Schedule Service

HVAC, Plumbing & Electrical in Cuyahoga Falls, OH

When you need the best home services in Cuyahoga Falls, trust the team at Blind & Sons. With over 80 years in business, our team of experts offers comprehensive HVAC, plumbing, and electrical services to ensure your home is functional and comfortable.

Our highly trained technicians are the best in the industry, and we stand behind our work with unmatched warranties and guarantees. That’s why we’re known to meet your needs and exceed your expectations!

Schedule HVAC, plumbing, or electrical services today by calling Blind & Sons at 330-362-9232!

An expert plumber skillfully repairs a leaking pipe using a tool.

Same-Day Cooling Services

Stay comfortable during the muggy season with our superior cooling services. We’re proud to offer installation, replacement, repair, and maintenance on various systems, including central air, heat pumps, and ductless mini-splits. With our extensive experience, we can handle it all, and with our available emergency AC repair, we’re there for you when you need us most!

Need Services?

Reliable Heating Services

Winters in Cuyahoga Falls can be bitterly cold and snowy. Stay warm and comfortable on even the coldest day of the year with our unmatched heating services. From installation and maintenance to repair and replacement, our skilled technicians have the tools and training to provide outstanding service for various system types, including furnaces, boilers, and Hybrid Heat. Are you stuck without heat due to a breakdown? Trust our emergency heating repair service to restore your system quickly!

Stay warm all winter by scheduling a heating service with Blind & Sons at 330-362-9232!

Air Quality Services in Cuyahoga Falls

Enjoy your time inside with indoor air quality services from Blind & Sons. Our solutions can help improve your comfort & health with services and products, including:

To schedule indoor air quality services, call 330-362-9232 today!

Dependable Electrical Services

For safe and reliable electrical services, trust the licensed electricians at Blind & Sons. Our comprehensive electrical services include general installation, replacement, repair, electrical panel services, and rewiring. We also offer specialized services, including electrical inspections, whole-home generators, EV chargers, and more!

Call Blind & Sons today at 330-362-9232 to schedule your next electrical service with our team!

Top-Rated Plumbing Services

Keep your plumbing system operating at peak performance with plumbing services from Blind & Sons. Our expert plumbers are here to handle even the most complex repairs to help protect your home from water damage and ensure that you have the reliable plumbing you need.

We also provide comprehensive water heater services for standard and tankless systems to ensure you can access the hot water you need. Plus, with drain cleaning services, we’ll remove stubborn clogs to ensure your pipes can flow freely!

Trust the plumbers at Blind & Sons! Call 330-362-9232 today to schedule service!

Choose Blind & Sons in Cuyahoga Falls

Since 1937, Blind & Sons has provided outstanding HVAC, plumbing, and electrical service to the residents of Cuyahoga Falls and Northeast Ohio. We’re proud to offer emergency heating and cooling services to ensure our customers’ comfort is never compromised. Plus, with our satisfaction guarantee, you can trust you’re only getting the best possible service from our team!

Call 330-362-9232 today to schedule HVAC, plumbing, or electrical services for your Cuyahoga Falls home!

 

Recent Jobs and Reviews in Cuyahoga Falls, OH

Cuyahoga Falls, OH at a glance

Blind and Sons has completed 20 jobs in Cuyahoga Falls, OH in October 2026.

The most recent job was on October 29, 2026.

Blind and Sons has completed 1,010 jobs in Cuyahoga Falls, OH in the last 12 months.

