Air Conditioning, Heating, Electrical & Plumbing Services in Uniontown, OH

When you’re looking for a company to install, repair, and maintain all your HVAC, plumbing, and electrical systems in one fell swoop, there’s no need to worry about scheduling appointments with different service companies. At Blind & Sons, we handle it all! From leaky faucets and power outages to broken air conditioners and worn-out heaters.

Get everything you need for your Uniontown home from Blind & Sons! Call (330) 753-7711 or contact us online for HVAC, electrical, or plumbing services today.

Air Conditioning Services

Air conditioning units

Your home is supposed to be a comfortable haven, but it becomes inconvenient when you can’t cool off or stay indoors because your air conditioner isn’t working correctly. A broken AC can also lead to other issues, including excessive humidity, which can result in mold growth and mildew. To keep your home from feeling like a swamp, our technicians can perform high-quality AC services, including:

Contact Blind & Sons online today or call (330) 753-7711 to schedule a cooling service in Uniontown.

Need Services?

Heating Services

Depending on your heating unit, it can be tricky to know when it’s time to have it serviced by a professional. A few signs to look out for include excessive dust in your home when using your heater, little to no heat being produced, or if your pilot light is discolored. If one or more of these issues are happening with your heating unit, our technicians can get the job done in no time. Our heating specialists perform:

Make warm and cozy a default setting in your Uniontown home. Give us a call at (330) 753-7711 or reach out to us online to schedule a heating service.

Indoor Air Quality Services

Indoor air quality is an often overlooked but deeply concerning issue for many homeowners. At Blind & Sons, we provide high-performance services that keep your home’s indoor air clean and safe to breathe using solutions, including:

Our indoor air quality services are guaranteed to clear your air of harmful particles, including pet dander, pollen, tobacco smoke, cleaning chemicals, and other airborne pathogens.

For help choosing the right indoor air quality solution for your home, call (330) 753-7711 or contact Blind & Sons online for a free consultation.

Plumbing Services

Technician repairing water heater

When it comes to plumbing issues, every second counts. We offer plumbing repair services to protect your home from water damage, pipe damage, and other plumbing issues. To meet all your plumbing needs, we provide a wide range of plumbing services, including:

No plumbing issue is too much for our plumbing experts to handle. Get the help you need and call (330) 753-7711 or contact Blind & Sons online to schedule a plumbing service in the Uniontown area.

Electrical Services

When experiencing problems with your electrical wiring, it can be dangerous to tackle it on your own if you don’t have experience or knowledge of electrical systems. To keep you and your loved ones safe, hire our professional electricians to take on the job. Whether you need new electrical wiring installed, have your old wiring repaired or maintained, or want extra protection in case of emergencies, we offer:

Avoid electrical fires and other electricity-related issues when you choose Blind & Sons. Reach out to us online or call (330) 753-7711 to schedule an electrical service in Uniontown.

Why Choose Blind & Sons?

When it comes to the most high-quality plumbing, HVAC, and electrical services around, no better company does it better than Blind & Sons. With our online scheduling, we make getting services a breeze. We also offer a 100% satisfaction guarantee or your money back. So, what are you waiting for? Long-lasting comfort is just a phone call away!

Call us at (330) 753-7711 or contact Blind & Sons online to schedule a plumbing, HVAC, or electrical service in Uniontown today.

Related Blogs:

 

