Trusted HVAC, Plumbing & Electrical Services in Canton, OH

Hand changing the temperature on a boiler

Blind & Sons is proud to be Canton’s go-to provider for reliable, high-quality home services. For over 80 years, we’ve served Northeast Ohio with expert care and personalized service. From heating and cooling installations to fast plumbing repairs and advanced electrical upgrades, our certified team delivers comfort, safety, and peace of mind—every time.

Whether you live in a historic home downtown or a modern property in a growing neighborhood, we tailor every service to your home’s unique needs. When you’re ready to upgrade your HVAC system, repair a leaking pipe, or install an EV charger, Blind & Sons is the name Canton homeowners trust. Call (330) 753-7711 today or contact us online to get started. 

Local Expertise for Canton, OH Homes

Home to the Pro Football Hall of Fame, the McKinley Monument, and a rich industrial legacy, Canton is one of Ohio’s most historic and vibrant cities. The area’s wide range of architecture and building ages—from early 1900s homes to newly built residences—requires a team that knows how to work with both modern systems and aging infrastructure.

At Blind & Sons, we bring specialized expertise, respect for Canton’s architectural diversity, and a commitment to keeping our local community safe and comfortable. We proudly serve neighborhoods throughout Stark County with solutions built to last.

Superior Plumbing Services in Canton

Plumbing problems can derail your day fast. At Blind & Sons, we make plumbing stress-free with fast diagnostics, clear pricing, and high-quality repairs. Whether it’s a clogged drain, low water pressure, or a complete water heater replacement, we’re the plumbing partner you can trust in Canton. Our plumbing services in Canton include:

  • Drain Cleaning: Advanced tools and techniques to eliminate clogs and restore flow in sinks, tubs, and sewer lines
  • Water Heater Services: We install, repair, and maintain both traditional tank and tankless water heaters
  • Gas Line Plumbing: Safe and professional gas line installation, inspection, and repairs for home appliances and systems
  • Sump Pump Services: Protect your basement from flooding with expert sump pump installation and maintenance
  • Fixture Repairs & Replacements: Toilets, sinks, faucets, garbage disposals, shutoff valves, and more

We deliver lasting plumbing solutions that keep your water clean, safe, and flowing efficiently year-round.

Need Services?

Top-Rated Electrical Services in Canton, OH

Whether you’re upgrading your electrical panel or planning to install a whole-home generator, Blind & Sons has the skills and experience to get the job done right. Our certified electricians in Canton deliver safe, code-compliant electrical work that meets Canton’s unique residential needs.

From small repairs to whole-home wiring projects, we bring power and peace of mind to Canton homes.

Canton Heating Repair & Replacement

When temperatures drop in Stark County, your heating system becomes more than a comfort—it’s a necessity. At Blind & Sons, we provide expert heating installation, maintenance, and repair services to keep your home warm all winter long.

We work with all major types of heating systems, including:

  • Furnaces: We repair and replace both gas and electric furnace systems
  • Boilers: We maintain and replace steam and hot water boilers for traditional radiant heat
  • Heat Pumps: Dual-function systems for year-round energy-efficient heating and cooling
  • Ductless HVAC Units: Perfect for home additions, garages, or homes without central ductwork

Not sure if your heating system needs repair or replacement? We’ll evaluate your setup and provide honest recommendations tailored to your home and budget.

Air Conditioning Services in Canton, OH

Heat pump unit outside a brick building

Ohio summers bring high heat and humidity. Blind & Sons offers fast, dependable air conditioning services to help you beat the heat and enjoy reliable indoor comfort. Whether you’re upgrading to a more energy-efficient model or need an emergency repair, our AC experts are ready to help.

  • AC Installation: We install central air systems, ductless mini-splits, and heat pump ACs sized specifically for your home
  • AC Replacement: Replace outdated units with modern, high-efficiency models that save money and reduce energy waste
  • Emergency AC Repair: Our technicians are available day and night to restore cooling as quickly as possible
  • AC Maintenance: Seasonal checkups and filter changes ensure maximum performance and system longevity

Stay cool and reduce your energy bills with optimized AC performance all summer long.

