Schedule Service

Air Conditioning, Heating, Electrical & Plumbing Services in Uniontown, OH

When you’re looking for a company to install, repair, and maintain all your HVAC, plumbing, and electrical systems in one fell swoop, there’s no need to worry about scheduling appointments with different service companies. At Blind & Sons, we handle it all! From leaky faucets and power outages to broken air conditioners and worn-out heaters.

Get everything you need for your Uniontown home from Blind & Sons! Call 330-362-9232 or contact us online for HVAC, electrical, or plumbing services today.

Air Conditioning Services

Air conditioning units

Your home is supposed to be a comfortable haven, but it becomes inconvenient when you can’t cool off or stay indoors because your air conditioner isn’t working correctly. A broken AC can also lead to other issues, including excessive humidity, which can result in mold growth and mildew. To keep your home from feeling like a swamp, our technicians can perform high-quality AC services, including:

Contact Blind & Sons online today or call 330-362-9232 to schedule a cooling service in Uniontown.

Need Services?

Heating Services

Depending on your heating unit, it can be tricky to know when it’s time to have it serviced by a professional. A few signs to look out for include excessive dust in your home when using your heater, little to no heat being produced, or if your pilot light is discolored. If one or more of these issues are happening with your heating unit, our technicians can get the job done in no time. Our heating specialists perform:

Make warm and cozy a default setting in your Uniontown home. Give us a call at 330-362-9232 or reach out to us online to schedule a heating service.

Indoor Air Quality Services

Indoor air quality is an often overlooked but deeply concerning issue for many homeowners. At Blind & Sons, we provide high-performance services that keep your home’s indoor air clean and safe to breathe using solutions, including:

Our indoor air quality services are guaranteed to clear your air of harmful particles, including pet dander, pollen, tobacco smoke, cleaning chemicals, and other airborne pathogens.

For help choosing the right indoor air quality solution for your home, call 330-362-9232 or contact Blind & Sons online for a free consultation.

Plumbing Services

Technician repairing water heater

When it comes to plumbing issues, every second counts. We offer plumbing repair services to protect your home from water damage, pipe damage, and other plumbing issues. To meet all your plumbing needs, we provide a wide range of plumbing services, including:

No plumbing issue is too much for our plumbing experts to handle. Get the help you need and call 330-362-9232 or contact Blind & Sons online to schedule a plumbing service in the Uniontown area.

Electrical Services

When experiencing problems with your electrical wiring, it can be dangerous to tackle it on your own if you don’t have experience or knowledge of electrical systems. To keep you and your loved ones safe, hire our professional electricians to take on the job. Whether you need new electrical wiring installed, have your old wiring repaired or maintained, or want extra protection in case of emergencies, we offer:

Avoid electrical fires and other electricity-related issues when you choose Blind & Sons. Reach out to us online or call 330-362-9232 to schedule an electrical service in Uniontown.

Why Choose Blind & Sons?

When it comes to the most high-quality plumbing, HVAC, and electrical services around, no better company does it better than Blind & Sons. With our online scheduling, we make getting services a breeze. We also offer a 100% satisfaction guarantee or your money back. So, what are you waiting for? Long-lasting comfort is just a phone call away!

Call us at 330-362-9232 or contact Blind & Sons online to schedule a plumbing, HVAC, or electrical service in Uniontown today.

Related Blogs:

 

Recent Jobs and Reviews in Uniontown, OH

Uniontown, OH at a glance

Blind and Sons has completed 20 jobs in Uniontown, OH in November 2026.

The most recent job was on November 24, 2026.

Blind and Sons has completed 408 jobs in Uniontown, OH in the last 12 months.