Recent Jobs and Reviews in Uniontown, OH

Job Locations and Reviews

Responded to service call for 15-year-old electric water heater not producing hot water. Upon assessment, determined unit required replacement per customer request. Completed full water heater replacement, installing new Rheem electric tank unit in basement utility area. Disconnected existing copper supply lines, drained old tank, and removed from service. Installed replacement unit with proper connections to existing plumbing infrastructure, including hot and cold water copper lines secured to overhead framing. Verified all electrical connections via flexible metallic conduit, ensured proper grounding, and tested unit operation. System restored to full functionality with hot water delivery confirmed.
Responded to service call for 15-year-old electric water heater not producing hot water. Upon assessment, determined unit required replacement per customer request. Completed full water heater replacement, installing new Rheem electric tank unit in basement utility area. Disconnected existing copper supply lines, drained old tank, and removed from service. Installed replacement unit with proper connections to existing plumbing infrastructure, including hot and cold water copper lines secured to overhead framing. Verified all electrical connections via flexible metallic conduit, ensured proper grounding, and tested unit operation. System restored to full functionality with hot water delivery confirmed.
David K.
David K. Checked in
Responded to service call for 15-year-old electric water heater not producing hot water. Upon assessment, determined unit required replacement per customer request. Completed full water heater replacement, installing new Rheem electric tank unit in basement utility area. Disconnected existing copper supply lines, drained old tank, and removed from service. Installed replacement unit with proper connections to existing plumbing infrastructure, including hot and cold water copper lines secured to overhead framing. Verified all electrical connections via flexible metallic conduit, ensured proper grounding, and tested unit operation. System restored to full functionality with hot water delivery confirmed.
Uniontown, OH 44685
Uniontown, OH - Completed routine maintenance on residential standby generator unit located in backyard. Performed standard inspection of all mechanical components, verified proper operation of control panel indicator light and connection ports, checked ventilation louvers for obstructions, and confirmed unit remains in functional condition with housing integrity intact.
Bradley L.
Bradley L. Checked in
Completed routine maintenance on residential standby generator unit located in backyard. Performed standard inspection of all mechanical components, verified proper operation of control panel indicator light and connection ports, checked ventilation louvers for obstructions, and confirmed unit remains in functional condition with housing integrity intact.
Uniontown, OH 44685
Completed comprehensive AC tune-up including inspection of electrical components and humidifier system. Removed and examined contactor assembly with dual fuses, verified proper operation and connections. Inspected humidifier evaporator pad for mineral buildup and airflow efficiency, confirmed unit accessibility and all electrical connections secure.
Completed comprehensive AC tune-up including inspection of electrical components and humidifier system. Removed and examined contactor assembly with dual fuses, verified proper operation and connections. Inspected humidifier evaporator pad for mineral buildup and airflow efficiency, confirmed unit accessibility and all electrical connections secure.
Daniel
Daniel Checked in
Completed comprehensive AC tune-up including inspection of electrical components and humidifier system. Removed and examined contactor assembly with dual fuses, verified proper operation and connections. Inspected humidifier evaporator pad for mineral buildup and airflow efficiency, confirmed unit accessibility and all electrical connections secure.
Uniontown, OH 44685
Completed MVP heating maintenance visit on Lennox system. Performed standard heating system inspection, verified operational status of furnace components, and documented equipment condition with photos. Unit accessible at exterior location with refrigerant lines and electrical connections in satisfactory condition.
Completed MVP heating maintenance visit on Lennox system. Performed standard heating system inspection, verified operational status of furnace components, and documented equipment condition with photos. Unit accessible at exterior location with refrigerant lines and electrical connections in satisfactory condition.
Daniel S.
Daniel S. Checked in
Completed MVP heating maintenance visit on Lennox system. Performed standard heating system inspection, verified operational status of furnace components, and documented equipment condition with photos. Unit accessible at exterior location with refrigerant lines and electrical connections in satisfactory condition.
Uniontown, OH 44685
Responded to no cooling complaint on four-year-old residential air conditioning system. Upon arrival, performed complete system diagnostics using digital manifold gauges and temperature probes. Found system operating with suction pressure of 108.0 psi and discharge pressure of 145.2 psi on R410A refrigerant. Measured suction line temperature at 54.0°F with corresponding saturation temperature of 35.3°F, indicating superheat of 18.7°F. Liquid line temperature measured 43.6°F with saturation temperature of 50.8°F, showing subcooling of 7.2°F. Inspected dual run capacitor which showed signs of age and weathering. System readings indicated potential low refrigerant charge or airflow restriction affecting cooling performance. Documented all pressure and temperature readings for service records and provided recommendations for restoring optimal system performance.