Need Services?

Why Canton Homeowners Choose Blind & Sons

For more than 85 years, Blind & Sons has been Canton’s trusted source for HVAC, plumbing, and electrical service. We’ve earned that trust through our unwavering commitment to high standards, ongoing training, and top-tier customer care.

Here’s what sets us apart:

  • 100% Satisfaction Guarantee—We won’t rest until you’re happy with our work
  • Certified, Background-Checked Technicians—Safety, expertise, and professionalism on every job
  • Upfront Pricing & No-Obligation Estimates—Know exactly what you’ll pay before work begins
  • Emergency HVAC Services—We’re always here when you need us
  • MVP Maintenance Plans—Year-round protection, priority service, and exclusive discounts
  • Community-Focused—We’re proud to support local events, schools, and charitable causes in Canton and throughout Stark County

We don’t just serve homes—we serve our neighbors.

Schedule Your Canton Home Services Today

Whether you’re facing a sudden AC failure, planning a new furnace installation, replacing a failing water heater, or upgrading your home’s lighting, Blind & Sons is here to help. With decades of experience and a team that truly cares, we’re proud to provide the top HVAC, plumbing, and electrical services in Canton, OH.

Call Blind & Sons at (330) 753-7711 or contact us online now to schedule expert HVAC, plumbing, or electrical service in Canton, OH.

 

