Schedule Service

HVAC, Plumbing & Electrical in Cuyahoga Falls, OH

When you need the best home services in Cuyahoga Falls, trust the team at Blind & Sons. With over 80 years in business, our team of experts offers comprehensive HVAC, plumbing, and electrical services to ensure your home is functional and comfortable.

Our highly trained technicians are the best in the industry, and we stand behind our work with unmatched warranties and guarantees. That’s why we’re known to meet your needs and exceed your expectations!

Schedule HVAC, plumbing, or electrical services today by calling Blind & Sons at 330-362-9232!

An expert plumber skillfully repairs a leaking pipe using a tool.

Same-Day Cooling Services

Stay comfortable during the muggy season with our superior cooling services. We’re proud to offer installation, replacement, repair, and maintenance on various systems, including central air, heat pumps, and ductless mini-splits. With our extensive experience, we can handle it all, and with our available emergency AC repair, we’re there for you when you need us most!

Need Services?

Reliable Heating Services

Winters in Cuyahoga Falls can be bitterly cold and snowy. Stay warm and comfortable on even the coldest day of the year with our unmatched heating services. From installation and maintenance to repair and replacement, our skilled technicians have the tools and training to provide outstanding service for various system types, including furnaces, boilers, and Hybrid Heat. Are you stuck without heat due to a breakdown? Trust our emergency heating repair service to restore your system quickly!

Stay warm all winter by scheduling a heating service with Blind & Sons at 330-362-9232!

Air Quality Services in Cuyahoga Falls

Enjoy your time inside with indoor air quality services from Blind & Sons. Our solutions can help improve your comfort & health with services and products, including:

To schedule indoor air quality services, call 330-362-9232 today!

Dependable Electrical Services

For safe and reliable electrical services, trust the licensed electricians at Blind & Sons. Our comprehensive electrical services include general installation, replacement, repair, electrical panel services, and rewiring. We also offer specialized services, including electrical inspections, whole-home generators, EV chargers, and more!

Call Blind & Sons today at 330-362-9232 to schedule your next electrical service with our team!

Top-Rated Plumbing Services

Keep your plumbing system operating at peak performance with plumbing services from Blind & Sons. Our expert plumbers are here to handle even the most complex repairs to help protect your home from water damage and ensure that you have the reliable plumbing you need.

We also provide comprehensive water heater services for standard and tankless systems to ensure you can access the hot water you need. Plus, with drain cleaning services, we’ll remove stubborn clogs to ensure your pipes can flow freely!

Trust the plumbers at Blind & Sons! Call 330-362-9232 today to schedule service!

Choose Blind & Sons in Cuyahoga Falls

Since 1937, Blind & Sons has provided outstanding HVAC, plumbing, and electrical service to the residents of Cuyahoga Falls and Northeast Ohio. We’re proud to offer emergency heating and cooling services to ensure our customers’ comfort is never compromised. Plus, with our satisfaction guarantee, you can trust you’re only getting the best possible service from our team!

Call 330-362-9232 today to schedule HVAC, plumbing, or electrical services for your Cuyahoga Falls home!

 

Recent Jobs and Reviews in Cuyahoga Falls, OH

Cuyahoga Falls, OH at a glance

Blind and Sons has completed 20 jobs in Cuyahoga Falls, OH in November 2026.

The most recent job was on November 9, 2026.

Blind and Sons has completed 958 jobs in Cuyahoga Falls, OH in the last 12 months.