Responded to no cooling complaint on four-year-old residential air conditioning system. Upon arrival, performed complete system diagnostics using digital manifold gauges and temperature probes. Found system operating with suction pressure of 108.0 psi and discharge pressure of 145.2 psi on R410A refrigerant. Measured suction line temperature at 54.0°F with corresponding saturation temperature of 35.3°F, indicating superheat of 18.7°F. Liquid line temperature measured 43.6°F with saturation temperature of 50.8°F, showing subcooling of 7.2°F. Inspected dual run capacitor which showed signs of age and weathering. System readings indicated potential low refrigerant charge or airflow restriction affecting cooling performance. Documented all pressure and temperature readings for service records and provided recommendations for restoring optimal system performance.
John W.
John W. Checked in
Responded to no cooling complaint on four-year-old residential air conditioning system. Upon arrival, performed complete system diagnostics using digital manifold gauges and temperature probes. Found system operating with suction pressure of 108.0 psi and discharge pressure of 145.2 psi on R410A refrigerant. Measured suction line temperature at 54.0°F with corresponding saturation temperature of 35.3°F, indicating superheat of 18.7°F. Liquid line temperature measured 43.6°F with saturation temperature of 50.8°F, showing subcooling of 7.2°F. Inspected dual run capacitor which showed signs of age and weathering. System readings indicated potential low refrigerant charge or airflow restriction affecting cooling performance. Documented all pressure and temperature readings for service records and provided recommendations for restoring optimal system performance.
Uniontown, OH 44685
Completed comprehensive AC tune-up and maintenance inspection on residential air conditioning system. Performed visual inspection of air handler unit, examining electrical control panel and wiring connections for proper operation and safety compliance. Inspected return air filter, noting accumulated debris and particulate matter trapped in filter media, indicating normal filtration function. Checked all electrical connections, terminal blocks, and relay components within control panel for secure mounting and proper wire routing. Verified all safety labels and warning placards remain legible and in place. System operational and ready for cooling season.
Completed comprehensive AC tune-up and maintenance inspection on residential air conditioning system. Performed visual inspection of air handler unit, examining electrical control panel and wiring connections for proper operation and safety compliance. Inspected return air filter, noting accumulated debris and particulate matter trapped in filter media, indicating normal filtration function. Checked all electrical connections, terminal blocks, and relay components within control panel for secure mounting and proper wire routing. Verified all safety labels and warning placards remain legible and in place. System operational and ready for cooling season.
Taylor F.
Taylor F. Checked in
Completed comprehensive AC tune-up and maintenance inspection on residential air conditioning system. Performed visual inspection of air handler unit, examining electrical control panel and wiring connections for proper operation and safety compliance. Inspected return air filter, noting accumulated debris and particulate matter trapped in filter media, indicating normal filtration function. Checked all electrical connections, terminal blocks, and relay components within control panel for secure mounting and proper wire routing. Verified all safety labels and warning placards remain legible and in place. System operational and ready for cooling season.
Uniontown, OH 44685
Responded to service call for 7-year-old Generac natural gas generator displaying battery check warning message. Performed diagnostic inspection of unit, verified operational status with green indicator light illuminated, and assessed battery condition and charging system. Documented equipment condition with photos showing outdoor installation on gravel pad with visible weathering on exterior housing.
Responded to service call for 7-year-old Generac natural gas generator displaying battery check warning message. Performed diagnostic inspection of unit, verified operational status with green indicator light illuminated, and assessed battery condition and charging system. Documented equipment condition with photos showing outdoor installation on gravel pad with visible weathering on exterior housing.
Logan H.
Logan H. Checked in
Responded to service call for 7-year-old Generac natural gas generator displaying battery check warning message. Performed diagnostic inspection of unit, verified operational status with green indicator light illuminated, and assessed battery condition and charging system. Documented equipment condition with photos showing outdoor installation on gravel pad with visible weathering on exterior housing.
Uniontown, OH 44685
Completed preventive maintenance tune-up on 5-year-old air conditioning system per customer request. Performed comprehensive inspection of system components including air filter, control board, electrical connections, and refrigerant circuit. All components found operating within normal parameters with no deficiencies noted.
Completed preventive maintenance tune-up on 5-year-old air conditioning system per customer request. Performed comprehensive inspection of system components including air filter, control board, electrical connections, and refrigerant circuit. All components found operating within normal parameters with no deficiencies noted.
Stephanie E.
Stephanie E. Checked in
Completed preventive maintenance tune-up on 5-year-old air conditioning system per customer request. Performed comprehensive inspection of system components including air filter, control board, electrical connections, and refrigerant circuit. All components found operating within normal parameters with no deficiencies noted.
Uniontown, OH 44685
Uniontown, OH - Completed scheduled MVP furnace maintenance visit and performed comprehensive system inspection. Accessed interior components, verified structural integrity of mounting brackets and support framework, and inspected electrical wiring harness connections for proper routing and secure terminations. All mechanical components and wiring found in acceptable operating condition with normal wear patterns observed.
