Schedule Service

HVAC, Plumbing & Electrical in Cuyahoga Falls, OH

When you need the best home services in Cuyahoga Falls, trust the team at Blind & Sons. With over 80 years in business, our team of experts offers comprehensive HVAC, plumbing, and electrical services to ensure your home is functional and comfortable.

Our highly trained technicians are the best in the industry, and we stand behind our work with unmatched warranties and guarantees. That’s why we’re known to meet your needs and exceed your expectations!

Schedule HVAC, plumbing, or electrical services today by calling Blind & Sons at 330-362-9232!

An expert plumber skillfully repairs a leaking pipe using a tool.

Same-Day Cooling Services

Stay comfortable during the muggy season with our superior cooling services. We’re proud to offer installation, replacement, repair, and maintenance on various systems, including central air, heat pumps, and ductless mini-splits. With our extensive experience, we can handle it all, and with our available emergency AC repair, we’re there for you when you need us most!

Need Services?

Reliable Heating Services

Winters in Cuyahoga Falls can be bitterly cold and snowy. Stay warm and comfortable on even the coldest day of the year with our unmatched heating services. From installation and maintenance to repair and replacement, our skilled technicians have the tools and training to provide outstanding service for various system types, including furnaces, boilers, and Hybrid Heat. Are you stuck without heat due to a breakdown? Trust our emergency heating repair service to restore your system quickly!

Stay warm all winter by scheduling a heating service with Blind & Sons at 330-362-9232!

Air Quality Services in Cuyahoga Falls

Enjoy your time inside with indoor air quality services from Blind & Sons. Our solutions can help improve your comfort & health with services and products, including:

To schedule indoor air quality services, call 330-362-9232 today!

Dependable Electrical Services

For safe and reliable electrical services, trust the licensed electricians at Blind & Sons. Our comprehensive electrical services include general installation, replacement, repair, electrical panel services, and rewiring. We also offer specialized services, including electrical inspections, whole-home generators, EV chargers, and more!

Call Blind & Sons today at 330-362-9232 to schedule your next electrical service with our team!

Top-Rated Plumbing Services

Keep your plumbing system operating at peak performance with plumbing services from Blind & Sons. Our expert plumbers are here to handle even the most complex repairs to help protect your home from water damage and ensure that you have the reliable plumbing you need.

We also provide comprehensive water heater services for standard and tankless systems to ensure you can access the hot water you need. Plus, with drain cleaning services, we’ll remove stubborn clogs to ensure your pipes can flow freely!

Trust the plumbers at Blind & Sons! Call 330-362-9232 today to schedule service!

Choose Blind & Sons in Cuyahoga Falls

Since 1937, Blind & Sons has provided outstanding HVAC, plumbing, and electrical service to the residents of Cuyahoga Falls and Northeast Ohio. We’re proud to offer emergency heating and cooling services to ensure our customers’ comfort is never compromised. Plus, with our satisfaction guarantee, you can trust you’re only getting the best possible service from our team!

Call 330-362-9232 today to schedule HVAC, plumbing, or electrical services for your Cuyahoga Falls home!

 

Recent Jobs and Reviews in Cuyahoga Falls, OH

Cuyahoga Falls, OH at a glance

Blind and Sons has completed 20 jobs in Cuyahoga Falls, OH in November 2026.

The most recent job was on November 5, 2026.

Blind and Sons has completed 1,009 jobs in Cuyahoga Falls, OH in the last 12 months.