Job Locations and Reviews

Responded to a furnace service call for abnormal noise and odor, performing a diagnostic inspection with a borescope camera of the internal ductwork and heat exchanger/plenum area. Inspection revealed a visible crack in the interior surface along with crinkled, displaced foil insulation material, which are likely sources of the noise and smell. Findings were documented with photos, and further repair or component replacement is recommended to restore safe, proper operation.
Responded to a furnace service call for abnormal noise and odor, performing a diagnostic inspection with a borescope camera of the internal ductwork and heat exchanger/plenum area. Inspection revealed a visible crack in the interior surface along with crinkled, displaced foil insulation material, which are likely sources of the noise and smell. Findings were documented with photos, and further repair or component replacement is recommended to restore safe, proper operation.
Frank W.
Frank W. Checked in
Responded to a furnace service call for abnormal noise and odor, performing a diagnostic inspection with a borescope camera of the internal ductwork and heat exchanger/plenum area. Inspection revealed a visible crack in the interior surface along with crinkled, displaced foil insulation material, which are likely sources of the noise and smell. Findings were documented with photos, and further repair or component replacement is recommended to restore safe, proper operation.
Cuyahoga Falls, OH 44223
Installed a new 90% AFUE furnace and verified proper operation upon completion. Used a multi-probe digital temperature instrument to confirm supply and return air temperatures and check temperature rise across the heat exchanger, ensuring performance within manufacturer specifications.
Installed a new 90% AFUE furnace and verified proper operation upon completion. Used a multi-probe digital temperature instrument to confirm supply and return air temperatures and check temperature rise across the heat exchanger, ensuring performance within manufacturer specifications.
Jay E.
Jay E. Checked in
Installed a new 90% AFUE furnace and verified proper operation upon completion. Used a multi-probe digital temperature instrument to confirm supply and return air temperatures and check temperature rise across the heat exchanger, ensuring performance within manufacturer specifications.
Cuyahoga Falls, OH 44223
Cuyahoga Falls, OH - Installed a new city water softener system consisting of a fiberglass pressure tank with an Impression Plus digital control head and a brine tank, connected to the existing water supply and drain with PEX/poly tubing. Programmed the control valve, charged the brine tank with water softener salt, and verified proper regeneration cycle operation and system function with no leaks observed.
Nick L.
Nick L. Checked in
Installed a new city water softener system consisting of a fiberglass pressure tank with an Impression Plus digital control head and a brine tank, connected to the existing water supply and drain with PEX/poly tubing. Programmed the control valve, charged the brine tank with water softener salt, and verified proper regeneration cycle operation and system function with no leaks observed.
Cuyahoga Falls, OH 44223
Cuyahoga Falls, OH - Performed on-site evaluation of a 27-year-old upright gas furnace reported to be leaking water and documented unit condition, including condensate drain components, PVC venting, and adjacent supply plenum. Based on the unit's age and observed condition, recommended furnace replacement and prepared a replacement estimate for the customer's review.
Jordan K.
Jordan K. Checked in
Performed on-site evaluation of a 27-year-old upright gas furnace reported to be leaking water and documented unit condition, including condensate drain components, PVC venting, and adjacent supply plenum. Based on the unit's age and observed condition, recommended furnace replacement and prepared a replacement estimate for the customer's review.
Cuyahoga Falls, OH 44223
Cuyahoga Falls, OH - Replaced the failed hot surface igniter assembly on the furnace with a new OEM-compatible igniter, securing the mounting bracket and reconnecting the wiring harness. Verified proper igniter glow and ignition sequence, confirming the unit is restored to normal heating operation.
Daniel S.
Daniel S. Checked in
Replaced the failed hot surface igniter assembly on the furnace with a new OEM-compatible igniter, securing the mounting bracket and reconnecting the wiring harness. Verified proper igniter glow and ignition sequence, confirming the unit is restored to normal heating operation.