Recent Jobs and Reviews in Canton, OH

Job Locations and Reviews

Responded to service call for water leak of unknown origin in residential property. Upon arrival, conducted thorough inspection of basement utility area and identified extensive water damage and rust staining on ceiling surfaces, walls, and mechanical equipment. Located active leak source at water heater connections, with significant moisture intrusion evident from brown discoloration patterns on overhead surfaces and corroded piping components. Observed compromised pipe fittings with visible corrosion on copper supply lines and deteriorated connections at water heater inlet. Documented existing conditions showing heavy rust streaking on white cylindrical water heater tank and surrounding infrastructure, indicating prolonged moisture exposure. Photographed damaged areas including water-stained ceiling joists, corroded piping systems with green-tinted valve fittings, and affected concrete floor surfaces for record purposes.
Responded to service call for water leak of unknown origin in residential property. Upon arrival, conducted thorough inspection of basement utility area and identified extensive water damage and rust staining on ceiling surfaces, walls, and mechanical equipment. Located active leak source at water heater connections, with significant moisture intrusion evident from brown discoloration patterns on overhead surfaces and corroded piping components. Observed compromised pipe fittings with visible corrosion on copper supply lines and deteriorated connections at water heater inlet. Documented existing conditions showing heavy rust streaking on white cylindrical water heater tank and surrounding infrastructure, indicating prolonged moisture exposure. Photographed damaged areas including water-stained ceiling joists, corroded piping systems with green-tinted valve fittings, and affected concrete floor surfaces for record purposes.
Mark W.
Mark W. Checked in
Responded to service call for water leak of unknown origin in residential property. Upon arrival, conducted thorough inspection of basement utility area and identified extensive water damage and rust staining on ceiling surfaces, walls, and mechanical equipment. Located active leak source at water heater connections, with significant moisture intrusion evident from brown discoloration patterns on overhead surfaces and corroded piping components. Observed compromised pipe fittings with visible corrosion on copper supply lines and deteriorated connections at water heater inlet. Documented existing conditions showing heavy rust streaking on white cylindrical water heater tank and surrounding infrastructure, indicating prolonged moisture exposure. Photographed damaged areas including water-stained ceiling joists, corroded piping systems with green-tinted valve fittings, and affected concrete floor surfaces for record purposes.
Canton, OH 44709
Completed MVP recurring cooling maintenance visit on residential HVAC system. Performed comprehensive inspection of furnace unit and cooling components, including examination of control board, electrical connections, and ductwork. Documented system condition through interior cabinet inspection showing control board with relays, capacitors, and wiring connections, as well as overall unit installation in basement mechanical room. All components operational and system functioning within normal parameters.
Completed MVP recurring cooling maintenance visit on residential HVAC system. Performed comprehensive inspection of furnace unit and cooling components, including examination of control board, electrical connections, and ductwork. Documented system condition through interior cabinet inspection showing control board with relays, capacitors, and wiring connections, as well as overall unit installation in basement mechanical room. All components operational and system functioning within normal parameters.
Derrick M.
Derrick M. Checked in
Completed MVP recurring cooling maintenance visit on residential HVAC system. Performed comprehensive inspection of furnace unit and cooling components, including examination of control board, electrical connections, and ductwork. Documented system condition through interior cabinet inspection showing control board with relays, capacitors, and wiring connections, as well as overall unit installation in basement mechanical room. All components operational and system functioning within normal parameters.
Canton, OH 44709
Responded to complaint of intermittent sewer odor in basement and bathroom. Upon inspection, identified floor drain with deteriorated trap assembly showing signs of dry trap syndrome. Floor drain grate exhibited heavy rust and corrosion with visible standing water in basin. Determined trap seal was evaporating due to infrequent use, allowing sewer gases to enter living space. Flushed floor drain with water to restore trap seal and advised property owner on maintenance requirements including periodic water addition to maintain proper trap function. Documented existing conditions of basement plumbing fixtures including corroded floor drain assembly and utility piping. Recommended monitoring drain for odor recurrence and consideration of trap primer installation for long-term solution if odors persist.