Job Locations and Reviews

Performed MVP maintenance on two gas furnaces, inspecting the inducer motor and capacitor, gas valve assembly, pressure switch, and wiring harnesses for secure connections, proper routing, and signs of wear. Examined the integrated control boards, relays, and terminal connections, and noted worn electrical tape on the main wiring bundle. Cleaned light dust and grime from cabinet components, and found no evidence of rust, frost, or breakage. Both units were left in good operating condition.
Performed MVP maintenance on two gas furnaces, inspecting the inducer motor and capacitor, gas valve assembly, pressure switch, and wiring harnesses for secure connections, proper routing, and signs of wear. Examined the integrated control boards, relays, and terminal connections, and noted worn electrical tape on the main wiring bundle. Cleaned light dust and grime from cabinet components, and found no evidence of rust, frost, or breakage. Both units were left in good operating condition.
Stephanie E.
Stephanie E. Checked in
Performed MVP maintenance on two gas furnaces, inspecting the inducer motor and capacitor, gas valve assembly, pressure switch, and wiring harnesses for secure connections, proper routing, and signs of wear. Examined the integrated control boards, relays, and terminal connections, and noted worn electrical tape on the main wiring bundle. Cleaned light dust and grime from cabinet components, and found no evidence of rust, frost, or breakage. Both units were left in good operating condition.
Cuyahoga Falls, OH 44221
Performed scheduled heating maintenance on a 13-year-old natural gas furnace, including a combustion analysis that showed O2 at 12.1%, CO at 54 ppm, CO2 at 5.0%, and 97.9% efficiency. The furnace cabinet, PVC vent and intake piping, condensate drain line, and ductwork were inspected with no frost, ice, or significant rust observed, and the unit was left operating normally.
Performed scheduled heating maintenance on a 13-year-old natural gas furnace, including a combustion analysis that showed O2 at 12.1%, CO at 54 ppm, CO2 at 5.0%, and 97.9% efficiency. The furnace cabinet, PVC vent and intake piping, condensate drain line, and ductwork were inspected with no frost, ice, or significant rust observed, and the unit was left operating normally.
Derrick M.
Derrick M. Checked in
Performed scheduled heating maintenance on a 13-year-old natural gas furnace, including a combustion analysis that showed O2 at 12.1%, CO at 54 ppm, CO2 at 5.0%, and 97.9% efficiency. The furnace cabinet, PVC vent and intake piping, condensate drain line, and ductwork were inspected with no frost, ice, or significant rust observed, and the unit was left operating normally.
Cuyahoga Falls, OH 44221
Performed a seasonal tune-up on a Goodman GMSS920603BNAA gas furnace, including inspection of the cabinet interior, burner assembly, and flame sensor, which was cleaned of accumulated residue to ensure reliable flame rectification. Verified safe, proper operation of the unit along with its venting and associated ductwork.
Performed a seasonal tune-up on a Goodman GMSS920603BNAA gas furnace, including inspection of the cabinet interior, burner assembly, and flame sensor, which was cleaned of accumulated residue to ensure reliable flame rectification. Verified safe, proper operation of the unit along with its venting and associated ductwork.
Derrick M.
Derrick M. Checked in
Performed a seasonal tune-up on a Goodman GMSS920603BNAA gas furnace, including inspection of the cabinet interior, burner assembly, and flame sensor, which was cleaned of accumulated residue to ensure reliable flame rectification. Verified safe, proper operation of the unit along with its venting and associated ductwork.
Cuyahoga Falls, OH 44223
Responded to a furnace error code call and inspected the SureLight integrated furnace control board and surrounding low-voltage wiring, terminal connections, and harness plugs. The board and connections showed no visible damage, corrosion, or burn marks, and the system's diagnostic fault code was reviewed to verify operation.
Responded to a furnace error code call and inspected the SureLight integrated furnace control board and surrounding low-voltage wiring, terminal connections, and harness plugs. The board and connections showed no visible damage, corrosion, or burn marks, and the system's diagnostic fault code was reviewed to verify operation.
Jibreel H.
Jibreel H. Checked in
Responded to a furnace error code call and inspected the SureLight integrated furnace control board and surrounding low-voltage wiring, terminal connections, and harness plugs. The board and connections showed no visible damage, corrosion, or burn marks, and the system's diagnostic fault code was reviewed to verify operation.
Cuyahoga Falls, OH 44223