Job Locations and Reviews

Performed a plumbing inspection of the gas-fired water heater and its gas supply, venting, and water shutoff components, and evaluated the installation location to determine requirements for an automatic shut-off valve. Observed a black iron gas supply line with a gas control valve, copper water supply lines with manual shutoff valves, and a properly routed exhaust vent, with no visible leaks, corrosion, or damage. Also inspected the sump pump system, which includes a battery backup unit, and found it in satisfactory condition with no visible issues; findings were documented and a quote for automatic shut-off valve installation was prepared.
Performed a plumbing inspection of the gas-fired water heater and its gas supply, venting, and water shutoff components, and evaluated the installation location to determine requirements for an automatic shut-off valve. Observed a black iron gas supply line with a gas control valve, copper water supply lines with manual shutoff valves, and a properly routed exhaust vent, with no visible leaks, corrosion, or damage. Also inspected the sump pump system, which includes a battery backup unit, and found it in satisfactory condition with no visible issues; findings were documented and a quote for automatic shut-off valve installation was prepared.
Jared K.
Jared K. Checked in
Performed a plumbing inspection of the gas-fired water heater and its gas supply, venting, and water shutoff components, and evaluated the installation location to determine requirements for an automatic shut-off valve. Observed a black iron gas supply line with a gas control valve, copper water supply lines with manual shutoff valves, and a properly routed exhaust vent, with no visible leaks, corrosion, or damage. Also inspected the sump pump system, which includes a battery backup unit, and found it in satisfactory condition with no visible issues; findings were documented and a quote for automatic shut-off valve installation was prepared.
Cuyahoga Falls, OH 44221
Installed a new 80% AFUE gas furnace, connecting it to the existing supply plenum, flue venting, condensate drain line, and electrical disconnect. Replaced the flexible duct run to the bathroom boot with 6" rigid galvanized hard pipe to improve airflow and eliminate restrictions, then sealed all duct seams with foil tape.
Installed a new 80% AFUE gas furnace, connecting it to the existing supply plenum, flue venting, condensate drain line, and electrical disconnect. Replaced the flexible duct run to the bathroom boot with 6" rigid galvanized hard pipe to improve airflow and eliminate restrictions, then sealed all duct seams with foil tape.
Charles A.
Charles A. Checked in
Installed a new 80% AFUE gas furnace, connecting it to the existing supply plenum, flue venting, condensate drain line, and electrical disconnect. Replaced the flexible duct run to the bathroom boot with 6" rigid galvanized hard pipe to improve airflow and eliminate restrictions, then sealed all duct seams with foil tape.
Cuyahoga Falls, OH 44221
Performed annual furnace maintenance, including inspection of the integrated control board and verification of flame sense circuit, discharge air sensor terminals, and DIP switch configuration, with no evidence of burning, corrosion, or physical damage. Removed and inspected the flame sensor rod, checked pressure switch, wiring, and blower assembly connections, and noted light surface rust on the interior cabinet panel edge. System components were found in serviceable condition and operating as intended.
Performed annual furnace maintenance, including inspection of the integrated control board and verification of flame sense circuit, discharge air sensor terminals, and DIP switch configuration, with no evidence of burning, corrosion, or physical damage. Removed and inspected the flame sensor rod, checked pressure switch, wiring, and blower assembly connections, and noted light surface rust on the interior cabinet panel edge. System components were found in serviceable condition and operating as intended.
Taylor F.
Taylor F. Checked in
Performed annual furnace maintenance, including inspection of the integrated control board and verification of flame sense circuit, discharge air sensor terminals, and DIP switch configuration, with no evidence of burning, corrosion, or physical damage. Removed and inspected the flame sensor rod, checked pressure switch, wiring, and blower assembly connections, and noted light surface rust on the interior cabinet panel edge. System components were found in serviceable condition and operating as intended.
Cuyahoga Falls, OH 44221
Performed an on-site estimate for replacement of a 27-year-old furnace that is currently not producing heat, with replacement parts backordered 2-3 months. Inspected the flue venting, which runs through a deteriorated masonry wall penetration with visible cracking, crumbling material, and patched sealant, and found frost accumulation on the rectangular supply duct and suction line insulation, indicating a possible airflow or refrigerant-side issue to be addressed. Measured the ductwork, documented existing conditions, and quoted a full system replacement as the most reliable solution given the unit's age and extended parts lead time.