Cuyahoga Falls, OH 44223
Performed full preventive maintenance on the standby generator, including engine oil and filter service and spark plug replacement. Load-tested the battery with a digital battery analyzer, which returned a GOOD BATTERY result at 12.88V with low internal resistance, then cleared the "inspect battery" warning so the unit is ready for winter operation.
Performed full preventive maintenance on the standby generator, including engine oil and filter service and spark plug replacement. Load-tested the battery with a digital battery analyzer, which returned a GOOD BATTERY result at 12.88V with low internal resistance, then cleared the "inspect battery" warning so the unit is ready for winter operation.
Logan H.
Logan H. Checked in
Performed full preventive maintenance on the standby generator, including engine oil and filter service and spark plug replacement. Load-tested the battery with a digital battery analyzer, which returned a GOOD BATTERY result at 12.88V with low internal resistance, then cleared the "inspect battery" warning so the unit is ready for winter operation.
Cuyahoga Falls, OH 44223
Completed installation of a 90% AFUE gas furnace with matching AC system, including supply plenum and galvanized ductwork connections, condensate drain routing with PVC piping, and a code-compliant service disconnect with flexible metal conduit. Verified supply air temperature rise with a digital probe thermometer to confirm proper heating operation, and left the mechanical area clean and unobstructed.
Completed installation of a 90% AFUE gas furnace with matching AC system, including supply plenum and galvanized ductwork connections, condensate drain routing with PVC piping, and a code-compliant service disconnect with flexible metal conduit. Verified supply air temperature rise with a digital probe thermometer to confirm proper heating operation, and left the mechanical area clean and unobstructed.
Shae M.
Shae M. Checked in
Completed installation of a 90% AFUE gas furnace with matching AC system, including supply plenum and galvanized ductwork connections, condensate drain routing with PVC piping, and a code-compliant service disconnect with flexible metal conduit. Verified supply air temperature rise with a digital probe thermometer to confirm proper heating operation, and left the mechanical area clean and unobstructed.
Cuyahoga Falls, OH 44221
Cuyahoga Falls, OH - Replaced the failed gas valve on a Trane furnace after diagnosing it as the cause of the service issue. Isolated the gas and electrical supply, disconnected the wiring and gas connections, and installed a new valve. Reconnected the wiring, leak-tested all gas fittings, and verified proper ignition and burner operation. Noted heavy rust and corrosion on the manifold piping and discoloration on the cabinet interior, which should be monitored.
Kevin D.
Kevin D. Checked in
Replaced the failed gas valve on a Trane furnace after diagnosing it as the cause of the service issue. Isolated the gas and electrical supply, disconnected the wiring and gas connections, and installed a new valve. Reconnected the wiring, leak-tested all gas fittings, and verified proper ignition and burner operation. Noted heavy rust and corrosion on the manifold piping and discoloration on the cabinet interior, which should be monitored.
Cuyahoga Falls, OH 44223
Performed an on-site evaluation of a 16-year-old Rinnai tankless water heater for a replacement estimate; no service call was required. The unit remains operational, displaying a 125°F set temperature, with PVC venting, flexible gas supply, and hot and cold water isolation valves intact. Minor surface rust was noted on the housing and the wall shows some staining, but no leaks, breakage, or major corrosion were observed.
Performed an on-site evaluation of a 16-year-old Rinnai tankless water heater for a replacement estimate; no service call was required. The unit remains operational, displaying a 125°F set temperature, with PVC venting, flexible gas supply, and hot and cold water isolation valves intact. Minor surface rust was noted on the housing and the wall shows some staining, but no leaks, breakage, or major corrosion were observed.
Craig S.
Craig S. Checked in