Performed seasonal heating maintenance on a 9-year-old Lennox gas furnace, inspecting the inducer motor, gas valve assembly, and wiring connections and confirming proper condition with no frost, rust, or other visible anomalies. Verified flue piping, condensate/PVC drain components, and gas supply connections were secure, and the unit was left operating normally and ready for the heating season.
Performed seasonal heating maintenance on a 9-year-old Lennox gas furnace, inspecting the inducer motor, gas valve assembly, and wiring connections and confirming proper condition with no frost, rust, or other visible anomalies. Verified flue piping, condensate/PVC drain components, and gas supply connections were secure, and the unit was left operating normally and ready for the heating season.
Jibreel H.
Jibreel H. Checked in
Performed seasonal heating maintenance on a 9-year-old Lennox gas furnace, inspecting the inducer motor, gas valve assembly, and wiring connections and confirming proper condition with no frost, rust, or other visible anomalies. Verified flue piping, condensate/PVC drain components, and gas supply connections were secure, and the unit was left operating normally and ready for the heating season.
Cuyahoga Falls, OH 44223
Performed annual maintenance on a 3-year-old gas furnace, including inspection of the air handler cabinet, filter, condensate pump, and associated ductwork and venting, with no signs of rust, frost, or damage observed. Unit is operating normally. Customer requested a quote for a whole-home humidifier installation.
Performed annual maintenance on a 3-year-old gas furnace, including inspection of the air handler cabinet, filter, condensate pump, and associated ductwork and venting, with no signs of rust, frost, or damage observed. Unit is operating normally. Customer requested a quote for a whole-home humidifier installation.
John W.
John W. Checked in
Performed annual maintenance on a 3-year-old gas furnace, including inspection of the air handler cabinet, filter, condensate pump, and associated ductwork and venting, with no signs of rust, frost, or damage observed. Unit is operating normally. Customer requested a quote for a whole-home humidifier installation.
Cuyahoga Falls, OH 44221
Performed seasonal heating maintenance on a 10-year-old natural gas furnace, including a combustion analysis that recorded O2 at 5.3%, CO at 65 ppm, CO2 at 8.8%, and steady-state efficiency of 93.2%. Cleared accumulated leaves and debris from the top of the equipment cabinet around the condensate drain and PVC fitting to maintain proper drainage and unobstructed airflow.
Performed seasonal heating maintenance on a 10-year-old natural gas furnace, including a combustion analysis that recorded O2 at 5.3%, CO at 65 ppm, CO2 at 8.8%, and steady-state efficiency of 93.2%. Cleared accumulated leaves and debris from the top of the equipment cabinet around the condensate drain and PVC fitting to maintain proper drainage and unobstructed airflow.
Stephanie E.
Stephanie E. Checked in
Performed seasonal heating maintenance on a 10-year-old natural gas furnace, including a combustion analysis that recorded O2 at 5.3%, CO at 65 ppm, CO2 at 8.8%, and steady-state efficiency of 93.2%. Cleared accumulated leaves and debris from the top of the equipment cabinet around the condensate drain and PVC fitting to maintain proper drainage and unobstructed airflow.
Cuyahoga Falls, OH 44223
Performed a system inspection and verified the furnace was operating within factory tolerances. Identified a corroded galvanized flue pipe and recommended replacement, and the required parts have been ordered and received for the repair.
Performed a system inspection and verified the furnace was operating within factory tolerances. Identified a corroded galvanized flue pipe and recommended replacement, and the required parts have been ordered and received for the repair.
John W.
John W. Checked in
Performed a system inspection and verified the furnace was operating within factory tolerances. Identified a corroded galvanized flue pipe and recommended replacement, and the required parts have been ordered and received for the repair.
Cuyahoga Falls, OH 44223
Performed annual MVP maintenance on the gas furnace, including removal of the front access panel to inspect the blower motor, gas valve assembly, control board, and wiring harness connections. Verified the condensate/PVC venting, gas supply piping, and line-voltage conduit connections were secure and free of visible corrosion or damage, and inspected the AprilAire air cleaner cabinet and filter. The system was reassembled and left in proper working order, with a faint damp patch on the floor in front of the furnace noted for monitoring.
Performed annual MVP maintenance on the gas furnace, including removal of the front access panel to inspect the blower motor, gas valve assembly, control board, and wiring harness connections. Verified the condensate/PVC venting, gas supply piping, and line-voltage conduit connections were secure and free of visible corrosion or damage, and inspected the AprilAire air cleaner cabinet and filter. The system was reassembled and left in proper working order, with a faint damp patch on the floor in front of the furnace noted for monitoring.
