Schedule Service

HVAC, Plumbing & Electrical in Cuyahoga Falls, OH

When you need the best home services in Cuyahoga Falls, trust the team at Blind & Sons. With over 80 years in business, our team of experts offers comprehensive HVAC, plumbing, and electrical services to ensure your home is functional and comfortable.

Our highly trained technicians are the best in the industry, and we stand behind our work with unmatched warranties and guarantees. That’s why we’re known to meet your needs and exceed your expectations!

Schedule HVAC, plumbing, or electrical services today by calling Blind & Sons at 330-362-9232!

An expert plumber skillfully repairs a leaking pipe using a tool.

Same-Day Cooling Services

Stay comfortable during the muggy season with our superior cooling services. We’re proud to offer installation, replacement, repair, and maintenance on various systems, including central air, heat pumps, and ductless mini-splits. With our extensive experience, we can handle it all, and with our available emergency AC repair, we’re there for you when you need us most!

Need Services?

Reliable Heating Services

Winters in Cuyahoga Falls can be bitterly cold and snowy. Stay warm and comfortable on even the coldest day of the year with our unmatched heating services. From installation and maintenance to repair and replacement, our skilled technicians have the tools and training to provide outstanding service for various system types, including furnaces, boilers, and Hybrid Heat. Are you stuck without heat due to a breakdown? Trust our emergency heating repair service to restore your system quickly!

Stay warm all winter by scheduling a heating service with Blind & Sons at 330-362-9232!

Air Quality Services in Cuyahoga Falls

Enjoy your time inside with indoor air quality services from Blind & Sons. Our solutions can help improve your comfort & health with services and products, including:

To schedule indoor air quality services, call 330-362-9232 today!

Dependable Electrical Services

For safe and reliable electrical services, trust the licensed electricians at Blind & Sons. Our comprehensive electrical services include general installation, replacement, repair, electrical panel services, and rewiring. We also offer specialized services, including electrical inspections, whole-home generators, EV chargers, and more!

Call Blind & Sons today at 330-362-9232 to schedule your next electrical service with our team!

Top-Rated Plumbing Services

Keep your plumbing system operating at peak performance with plumbing services from Blind & Sons. Our expert plumbers are here to handle even the most complex repairs to help protect your home from water damage and ensure that you have the reliable plumbing you need.

We also provide comprehensive water heater services for standard and tankless systems to ensure you can access the hot water you need. Plus, with drain cleaning services, we’ll remove stubborn clogs to ensure your pipes can flow freely!

Trust the plumbers at Blind & Sons! Call 330-362-9232 today to schedule service!

Choose Blind & Sons in Cuyahoga Falls

Since 1937, Blind & Sons has provided outstanding HVAC, plumbing, and electrical service to the residents of Cuyahoga Falls and Northeast Ohio. We’re proud to offer emergency heating and cooling services to ensure our customers’ comfort is never compromised. Plus, with our satisfaction guarantee, you can trust you’re only getting the best possible service from our team!

Call 330-362-9232 today to schedule HVAC, plumbing, or electrical services for your Cuyahoga Falls home!

 

Recent Jobs and Reviews in Cuyahoga Falls, OH

Cuyahoga Falls, OH at a glance

Blind and Sons has completed 20 jobs in Cuyahoga Falls, OH between October 2026 and November 2026.

The most recent job was on November 3, 2026.

Blind and Sons has completed 1,009 jobs in Cuyahoga Falls, OH in the last 12 months.