Performed an on-site estimate for replacement of a 27-year-old furnace that is currently not producing heat, with replacement parts backordered 2-3 months. Inspected the flue venting, which runs through a deteriorated masonry wall penetration with visible cracking, crumbling material, and patched sealant, and found frost accumulation on the rectangular supply duct and suction line insulation, indicating a possible airflow or refrigerant-side issue to be addressed. Measured the ductwork, documented existing conditions, and quoted a full system replacement as the most reliable solution given the unit's age and extended parts lead time.
Dustin J.
Dustin J. Checked in
Performed an on-site estimate for replacement of a 27-year-old furnace that is currently not producing heat, with replacement parts backordered 2-3 months. Inspected the flue venting, which runs through a deteriorated masonry wall penetration with visible cracking, crumbling material, and patched sealant, and found frost accumulation on the rectangular supply duct and suction line insulation, indicating a possible airflow or refrigerant-side issue to be addressed. Measured the ductwork, documented existing conditions, and quoted a full system replacement as the most reliable solution given the unit's age and extended parts lead time.
Cuyahoga Falls, OH 44221
Installed a new 80% AFUE gas furnace and connected it to the existing ductwork, sealing seams with foil-faced tape. Reconnected the black iron gas supply with a shutoff valve, union, and drip leg, applying thread sealant at the threaded joints.
Installed a new 80% AFUE gas furnace and connected it to the existing ductwork, sealing seams with foil-faced tape. Reconnected the black iron gas supply with a shutoff valve, union, and drip leg, applying thread sealant at the threaded joints.
Deontae G.
Deontae G. Checked in
Installed a new 80% AFUE gas furnace and connected it to the existing ductwork, sealing seams with foil-faced tape. Reconnected the black iron gas supply with a shutoff valve, union, and drip leg, applying thread sealant at the threaded joints.
Cuyahoga Falls, OH 44221
Cuyahoga Falls, OH - Installed a new 50-gallon water heater with a 10-year warranty, replacing corroded supply lines and installing new dielectric unions, a thermal expansion tank with shutoff, and an Active Flo system. Installed a new brass pressure reducing valve with clean copper fittings to regulate incoming water pressure and protect the plumbing system and water heater.
Nick L.
Nick L. Checked in
Installed a new 50-gallon water heater with a 10-year warranty, replacing corroded supply lines and installing new dielectric unions, a thermal expansion tank with shutoff, and an Active Flo system. Installed a new brass pressure reducing valve with clean copper fittings to regulate incoming water pressure and protect the plumbing system and water heater.
Cuyahoga Falls, OH 44223
Diagnosed a no-heat condition and found the induced draft motor receiving line voltage but failing to spin, with DC voltage at startup out of specification. Replaced the induced draft motor and the control circuit board, then verified proper startup and operation. Post-repair inspection confirmed the burners firing with a normal blue flame and the pressure switch, venting, and wiring connections in good condition.
Diagnosed a no-heat condition and found the induced draft motor receiving line voltage but failing to spin, with DC voltage at startup out of specification. Replaced the induced draft motor and the control circuit board, then verified proper startup and operation. Post-repair inspection confirmed the burners firing with a normal blue flame and the pressure switch, venting, and wiring connections in good condition.
Daniel
Daniel Checked in
Diagnosed a no-heat condition and found the induced draft motor receiving line voltage but failing to spin, with DC voltage at startup out of specification. Replaced the induced draft motor and the control circuit board, then verified proper startup and operation. Post-repair inspection confirmed the burners firing with a normal blue flame and the pressure switch, venting, and wiring connections in good condition.
Cuyahoga Falls, OH 44223
Performed a heating tune-up on a 4-year-old Lennox gas furnace, inspecting the cabinet, wiring, blower assembly, and gas valve, with no rust, damage, or abnormal conditions observed. Verified gas valve manifold pressure with a digital manometer and conducted a combustion analysis (Nat Gas), recording O2 at 7.3%, CO at 29 ppm, CO2 at 7.7%, and efficiency at 95.4%. The unit is operating properly with no issues identified.
Performed a heating tune-up on a 4-year-old Lennox gas furnace, inspecting the cabinet, wiring, blower assembly, and gas valve, with no rust, damage, or abnormal conditions observed. Verified gas valve manifold pressure with a digital manometer and conducted a combustion analysis (Nat Gas), recording O2 at 7.3%, CO at 29 ppm, CO2 at 7.7%, and efficiency at 95.4%. The unit is operating properly with no issues identified.
Colton D.
Colton D. Checked in
