When you need the best home services in Cuyahoga Falls, trust the team at Blind & Sons. With over 80 years in business, our team of experts offers comprehensive HVAC, plumbing, and electrical services to ensure your home is functional and comfortable.
Our highly trained technicians are the best in the industry, and we stand behind our work with unmatched warranties and guarantees. That’s why we’re known to meet your needs and exceed your expectations!
Schedule HVAC, plumbing, or electrical services today by calling Blind & Sons at 330-362-9232!

Same-Day Cooling Services
Stay comfortable during the muggy season with our superior cooling services. We’re proud to offer installation, replacement, repair, and maintenance on various systems, including central air, heat pumps, and ductless mini-splits. With our extensive experience, we can handle it all, and with our available emergency AC repair, we’re there for you when you need us most!
Need Services?
We Can Help!
Reliable Heating Services
Winters in Cuyahoga Falls can be bitterly cold and snowy. Stay warm and comfortable on even the coldest day of the year with our unmatched heating services. From installation and maintenance to repair and replacement, our skilled technicians have the tools and training to provide outstanding service for various system types, including furnaces, boilers, and Hybrid Heat. Are you stuck without heat due to a breakdown? Trust our emergency heating repair service to restore your system quickly!
Stay warm all winter by scheduling a heating service with Blind & Sons at 330-362-9232!
Air Quality Services in Cuyahoga Falls
Enjoy your time inside with indoor air quality services from Blind & Sons. Our solutions can help improve your comfort & health with services and products, including:
- Air cleaners & purifiers
- Air scrubbers
- Whole-house humidifiers & dehumidifiers
- UV lamp air purification
- Duct cleanings
To schedule indoor air quality services, call 330-362-9232 today!
Dependable Electrical Services
For safe and reliable electrical services, trust the licensed electricians at Blind & Sons. Our comprehensive electrical services include general installation, replacement, repair, electrical panel services, and rewiring. We also offer specialized services, including electrical inspections, whole-home generators, EV chargers, and more!
Call Blind & Sons today at 330-362-9232 to schedule your next electrical service with our team!
Top-Rated Plumbing Services
Keep your plumbing system operating at peak performance with plumbing services from Blind & Sons. Our expert plumbers are here to handle even the most complex repairs to help protect your home from water damage and ensure that you have the reliable plumbing you need.
We also provide comprehensive water heater services for standard and tankless systems to ensure you can access the hot water you need. Plus, with drain cleaning services, we’ll remove stubborn clogs to ensure your pipes can flow freely!
Trust the plumbers at Blind & Sons! Call 330-362-9232 today to schedule service!
Choose Blind & Sons in Cuyahoga Falls
Since 1937, Blind & Sons has provided outstanding HVAC, plumbing, and electrical service to the residents of Cuyahoga Falls and Northeast Ohio. We’re proud to offer emergency heating and cooling services to ensure our customers’ comfort is never compromised. Plus, with our satisfaction guarantee, you can trust you’re only getting the best possible service from our team!
Call 330-362-9232 today to schedule HVAC, plumbing, or electrical services for your Cuyahoga Falls home!
Blind and Sons has completed 20 jobs in Cuyahoga Falls, OH in April 2026. The most recent job was on April 24, 2026. Blind and Sons has completed 1,014 jobs in Cuyahoga Falls, OH in the last 12 months.Recent Jobs and Reviews in Cuyahoga Falls, OH
Cuyahoga Falls, OH at a glance
Job Locations and Reviews
Performed routine maintenance flush on residential tanked water heater to remove sediment buildup and maintain optimal heating efficiency. Drained tank completely, flushed system thoroughly, and refilled unit. Inspected water heater condition, copper supply lines, and connections for any signs of deterioration or leaks; all components found to be in satisfactory working order.
Completed comprehensive AC tune-up inspection on residential HVAC system. Examined evaporator coil assembly, heat exchanger fins, and refrigerant line connections, noting moderate oxidation on copper tubing and accumulated surface debris on internal components. All mechanical components inspected and unit confirmed operational within normal parameters.
Completed scheduled MVP cooling maintenance visit on residential outdoor condensing unit. Performed comprehensive system inspection of the unit positioned on concrete pad, checking refrigerant lines, electrical connections, and overall equipment condition. Unit found operating within normal parameters with no immediate service needs identified.
Completed air conditioning maintenance on two units at separate locations. Performed standard tune-up procedures including inspection of internal components, electrical connections, and control boards. Verified proper operation of blower motor assembly and checked all wiring connections. Inspected 16x25x1 air filter and confirmed acceptable condition with minimal dust accumulation.
Completed standard air conditioning maintenance service on residential HVAC system, including inspection of Carrier WeatherMaker 8000 furnace and cooling components. Customer requested thermostat replacement with a basic non-programmable unit due to current thermostat malfunction. Provided complimentary carbon monoxide detector as part of seasonal maintenance promotion.
Completed routine maintenance visit on 8-year-old Lennox air conditioning system for MVP customer. Performed comprehensive inspection of outdoor condenser unit, verified proper operation of electrical components including capacitor and wiring connections, and documented equipment condition through photographs. Unit found in good working order with no immediate service needs identified.