Job Locations and Reviews

Responded to a leaking washroom utility tub and replaced the leaking supply components using the customer-provided copper piping, brass gate valves, and fittings with PTFE thread seal. The existing faucet and supply piping showed heavy corrosion and verdigris buildup consistent with an aged installation, and the connections were reassembled and checked for leaks.
Responded to a leaking washroom utility tub and replaced the leaking supply components using the customer-provided copper piping, brass gate valves, and fittings with PTFE thread seal. The existing faucet and supply piping showed heavy corrosion and verdigris buildup consistent with an aged installation, and the connections were reassembled and checked for leaks.
Craig S.
Craig S. Checked in
Responded to a leaking washroom utility tub and replaced the leaking supply components using the customer-provided copper piping, brass gate valves, and fittings with PTFE thread seal. The existing faucet and supply piping showed heavy corrosion and verdigris buildup consistent with an aged installation, and the connections were reassembled and checked for leaks.
Uniontown, OH 44685
Performed a heating maintenance tune-up on the Lennox furnace, including inspection of the control board, wiring connections, and flame sensor/probe assembly inside the cabinet, with no visible rust, frost, breakage, or damage observed. Also inspected the whole-home humidifier mounted on the supply duct, including its water supply valve and hose connection, and found no visible damage or leaks. System operating condition was verified at completion of the tune-up.
Performed a heating maintenance tune-up on the Lennox furnace, including inspection of the control board, wiring connections, and flame sensor/probe assembly inside the cabinet, with no visible rust, frost, breakage, or damage observed. Also inspected the whole-home humidifier mounted on the supply duct, including its water supply valve and hose connection, and found no visible damage or leaks. System operating condition was verified at completion of the tune-up.
Matthew F.
Matthew F. Checked in
Performed a heating maintenance tune-up on the Lennox furnace, including inspection of the control board, wiring connections, and flame sensor/probe assembly inside the cabinet, with no visible rust, frost, breakage, or damage observed. Also inspected the whole-home humidifier mounted on the supply duct, including its water supply valve and hose connection, and found no visible damage or leaks. System operating condition was verified at completion of the tune-up.
Uniontown, OH 44685
Performed annual maintenance on a 9-year-old gas furnace, inspecting the inducer motor assembly, gas valve, pressure switch, control board wiring, and hot surface igniter, with no frost or heavy rust observed. The pleated air filter was found dirty with visible dust buildup and discoloration, and the unit's wiring and components were checked for proper connections.
Performed annual maintenance on a 9-year-old gas furnace, inspecting the inducer motor assembly, gas valve, pressure switch, control board wiring, and hot surface igniter, with no frost or heavy rust observed. The pleated air filter was found dirty with visible dust buildup and discoloration, and the unit's wiring and components were checked for proper connections.
Daniel
Daniel Checked in
Performed annual maintenance on a 9-year-old gas furnace, inspecting the inducer motor assembly, gas valve, pressure switch, control board wiring, and hot surface igniter, with no frost or heavy rust observed. The pleated air filter was found dirty with visible dust buildup and discoloration, and the unit's wiring and components were checked for proper connections.
Uniontown, OH 44685
Performed an on-site electrical estimate for a standby generator installation, inspecting the main electrical panel and surrounding service area. The panel interior was in good condition with no visible rust, burn marks, or physical damage, and available breaker spaces and circuit directory were reviewed for generator transfer switch integration. Also noted the nearby gas supply line and wiring routing in the basement ceiling to assess feasibility of the generator connection.
Performed an on-site electrical estimate for a standby generator installation, inspecting the main electrical panel and surrounding service area. The panel interior was in good condition with no visible rust, burn marks, or physical damage, and available breaker spaces and circuit directory were reviewed for generator transfer switch integration. Also noted the nearby gas supply line and wiring routing in the basement ceiling to assess feasibility of the generator connection.