Performed a heating tune-up on a 4-year-old Lennox gas furnace, inspecting the cabinet, wiring, blower assembly, and gas valve, with no rust, damage, or abnormal conditions observed. Verified gas valve manifold pressure with a digital manometer and conducted a combustion analysis (Nat Gas), recording O2 at 7.3%, CO at 29 ppm, CO2 at 7.7%, and efficiency at 95.4%. The unit is operating properly with no issues identified.
Cuyahoga Falls, OH 44221
Responded to a no-heat call on a 25-year-old mobile home furnace and inspected the unit's interior cabinet and electrical control compartment, where aged, dusty wiring and wire-nut connections were observed along with significant dirt and corrosion buildup. Took measurements of the unit and cabinet area to document its dimensions and configuration, as the age and condition of the equipment limit repair viability and may support replacement planning.
Responded to a no-heat call on a 25-year-old mobile home furnace and inspected the unit's interior cabinet and electrical control compartment, where aged, dusty wiring and wire-nut connections were observed along with significant dirt and corrosion buildup. Took measurements of the unit and cabinet area to document its dimensions and configuration, as the age and condition of the equipment limit repair viability and may support replacement planning.
Hershel M.
Hershel M. Checked in
Responded to a no-heat call on a 25-year-old mobile home furnace and inspected the unit's interior cabinet and electrical control compartment, where aged, dusty wiring and wire-nut connections were observed along with significant dirt and corrosion buildup. Took measurements of the unit and cabinet area to document its dimensions and configuration, as the age and condition of the equipment limit repair viability and may support replacement planning.
Cuyahoga Falls, OH 44223
Performed an on-site estimate for replacement of an upright Carrier gas furnace installed on concrete blocks in a basement mechanical area, documenting the existing unit, 20x25 galvanized supply plenum and ductwork connections, PVC condensate drain routing, gas line and shutoff, and electrical junction. Noted the aged equipment and damp, uneven floor conditions that will need to be addressed during changeout planning.
Performed an on-site estimate for replacement of an upright Carrier gas furnace installed on concrete blocks in a basement mechanical area, documenting the existing unit, 20x25 galvanized supply plenum and ductwork connections, PVC condensate drain routing, gas line and shutoff, and electrical junction. Noted the aged equipment and damp, uneven floor conditions that will need to be addressed during changeout planning.
Kevin T.
Kevin T. Checked in
Performed an on-site estimate for replacement of an upright Carrier gas furnace installed on concrete blocks in a basement mechanical area, documenting the existing unit, 20x25 galvanized supply plenum and ductwork connections, PVC condensate drain routing, gas line and shutoff, and electrical junction. Noted the aged equipment and damp, uneven floor conditions that will need to be addressed during changeout planning.
Cuyahoga Falls, OH 44221
Performed scheduled heating system maintenance, including inspection of the control board, DIP switch configuration, and diagnostic display, which indicated normal operation. Inspected the blower assembly and found heavy dust and debris accumulation on the squirrel-cage wheel fins and housing, restricting airflow and reducing efficiency. Cleaned the blower wheel and housing to restore proper airflow and system performance.
Performed scheduled heating system maintenance, including inspection of the control board, DIP switch configuration, and diagnostic display, which indicated normal operation. Inspected the blower assembly and found heavy dust and debris accumulation on the squirrel-cage wheel fins and housing, restricting airflow and reducing efficiency. Cleaned the blower wheel and housing to restore proper airflow and system performance.
Derrick M.
Derrick M. Checked in
Performed scheduled heating system maintenance, including inspection of the control board, DIP switch configuration, and diagnostic display, which indicated normal operation. Inspected the blower assembly and found heavy dust and debris accumulation on the squirrel-cage wheel fins and housing, restricting airflow and reducing efficiency. Cleaned the blower wheel and housing to restore proper airflow and system performance.
Cuyahoga Falls, OH 44223
Performed a seasonal tune-up on a 5-year-old Lennox gas furnace in preparation for winter operation, including inspection of key components and verification of proper system function. Photos show only a thin L-shaped metal rod on fabric and no furnace components, so no specific findings or repairs are documented here.
Performed a seasonal tune-up on a 5-year-old Lennox gas furnace in preparation for winter operation, including inspection of key components and verification of proper system function. Photos show only a thin L-shaped metal rod on fabric and no furnace components, so no specific findings or repairs are documented here.
Jesus M.
Jesus M. Checked in
Performed a seasonal tune-up on a 5-year-old Lennox gas furnace in preparation for winter operation, including inspection of key components and verification of proper system function. Photos show only a thin L-shaped metal rod on fabric and no furnace components, so no specific findings or repairs are documented here.
