & Sons for reliable service that delivers real value. We proudly serve Medina and surrounding areas with professionalism, transparency, and top-tier customer care.

Call 330-362-9232 or contact us online to book HVAC, plumbing, electrical, or indoor air quality services in Medina, OH today.

 

Recent Jobs and Reviews in Medina, OH

Medina, OH at a glance

Blind and Sons has completed 20 jobs in Medina, OH in October 2026.

The most recent job was on October 15, 2026.

Blind and Sons has completed 746 jobs in Medina, OH in the last 12 months.

Job Locations and Reviews

Installed a new code-approved shut-off valve on the cold water supply line nearest the refrigerator and ran a stainless steel braided supply line to the appliance, replacing the existing saddle valve. Capped off the obsolete saddle valve connection, then pressurized the line and inspected all connections, confirming no leaks.
Installed a new code-approved shut-off valve on the cold water supply line nearest the refrigerator and ran a stainless steel braided supply line to the appliance, replacing the existing saddle valve. Capped off the obsolete saddle valve connection, then pressurized the line and inspected all connections, confirming no leaks.
Mark W.
Mark W. Checked in
Installed a new code-approved shut-off valve on the cold water supply line nearest the refrigerator and ran a stainless steel braided supply line to the appliance, replacing the existing saddle valve. Capped off the obsolete saddle valve connection, then pressurized the line and inspected all connections, confirming no leaks.
Medina, OH 44256
Performed a scheduled heating maintenance visit, inspecting the furnace control board wiring and neutral connections and finding no signs of damage, corrosion, or overheating. Used a clamp meter to perform electrical diagnostics at the gas valve and wiring harness area, with no visible deficiencies noted in the cabinet interior.
Performed a scheduled heating maintenance visit, inspecting the furnace control board wiring and neutral connections and finding no signs of damage, corrosion, or overheating. Used a clamp meter to perform electrical diagnostics at the gas valve and wiring harness area, with no visible deficiencies noted in the cabinet interior.
Matthew F.
Matthew F. Checked in
Performed a scheduled heating maintenance visit, inspecting the furnace control board wiring and neutral connections and finding no signs of damage, corrosion, or overheating. Used a clamp meter to perform electrical diagnostics at the gas valve and wiring harness area, with no visible deficiencies noted in the cabinet interior.
Medina, OH 44256
Performed annual maintenance on a 26-year-old gas furnace, inspecting the burner assembly, heat exchanger inlets, gas valve and manifold, inducer motor, flame sensor, and control wiring. Noted surface corrosion and staining in the burner compartment and cleaned debris from the cabinet and burner area. Per the customer's note, the two front-door buttons were tested, with one operating and one not; the nonfunctioning button is recommended for further diagnosis and repair.
Performed annual maintenance on a 26-year-old gas furnace, inspecting the burner assembly, heat exchanger inlets, gas valve and manifold, inducer motor, flame sensor, and control wiring. Noted surface corrosion and staining in the burner compartment and cleaned debris from the cabinet and burner area. Per the customer's note, the two front-door buttons were tested, with one operating and one not; the nonfunctioning button is recommended for further diagnosis and repair.
Jibreel H.
Jibreel H. Checked in
Performed annual maintenance on a 26-year-old gas furnace, inspecting the burner assembly, heat exchanger inlets, gas valve and manifold, inducer motor, flame sensor, and control wiring. Noted surface corrosion and staining in the burner compartment and cleaned debris from the cabinet and burner area. Per the customer's note, the two front-door buttons were tested, with one operating and one not; the nonfunctioning button is recommended for further diagnosis and repair.
Medina, OH 44256
Performed scheduled heating maintenance, inspecting the system's filter media and blower assembly and documenting their condition. Observed dust and lint accumulation on the filter mesh and across the blower wheel blades and housing, which can restrict airflow and reduce heating efficiency. Verified the blower wheel, motor shaft, and hub were intact and in serviceable condition.
Performed scheduled heating maintenance, inspecting the system's filter media and blower assembly and documenting their condition. Observed dust and lint accumulation on the filter mesh and across the blower wheel blades and housing, which can restrict airflow and reduce heating efficiency. Verified the blower wheel, motor shaft, and hub were intact and in serviceable condition.
Kevin D.
Kevin D. Checked in
Performed scheduled heating maintenance, inspecting the system's filter media and blower assembly and documenting their condition. Observed dust and lint accumulation on the filter mesh and across the blower wheel blades and housing, which can restrict airflow and reduce heating efficiency. Verified the blower wheel, motor shaft, and hub were intact and in serviceable condition.
Medina, OH 44256
Performed annual heating maintenance on the gas furnace, including inspection of the draft inducer assembly, pressure switches, gas valve, and vent transition, and verified gas pressure and draft readings with a dual-port digital manometer. Inspected and cleaned the flame sensor and checked the integrated control board and wiring harness for proper connections, with no damage observed. Noted light surface rust and dust accumulation on the cabinet interior and corrosion on a copper line, which should be monitored at future visits.