Frank W.
Frank W. Checked in
Performed annual MVP maintenance on the gas furnace, including removal of the front access panel to inspect the blower motor, gas valve assembly, control board, and wiring harness connections. Verified the condensate/PVC venting, gas supply piping, and line-voltage conduit connections were secure and free of visible corrosion or damage, and inspected the AprilAire air cleaner cabinet and filter. The system was reassembled and left in proper working order, with a faint damp patch on the floor in front of the furnace noted for monitoring.
Cuyahoga Falls, OH 44223
Installed a Moen Flo smart water monitor in-line on the vertical copper main supply downstream of the secondary shut-off, powered from the adjacent outlet, and completed system setup and operation walkthrough with the homeowner. Replaced the three kitchen sink supply shut-off valves with new quarter-turn valves and installed a thermal expansion tank on the water heater to bring the system up to code.
Installed a Moen Flo smart water monitor in-line on the vertical copper main supply downstream of the secondary shut-off, powered from the adjacent outlet, and completed system setup and operation walkthrough with the homeowner. Replaced the three kitchen sink supply shut-off valves with new quarter-turn valves and installed a thermal expansion tank on the water heater to bring the system up to code.
Jared K.
Jared K. Checked in
Installed a Moen Flo smart water monitor in-line on the vertical copper main supply downstream of the secondary shut-off, powered from the adjacent outlet, and completed system setup and operation walkthrough with the homeowner. Replaced the three kitchen sink supply shut-off valves with new quarter-turn valves and installed a thermal expansion tank on the water heater to bring the system up to code.
Cuyahoga Falls, OH 44221
Performed scheduled heating maintenance on a natural gas furnace, including inspection of the blower assembly, wiring, and control components, and verified the return air filter (20x25x1) condition. Conducted a combustion analysis with a Bacharach digital analyzer, recording CO at 34 ppm, CO₂ at 6.8%, stack temperature of 344°F, and steady-state efficiency of 80.9%, confirming safe and normal operation. No frost, rust, or visible damage was found, and the system was left operating properly.
Performed scheduled heating maintenance on a natural gas furnace, including inspection of the blower assembly, wiring, and control components, and verified the return air filter (20x25x1) condition. Conducted a combustion analysis with a Bacharach digital analyzer, recording CO at 34 ppm, CO₂ at 6.8%, stack temperature of 344°F, and steady-state efficiency of 80.9%, confirming safe and normal operation. No frost, rust, or visible damage was found, and the system was left operating properly.
Frank W.
Frank W. Checked in
Performed scheduled heating maintenance on a natural gas furnace, including inspection of the blower assembly, wiring, and control components, and verified the return air filter (20x25x1) condition. Conducted a combustion analysis with a Bacharach digital analyzer, recording CO at 34 ppm, CO₂ at 6.8%, stack temperature of 344°F, and steady-state efficiency of 80.9%, confirming safe and normal operation. No frost, rust, or visible damage was found, and the system was left operating properly.
Cuyahoga Falls, OH 44223
Cuyahoga Falls, OH - Performed descaling maintenance on the tankless water heater by isolating the unit and connecting a flexible service hose circuit to a recirculation bucket charged with descaler solution. Circulated the solution through the heat exchanger to dissolve mineral scale buildup, then flushed the system to restore proper flow and heat transfer efficiency.
Nick L.
Nick L. Checked in
Performed descaling maintenance on the tankless water heater by isolating the unit and connecting a flexible service hose circuit to a recirculation bucket charged with descaler solution. Circulated the solution through the heat exchanger to dissolve mineral scale buildup, then flushed the system to restore proper flow and heat transfer efficiency.
Cuyahoga Falls, OH 44223
Trenched and installed conduit to extend power to the detached garage, routing from the basement junction box along the exterior of the rear addition and underground through an approximately 15 ft trench. Fed the existing garage circuit and installed two new outlets above the garage doors to power the new openers.
Trenched and installed conduit to extend power to the detached garage, routing from the basement junction box along the exterior of the rear addition and underground through an approximately 15 ft trench. Fed the existing garage circuit and installed two new outlets above the garage doors to power the new openers.