Cuyahoga Falls, OH 44223
Responded to a reported water leak in the basement and no-flow condition at the shower head. Inspected the water heater and overhead copper supply piping and fittings, along with the bathroom vanity fixtures, to diagnose the loss of water flow and check for leak sources. Completed the membership renewal with the technician.
Responded to a reported water leak in the basement and no-flow condition at the shower head. Inspected the water heater and overhead copper supply piping and fittings, along with the bathroom vanity fixtures, to diagnose the loss of water flow and check for leak sources. Completed the membership renewal with the technician.
Denny J.
Denny J. Checked in
Responded to a reported water leak in the basement and no-flow condition at the shower head. Inspected the water heater and overhead copper supply piping and fittings, along with the bathroom vanity fixtures, to diagnose the loss of water flow and check for leak sources. Completed the membership renewal with the technician.
Cuyahoga Falls, OH 44221
Inspected a 6-year-old Bradford White gas water heater reported as leaking; the tank, drain pan, and surrounding connections showed no visible leaks, rust, or damage, and the expansion tank, gas shutoff, flue, and water lines were in good condition. Verified static water pressure at an exterior hose spigot using a pressure gauge to rule out excessive system pressure as a cause of the reported leak. The unit appears to be in serviceable condition, and no leak source was identified at the time of inspection.
Inspected a 6-year-old Bradford White gas water heater reported as leaking; the tank, drain pan, and surrounding connections showed no visible leaks, rust, or damage, and the expansion tank, gas shutoff, flue, and water lines were in good condition. Verified static water pressure at an exterior hose spigot using a pressure gauge to rule out excessive system pressure as a cause of the reported leak. The unit appears to be in serviceable condition, and no leak source was identified at the time of inspection.
Nick L.
Nick L. Checked in
Inspected a 6-year-old Bradford White gas water heater reported as leaking; the tank, drain pan, and surrounding connections showed no visible leaks, rust, or damage, and the expansion tank, gas shutoff, flue, and water lines were in good condition. Verified static water pressure at an exterior hose spigot using a pressure gauge to rule out excessive system pressure as a cause of the reported leak. The unit appears to be in serviceable condition, and no leak source was identified at the time of inspection.
Cuyahoga Falls, OH 44223
Installed a new 80% AFUE Lennox gas furnace on concrete blocks in the utility closet, connecting the metal flue with elbow to the existing venting and routing the PVC condensate drain along the wall. Reconnected the flexible conduit and service disconnect switch to the unit's electrical supply, and tied the furnace into the existing coil cabinet, ductwork, refrigerant lines, and air cleaner. System was verified for proper installation with no visible damage or leaks.
Installed a new 80% AFUE Lennox gas furnace on concrete blocks in the utility closet, connecting the metal flue with elbow to the existing venting and routing the PVC condensate drain along the wall. Reconnected the flexible conduit and service disconnect switch to the unit's electrical supply, and tied the furnace into the existing coil cabinet, ductwork, refrigerant lines, and air cleaner. System was verified for proper installation with no visible damage or leaks.
Deontae G.
Deontae G. Checked in
Installed a new 80% AFUE Lennox gas furnace on concrete blocks in the utility closet, connecting the metal flue with elbow to the existing venting and routing the PVC condensate drain along the wall. Reconnected the flexible conduit and service disconnect switch to the unit's electrical supply, and tied the furnace into the existing coil cabinet, ductwork, refrigerant lines, and air cleaner. System was verified for proper installation with no visible damage or leaks.
Cuyahoga Falls, OH 44223
Performed annual maintenance on a 3-year-old natural gas furnace, including a combustion analysis with a Bacharach analyzer to verify safe and efficient operation. Readings were within normal range: O2 6.9%, CO2 7.9%, CO 30 ppm, stack temperature 104°F, and steady-state efficiency of 95.6%. The unit is operating properly with no deficiencies noted.
Performed annual maintenance on a 3-year-old natural gas furnace, including a combustion analysis with a Bacharach analyzer to verify safe and efficient operation. Readings were within normal range: O2 6.9%, CO2 7.9%, CO 30 ppm, stack temperature 104°F, and steady-state efficiency of 95.6%. The unit is operating properly with no deficiencies noted.
Jesus M.
Jesus M. Checked in
Performed annual maintenance on a 3-year-old natural gas furnace, including a combustion analysis with a Bacharach analyzer to verify safe and efficient operation. Readings were within normal range: O2 6.9%, CO2 7.9%, CO 30 ppm, stack temperature 104°F, and steady-state efficiency of 95.6%. The unit is operating properly with no deficiencies noted.