Performed an on-site evaluation of a 16-year-old Rinnai tankless water heater for a replacement estimate; no service call was required. The unit remains operational, displaying a 125°F set temperature, with PVC venting, flexible gas supply, and hot and cold water isolation valves intact. Minor surface rust was noted on the housing and the wall shows some staining, but no leaks, breakage, or major corrosion were observed.
Cuyahoga Falls, OH 44223
Performed scheduled heating maintenance, including removal and inspection of the flame sensor, which showed oxidation and discoloration from heat exposure, and cleaned it to restore proper flame rectification. Replaced the heavily loaded 20x20x1 pleated return air filter to restore airflow and protect the blower and heat exchanger. Inspected the furnace cabinet, wiring harness, and condensate PVC piping, and noted corrosion on the adjacent threaded gas/water piping for monitoring.
Performed scheduled heating maintenance, including removal and inspection of the flame sensor, which showed oxidation and discoloration from heat exposure, and cleaned it to restore proper flame rectification. Replaced the heavily loaded 20x20x1 pleated return air filter to restore airflow and protect the blower and heat exchanger. Inspected the furnace cabinet, wiring harness, and condensate PVC piping, and noted corrosion on the adjacent threaded gas/water piping for monitoring.
Kevin D.
Kevin D. Checked in
Performed scheduled heating maintenance, including removal and inspection of the flame sensor, which showed oxidation and discoloration from heat exposure, and cleaned it to restore proper flame rectification. Replaced the heavily loaded 20x20x1 pleated return air filter to restore airflow and protect the blower and heat exchanger. Inspected the furnace cabinet, wiring harness, and condensate PVC piping, and noted corrosion on the adjacent threaded gas/water piping for monitoring.
Cuyahoga Falls, OH 44223
Performed seasonal heating maintenance on a Lennox gas furnace, including inspection of the flue and PVC vent piping, gas supply line, and control wiring. Conducted combustion analysis on natural gas, with results of 6.5% O2, 8.1% CO2, 32 ppm CO, and 92.3% efficiency, confirming the furnace is operating within normal combustion parameters.
Performed seasonal heating maintenance on a Lennox gas furnace, including inspection of the flue and PVC vent piping, gas supply line, and control wiring. Conducted combustion analysis on natural gas, with results of 6.5% O2, 8.1% CO2, 32 ppm CO, and 92.3% efficiency, confirming the furnace is operating within normal combustion parameters.
Derrick M.
Derrick M. Checked in
Performed seasonal heating maintenance on a Lennox gas furnace, including inspection of the flue and PVC vent piping, gas supply line, and control wiring. Conducted combustion analysis on natural gas, with results of 6.5% O2, 8.1% CO2, 32 ppm CO, and 92.3% efficiency, confirming the furnace is operating within normal combustion parameters.
Cuyahoga Falls, OH 44221
Performed MVP maintenance on two gas furnaces, inspecting the inducer motor and capacitor, gas valve assembly, pressure switch, and wiring harnesses for secure connections, proper routing, and signs of wear. Examined the integrated control boards, relays, and terminal connections, and noted worn electrical tape on the main wiring bundle. Cleaned light dust and grime from cabinet components, and found no evidence of rust, frost, or breakage. Both units were left in good operating condition.
Performed MVP maintenance on two gas furnaces, inspecting the inducer motor and capacitor, gas valve assembly, pressure switch, and wiring harnesses for secure connections, proper routing, and signs of wear. Examined the integrated control boards, relays, and terminal connections, and noted worn electrical tape on the main wiring bundle. Cleaned light dust and grime from cabinet components, and found no evidence of rust, frost, or breakage. Both units were left in good operating condition.
Stephanie E.
Stephanie E. Checked in
Performed MVP maintenance on two gas furnaces, inspecting the inducer motor and capacitor, gas valve assembly, pressure switch, and wiring harnesses for secure connections, proper routing, and signs of wear. Examined the integrated control boards, relays, and terminal connections, and noted worn electrical tape on the main wiring bundle. Cleaned light dust and grime from cabinet components, and found no evidence of rust, frost, or breakage. Both units were left in good operating condition.
Cuyahoga Falls, OH 44221