Responded to complaint of intermittent sewer odor in basement and bathroom. Upon inspection, identified floor drain with deteriorated trap assembly showing signs of dry trap syndrome. Floor drain grate exhibited heavy rust and corrosion with visible standing water in basin. Determined trap seal was evaporating due to infrequent use, allowing sewer gases to enter living space. Flushed floor drain with water to restore trap seal and advised property owner on maintenance requirements including periodic water addition to maintain proper trap function. Documented existing conditions of basement plumbing fixtures including corroded floor drain assembly and utility piping. Recommended monitoring drain for odor recurrence and consideration of trap primer installation for long-term solution if odors persist.
Mark W.
Mark W. Checked in
Responded to complaint of intermittent sewer odor in basement and bathroom. Upon inspection, identified floor drain with deteriorated trap assembly showing signs of dry trap syndrome. Floor drain grate exhibited heavy rust and corrosion with visible standing water in basin. Determined trap seal was evaporating due to infrequent use, allowing sewer gases to enter living space. Flushed floor drain with water to restore trap seal and advised property owner on maintenance requirements including periodic water addition to maintain proper trap function. Documented existing conditions of basement plumbing fixtures including corroded floor drain assembly and utility piping. Recommended monitoring drain for odor recurrence and consideration of trap primer installation for long-term solution if odors persist.
Canton, OH 44709
Completed routine maintenance service on a 2-year-old furnace system. Replaced the existing Aprilaire 413 air filter (16 x 25 x 4) with a new unit to ensure proper airflow and system efficiency. Verified furnace operation and confirmed all components functioning within normal parameters.
Completed routine maintenance service on a 2-year-old furnace system. Replaced the existing Aprilaire 413 air filter (16 x 25 x 4) with a new unit to ensure proper airflow and system efficiency. Verified furnace operation and confirmed all components functioning within normal parameters.
William S.
William S. Checked in
Completed routine maintenance service on a 2-year-old furnace system. Replaced the existing Aprilaire 413 air filter (16 x 25 x 4) with a new unit to ensure proper airflow and system efficiency. Verified furnace operation and confirmed all components functioning within normal parameters.
Canton, OH 44704
Completed MVP recurring cooling maintenance visit on HVAC system. Performed comprehensive inspection of evaporator coil assembly, noting dust accumulation on aluminum fins and normal condensation present at panel junctions. Documented control board wiring configuration and electrical connections, verifying all wire harness connections to yellow circuit board were secure. All system components found operational with typical wear patterns consistent with regular use.
Completed MVP recurring cooling maintenance visit on HVAC system. Performed comprehensive inspection of evaporator coil assembly, noting dust accumulation on aluminum fins and normal condensation present at panel junctions. Documented control board wiring configuration and electrical connections, verifying all wire harness connections to yellow circuit board were secure. All system components found operational with typical wear patterns consistent with regular use.
Stephanie E.
Stephanie E. Checked in
Completed MVP recurring cooling maintenance visit on HVAC system. Performed comprehensive inspection of evaporator coil assembly, noting dust accumulation on aluminum fins and normal condensation present at panel junctions. Documented control board wiring configuration and electrical connections, verifying all wire harness connections to yellow circuit board were secure. All system components found operational with typical wear patterns consistent with regular use.
Canton, OH 44709
Canton, OH - Responded to call for upstairs toilet emitting sewer odor. Upon inspection, identified failed wax ring seal at toilet base allowing sewer gas to escape into bathroom. Removed toilet, replaced wax ring, reinstalled and resealed unit to eliminate odor issue.
Karl M.
Karl M. Checked in
Responded to call for upstairs toilet emitting sewer odor. Upon inspection, identified failed wax ring seal at toilet base allowing sewer gas to escape into bathroom. Removed toilet, replaced wax ring, reinstalled and resealed unit to eliminate odor issue.
Canton, OH 44708
# HVAC Maintenance - Cooling Service Completed