Eric L.
Eric L. Checked in
Performed an on-site electrical estimate for a standby generator installation, inspecting the main electrical panel and surrounding service area. The panel interior was in good condition with no visible rust, burn marks, or physical damage, and available breaker spaces and circuit directory were reviewed for generator transfer switch integration. Also noted the nearby gas supply line and wiring routing in the basement ceiling to assess feasibility of the generator connection.
Uniontown, OH 44685
Performed scheduled maintenance on a 6-year-old natural gas furnace, including a combustion analysis that recorded O₂ at 10.1%, CO at 21 ppm, CO₂ at 6.1%, and steady-state efficiency of 76.7%. Inspected the blower/vent louvers, which showed light dust and grime buildup, with no rust, cracking, or other damage observed.
Performed scheduled maintenance on a 6-year-old natural gas furnace, including a combustion analysis that recorded O₂ at 10.1%, CO at 21 ppm, CO₂ at 6.1%, and steady-state efficiency of 76.7%. Inspected the blower/vent louvers, which showed light dust and grime buildup, with no rust, cracking, or other damage observed.
Stephanie E.
Stephanie E. Checked in
Performed scheduled maintenance on a 6-year-old natural gas furnace, including a combustion analysis that recorded O₂ at 10.1%, CO at 21 ppm, CO₂ at 6.1%, and steady-state efficiency of 76.7%. Inspected the blower/vent louvers, which showed light dust and grime buildup, with no rust, cracking, or other damage observed.
Uniontown, OH 44685
Performed scheduled heating maintenance on a 15-year-old gas furnace, including inspection of the ignition and flame sensing components, with the sensor rod showing carbon buildup and oxidation from heat exposure. Inspection of the cabinet also revealed heavy rust and green corrosion on the iron piping and union fitting, indicating a potential leak or moisture issue that should be monitored.
Performed scheduled heating maintenance on a 15-year-old gas furnace, including inspection of the ignition and flame sensing components, with the sensor rod showing carbon buildup and oxidation from heat exposure. Inspection of the cabinet also revealed heavy rust and green corrosion on the iron piping and union fitting, indicating a potential leak or moisture issue that should be monitored.
Colton D.
Colton D. Checked in
Performed scheduled heating maintenance on a 15-year-old gas furnace, including inspection of the ignition and flame sensing components, with the sensor rod showing carbon buildup and oxidation from heat exposure. Inspection of the cabinet also revealed heavy rust and green corrosion on the iron piping and union fitting, indicating a potential leak or moisture issue that should be monitored.
Uniontown, OH 44685
Performed annual heating maintenance on a one-year-old gas furnace, including inspection of the control board and low-voltage thermostat wiring connections at the terminal block (W1, W2, Y2, DH, H, L, O, DS), which were found secure with no signs of frost, rust, or cracking. Inspected the flame sensor rod and ceramic insulator, noting surface discoloration and light rust on the rod tip consistent with normal oxidation.
Performed annual heating maintenance on a one-year-old gas furnace, including inspection of the control board and low-voltage thermostat wiring connections at the terminal block (W1, W2, Y2, DH, H, L, O, DS), which were found secure with no signs of frost, rust, or cracking. Inspected the flame sensor rod and ceramic insulator, noting surface discoloration and light rust on the rod tip consistent with normal oxidation.
Colton D.
Colton D. Checked in
Performed annual heating maintenance on a one-year-old gas furnace, including inspection of the control board and low-voltage thermostat wiring connections at the terminal block (W1, W2, Y2, DH, H, L, O, DS), which were found secure with no signs of frost, rust, or cracking. Inspected the flame sensor rod and ceramic insulator, noting surface discoloration and light rust on the rod tip consistent with normal oxidation.
Uniontown, OH 44685
Performed scheduled heating maintenance on a one-year-old system. Inspected the blower assembly and coil, finding a uniform layer of dust and lint on the squirrel-cage blower wheel blades and heavy dust and debris matting the coil fins, with no cracks, rust, or frost observed. Documented these conditions with photos.