Austin B.
Austin B. Checked in
Trenched and installed conduit to extend power to the detached garage, routing from the basement junction box along the exterior of the rear addition and underground through an approximately 15 ft trench. Fed the existing garage circuit and installed two new outlets above the garage doors to power the new openers.
Cuyahoga Falls, OH 44221
Upgraded the electrical service to 200A with a new panel, installed an exterior disconnect, and made the code updates required under the 2023 National Electrical Code. Ran new 2" PVC conduit with proper strapping and conduit body terminations for the service conductors, and installed whole-home surge protection to safeguard the home's electrical system.
Upgraded the electrical service to 200A with a new panel, installed an exterior disconnect, and made the code updates required under the 2023 National Electrical Code. Ran new 2" PVC conduit with proper strapping and conduit body terminations for the service conductors, and installed whole-home surge protection to safeguard the home's electrical system.
Matthew H.
Matthew H. Checked in
Upgraded the electrical service to 200A with a new panel, installed an exterior disconnect, and made the code updates required under the 2023 National Electrical Code. Ran new 2" PVC conduit with proper strapping and conduit body terminations for the service conductors, and installed whole-home surge protection to safeguard the home's electrical system.
Cuyahoga Falls, OH 44223
Performed annual heating maintenance on a 7-year-old gas furnace, including inspection of the gas valve assembly, pressure switch, inducer motor, flame sensor, and low-voltage wiring, and verified manifold gas pressure and static pressure readings with a digital dual-port manometer. Noted heavy corrosion and oxidation on the copper line near the flame sensor/igniter area and recommended monitoring it for potential future repair. Unit was left operating properly with no visible damage, frost, or ice evident.
Performed annual heating maintenance on a 7-year-old gas furnace, including inspection of the gas valve assembly, pressure switch, inducer motor, flame sensor, and low-voltage wiring, and verified manifold gas pressure and static pressure readings with a digital dual-port manometer. Noted heavy corrosion and oxidation on the copper line near the flame sensor/igniter area and recommended monitoring it for potential future repair. Unit was left operating properly with no visible damage, frost, or ice evident.
Matthew F.
Matthew F. Checked in
Performed annual heating maintenance on a 7-year-old gas furnace, including inspection of the gas valve assembly, pressure switch, inducer motor, flame sensor, and low-voltage wiring, and verified manifold gas pressure and static pressure readings with a digital dual-port manometer. Noted heavy corrosion and oxidation on the copper line near the flame sensor/igniter area and recommended monitoring it for potential future repair. Unit was left operating properly with no visible damage, frost, or ice evident.
Cuyahoga Falls, OH 44223
Responded to a water leak complaint on a 19-year-old furnace and central AC system. Inspected the unit with a borescope and found heavy corrosion and rust on the cabinet top surface surrounding the inducer motor and gas piping, consistent with prolonged condensate leakage from the evaporator coil/drain assembly. Documented the affected areas and cabinet condition, and the system remains operational pending recommended condensate drain and cabinet repair.
Responded to a water leak complaint on a 19-year-old furnace and central AC system. Inspected the unit with a borescope and found heavy corrosion and rust on the cabinet top surface surrounding the inducer motor and gas piping, consistent with prolonged condensate leakage from the evaporator coil/drain assembly. Documented the affected areas and cabinet condition, and the system remains operational pending recommended condensate drain and cabinet repair.
Daniel S.
Daniel S. Checked in
Responded to a water leak complaint on a 19-year-old furnace and central AC system. Inspected the unit with a borescope and found heavy corrosion and rust on the cabinet top surface surrounding the inducer motor and gas piping, consistent with prolonged condensate leakage from the evaporator coil/drain assembly. Documented the affected areas and cabinet condition, and the system remains operational pending recommended condensate drain and cabinet repair.
Cuyahoga Falls, OH 44223
Performed annual maintenance on a natural gas furnace, including inspection of the burner assembly, draft inducer, pressure switch, gas valve, and control board wiring. Completed a combustion analysis, which recorded CO at 28 ppm, CO2 at 8.5%, stack temperature of 101°F, and combustion efficiency of 96.7%, confirming safe and efficient operation. No corrosion, frost, or component damage was observed.