Performed annual heating maintenance on the gas furnace, including inspection of the draft inducer assembly, pressure switches, gas valve, and vent transition, and verified gas pressure and draft readings with a dual-port digital manometer. Inspected and cleaned the flame sensor and checked the integrated control board and wiring harness for proper connections, with no damage observed. Noted light surface rust and dust accumulation on the cabinet interior and corrosion on a copper line, which should be monitored at future visits.
Matthew F.
Matthew F. Checked in
Performed annual heating maintenance on the gas furnace, including inspection of the draft inducer assembly, pressure switches, gas valve, and vent transition, and verified gas pressure and draft readings with a dual-port digital manometer. Inspected and cleaned the flame sensor and checked the integrated control board and wiring harness for proper connections, with no damage observed. Noted light surface rust and dust accumulation on the cabinet interior and corrosion on a copper line, which should be monitored at future visits.
Medina, OH 44256
Performed annual furnace maintenance on a 1-year-old gas furnace, including inspection of the control compartment, wiring harness, circuit board connections, gas valve, and gas piping. Removed and inspected the flame sensor, and cleaned light dust and debris from the cabinet interior. Noted unterminated wire ends in the control compartment, and found no signs of rust, frost, or component breakage.
Performed annual furnace maintenance on a 1-year-old gas furnace, including inspection of the control compartment, wiring harness, circuit board connections, gas valve, and gas piping. Removed and inspected the flame sensor, and cleaned light dust and debris from the cabinet interior. Noted unterminated wire ends in the control compartment, and found no signs of rust, frost, or component breakage.
Kevin D.
Kevin D. Checked in
Performed annual furnace maintenance on a 1-year-old gas furnace, including inspection of the control compartment, wiring harness, circuit board connections, gas valve, and gas piping. Removed and inspected the flame sensor, and cleaned light dust and debris from the cabinet interior. Noted unterminated wire ends in the control compartment, and found no signs of rust, frost, or component breakage.
Medina, OH 44256
Performed scheduled heating maintenance on the gas furnace, including inspection of the gas valve assembly, pressure switch, wiring connections, and condensate/venting components. Verified gas pressure and system pressure readings using a digital dual-port manometer, with all components found in good working condition and no visible corrosion, damage, or abnormalities noted.
Performed scheduled heating maintenance on the gas furnace, including inspection of the gas valve assembly, pressure switch, wiring connections, and condensate/venting components. Verified gas pressure and system pressure readings using a digital dual-port manometer, with all components found in good working condition and no visible corrosion, damage, or abnormalities noted.
Matthew F.
Matthew F. Checked in
Performed scheduled heating maintenance on the gas furnace, including inspection of the gas valve assembly, pressure switch, wiring connections, and condensate/venting components. Verified gas pressure and system pressure readings using a digital dual-port manometer, with all components found in good working condition and no visible corrosion, damage, or abnormalities noted.
Medina, OH 44256
Performed recurring cooling maintenance, inspecting the furnace's internal components including the gas valve assembly, inducer motor, and wiring harness with the upper access panel removed. Replaced the pleated air filter and checked the condensate drain line, noting rust staining around the floor drain and PVC piping that may indicate past moisture or drainage issues and should be monitored.
Performed recurring cooling maintenance, inspecting the furnace's internal components including the gas valve assembly, inducer motor, and wiring harness with the upper access panel removed. Replaced the pleated air filter and checked the condensate drain line, noting rust staining around the floor drain and PVC piping that may indicate past moisture or drainage issues and should be monitored.
Kevin D.
Kevin D. Checked in
Performed recurring cooling maintenance, inspecting the furnace's internal components including the gas valve assembly, inducer motor, and wiring harness with the upper access panel removed. Replaced the pleated air filter and checked the condensate drain line, noting rust staining around the floor drain and PVC piping that may indicate past moisture or drainage issues and should be monitored.
Medina, OH 44256
Responded to a service call to evaluate the gas control valve on a gas-fired furnace (Ultra 80). Removed the front access panel and inspected the valve, wiring, gas supply piping, blower assembly, and burner compartment, observing normal burner flame with heavy dust and debris buildup on interior surfaces. Documented the unit's condition with photos and prepared an estimate for gas valve replacement.
Responded to a service call to evaluate the gas control valve on a gas-fired furnace (Ultra 80). Removed the front access panel and inspected the valve, wiring, gas supply piping, blower assembly, and burner compartment, observing normal burner flame with heavy dust and debris buildup on interior surfaces. Documented the unit's condition with photos and prepared an estimate for gas valve replacement.