Performed scheduled heating maintenance on a one-year-old system. Inspected the blower assembly and coil, finding a uniform layer of dust and lint on the squirrel-cage blower wheel blades and heavy dust and debris matting the coil fins, with no cracks, rust, or frost observed. Documented these conditions with photos.
Stephanie E.
Stephanie E. Checked in
Performed scheduled heating maintenance on a one-year-old system. Inspected the blower assembly and coil, finding a uniform layer of dust and lint on the squirrel-cage blower wheel blades and heavy dust and debris matting the coil fins, with no cracks, rust, or frost observed. Documented these conditions with photos.
Uniontown, OH 44685
Performed seasonal heating maintenance on a natural gas furnace, including combustion analysis with a calibrated analyzer showing O2 at 6.9%, CO at 19 ppm, CO2 at 7.9%, and steady-state efficiency of 90.6%. During inspection of the furnace cabinet, found heavy corrosion and rust staining on the metal panel adjacent to the draft inducer motor, indicating possible moisture or condensate intrusion that should be further evaluated.
Performed seasonal heating maintenance on a natural gas furnace, including combustion analysis with a calibrated analyzer showing O2 at 6.9%, CO at 19 ppm, CO2 at 7.9%, and steady-state efficiency of 90.6%. During inspection of the furnace cabinet, found heavy corrosion and rust staining on the metal panel adjacent to the draft inducer motor, indicating possible moisture or condensate intrusion that should be further evaluated.
Stephanie E.
Stephanie E. Checked in
Performed seasonal heating maintenance on a natural gas furnace, including combustion analysis with a calibrated analyzer showing O2 at 6.9%, CO at 19 ppm, CO2 at 7.9%, and steady-state efficiency of 90.6%. During inspection of the furnace cabinet, found heavy corrosion and rust staining on the metal panel adjacent to the draft inducer motor, indicating possible moisture or condensate intrusion that should be further evaluated.
Uniontown, OH 44685
Performed annual tune-up on an oil-fired furnace. Inspected the flue/vent connection and draft regulator, noting soot and rust-colored deposits on the interior flue surfaces. Verified the system's operation as part of the maintenance visit.
Performed annual tune-up on an oil-fired furnace. Inspected the flue/vent connection and draft regulator, noting soot and rust-colored deposits on the interior flue surfaces. Verified the system's operation as part of the maintenance visit.
William S.
William S. Checked in
Performed annual tune-up on an oil-fired furnace. Inspected the flue/vent connection and draft regulator, noting soot and rust-colored deposits on the interior flue surfaces. Verified the system's operation as part of the maintenance visit.
Uniontown, OH 44685
Performed a scheduled heating maintenance inspection on the air handler/furnace, including a visual check of the control board, DIP switch settings, outdoor sensor connections, wiring harnesses, and terminal connections, all of which were found secure and properly bundled. Noted heavy dust and lint buildup on the cabinet's interior lining material near the blower housing.
Performed a scheduled heating maintenance inspection on the air handler/furnace, including a visual check of the control board, DIP switch settings, outdoor sensor connections, wiring harnesses, and terminal connections, all of which were found secure and properly bundled. Noted heavy dust and lint buildup on the cabinet's interior lining material near the blower housing.
Derrick M.
Derrick M. Checked in
Performed a scheduled heating maintenance inspection on the air handler/furnace, including a visual check of the control board, DIP switch settings, outdoor sensor connections, wiring harnesses, and terminal connections, all of which were found secure and properly bundled. Noted heavy dust and lint buildup on the cabinet's interior lining material near the blower housing.
Uniontown, OH 44685
Uniontown, OH - Performed a seasonal tune-up on the heat pump system. Inspected the accompanying gas furnace with the lower front panel removed, exposing the burner compartment and blower assembly for inspection; the gas supply line with shutoff valve, PVC condensate and venting connections, flexible connectors, and foil-sealed ductwork were all in place with no visible rust, frost, or damage.
William S.
William S. Checked in