Performed annual maintenance on a natural gas furnace, including inspection of the burner assembly, draft inducer, pressure switch, gas valve, and control board wiring. Completed a combustion analysis, which recorded CO at 28 ppm, CO2 at 8.5%, stack temperature of 101°F, and combustion efficiency of 96.7%, confirming safe and efficient operation. No corrosion, frost, or component damage was observed.
Frank W.
Frank W. Checked in
Performed annual maintenance on a natural gas furnace, including inspection of the burner assembly, draft inducer, pressure switch, gas valve, and control board wiring. Completed a combustion analysis, which recorded CO at 28 ppm, CO2 at 8.5%, stack temperature of 101°F, and combustion efficiency of 96.7%, confirming safe and efficient operation. No corrosion, frost, or component damage was observed.
Cuyahoga Falls, OH 44223
Installed a Navien NPE-240A2 tankless water heater with the Navien recirculation kit, connecting the water supply and gas lines and routing the condensate drain to the nearby floor drain. Ran the venting through the rear exterior wall with a sealed PVC termination, relocating the existing shelf to clear the vent path, and supplied power from the adjacent electrical outlet.
Installed a Navien NPE-240A2 tankless water heater with the Navien recirculation kit, connecting the water supply and gas lines and routing the condensate drain to the nearby floor drain. Ran the venting through the rear exterior wall with a sealed PVC termination, relocating the existing shelf to clear the vent path, and supplied power from the adjacent electrical outlet.
Deontae G.
Deontae G. Checked in
Installed a Navien NPE-240A2 tankless water heater with the Navien recirculation kit, connecting the water supply and gas lines and routing the condensate drain to the nearby floor drain. Ran the venting through the rear exterior wall with a sealed PVC termination, relocating the existing shelf to clear the vent path, and supplied power from the adjacent electrical outlet.
Cuyahoga Falls, OH 44223
Performed a scheduled heating maintenance on a 2-year-old gas furnace, including inspection of the humidifier evaporator pad, which showed heavy mineral scale and debris buildup and was documented for cleaning or replacement. Verified gas manifold pressure and system pressures using a digital dual-port manometer, and inspected the gas valve, inducer/blower assembly, wiring, and condensate and drain components, finding no visible rust, frost, or damage.
Performed a scheduled heating maintenance on a 2-year-old gas furnace, including inspection of the humidifier evaporator pad, which showed heavy mineral scale and debris buildup and was documented for cleaning or replacement. Verified gas manifold pressure and system pressures using a digital dual-port manometer, and inspected the gas valve, inducer/blower assembly, wiring, and condensate and drain components, finding no visible rust, frost, or damage.
Matthew F.
Matthew F. Checked in
Performed a scheduled heating maintenance on a 2-year-old gas furnace, including inspection of the humidifier evaporator pad, which showed heavy mineral scale and debris buildup and was documented for cleaning or replacement. Verified gas manifold pressure and system pressures using a digital dual-port manometer, and inspected the gas valve, inducer/blower assembly, wiring, and condensate and drain components, finding no visible rust, frost, or damage.
Cuyahoga Falls, OH 44221
Performed a heating tune-up on a 12-year-old furnace, including inspection of the flame sensor/igniter assembly, gas valve, wiring connections, and control board. Verified gas manifold pressure using a digital dual-port manometer (readings stable at approximately 4.8 in. w.c.) and confirmed proper condensate drain piping. No evidence of frost, rust, or component breakage was found, and the system was left operating within normal parameters.
Performed a heating tune-up on a 12-year-old furnace, including inspection of the flame sensor/igniter assembly, gas valve, wiring connections, and control board. Verified gas manifold pressure using a digital dual-port manometer (readings stable at approximately 4.8 in. w.c.) and confirmed proper condensate drain piping. No evidence of frost, rust, or component breakage was found, and the system was left operating within normal parameters.
Matthew F.
Matthew F. Checked in
Performed a heating tune-up on a 12-year-old furnace, including inspection of the flame sensor/igniter assembly, gas valve, wiring connections, and control board. Verified gas manifold pressure using a digital dual-port manometer (readings stable at approximately 4.8 in. w.c.) and confirmed proper condensate drain piping. No evidence of frost, rust, or component breakage was found, and the system was left operating within normal parameters.
Cuyahoga Falls, OH 44223

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image