Jibreel H.
Jibreel H. Checked in
Responded to a service call to evaluate the gas control valve on a gas-fired furnace (Ultra 80). Removed the front access panel and inspected the valve, wiring, gas supply piping, blower assembly, and burner compartment, observing normal burner flame with heavy dust and debris buildup on interior surfaces. Documented the unit's condition with photos and prepared an estimate for gas valve replacement.
Medina, OH 44256
Performed seasonal cooling maintenance on the Lennox high-efficiency furnace and air handler system, inspecting the control board, wiring harness, and electrical connections for signs of damage, burning, or loose terminals, with all components found secure and in good condition. Verified the PVC condensate drain line and vent piping were intact and free of cracks, leaks, or obstructions, and confirmed no frost, rust, or visible damage on the unit or surrounding ductwork and return plenum.
Performed seasonal cooling maintenance on the Lennox high-efficiency furnace and air handler system, inspecting the control board, wiring harness, and electrical connections for signs of damage, burning, or loose terminals, with all components found secure and in good condition. Verified the PVC condensate drain line and vent piping were intact and free of cracks, leaks, or obstructions, and confirmed no frost, rust, or visible damage on the unit or surrounding ductwork and return plenum.
Kevin D.
Kevin D. Checked in
Performed seasonal cooling maintenance on the Lennox high-efficiency furnace and air handler system, inspecting the control board, wiring harness, and electrical connections for signs of damage, burning, or loose terminals, with all components found secure and in good condition. Verified the PVC condensate drain line and vent piping were intact and free of cracks, leaks, or obstructions, and confirmed no frost, rust, or visible damage on the unit or surrounding ductwork and return plenum.
Medina, OH 44256
Performed a comprehensive heating maintenance inspection on a Lennox gas furnace with Aprilaire air handler, verifying condensate drain piping and neutralizer operation and checking flue venting and electrical connections. Inspected the evaporator coil assembly and found frost/mineral buildup on the coil and tubing along with heavy rust-colored staining in the drain pan, and recommended cleaning and further evaluation to ensure proper airflow and drainage.
Performed a comprehensive heating maintenance inspection on a Lennox gas furnace with Aprilaire air handler, verifying condensate drain piping and neutralizer operation and checking flue venting and electrical connections. Inspected the evaporator coil assembly and found frost/mineral buildup on the coil and tubing along with heavy rust-colored staining in the drain pan, and recommended cleaning and further evaluation to ensure proper airflow and drainage.
Taylor F.
Taylor F. Checked in
Performed a comprehensive heating maintenance inspection on a Lennox gas furnace with Aprilaire air handler, verifying condensate drain piping and neutralizer operation and checking flue venting and electrical connections. Inspected the evaporator coil assembly and found frost/mineral buildup on the coil and tubing along with heavy rust-colored staining in the drain pan, and recommended cleaning and further evaluation to ensure proper airflow and drainage.
Medina, OH 44256
Installed a dedicated circuit from the main electrical panel to the garage to serve a new wall-mounted electric unit heater, fishing the wiring through the structure to minimize wall damage. Mounted a disconnect switch at the heater location and connected the unit with a flexible metal conduit whip, leaving the installation secure, properly supported, and ready for operation.
Installed a dedicated circuit from the main electrical panel to the garage to serve a new wall-mounted electric unit heater, fishing the wiring through the structure to minimize wall damage. Mounted a disconnect switch at the heater location and connected the unit with a flexible metal conduit whip, leaving the installation secure, properly supported, and ready for operation.
Matthew H.
Matthew H. Checked in
Installed a dedicated circuit from the main electrical panel to the garage to serve a new wall-mounted electric unit heater, fishing the wiring through the structure to minimize wall damage. Mounted a disconnect switch at the heater location and connected the unit with a flexible metal conduit whip, leaving the installation secure, properly supported, and ready for operation.
Medina, OH 44256
Performed seasonal tune-up on a 2-year-old gas furnace, including inspection of the cabinet and venting. Removed the heavily soiled pleated media filter and replaced it per customer request to restore proper airflow. Inspected and cleaned the flame sensor to remove oxidation buildup and ensure reliable flame proving and ignition.
Performed seasonal tune-up on a 2-year-old gas furnace, including inspection of the cabinet and venting. Removed the heavily soiled pleated media filter and replaced it per customer request to restore proper airflow. Inspected and cleaned the flame sensor to remove oxidation buildup and ensure reliable flame proving and ignition.
Taylor F.
Taylor F. Checked in
Performed seasonal tune-up on a 2-year-old gas furnace, including inspection of the cabinet and venting. Removed the heavily soiled pleated media filter and replaced it per customer request to restore proper airflow. Inspected and cleaned the flame sensor to remove oxidation buildup and ensure reliable flame proving and ignition.