Cuyahoga Falls, OH 44223
Installed a new 80% AFUE dual-fuel furnace in the utility closet, connecting it to the existing galvanized flue venting, supply plenum, and black iron gas supply with shutoff valve. Reconnected the humidifier and associated condensate/water lines, secured and sealed the ductwork connections with foil-faced tape, and verified all gas and venting connections were properly installed.
Installed a new 80% AFUE dual-fuel furnace in the utility closet, connecting it to the existing galvanized flue venting, supply plenum, and black iron gas supply with shutoff valve. Reconnected the humidifier and associated condensate/water lines, secured and sealed the ductwork connections with foil-faced tape, and verified all gas and venting connections were properly installed.
Charles A.
Charles A. Checked in
Installed a new 80% AFUE dual-fuel furnace in the utility closet, connecting it to the existing galvanized flue venting, supply plenum, and black iron gas supply with shutoff valve. Reconnected the humidifier and associated condensate/water lines, secured and sealed the ductwork connections with foil-faced tape, and verified all gas and venting connections were properly installed.
Cuyahoga Falls, OH 44223
Performed a scheduled heating system maintenance visit, including inspection and servicing of the flame sensor/ignitor assembly and examination of the coil section and surrounding cabinet components. Noted oxidation and residue on several coil end-plate tube joints, which were marked for monitoring, with no frost, ice, or other damage observed. System was left in proper working condition.
Performed a scheduled heating system maintenance visit, including inspection and servicing of the flame sensor/ignitor assembly and examination of the coil section and surrounding cabinet components. Noted oxidation and residue on several coil end-plate tube joints, which were marked for monitoring, with no frost, ice, or other damage observed. System was left in proper working condition.
Taylor F.
Taylor F. Checked in
Performed a scheduled heating system maintenance visit, including inspection and servicing of the flame sensor/ignitor assembly and examination of the coil section and surrounding cabinet components. Noted oxidation and residue on several coil end-plate tube joints, which were marked for monitoring, with no frost, ice, or other damage observed. System was left in proper working condition.
Cuyahoga Falls, OH 44223
Cleared the clogged kitchen double-basin drain system by accessing and servicing the ABS drain assembly, P-trap, and tailpiece connections beneath the sink, removing the obstruction and restoring full flow from both basins. Inspected the surrounding under-sink components and noted corrosion on the angle stop valves and drain fitting at the cabinet floor, along with minor rust on the underside of the right basin, for future monitoring.
Cleared the clogged kitchen double-basin drain system by accessing and servicing the ABS drain assembly, P-trap, and tailpiece connections beneath the sink, removing the obstruction and restoring full flow from both basins. Inspected the surrounding under-sink components and noted corrosion on the angle stop valves and drain fitting at the cabinet floor, along with minor rust on the underside of the right basin, for future monitoring.
Mark W.
Mark W. Checked in
Cleared the clogged kitchen double-basin drain system by accessing and servicing the ABS drain assembly, P-trap, and tailpiece connections beneath the sink, removing the obstruction and restoring full flow from both basins. Inspected the surrounding under-sink components and noted corrosion on the angle stop valves and drain fitting at the cabinet floor, along with minor rust on the underside of the right basin, for future monitoring.
Cuyahoga Falls, OH 44221
Performed annual maintenance on a six-year-old gas furnace, including inspection of the hot surface igniter/flame sensor assembly, which showed light discoloration and residue buildup, and verified combustion performance with an electronic analyzer. Readings were within normal operating range (CO 25 ppm, CO2 7.6%, stack temperature 104°F, efficiency 95.4%), and no operational issues were found.
Performed annual maintenance on a six-year-old gas furnace, including inspection of the hot surface igniter/flame sensor assembly, which showed light discoloration and residue buildup, and verified combustion performance with an electronic analyzer. Readings were within normal operating range (CO 25 ppm, CO2 7.6%, stack temperature 104°F, efficiency 95.4%), and no operational issues were found.
Jesus M.
Jesus M. Checked in
Performed annual maintenance on a six-year-old gas furnace, including inspection of the hot surface igniter/flame sensor assembly, which showed light discoloration and residue buildup, and verified combustion performance with an electronic analyzer. Readings were within normal operating range (CO 25 ppm, CO2 7.6%, stack temperature 104°F, efficiency 95.4%), and no operational issues were found.
Cuyahoga Falls, OH 44223

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image