Job Locations and Reviews

Cuyahoga Falls, OH - Performed annual heating tune-up on the gas furnace, including inspection of the gas valve assembly, inducer motor, wiring harness, control board, and PVC vent/intake piping. Noted scorch marks, discoloration, and heavy dust and debris buildup on the burner compartment floor, indicating prior flame rollout or overheating; recommend further evaluation of the heat exchanger, burners, and venting to ensure safe operation.
John W.
John W. Checked in
Performed annual heating tune-up on the gas furnace, including inspection of the gas valve assembly, inducer motor, wiring harness, control board, and PVC vent/intake piping. Noted scorch marks, discoloration, and heavy dust and debris buildup on the burner compartment floor, indicating prior flame rollout or overheating; recommend further evaluation of the heat exchanger, burners, and venting to ensure safe operation.
Cuyahoga Falls, OH 44223
Performed seasonal heating maintenance on a 7-year-old gas furnace, including inspection of the cabinet interior and wiring harness connections with electrical measurements taken using a clamp-style multimeter. Inspected the air filter, which showed only light dust accumulation and was in serviceable condition, and observed no signs of frost, rust, or visible damage on the equipment.
Performed seasonal heating maintenance on a 7-year-old gas furnace, including inspection of the cabinet interior and wiring harness connections with electrical measurements taken using a clamp-style multimeter. Inspected the air filter, which showed only light dust accumulation and was in serviceable condition, and observed no signs of frost, rust, or visible damage on the equipment.
Matthew F.
Matthew F. Checked in
Performed seasonal heating maintenance on a 7-year-old gas furnace, including inspection of the cabinet interior and wiring harness connections with electrical measurements taken using a clamp-style multimeter. Inspected the air filter, which showed only light dust accumulation and was in serviceable condition, and observed no signs of frost, rust, or visible damage on the equipment.
Cuyahoga Falls, OH 44223
Performed recurring heating maintenance, including a combustion analysis on the natural gas appliance with a Bacharach analyzer. Readings recorded were O₂ 8.3%, CO 32 ppm, CO₂ 7.1%, and efficiency 82.3%, with CO within acceptable limits. Inspected the flue/vent system with a borescope camera and found surface corrosion, residue, and a rust-colored streak with a hairline crack at a seam, which should be monitored and repaired as needed.
Performed recurring heating maintenance, including a combustion analysis on the natural gas appliance with a Bacharach analyzer. Readings recorded were O₂ 8.3%, CO 32 ppm, CO₂ 7.1%, and efficiency 82.3%, with CO within acceptable limits. Inspected the flue/vent system with a borescope camera and found surface corrosion, residue, and a rust-colored streak with a hairline crack at a seam, which should be monitored and repaired as needed.
Daniel
Daniel Checked in
Performed recurring heating maintenance, including a combustion analysis on the natural gas appliance with a Bacharach analyzer. Readings recorded were O₂ 8.3%, CO 32 ppm, CO₂ 7.1%, and efficiency 82.3%, with CO within acceptable limits. Inspected the flue/vent system with a borescope camera and found surface corrosion, residue, and a rust-colored streak with a hairline crack at a seam, which should be monitored and repaired as needed.
Cuyahoga Falls, OH 44223
Performed scheduled heating maintenance, including inspection and cleaning of the squirrel-cage blower wheel to remove accumulated dust and debris buildup from the blades and housing, restoring proper airflow. Inspected the flame sensor and ignition components, finding no visible damage, and verified wiring connections and overall system operation within the equipment cabinet.
Performed scheduled heating maintenance, including inspection and cleaning of the squirrel-cage blower wheel to remove accumulated dust and debris buildup from the blades and housing, restoring proper airflow. Inspected the flame sensor and ignition components, finding no visible damage, and verified wiring connections and overall system operation within the equipment cabinet.
Daniel
Daniel Checked in
Performed scheduled heating maintenance, including inspection and cleaning of the squirrel-cage blower wheel to remove accumulated dust and debris buildup from the blades and housing, restoring proper airflow. Inspected the flame sensor and ignition components, finding no visible damage, and verified wiring connections and overall system operation within the equipment cabinet.
Cuyahoga Falls, OH 44223
Performed annual maintenance on a 12-year-old gas furnace, including a combustion analysis with a Bacharach analyzer that recorded a stack temperature of 85°F, 30.0% excess air, and 79 ppm CO. Inspected the control compartment and tested electrical components with a True RMS clamp meter, finding wiring, connectors, and the control board in good condition with no signs of damage, rust, or frost. The unit is operating normally.