Performed a seasonal tune-up on the heat pump system. Inspected the accompanying gas furnace with the lower front panel removed, exposing the burner compartment and blower assembly for inspection; the gas supply line with shutoff valve, PVC condensate and venting connections, flexible connectors, and foil-sealed ductwork were all in place with no visible rust, frost, or damage.
Uniontown, OH 44685
Uniontown, OH - Diagnosed a 6-year-old gas furnace short cycling every 5-10 minutes with a no-heat complaint. Performed combustion analysis on natural gas, recording O2 at 8.7%, CO at 22 ppm, CO2 at 6.9%, and 97.9% efficiency, and used a clamp meter to verify electrical operation of the system components. Combustion readings were within safe operating limits, and testing was conducted to isolate the cause of the cycling issue.
Daniel S.
Daniel S. Checked in
Diagnosed a 6-year-old gas furnace short cycling every 5-10 minutes with a no-heat complaint. Performed combustion analysis on natural gas, recording O2 at 8.7%, CO at 22 ppm, CO2 at 6.9%, and 97.9% efficiency, and used a clamp meter to verify electrical operation of the system components. Combustion readings were within safe operating limits, and testing was conducted to isolate the cause of the cycling issue.
Uniontown, OH 44685
Uniontown, OH - Responded to a furnace short-cycling complaint (unit ignites briefly, then shuts down, with temporary recovery after a power cycle). Removed the upper access panel and inspected the inducer motor, gas valve assembly, control board, and wiring harness to diagnose the intermittent ignition and flame-sense lockout condition. The unit was evaluated for proper operation, with no visible corrosion or damage found on the equipment.
John W.
John W. Checked in
Responded to a furnace short-cycling complaint (unit ignites briefly, then shuts down, with temporary recovery after a power cycle). Removed the upper access panel and inspected the inducer motor, gas valve assembly, control board, and wiring harness to diagnose the intermittent ignition and flame-sense lockout condition. The unit was evaluated for proper operation, with no visible corrosion or damage found on the equipment.
Uniontown, OH 44685
Uniontown, OH - Releveled the standby generator and its mounting pad, which had settled significantly on one side. Added and compacted gravel base material to restore a stable, level foundation, ensuring proper support and alignment of the generator enclosure against the structure. Restored the surrounding landscaping with fresh mulch following the repair.
Landon M.
Landon M. Checked in
Releveled the standby generator and its mounting pad, which had settled significantly on one side. Added and compacted gravel base material to restore a stable, level foundation, ensuring proper support and alignment of the generator enclosure against the structure. Restored the surrounding landscaping with fresh mulch following the repair.
Uniontown, OH 44685
Uniontown, OH - Performed an on-site evaluation for furnace replacement, inspecting the existing galvanized air handler/blower assembly installed in a closet and documenting its condition with photos. The unit showed heavy dust and debris accumulation, along with a weathered, discolored warning label, and the findings were recorded to support replacement equipment recommendations and proposal preparation.
Dave T.
Dave T. Checked in
Performed an on-site evaluation for furnace replacement, inspecting the existing galvanized air handler/blower assembly installed in a closet and documenting its condition with photos. The unit showed heavy dust and debris accumulation, along with a weathered, discolored warning label, and the findings were recorded to support replacement equipment recommendations and proposal preparation.
Uniontown, OH 44685
Performed seasonal heating tune-up on a 9-year-old furnace, including opening the cabinet and inspecting the control board, low-voltage wiring, relay/transformer, and connected control module for proper operation and secure connections. Noted loose, unsecured wiring and exposed wire nuts within the cabinet, along with dust accumulation and an unit set on concrete blocks; recommend wiring be properly secured and routed to prevent future electrical or performance issues.
Performed seasonal heating tune-up on a 9-year-old furnace, including opening the cabinet and inspecting the control board, low-voltage wiring, relay/transformer, and connected control module for proper operation and secure connections. Noted loose, unsecured wiring and exposed wire nuts within the cabinet, along with dust accumulation and an unit set on concrete blocks; recommend wiring be properly secured and routed to prevent future electrical or performance issues.