Derrick M.
Derrick M. Checked in
Completed scheduled MVP furnace maintenance visit and performed comprehensive system inspection. Accessed interior components, verified structural integrity of mounting brackets and support framework, and inspected electrical wiring harness connections for proper routing and secure terminations. All mechanical components and wiring found in acceptable operating condition with normal wear patterns observed.
Uniontown, OH 44685
Completed comprehensive furnace tune-up and system inspection. Identified heavily soiled air filter with significant dust and debris accumulation throughout the mesh structure, restricting proper airflow to the system. Recommended filter replacement to restore optimal system performance and indoor air quality.
Completed comprehensive furnace tune-up and system inspection. Identified heavily soiled air filter with significant dust and debris accumulation throughout the mesh structure, restricting proper airflow to the system. Recommended filter replacement to restore optimal system performance and indoor air quality.
Stephanie E.
Stephanie E. Checked in
Completed comprehensive furnace tune-up and system inspection. Identified heavily soiled air filter with significant dust and debris accumulation throughout the mesh structure, restricting proper airflow to the system. Recommended filter replacement to restore optimal system performance and indoor air quality.
Uniontown, OH 44685
Completed early season air conditioning tune-up on residential system. Upon inspection, discovered evaporator coil heavily contaminated with dust and debris accumulation, significantly restricting airflow and reducing system efficiency. Cleaned evaporator coil thoroughly, inspected electrical connections and capacitor in control panel, verified all wiring secure and properly terminated. System operational following service.
Completed early season air conditioning tune-up on residential system. Upon inspection, discovered evaporator coil heavily contaminated with dust and debris accumulation, significantly restricting airflow and reducing system efficiency. Cleaned evaporator coil thoroughly, inspected electrical connections and capacitor in control panel, verified all wiring secure and properly terminated. System operational following service.
Derrick M.
Derrick M. Checked in
Completed early season air conditioning tune-up on residential system. Upon inspection, discovered evaporator coil heavily contaminated with dust and debris accumulation, significantly restricting airflow and reducing system efficiency. Cleaned evaporator coil thoroughly, inspected electrical connections and capacitor in control panel, verified all wiring secure and properly terminated. System operational following service.
Uniontown, OH 44685
Responded to service call for leaking humidifier on HVAC system. Upon inspection, discovered significant rust and corrosion on the humidifier mounting bracket and water distribution components. The leak originated from deteriorated water feed line connections and corroded metal surfaces that had compromised the unit's water containment integrity. Documented existing conditions with photos showing extensive rust damage on horizontal support bracket and aging filter assembly. Performed diagnostic evaluation and provided customer with repair options and recommendations for addressing the moisture infiltration issue to prevent further system damage.
Responded to service call for leaking humidifier on HVAC system. Upon inspection, discovered significant rust and corrosion on the humidifier mounting bracket and water distribution components. The leak originated from deteriorated water feed line connections and corroded metal surfaces that had compromised the unit's water containment integrity. Documented existing conditions with photos showing extensive rust damage on horizontal support bracket and aging filter assembly. Performed diagnostic evaluation and provided customer with repair options and recommendations for addressing the moisture infiltration issue to prevent further system damage.
Daniel
Daniel Checked in
Responded to service call for leaking humidifier on HVAC system. Upon inspection, discovered significant rust and corrosion on the humidifier mounting bracket and water distribution components. The leak originated from deteriorated water feed line connections and corroded metal surfaces that had compromised the unit's water containment integrity. Documented existing conditions with photos showing extensive rust damage on horizontal support bracket and aging filter assembly. Performed diagnostic evaluation and provided customer with repair options and recommendations for addressing the moisture infiltration issue to prevent further system damage.
Uniontown, OH 44685
Uniontown, OH - Responded to service call for non-functional hot water heater in a 20-year-old residential property. Upon arrival, inspected the Bradford White Defender Safety System tanked water heater and associated plumbing infrastructure. Diagnosed system failure and performed necessary repairs to restore hot water functionality. Verified proper operation of expansion tank with pressure relief connections, inspected all copper supply and distribution lines for integrity, and tested shut-off valves and safety systems. Confirmed water heater returned to normal operating parameters with adequate hot water delivery throughout the residence.
Isaiah H.
Isaiah H. Checked in
Responded to service call for non-functional hot water heater in a 20-year-old residential property. Upon arrival, inspected the Bradford White Defender Safety System tanked water heater and associated plumbing infrastructure. Diagnosed system failure and performed necessary repairs to restore hot water functionality. Verified proper operation of expansion tank with pressure relief connections, inspected all copper supply and distribution lines for integrity, and tested shut-off valves and safety systems. Confirmed water heater returned to normal operating parameters with adequate hot water delivery throughout the residence.
Uniontown, OH 44685
Uniontown, OH - # Service Summary