Performed annual maintenance on a 12-year-old gas furnace, including a combustion analysis with a Bacharach analyzer that recorded a stack temperature of 85°F, 30.0% excess air, and 79 ppm CO. Inspected the control compartment and tested electrical components with a True RMS clamp meter, finding wiring, connectors, and the control board in good condition with no signs of damage, rust, or frost. The unit is operating normally.
Daniel
Daniel Checked in
Performed annual maintenance on a 12-year-old gas furnace, including a combustion analysis with a Bacharach analyzer that recorded a stack temperature of 85°F, 30.0% excess air, and 79 ppm CO. Inspected the control compartment and tested electrical components with a True RMS clamp meter, finding wiring, connectors, and the control board in good condition with no signs of damage, rust, or frost. The unit is operating normally.
Cuyahoga Falls, OH 44221
Diagnosed a tanked gas water heater whose pilot would not remain lit after releasing the control knob, indicating a failed thermocouple or flame-sensing safety circuit that closed the gas valve. Inspected the gas supply piping, venting, and surrounding components, then repaired the pilot assembly so the flame stays lit and the gas valve remains open. Relit the unit, verified stable pilot and main burner operation, and confirmed proper heating and venting before completion.
Diagnosed a tanked gas water heater whose pilot would not remain lit after releasing the control knob, indicating a failed thermocouple or flame-sensing safety circuit that closed the gas valve. Inspected the gas supply piping, venting, and surrounding components, then repaired the pilot assembly so the flame stays lit and the gas valve remains open. Relit the unit, verified stable pilot and main burner operation, and confirmed proper heating and venting before completion.
Karl M.
Karl M. Checked in
Diagnosed a tanked gas water heater whose pilot would not remain lit after releasing the control knob, indicating a failed thermocouple or flame-sensing safety circuit that closed the gas valve. Inspected the gas supply piping, venting, and surrounding components, then repaired the pilot assembly so the flame stays lit and the gas valve remains open. Relit the unit, verified stable pilot and main burner operation, and confirmed proper heating and venting before completion.
Cuyahoga Falls, OH 44223
Removed the deteriorated section of galvanized supply piping running from the water heater to the kitchen sink and replaced it with new copper piping, using soldered fittings and perforated strap hangers to secure the run to the floor joists. Verified all connections were tight and leak-free, restoring reliable water flow to the kitchen fixture.
Removed the deteriorated section of galvanized supply piping running from the water heater to the kitchen sink and replaced it with new copper piping, using soldered fittings and perforated strap hangers to secure the run to the floor joists. Verified all connections were tight and leak-free, restoring reliable water flow to the kitchen fixture.
Denny J.
Denny J. Checked in
Removed the deteriorated section of galvanized supply piping running from the water heater to the kitchen sink and replaced it with new copper piping, using soldered fittings and perforated strap hangers to secure the run to the floor joists. Verified all connections were tight and leak-free, restoring reliable water flow to the kitchen fixture.
Cuyahoga Falls, OH 44221
Installed a new gas line branch from the existing hard line trunk to serve a ventless gas stove fireplace in the three-season porch. Routed black iron pipe through the open joist space from the meter area across the structure, then secured and sealed all connections. Completed the installation to code, with the new line ready for appliance connection.
Installed a new gas line branch from the existing hard line trunk to serve a ventless gas stove fireplace in the three-season porch. Routed black iron pipe through the open joist space from the meter area across the structure, then secured and sealed all connections. Completed the installation to code, with the new line ready for appliance connection.
Nick L.
Nick L. Checked in
Installed a new gas line branch from the existing hard line trunk to serve a ventless gas stove fireplace in the three-season porch. Routed black iron pipe through the open joist space from the meter area across the structure, then secured and sealed all connections. Completed the installation to code, with the new line ready for appliance connection.
Cuyahoga Falls, OH 44223
Inspected the 40-gallon atmospheric-vent gas water heater (Bradford White, Model RG240S6N, manufactured April 2021) and verified the gas control valve, gas piping, vent connection, and supply and discharge plumbing with the thermal expansion tank. Confirmed the unit's warranty status through the manufacturer's registration database, which shows the tank and parts coverage active through July 2027 and the unit not yet registered.