Performed scheduled MVP cooling maintenance visit on residential HVAC system. Conducted comprehensive inspection of control board assembly, verifying proper operation of all electronic components, circuit connections, and terminal blocks. All wiring connections, including power and control circuits, were found secure with no signs of overheating or deterioration. Circuit boards showed normal operation with all indicator lights functioning correctly.

Inspected associated mechanical equipment in utility area, noting water heater condition with visible corrosion and rust staining on tank surface. Verified all copper piping connections and fittings remained secure. System tested and confirmed operational within normal parameters upon completion of maintenance visit.
# HVAC Maintenance - Cooling Service Completed

Performed scheduled MVP cooling maintenance visit on residential HVAC system. Conducted comprehensive inspection of control board assembly, verifying proper operation of all electronic components, circuit connections, and terminal blocks. All wiring connections, including power and control circuits, were found secure with no signs of overheating or deterioration. Circuit boards showed normal operation with all indicator lights functioning correctly.

Inspected associated mechanical equipment in utility area, noting water heater condition with visible corrosion and rust staining on tank surface. Verified all copper piping connections and fittings remained secure. System tested and confirmed operational within normal parameters upon completion of maintenance visit.
Stephanie E.
Stephanie E. Checked in
# HVAC Maintenance - Cooling Service Completed Performed scheduled MVP cooling maintenance visit on residential HVAC system. Conducted comprehensive inspection of control board assembly, verifying proper operation of all electronic components, circuit connections, and terminal blocks. All wiring connections, including power and control circuits, were found secure with no signs of overheating or deterioration. Circuit boards showed normal operation with all indicator lights functioning correctly. Inspected associated mechanical equipment in utility area, noting water heater condition with visible corrosion and rust staining on tank surface. Verified all copper piping connections and fittings remained secure. System tested and confirmed operational within normal parameters upon completion of maintenance visit.
Canton, OH 44709
Responded to no-cooling call and diagnosed loose wire connections at contactor causing overheating, wire failure, and blown fuse. Repaired damaged wiring, secured all electrical connections, and replaced failed fuse to restore cooling operation. System tested and confirmed operating normally. Contactor shows burn damage and scorching from electrical fault and has been ordered for replacement during follow-up visit.
Responded to no-cooling call and diagnosed loose wire connections at contactor causing overheating, wire failure, and blown fuse. Repaired damaged wiring, secured all electrical connections, and replaced failed fuse to restore cooling operation. System tested and confirmed operating normally. Contactor shows burn damage and scorching from electrical fault and has been ordered for replacement during follow-up visit.
Derrick M.
Derrick M. Checked in
Responded to no-cooling call and diagnosed loose wire connections at contactor causing overheating, wire failure, and blown fuse. Repaired damaged wiring, secured all electrical connections, and replaced failed fuse to restore cooling operation. System tested and confirmed operating normally. Contactor shows burn damage and scorching from electrical fault and has been ordered for replacement during follow-up visit.
Canton, OH 44718
Completed annual preventative maintenance on two-year-old Lennox cooling system. Performed comprehensive inspection of indoor evaporator coil unit and outdoor condensing unit, including electrical connections, capacitor operation, and refrigerant circuit components. Verified all wiring connections secure, tested capacitor functionality, and confirmed system operating within manufacturer specifications with no deficiencies noted.
Completed annual preventative maintenance on two-year-old Lennox cooling system. Performed comprehensive inspection of indoor evaporator coil unit and outdoor condensing unit, including electrical connections, capacitor operation, and refrigerant circuit components. Verified all wiring connections secure, tested capacitor functionality, and confirmed system operating within manufacturer specifications with no deficiencies noted.
William S.
William S. Checked in
Completed annual preventative maintenance on two-year-old Lennox cooling system. Performed comprehensive inspection of indoor evaporator coil unit and outdoor condensing unit, including electrical connections, capacitor operation, and refrigerant circuit components. Verified all wiring connections secure, tested capacitor functionality, and confirmed system operating within manufacturer specifications with no deficiencies noted.
Canton, OH 44709
Replaced upstairs bathtub shower valve assembly including installation of new rough-in valve with integral stops and repair plate. Installed oil-rubbed bronze Moen Eva trim package to match existing bathroom fixtures. All components ordered with appropriate lead time and installation completed upon parts arrival, resulting in fully functional tub-shower control system with updated aesthetic finish.
Replaced upstairs bathtub shower valve assembly including installation of new rough-in valve with integral stops and repair plate. Installed oil-rubbed bronze Moen Eva trim package to match existing bathroom fixtures. All components ordered with appropriate lead time and installation completed upon parts arrival, resulting in fully functional tub-shower control system with updated aesthetic finish.
Karl M.
Karl M. Checked in