Performed scheduled heating maintenance on a 13-year-old natural gas furnace, including a combustion analysis that showed O2 at 12.1%, CO at 54 ppm, CO2 at 5.0%, and 97.9% efficiency. The furnace cabinet, PVC vent and intake piping, condensate drain line, and ductwork were inspected with no frost, ice, or significant rust observed, and the unit was left operating normally.
Performed scheduled heating maintenance on a 13-year-old natural gas furnace, including a combustion analysis that showed O2 at 12.1%, CO at 54 ppm, CO2 at 5.0%, and 97.9% efficiency. The furnace cabinet, PVC vent and intake piping, condensate drain line, and ductwork were inspected with no frost, ice, or significant rust observed, and the unit was left operating normally.
Derrick M.
Derrick M. Checked in
Performed scheduled heating maintenance on a 13-year-old natural gas furnace, including a combustion analysis that showed O2 at 12.1%, CO at 54 ppm, CO2 at 5.0%, and 97.9% efficiency. The furnace cabinet, PVC vent and intake piping, condensate drain line, and ductwork were inspected with no frost, ice, or significant rust observed, and the unit was left operating normally.
Cuyahoga Falls, OH 44221
Performed a seasonal tune-up on a Goodman GMSS920603BNAA gas furnace, including inspection of the cabinet interior, burner assembly, and flame sensor, which was cleaned of accumulated residue to ensure reliable flame rectification. Verified safe, proper operation of the unit along with its venting and associated ductwork.
Performed a seasonal tune-up on a Goodman GMSS920603BNAA gas furnace, including inspection of the cabinet interior, burner assembly, and flame sensor, which was cleaned of accumulated residue to ensure reliable flame rectification. Verified safe, proper operation of the unit along with its venting and associated ductwork.
Derrick M.
Derrick M. Checked in
Performed a seasonal tune-up on a Goodman GMSS920603BNAA gas furnace, including inspection of the cabinet interior, burner assembly, and flame sensor, which was cleaned of accumulated residue to ensure reliable flame rectification. Verified safe, proper operation of the unit along with its venting and associated ductwork.
Cuyahoga Falls, OH 44223
Responded to a furnace error code call and inspected the SureLight integrated furnace control board and surrounding low-voltage wiring, terminal connections, and harness plugs. The board and connections showed no visible damage, corrosion, or burn marks, and the system's diagnostic fault code was reviewed to verify operation.
Responded to a furnace error code call and inspected the SureLight integrated furnace control board and surrounding low-voltage wiring, terminal connections, and harness plugs. The board and connections showed no visible damage, corrosion, or burn marks, and the system's diagnostic fault code was reviewed to verify operation.
Jibreel H.
Jibreel H. Checked in
Responded to a furnace error code call and inspected the SureLight integrated furnace control board and surrounding low-voltage wiring, terminal connections, and harness plugs. The board and connections showed no visible damage, corrosion, or burn marks, and the system's diagnostic fault code was reviewed to verify operation.
Cuyahoga Falls, OH 44223
Performed seasonal heating maintenance on a 9-year-old Lennox gas furnace, inspecting the inducer motor, gas valve assembly, and wiring connections and confirming proper condition with no frost, rust, or other visible anomalies. Verified flue piping, condensate/PVC drain components, and gas supply connections were secure, and the unit was left operating normally and ready for the heating season.
Performed seasonal heating maintenance on a 9-year-old Lennox gas furnace, inspecting the inducer motor, gas valve assembly, and wiring connections and confirming proper condition with no frost, rust, or other visible anomalies. Verified flue piping, condensate/PVC drain components, and gas supply connections were secure, and the unit was left operating normally and ready for the heating season.
Jibreel H.
Jibreel H. Checked in
Performed seasonal heating maintenance on a 9-year-old Lennox gas furnace, inspecting the inducer motor, gas valve assembly, and wiring connections and confirming proper condition with no frost, rust, or other visible anomalies. Verified flue piping, condensate/PVC drain components, and gas supply connections were secure, and the unit was left operating normally and ready for the heating season.
Cuyahoga Falls, OH 44223