Inspected the 40-gallon atmospheric-vent gas water heater (Bradford White, Model RG240S6N, manufactured April 2021) and verified the gas control valve, gas piping, vent connection, and supply and discharge plumbing with the thermal expansion tank. Confirmed the unit's warranty status through the manufacturer's registration database, which shows the tank and parts coverage active through July 2027 and the unit not yet registered.
Nick L.
Nick L. Checked in
Inspected the 40-gallon atmospheric-vent gas water heater (Bradford White, Model RG240S6N, manufactured April 2021) and verified the gas control valve, gas piping, vent connection, and supply and discharge plumbing with the thermal expansion tank. Confirmed the unit's warranty status through the manufacturer's registration database, which shows the tank and parts coverage active through July 2027 and the unit not yet registered.
Cuyahoga Falls, OH 44223
Performed a general electrical safety inspection of the main service panel with the cover removed, visually examining the main breaker, branch circuit breakers, neutral/ground bus bars, and conductor terminations. No evidence of scorching, corrosion, overheating, or physical damage was observed. Evaluated the panel for installation of a whole-home surge protective device and prepared a quote for the customer's review.
Performed a general electrical safety inspection of the main service panel with the cover removed, visually examining the main breaker, branch circuit breakers, neutral/ground bus bars, and conductor terminations. No evidence of scorching, corrosion, overheating, or physical damage was observed. Evaluated the panel for installation of a whole-home surge protective device and prepared a quote for the customer's review.
Austin B.
Austin B. Checked in
Performed a general electrical safety inspection of the main service panel with the cover removed, visually examining the main breaker, branch circuit breakers, neutral/ground bus bars, and conductor terminations. No evidence of scorching, corrosion, overheating, or physical damage was observed. Evaluated the panel for installation of a whole-home surge protective device and prepared a quote for the customer's review.
Cuyahoga Falls, OH 44221
Performed a furnace tune-up, including inspection of the flame sensor, which showed oxidation on the rod tip, and cleaning it to restore reliable flame proving. Inspected the blower compartment, checking the blower housing, control board wiring, and compartment floor for debris, and evaluated the humidifier for proper operation.
Performed a furnace tune-up, including inspection of the flame sensor, which showed oxidation on the rod tip, and cleaning it to restore reliable flame proving. Inspected the blower compartment, checking the blower housing, control board wiring, and compartment floor for debris, and evaluated the humidifier for proper operation.
Taylor F.
Taylor F. Checked in
Performed a furnace tune-up, including inspection of the flame sensor, which showed oxidation on the rod tip, and cleaning it to restore reliable flame proving. Inspected the blower compartment, checking the blower housing, control board wiring, and compartment floor for debris, and evaluated the humidifier for proper operation.
Cuyahoga Falls, OH 44221
Performed annual furnace maintenance, including inspection of the heating system and removal of the heavily soiled pleated air filter, which was coated with dust and debris and restricting airflow. Inspected the hot surface igniter and found it intact, with no cracks, rust, or notable damage. Furnace is operating normally and the filter should be replaced regularly to maintain airflow and system efficiency.
Performed annual furnace maintenance, including inspection of the heating system and removal of the heavily soiled pleated air filter, which was coated with dust and debris and restricting airflow. Inspected the hot surface igniter and found it intact, with no cracks, rust, or notable damage. Furnace is operating normally and the filter should be replaced regularly to maintain airflow and system efficiency.
Stephanie E.
Stephanie E. Checked in
Performed annual furnace maintenance, including inspection of the heating system and removal of the heavily soiled pleated air filter, which was coated with dust and debris and restricting airflow. Inspected the hot surface igniter and found it intact, with no cracks, rust, or notable damage. Furnace is operating normally and the filter should be replaced regularly to maintain airflow and system efficiency.
Cuyahoga Falls, OH 44221
Inspected the undermount bathroom sink and vanity cabinet interior to assess the reported cracked basin, examining the drain tailpiece, slip-joint P-trap assembly, braided stainless supply line, and chrome angle stop valve, with no visible leaks, corrosion, or damage to the supply and drain components. Documented the existing installation with photographs to support a replacement quote for the sink basin.