Completed installation of two new toilets in residential bathrooms. Installed a round-bowl, two-piece toilet in the hall bathroom and an elongated-bowl, two-piece toilet in the master bathroom. Both units feature standard white porcelain construction with chrome flush levers and were properly connected to existing water supply lines with shut-off valves. All installations were tested for proper function and verified leak-free operation.
Completed comprehensive MVP cooling maintenance on Lennox air conditioning system. Performed thorough inspection of outdoor condenser unit and indoor furnace components, verified proper operation of all equipment, checked refrigerant levels, cleaned condenser coils, inspected electrical connections and disconnect box, examined ductwork and PVC condensate drain lines for proper function. All systems operating within normal parameters upon completion of scheduled maintenance visit.
Completed preventive maintenance cooling visit on Trane outdoor condensing unit located behind residence. Upon inspection, discovered significant dust and debris accumulation on evaporator coil fins, which was documented and measured. Performed standard maintenance protocol including system inspection, cleaning procedures, and operational testing to ensure proper cooling efficiency and system performance.
Responded to a toilet issue at a 70-year-old residential property. Upon arrival, inspected the toilet fixture and surrounding plumbing components to diagnose the reported problem. Completed necessary repairs to restore proper toilet function and verified system operation before departure.
Diagnosed refrigerant leak in exterior lineset on residential air conditioning system. Scheduled return visit after weather improvement to perform lineset repair and restore system to proper operation.
Responded to service call for loud noise complaint on two-year-old furnace system. Upon arrival, performed complete visual inspection of furnace unit with access panel removed, examining internal components including blower assembly, inducer motor, heat exchanger, and control board for signs of mechanical failure or loose components. All internal wiring, connections, and mounting hardware were inspected for proper security. Unable to replicate reported noise condition during operational testing. Exterior condenser unit was observed with significant debris accumulation on cooling coils, which may contribute to system strain and unusual operational sounds. Customer contact requested prior to scheduling return visit for further diagnostic evaluation if noise condition persists.
Completed scheduled BS-MVP cooling maintenance visit on a 5-year-old Lennox HVAC system. Arrived at requested 8:00 AM timeframe and performed comprehensive inspection of both indoor furnace unit and outdoor condenser. Indoor unit showed normal operating condition with proper connections and ductwork intact. Outdoor condenser exhibited significant dirt accumulation on exterior panels with vertical streaking and discoloration, along with algae and moss growth on base pad and surrounding area. Documented equipment condition through photographic records for maintenance history.
Completed routine MVP cooling maintenance visit on residential air conditioning system. Performed comprehensive inspection of outdoor condenser unit, verified proper operation of all components, cleared debris from around unit, and confirmed adequate airflow through coils and louvers. System operating within normal parameters with no issues identified.
Conducted on-site estimate for mini split installation in residential property. Assessed basement area with existing HVAC equipment and evaluated exterior foundation wall for outdoor condenser placement and line set routing. Documented installation requirements including concrete floor conditions, available mounting locations, and exterior access points through foundation. Coordinated scheduling for installation appointment with customer requesting availability no earlier than 6:30 PM and Saturday service option.
Responded to service call for water heater repair at residential property. Upon arrival, performed comprehensive inspection of tanked water heater unit located in basement mechanical room. Assessed water heater condition, examined all visible connections including copper supply lines and galvanized steel piping, and evaluated overall system performance. Inspected top-mounted pipe connections, pressure relief valve, and related plumbing infrastructure. Verified proper clearances around unit and checked for any signs of leakage or corrosion on tank surface and pipe connections. Documented existing installation with photographs showing water heater positioned adjacent to HVAC furnace system with connected ductwork. Completed necessary repairs to restore water heater to proper working condition and applied promotional discount as requested.
Responded to water leak originating from bathroom and penetrating through ceiling into kitchen area of 60-year-old residential property. Upon inspection, identified significant ceiling deterioration around plumbing penetration point with extensive water damage, including cracked and peeling textured ceiling material, exposed substrate, and compromised structural elements. Assessed bathroom plumbing fixtures and flooring condition. Documented damage with photographs showing deteriorated ceiling section with black pipe penetration and extent of material failure. Leak source identified and evaluated for repair recommendations given age of home's plumbing system.
Responded to second callback for detached water heater flue pipe. Upon arrival, found the galvanized B-vent chimney pipe separated from the water heater draft hood and pulling away from ceiling penetration. Inspected the complete venting system including the draft inducer assembly, vertical vent pipe sections, and ceiling support. Documented the failed connection points and compromised structural support with photographs showing the mushroom cap rain collar at ceiling level and the disconnected ductwork sections. The venting system requires immediate repair to prevent dangerous exhaust gas spillage into the living space and ensure proper combustion air flow.
Completed water softener salt delivery and restocking. Delivered and placed salt supply in utility room, replenished brine tank with salt pellets to ensure continued operation of water treatment system.
Completed preventive maintenance on Trane XR13 air conditioning system, model 4TTR3024G1000AA. Performed comprehensive inspection of outdoor condensing unit and indoor evaporator coil assembly, verified refrigerant charge of R-410A, checked electrical connections and specifications against manufacturer nameplate data, and documented equipment condition through photographic records. All components found operating within normal parameters.