Replaced upstairs bathtub shower valve assembly including installation of new rough-in valve with integral stops and repair plate. Installed oil-rubbed bronze Moen Eva trim package to match existing bathroom fixtures. All components ordered with appropriate lead time and installation completed upon parts arrival, resulting in fully functional tub-shower control system with updated aesthetic finish.
Canton, OH 44718
Installed dedicated electrical circuit for new Daikin Aurora heat pump system. Ran electrical conduit from outdoor disconnect box to main electrical panel, installed appropriately sized circuit breaker, and completed all wiring connections per manufacturer specifications and local electrical code requirements.
Installed dedicated electrical circuit for new Daikin Aurora heat pump system. Ran electrical conduit from outdoor disconnect box to main electrical panel, installed appropriately sized circuit breaker, and completed all wiring connections per manufacturer specifications and local electrical code requirements.
Austin B.
Austin B. Checked in
Installed dedicated electrical circuit for new Daikin Aurora heat pump system. Ran electrical conduit from outdoor disconnect box to main electrical panel, installed appropriately sized circuit breaker, and completed all wiring connections per manufacturer specifications and local electrical code requirements.
Canton, OH 44708
Replaced defective GFCI outlet on exterior light post due to failure of protection mechanism. Installed two additional exterior outlets to provide adequate outdoor power access points as requested. All exterior electrical work completed per safety standards, excluding attic work due to presence of vermiculite insulation containing asbestos.
Replaced defective GFCI outlet on exterior light post due to failure of protection mechanism. Installed two additional exterior outlets to provide adequate outdoor power access points as requested. All exterior electrical work completed per safety standards, excluding attic work due to presence of vermiculite insulation containing asbestos.
Andrew V.
Andrew V. Checked in
Replaced defective GFCI outlet on exterior light post due to failure of protection mechanism. Installed two additional exterior outlets to provide adequate outdoor power access points as requested. All exterior electrical work completed per safety standards, excluding attic work due to presence of vermiculite insulation containing asbestos.
Canton, OH 44714
Completed installation of a 2-head ductless mini-split system in an attic space. Mounted indoor air handler unit on plywood wall, installed electrical disconnect with fused protection, and routed refrigerant lines and condensate drainage per manufacturer specifications.
Completed installation of a 2-head ductless mini-split system in an attic space. Mounted indoor air handler unit on plywood wall, installed electrical disconnect with fused protection, and routed refrigerant lines and condensate drainage per manufacturer specifications.
Chris H.
Chris H. Checked in
Completed installation of a 2-head ductless mini-split system in an attic space. Mounted indoor air handler unit on plywood wall, installed electrical disconnect with fused protection, and routed refrigerant lines and condensate drainage per manufacturer specifications.
Canton, OH 44708
Relocated washing machine to new position, requiring extensive plumbing modifications and labor. Parts were pre-staged in shop along with water heater kit for efficient installation. Work completed with photographic documentation showing flooring transitions and installation area in preparation for appliance repositioning.
Relocated washing machine to new position, requiring extensive plumbing modifications and labor. Parts were pre-staged in shop along with water heater kit for efficient installation. Work completed with photographic documentation showing flooring transitions and installation area in preparation for appliance repositioning.
James P.
James P. Checked in
Relocated washing machine to new position, requiring extensive plumbing modifications and labor. Parts were pre-staged in shop along with water heater kit for efficient installation. Work completed with photographic documentation showing flooring transitions and installation area in preparation for appliance repositioning.
Canton, OH 44708
Performed warranty leak search on residential air conditioning system. Used Fieldpiece digital manifold gauges to check refrigerant pressures and diagnose potential leak points on outdoor condenser unit. Conducted inspection after customer departed premises to complete thorough diagnostic testing on the system.
Performed warranty leak search on residential air conditioning system. Used Fieldpiece digital manifold gauges to check refrigerant pressures and diagnose potential leak points on outdoor condenser unit. Conducted inspection after customer departed premises to complete thorough diagnostic testing on the system.
Colton D.
Colton D. Checked in
Performed warranty leak search on residential air conditioning system. Used Fieldpiece digital manifold gauges to check refrigerant pressures and diagnose potential leak points on outdoor condenser unit. Conducted inspection after customer departed premises to complete thorough diagnostic testing on the system.
Canton, OH 44714
Canton, OH - Provided comprehensive estimate for complete central air conditioning system replacement. Existing outdoor condensing unit is over 10 years old, has required repairs in two consecutive years, and is currently non-operational. Evaluated existing equipment configuration, photographed current installation showing outdoor unit on concrete pad with refrigerant lines running to building, and assessed replacement requirements. Presented equipment options with warranty coverage details and available financing programs to facilitate system upgrade decision.
Dave T.
Dave T. Checked in