Daniel S.
Daniel S. Checked in
Performed seasonal heating tune-up on a 9-year-old furnace, including opening the cabinet and inspecting the control board, low-voltage wiring, relay/transformer, and connected control module for proper operation and secure connections. Noted loose, unsecured wiring and exposed wire nuts within the cabinet, along with dust accumulation and an unit set on concrete blocks; recommend wiring be properly secured and routed to prevent future electrical or performance issues.
Uniontown, OH 44685
Responded to a complaint of the furnace exhaust popping off the unit and inspected the venting using a borescope camera. The inspection revealed cracking and frost/ice buildup within the exhaust passage, indicating a deteriorated vent condition that is the likely cause of the separation and requires further repair or replacement of the affected components.
Responded to a complaint of the furnace exhaust popping off the unit and inspected the venting using a borescope camera. The inspection revealed cracking and frost/ice buildup within the exhaust passage, indicating a deteriorated vent condition that is the likely cause of the separation and requires further repair or replacement of the affected components.
John W.
John W. Checked in
Responded to a complaint of the furnace exhaust popping off the unit and inspected the venting using a borescope camera. The inspection revealed cracking and frost/ice buildup within the exhaust passage, indicating a deteriorated vent condition that is the likely cause of the separation and requires further repair or replacement of the affected components.
Uniontown, OH 44685
Responded to a no-heat call on a 3-year-old Lennox ML180UH090E48B gas furnace and performed a diagnostic inspection of the inducer motor assembly, pressure switch and hose, gas valve, control board, and wiring harness with the access panels removed. Documented the condition of the unit's components and wiring with photos; no visible damage, frost, or rust was observed. Unit is under 3-year Lennox warranty coverage.
Responded to a no-heat call on a 3-year-old Lennox ML180UH090E48B gas furnace and performed a diagnostic inspection of the inducer motor assembly, pressure switch and hose, gas valve, control board, and wiring harness with the access panels removed. Documented the condition of the unit's components and wiring with photos; no visible damage, frost, or rust was observed. Unit is under 3-year Lennox warranty coverage.
Jibreel H.
Jibreel H. Checked in
Responded to a no-heat call on a 3-year-old Lennox ML180UH090E48B gas furnace and performed a diagnostic inspection of the inducer motor assembly, pressure switch and hose, gas valve, control board, and wiring harness with the access panels removed. Documented the condition of the unit's components and wiring with photos; no visible damage, frost, or rust was observed. Unit is under 3-year Lennox warranty coverage.
Uniontown, OH 44685
Performed annual tune-up on 16-year-old Tempstar N9MPD080J16A2 80% gas furnace, including inspection of the heat exchanger, burners, blower assembly, and safety controls. Found the return air filter heavily loaded with dust and debris, restricting airflow, and flame sensor was discolored and oxidized; filter replacement and flame sensor cleaning or replacement were recommended to restore proper airflow and reliable flame sensing.
Performed annual tune-up on 16-year-old Tempstar N9MPD080J16A2 80% gas furnace, including inspection of the heat exchanger, burners, blower assembly, and safety controls. Found the return air filter heavily loaded with dust and debris, restricting airflow, and flame sensor was discolored and oxidized; filter replacement and flame sensor cleaning or replacement were recommended to restore proper airflow and reliable flame sensing.
Taylor F.
Taylor F. Checked in
Performed annual tune-up on 16-year-old Tempstar N9MPD080J16A2 80% gas furnace, including inspection of the heat exchanger, burners, blower assembly, and safety controls. Found the return air filter heavily loaded with dust and debris, restricting airflow, and flame sensor was discolored and oxidized; filter replacement and flame sensor cleaning or replacement were recommended to restore proper airflow and reliable flame sensing.
Uniontown, OH 44685

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…