Medina, OH 44256
Completed scheduled MVP heating maintenance on gas furnace system. Performed comprehensive inspection of blower motor assembly, verified all electrical connections and wiring harnesses, and examined control board functionality. All components found operating within normal parameters with no immediate service needs identified.
Completed scheduled MVP heating maintenance on gas furnace system. Performed comprehensive inspection of blower motor assembly, verified all electrical connections and wiring harnesses, and examined control board functionality. All components found operating within normal parameters with no immediate service needs identified.
Matthew F.
Matthew F. Checked in
Completed scheduled MVP heating maintenance on gas furnace system. Performed comprehensive inspection of blower motor assembly, verified all electrical connections and wiring harnesses, and examined control board functionality. All components found operating within normal parameters with no immediate service needs identified.
Medina, OH 44256
Completed installation of 22KW standby generator with 200-amp automatic transfer switch on exterior wall of residence. Ran 20 feet of gas line from existing service point to generator location, coordinated with separate contractor for gas line installation. Installed 15 feet of electrical conduit and wiring from main service panel to new exterior transfer switch panel, mounted all equipment on vinyl siding per manufacturer specifications. Configured automatic transfer switch with proper circuit breaker protection, established all electrical connections to generator unit including control wiring and power cables. Tested system operation including automatic start sequence, transfer switch functionality, and verified proper voltage output under load. All work completed to code requirements with generator positioned for adequate ventilation and service access.
Completed installation of 22KW standby generator with 200-amp automatic transfer switch on exterior wall of residence. Ran 20 feet of gas line from existing service point to generator location, coordinated with separate contractor for gas line installation. Installed 15 feet of electrical conduit and wiring from main service panel to new exterior transfer switch panel, mounted all equipment on vinyl siding per manufacturer specifications. Configured automatic transfer switch with proper circuit breaker protection, established all electrical connections to generator unit including control wiring and power cables. Tested system operation including automatic start sequence, transfer switch functionality, and verified proper voltage output under load. All work completed to code requirements with generator positioned for adequate ventilation and service access.
Generator
Generator Checked in
Completed installation of 22KW standby generator with 200-amp automatic transfer switch on exterior wall of residence. Ran 20 feet of gas line from existing service point to generator location, coordinated with separate contractor for gas line installation. Installed 15 feet of electrical conduit and wiring from main service panel to new exterior transfer switch panel, mounted all equipment on vinyl siding per manufacturer specifications. Configured automatic transfer switch with proper circuit breaker protection, established all electrical connections to generator unit including control wiring and power cables. Tested system operation including automatic start sequence, transfer switch functionality, and verified proper voltage output under load. All work completed to code requirements with generator positioned for adequate ventilation and service access.
Medina, OH 44256
Completed third scheduled maintenance visit on two-year-old MVP furnace system as part of ongoing maintenance plan. Performed comprehensive inspection of heating equipment including control board diagnostics and blower assembly examination. Inspected and photographed control board components, verifying proper DIP switch configurations and sensor connections for outdoor discharge temperature monitoring. Examined blower wheel assembly, confirming blade integrity and proper rotation clearances. All components found to be operating within manufacturer specifications with no immediate service needs identified. System tested and confirmed operational for continued heating season performance.
Completed third scheduled maintenance visit on two-year-old MVP furnace system as part of ongoing maintenance plan. Performed comprehensive inspection of heating equipment including control board diagnostics and blower assembly examination. Inspected and photographed control board components, verifying proper DIP switch configurations and sensor connections for outdoor discharge temperature monitoring. Examined blower wheel assembly, confirming blade integrity and proper rotation clearances. All components found to be operating within manufacturer specifications with no immediate service needs identified. System tested and confirmed operational for continued heating season performance.
Derrick M.
Derrick M. Checked in
Completed third scheduled maintenance visit on two-year-old MVP furnace system as part of ongoing maintenance plan. Performed comprehensive inspection of heating equipment including control board diagnostics and blower assembly examination. Inspected and photographed control board components, verifying proper DIP switch configurations and sensor connections for outdoor discharge temperature monitoring. Examined blower wheel assembly, confirming blade integrity and proper rotation clearances. All components found to be operating within manufacturer specifications with no immediate service needs identified. System tested and confirmed operational for continued heating season performance.