Provided comprehensive estimate for complete central air conditioning system replacement. Existing outdoor condensing unit is over 10 years old, has required repairs in two consecutive years, and is currently non-operational. Evaluated existing equipment configuration, photographed current installation showing outdoor unit on concrete pad with refrigerant lines running to building, and assessed replacement requirements. Presented equipment options with warranty coverage details and available financing programs to facilitate system upgrade decision.
Canton, OH 44721
Addressed multiple electrical code violations identified during city inspection. Corrected improper wire splice in basement area, removed unsafe hanging receptacle, and installed GFCI protection on exterior bell box for enhanced safety and code compliance. Added wireless three-way switch system to control pull-chain light fixture serving attic access stairway, improving functionality and convenience. All work completed to meet current electrical code requirements and pass final inspection.
Addressed multiple electrical code violations identified during city inspection. Corrected improper wire splice in basement area, removed unsafe hanging receptacle, and installed GFCI protection on exterior bell box for enhanced safety and code compliance. Added wireless three-way switch system to control pull-chain light fixture serving attic access stairway, improving functionality and convenience. All work completed to meet current electrical code requirements and pass final inspection.
Austin B.
Austin B. Checked in
Addressed multiple electrical code violations identified during city inspection. Corrected improper wire splice in basement area, removed unsafe hanging receptacle, and installed GFCI protection on exterior bell box for enhanced safety and code compliance. Added wireless three-way switch system to control pull-chain light fixture serving attic access stairway, improving functionality and convenience. All work completed to meet current electrical code requirements and pass final inspection.
Canton, OH 44706
Completed comprehensive tune-up on 10-year-old Lennox air conditioning system, including outdoor condenser unit and indoor furnace. Performed standard maintenance procedures: inspected electrical connections and disconnect box, cleaned condenser coils, checked refrigerant levels, tested capacitor and contactor operation, verified proper airflow through ventilation fins, examined condensate drain lines and PVC venting system, inspected ductwork connections, and confirmed all safety controls were functioning correctly. System operating within manufacturer specifications with no deficiencies noted at time of service.
Completed comprehensive tune-up on 10-year-old Lennox air conditioning system, including outdoor condenser unit and indoor furnace. Performed standard maintenance procedures: inspected electrical connections and disconnect box, cleaned condenser coils, checked refrigerant levels, tested capacitor and contactor operation, verified proper airflow through ventilation fins, examined condensate drain lines and PVC venting system, inspected ductwork connections, and confirmed all safety controls were functioning correctly. System operating within manufacturer specifications with no deficiencies noted at time of service.
William S.
William S. Checked in
Completed comprehensive tune-up on 10-year-old Lennox air conditioning system, including outdoor condenser unit and indoor furnace. Performed standard maintenance procedures: inspected electrical connections and disconnect box, cleaned condenser coils, checked refrigerant levels, tested capacitor and contactor operation, verified proper airflow through ventilation fins, examined condensate drain lines and PVC venting system, inspected ductwork connections, and confirmed all safety controls were functioning correctly. System operating within manufacturer specifications with no deficiencies noted at time of service.
Canton, OH 44718
Canton, OH - Responded to service call for non-operational sump pump system. Upon arrival, inspected submersible pump assembly in basement sump pit and evaluated discharge piping configuration. Performed diagnostic testing on pump motor and electrical connections to identify failure cause. Verified proper pump operation, checked float switch functionality, and ensured adequate discharge flow through PVC piping system. System restored to normal working condition.
Travis B.
Travis B. Checked in
Responded to service call for non-operational sump pump system. Upon arrival, inspected submersible pump assembly in basement sump pit and evaluated discharge piping configuration. Performed diagnostic testing on pump motor and electrical connections to identify failure cause. Verified proper pump operation, checked float switch functionality, and ensured adequate discharge flow through PVC piping system. System restored to normal working condition.
Canton, OH 44714
Completed MVP recurring cooling maintenance visit. Inspected HVAC system and replaced heavily soiled cylindrical air filter that exhibited significant dust and debris accumulation throughout pleated media. Verified electrical components, capacitor, and control board within unit are functioning properly with all wire connections secure.
Completed MVP recurring cooling maintenance visit. Inspected HVAC system and replaced heavily soiled cylindrical air filter that exhibited significant dust and debris accumulation throughout pleated media. Verified electrical components, capacitor, and control board within unit are functioning properly with all wire connections secure.
Colton D.
Colton D. Checked in
Completed MVP recurring cooling maintenance visit. Inspected HVAC system and replaced heavily soiled cylindrical air filter that exhibited significant dust and debris accumulation throughout pleated media. Verified electrical components, capacitor, and control board within unit are functioning properly with all wire connections secure.
Canton, OH 44709

 

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image