Responded to service call for well water system with odor issues at residence with existing water softener. Homeowner recently relocated to property and unfamiliar with water treatment system operation.

# Work Performed

Conducted comprehensive evaluation of existing well water treatment system including water softener and associated plumbing infrastructure. Inspected Rheem Professional water heater installation with copper supply lines and verified proper venting through galvanized flue pipe. Assessed water quality concerns related to sulfur odor commonly associated with well water systems containing hydrogen sulfide gas or sulfur bacteria.

Examined water softener unit for proper operation, salt levels, and regeneration cycle functionality. Tested water quality parameters to identify source of odor issues. Determined that water softener alone was insufficient to address hydrogen sulfide contamination present in well water supply.

Provided homeowner education on w
Nick L.
Nick L. Checked in
# Service Summary Responded to service call for well water system with odor issues at residence with existing water softener. Homeowner recently relocated to property and unfamiliar with water treatment system operation. # Work Performed Conducted comprehensive evaluation of existing well water treatment system including water softener and associated plumbing infrastructure. Inspected Rheem Professional water heater installation with copper supply lines and verified proper venting through galvanized flue pipe. Assessed water quality concerns related to sulfur odor commonly associated with well water systems containing hydrogen sulfide gas or sulfur bacteria. Examined water softener unit for proper operation, salt levels, and regeneration cycle functionality. Tested water quality parameters to identify source of odor issues. Determined that water softener alone was insufficient to address hydrogen sulfide contamination present in well water supply. Provided homeowner education on w
Uniontown, OH 44685
# HVAC Estimate - Replacement Summary

Conducted comprehensive on-site evaluation for complete HVAC system replacement. Assessed existing furnace and air conditioning equipment located in interior utility closet, documenting current unit specifications and installation configuration. Evaluated attic space accessibility and existing ductwork infrastructure to determine optimal replacement system specifications and installation requirements for new heating and cooling equipment.
# HVAC Estimate - Replacement Summary