Medina, OH 44256
Completed scheduled furnace maintenance inspection as part of preventive maintenance program. Accessed unit in confined attic space, performed visual inspection of blower assembly and verified proper operation of all mechanical components including the blower wheel housing and ventilation ductwork. System operating within normal parameters with no issues identified.
Completed scheduled furnace maintenance inspection as part of preventive maintenance program. Accessed unit in confined attic space, performed visual inspection of blower assembly and verified proper operation of all mechanical components including the blower wheel housing and ventilation ductwork. System operating within normal parameters with no issues identified.
Derrick M.
Derrick M. Checked in
Completed scheduled furnace maintenance inspection as part of preventive maintenance program. Accessed unit in confined attic space, performed visual inspection of blower assembly and verified proper operation of all mechanical components including the blower wheel housing and ventilation ductwork. System operating within normal parameters with no issues identified.
Medina, OH 44256
Responded to service call for damaged refrigerator water line with active leak. Upon arrival, located the compromised water supply line in the basement area near the water filtration system and main plumbing infrastructure. Shut off water supply at the isolation valve, removed the damaged refrigerator supply line, and installed a new braided stainless steel water line with proper compression fittings. Verified all connections were secure, restored water supply, and tested the new installation for leaks. System operating properly with no leaks detected at time of departure.
Responded to service call for damaged refrigerator water line with active leak. Upon arrival, located the compromised water supply line in the basement area near the water filtration system and main plumbing infrastructure. Shut off water supply at the isolation valve, removed the damaged refrigerator supply line, and installed a new braided stainless steel water line with proper compression fittings. Verified all connections were secure, restored water supply, and tested the new installation for leaks. System operating properly with no leaks detected at time of departure.
Jared K.
Jared K. Checked in
Responded to service call for damaged refrigerator water line with active leak. Upon arrival, located the compromised water supply line in the basement area near the water filtration system and main plumbing infrastructure. Shut off water supply at the isolation valve, removed the damaged refrigerator supply line, and installed a new braided stainless steel water line with proper compression fittings. Verified all connections were secure, restored water supply, and tested the new installation for leaks. System operating properly with no leaks detected at time of departure.
Medina, OH 44256
Completed annual maintenance visit on 1-year-old furnace system as part of MVP heating program. Performed comprehensive inspection of furnace unit and control board assembly, verified all electrical connections and wiring harnesses were secure, and confirmed proper operation of dual circuit board control system. All equipment found operating within normal parameters with no issues identified.
Completed annual maintenance visit on 1-year-old furnace system as part of MVP heating program. Performed comprehensive inspection of furnace unit and control board assembly, verified all electrical connections and wiring harnesses were secure, and confirmed proper operation of dual circuit board control system. All equipment found operating within normal parameters with no issues identified.
Derrick M.
Derrick M. Checked in
Completed annual maintenance visit on 1-year-old furnace system as part of MVP heating program. Performed comprehensive inspection of furnace unit and control board assembly, verified all electrical connections and wiring harnesses were secure, and confirmed proper operation of dual circuit board control system. All equipment found operating within normal parameters with no issues identified.
Medina, OH 44256
Replaced defective main control circuit board in HVAC system. Removed failed PCB assembly from control cabinet, disconnected all wire harnesses and power connections, installed new OEM control board, reconnected all wiring to proper terminals, and verified system operation. Unit tested and returned to normal operation upon completion.
Replaced defective main control circuit board in HVAC system. Removed failed PCB assembly from control cabinet, disconnected all wire harnesses and power connections, installed new OEM control board, reconnected all wiring to proper terminals, and verified system operation. Unit tested and returned to normal operation upon completion.
Jibreel H.
Jibreel H. Checked in
Replaced defective main control circuit board in HVAC system. Removed failed PCB assembly from control cabinet, disconnected all wire harnesses and power connections, installed new OEM control board, reconnected all wiring to proper terminals, and verified system operation. Unit tested and returned to normal operation upon completion.
Medina, OH 44256

 

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image