Performed annual maintenance on a 3-year-old gas furnace, including inspection of the air handler cabinet, filter, condensate pump, and associated ductwork and venting, with no signs of rust, frost, or damage observed. Unit is operating normally. Customer requested a quote for a whole-home humidifier installation.
Performed annual maintenance on a 3-year-old gas furnace, including inspection of the air handler cabinet, filter, condensate pump, and associated ductwork and venting, with no signs of rust, frost, or damage observed. Unit is operating normally. Customer requested a quote for a whole-home humidifier installation.
John W.
John W. Checked in
Performed annual maintenance on a 3-year-old gas furnace, including inspection of the air handler cabinet, filter, condensate pump, and associated ductwork and venting, with no signs of rust, frost, or damage observed. Unit is operating normally. Customer requested a quote for a whole-home humidifier installation.
Cuyahoga Falls, OH 44221
Performed seasonal heating maintenance on a 10-year-old natural gas furnace, including a combustion analysis that recorded O2 at 5.3%, CO at 65 ppm, CO2 at 8.8%, and steady-state efficiency of 93.2%. Cleared accumulated leaves and debris from the top of the equipment cabinet around the condensate drain and PVC fitting to maintain proper drainage and unobstructed airflow.
Performed seasonal heating maintenance on a 10-year-old natural gas furnace, including a combustion analysis that recorded O2 at 5.3%, CO at 65 ppm, CO2 at 8.8%, and steady-state efficiency of 93.2%. Cleared accumulated leaves and debris from the top of the equipment cabinet around the condensate drain and PVC fitting to maintain proper drainage and unobstructed airflow.
Stephanie E.
Stephanie E. Checked in
Performed seasonal heating maintenance on a 10-year-old natural gas furnace, including a combustion analysis that recorded O2 at 5.3%, CO at 65 ppm, CO2 at 8.8%, and steady-state efficiency of 93.2%. Cleared accumulated leaves and debris from the top of the equipment cabinet around the condensate drain and PVC fitting to maintain proper drainage and unobstructed airflow.
Cuyahoga Falls, OH 44223
Performed a system inspection and verified the furnace was operating within factory tolerances. Identified a corroded galvanized flue pipe and recommended replacement, and the required parts have been ordered and received for the repair.
Performed a system inspection and verified the furnace was operating within factory tolerances. Identified a corroded galvanized flue pipe and recommended replacement, and the required parts have been ordered and received for the repair.
John W.
John W. Checked in
Performed a system inspection and verified the furnace was operating within factory tolerances. Identified a corroded galvanized flue pipe and recommended replacement, and the required parts have been ordered and received for the repair.
Cuyahoga Falls, OH 44223
Performed annual MVP maintenance on the gas furnace, including removal of the front access panel to inspect the blower motor, gas valve assembly, control board, and wiring harness connections. Verified the condensate/PVC venting, gas supply piping, and line-voltage conduit connections were secure and free of visible corrosion or damage, and inspected the AprilAire air cleaner cabinet and filter. The system was reassembled and left in proper working order, with a faint damp patch on the floor in front of the furnace noted for monitoring.
Performed annual MVP maintenance on the gas furnace, including removal of the front access panel to inspect the blower motor, gas valve assembly, control board, and wiring harness connections. Verified the condensate/PVC venting, gas supply piping, and line-voltage conduit connections were secure and free of visible corrosion or damage, and inspected the AprilAire air cleaner cabinet and filter. The system was reassembled and left in proper working order, with a faint damp patch on the floor in front of the furnace noted for monitoring.
Frank W.
Frank W. Checked in
Performed annual MVP maintenance on the gas furnace, including removal of the front access panel to inspect the blower motor, gas valve assembly, control board, and wiring harness connections. Verified the condensate/PVC venting, gas supply piping, and line-voltage conduit connections were secure and free of visible corrosion or damage, and inspected the AprilAire air cleaner cabinet and filter. The system was reassembled and left in proper working order, with a faint damp patch on the floor in front of the furnace noted for monitoring.
Cuyahoga Falls, OH 44223

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image