Inspected the undermount bathroom sink and vanity cabinet interior to assess the reported cracked basin, examining the drain tailpiece, slip-joint P-trap assembly, braided stainless supply line, and chrome angle stop valve, with no visible leaks, corrosion, or damage to the supply and drain components. Documented the existing installation with photographs to support a replacement quote for the sink basin.
Nick L.
Nick L. Checked in
Inspected the undermount bathroom sink and vanity cabinet interior to assess the reported cracked basin, examining the drain tailpiece, slip-joint P-trap assembly, braided stainless supply line, and chrome angle stop valve, with no visible leaks, corrosion, or damage to the supply and drain components. Documented the existing installation with photographs to support a replacement quote for the sink basin.
Cuyahoga Falls, OH 44221
Replaced the failed gas valve on the furnace and verified proper operation after installation. Confirmed manifold gas pressure with a digital manometer, reading approximately 3.5" W.C., and checked that the burner assembly and wiring connections were secure. Noted corrosion on the adjacent black iron gas piping, which should be monitored.
Replaced the failed gas valve on the furnace and verified proper operation after installation. Confirmed manifold gas pressure with a digital manometer, reading approximately 3.5" W.C., and checked that the burner assembly and wiring connections were secure. Noted corrosion on the adjacent black iron gas piping, which should be monitored.
Matthew F.
Matthew F. Checked in
Replaced the failed gas valve on the furnace and verified proper operation after installation. Confirmed manifold gas pressure with a digital manometer, reading approximately 3.5" W.C., and checked that the burner assembly and wiring connections were secure. Noted corrosion on the adjacent black iron gas piping, which should be monitored.
Cuyahoga Falls, OH 44223
Diagnosed a tripping GFCI outlet that was disabling the garage door opener circuit, inspecting the exterior weatherproof outlet box and its conduit run for moisture intrusion, damage, or faults. Documented the condition of the outdoor box and surrounding service area, and evaluated the front of the home for the requested additional outlet to prepare a quote for installation.
Diagnosed a tripping GFCI outlet that was disabling the garage door opener circuit, inspecting the exterior weatherproof outlet box and its conduit run for moisture intrusion, damage, or faults. Documented the condition of the outdoor box and surrounding service area, and evaluated the front of the home for the requested additional outlet to prepare a quote for installation.
Landon M.
Landon M. Checked in
Diagnosed a tripping GFCI outlet that was disabling the garage door opener circuit, inspecting the exterior weatherproof outlet box and its conduit run for moisture intrusion, damage, or faults. Documented the condition of the outdoor box and surrounding service area, and evaluated the front of the home for the requested additional outlet to prepare a quote for installation.
Cuyahoga Falls, OH 44221
Performed annual heating maintenance on the furnace, including inspection of internal components, wiring, and pressure switch connections. Removed, inspected, and cleaned the flame sensor to ensure reliable flame detection and proper burner operation. No signs of rust, cracks, or frost were observed, and the unit is operating normally.
Performed annual heating maintenance on the furnace, including inspection of internal components, wiring, and pressure switch connections. Removed, inspected, and cleaned the flame sensor to ensure reliable flame detection and proper burner operation. No signs of rust, cracks, or frost were observed, and the unit is operating normally.
Taylor F.
Taylor F. Checked in
Performed annual heating maintenance on the furnace, including inspection of internal components, wiring, and pressure switch connections. Removed, inspected, and cleaned the flame sensor to ensure reliable flame detection and proper burner operation. No signs of rust, cracks, or frost were observed, and the unit is operating normally.
Cuyahoga Falls, OH 44221
Performed an on-site evaluation for a standby generator installation, inspecting the exterior utility meter enclosure and the main electrical service panel. Verified the panel is equipped with a 150-amp main breaker and documented existing circuit labeling and panel condition, including minor surface rust, to determine generator sizing, transfer switch placement, and connection requirements. Documented the site with photos for estimate preparation.
Performed an on-site evaluation for a standby generator installation, inspecting the exterior utility meter enclosure and the main electrical service panel. Verified the panel is equipped with a 150-amp main breaker and documented existing circuit labeling and panel condition, including minor surface rust, to determine generator sizing, transfer switch placement, and connection requirements. Documented the site with photos for estimate preparation.