Conducted comprehensive on-site evaluation for complete HVAC system replacement. Assessed existing furnace and air conditioning equipment located in interior utility closet, documenting current unit specifications and installation configuration. Evaluated attic space accessibility and existing ductwork infrastructure to determine optimal replacement system specifications and installation requirements for new heating and cooling equipment.
Jordan K.
Jordan K. Checked in
# HVAC Estimate - Replacement Summary Conducted comprehensive on-site evaluation for complete HVAC system replacement. Assessed existing furnace and air conditioning equipment located in interior utility closet, documenting current unit specifications and installation configuration. Evaluated attic space accessibility and existing ductwork infrastructure to determine optimal replacement system specifications and installation requirements for new heating and cooling equipment.
Uniontown, OH 44685
Uniontown, OH - Completed scheduled maintenance on Trane XV80 furnace in basement utility room. Inspected heat exchanger, checked ventilation system, and noted condensation on exhaust ducting. All components functioning within normal parameters; system ready for continued operation.
William S.
William S. Checked in
Completed scheduled maintenance on Trane XV80 furnace in basement utility room. Inspected heat exchanger, checked ventilation system, and noted condensation on exhaust ducting. All components functioning within normal parameters; system ready for continued operation.
Uniontown, OH 44685
Successfully replaced two customer-supplied lavatory faucets with new angle stops in the hall bathroom and basement. Removed existing plumbing components and installed new tubular trap in the first-floor bathroom, while the basement lavatory required cutting off the PVC fitting and installing a new ABS trap adapter with appropriate connections.
Successfully replaced two customer-supplied lavatory faucets with new angle stops in the hall bathroom and basement. Removed existing plumbing components and installed new tubular trap in the first-floor bathroom, while the basement lavatory required cutting off the PVC fitting and installing a new ABS trap adapter with appropriate connections.
David K.
David K. Checked in
Successfully replaced two customer-supplied lavatory faucets with new angle stops in the hall bathroom and basement. Removed existing plumbing components and installed new tubular trap in the first-floor bathroom, while the basement lavatory required cutting off the PVC fitting and installing a new ABS trap adapter with appropriate connections.
Uniontown, OH 44685
Uniontown, OH - Responded to service call for water softener issues causing black discoloration in water and brown toilets. Upon inspection, discovered significant mineral buildup and sediment in faucet aerator indicating system failure. Cleaned affected aerators and recommended complete water softener regeneration and system maintenance to resolve discoloration issues throughout the home.
James P.
James P. Checked in
Responded to service call for water softener issues causing black discoloration in water and brown toilets. Upon inspection, discovered significant mineral buildup and sediment in faucet aerator indicating system failure. Cleaned affected aerators and recommended complete water softener regeneration and system maintenance to resolve discoloration issues throughout the home.
Uniontown, OH 44685
Successfully installed two customer-provided faucets in a 30-year-old home, ensuring proper connection of supply lines and drain assemblies with functional P-trap configurations. Additionally, resealed toilet to prevent leakage, with all installations verified for proper operation and absence of leaks.
Successfully installed two customer-provided faucets in a 30-year-old home, ensuring proper connection of supply lines and drain assemblies with functional P-trap configurations. Additionally, resealed toilet to prevent leakage, with all installations verified for proper operation and absence of leaks.
Travis B.
Travis B. Checked in
Successfully installed two customer-provided faucets in a 30-year-old home, ensuring proper connection of supply lines and drain assemblies with functional P-trap configurations. Additionally, resealed toilet to prevent leakage, with all installations verified for proper operation and absence of leaks.
Uniontown, OH 44685
Uniontown, OH - Diagnosed Generac whole house generator failure issue that prevented operation during recent power outage. Identified fault code on control panel associated with yellow warning light, performed system reset and cleared error codes. Conducted full system diagnostic test, replaced clogged air filter, and verified proper voltage output during simulated power outage test to confirm unit now functions correctly.
Patrick W.
Patrick W. Checked in
Diagnosed Generac whole house generator failure issue that prevented operation during recent power outage. Identified fault code on control panel associated with yellow warning light, performed system reset and cleared error codes. Conducted full system diagnostic test, replaced clogged air filter, and verified proper voltage output during simulated power outage test to confirm unit now functions correctly.
Uniontown, OH 44685

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image