Kevin T.
Kevin T. Checked in
Performed an on-site evaluation for a standby generator installation, inspecting the exterior utility meter enclosure and the main electrical service panel. Verified the panel is equipped with a 150-amp main breaker and documented existing circuit labeling and panel condition, including minor surface rust, to determine generator sizing, transfer switch placement, and connection requirements. Documented the site with photos for estimate preparation.
Cuyahoga Falls, OH 44223
Performed a comprehensive inspection of an 11-year-old Trane furnace, including a borescope examination of the heat exchanger that revealed cracking along the seam with associated rust deposits and corrosion. Evaluated the 11-year-old Research Products humidifier and thermostat operation per the customer's reported concerns. Documented heat exchanger findings with photos for repair or replacement evaluation.
Performed a comprehensive inspection of an 11-year-old Trane furnace, including a borescope examination of the heat exchanger that revealed cracking along the seam with associated rust deposits and corrosion. Evaluated the 11-year-old Research Products humidifier and thermostat operation per the customer's reported concerns. Documented heat exchanger findings with photos for repair or replacement evaluation.
Daniel S.
Daniel S. Checked in
Performed a comprehensive inspection of an 11-year-old Trane furnace, including a borescope examination of the heat exchanger that revealed cracking along the seam with associated rust deposits and corrosion. Evaluated the 11-year-old Research Products humidifier and thermostat operation per the customer's reported concerns. Documented heat exchanger findings with photos for repair or replacement evaluation.
Cuyahoga Falls, OH 44221
Performed MVP furnace maintenance, including a combustion analysis on the natural gas-fired unit using an electronic analyzer. Readings in the flue gas stream showed O2 at 8.6%, CO2 at 6.9%, CO at 43 ppm, and steady-state efficiency of 82.3%, confirming safe combustion with CO within acceptable limits. The unit is operating properly and no further corrective action was required.
Performed MVP furnace maintenance, including a combustion analysis on the natural gas-fired unit using an electronic analyzer. Readings in the flue gas stream showed O2 at 8.6%, CO2 at 6.9%, CO at 43 ppm, and steady-state efficiency of 82.3%, confirming safe combustion with CO within acceptable limits. The unit is operating properly and no further corrective action was required.
Stephanie E.
Stephanie E. Checked in
Performed MVP furnace maintenance, including a combustion analysis on the natural gas-fired unit using an electronic analyzer. Readings in the flue gas stream showed O2 at 8.6%, CO2 at 6.9%, CO at 43 ppm, and steady-state efficiency of 82.3%, confirming safe combustion with CO within acceptable limits. The unit is operating properly and no further corrective action was required.
Cuyahoga Falls, OH 44221
Performed a plumbing inspection of the gas-fired water heater and its gas supply, venting, and water shutoff components, and evaluated the installation location to determine requirements for an automatic shut-off valve. Observed a black iron gas supply line with a gas control valve, copper water supply lines with manual shutoff valves, and a properly routed exhaust vent, with no visible leaks, corrosion, or damage. Also inspected the sump pump system, which includes a battery backup unit, and found it in satisfactory condition with no visible issues; findings were documented and a quote for automatic shut-off valve installation was prepared.
Performed a plumbing inspection of the gas-fired water heater and its gas supply, venting, and water shutoff components, and evaluated the installation location to determine requirements for an automatic shut-off valve. Observed a black iron gas supply line with a gas control valve, copper water supply lines with manual shutoff valves, and a properly routed exhaust vent, with no visible leaks, corrosion, or damage. Also inspected the sump pump system, which includes a battery backup unit, and found it in satisfactory condition with no visible issues; findings were documented and a quote for automatic shut-off valve installation was prepared.
Jared K.
Jared K. Checked in
Performed a plumbing inspection of the gas-fired water heater and its gas supply, venting, and water shutoff components, and evaluated the installation location to determine requirements for an automatic shut-off valve. Observed a black iron gas supply line with a gas control valve, copper water supply lines with manual shutoff valves, and a properly routed exhaust vent, with no visible leaks, corrosion, or damage. Also inspected the sump pump system, which includes a battery backup unit, and found it in satisfactory condition with no visible issues; findings were documented and a quote for automatic shut-off valve installation was prepared.
Cuyahoga Falls, OH 44221

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image