Since 1937, Blind & Sons has proudly served Medina, OH homeowners with expert HVAC, plumbing, and electrical services. Our licensed and highly trained team is committed to delivering top-notch service backed by a 100% satisfaction guarantee. From heating and cooling repairs to plumbing installations and electrical inspections, we offer comprehensive home services in Medina that ensure your home stays comfortable, safe, and efficient all year long.

Need trusted local service in Medina? Call Blind & Sons at 330-362-9232 or contact us online to schedule an appointment today.

Serving the Heart of Medina County

Situated in the center of Medina County, Medina, OH combines rich history with modern living. The city is known for its beautifully preserved 19th-century architecture, tree-lined streets, and the bustling charm of Medina Square, where local shops, restaurants, and community events create a vibrant hub for residents and visitors alike. From historic homes on Broadway Street to newer developments in neighborhoods like Blue Heron and Fox Meadow, Medina offers diverse living options that require equally diverse home services.

At Blind & Sons, we take pride in being part of this growing and thriving community. We understand the specific challenges homeowners face in Medina—from aging infrastructure and evolving energy efficiency standards to the seasonal temperature swings that demand reliable HVAC systems. Our technicians live and work locally, giving them unique insight into the needs of Medina homes. Whether you’re upgrading an older home or maintaining a modern one, we deliver custom solutions built on trust, local expertise, and long-standing commitment to the region.

Complete Heating Services in Medina, OH

When snow blankets the streets of Medina and temperatures drop below freezing, having a reliable heating system is more than just comfort—it’s a necessity. At Blind & Sons, we specialize in full-service heating solutions designed specifically for the needs of Medina homes. Whether you live in a century-old colonial near Medina Square or a modern build on the outskirts, our team ensures your home stays warm and safe when it matters most:

Need Services?

Air Conditioning Services to Keep Medina Homes Cool

Summer days in Medina can go from pleasant to sweltering quickly. That’s why so many homeowners throughout the area—from the tree-lined streets near Medina Square to newer subdivisions like Windfall Estates—count on Blind & Sons to keep their homes cool and energy-efficient. Our expert Medina cooling services are built with those local details in mind, ensuring each system we service is tailored to perform at its best:

  • AC Repairs: Fast service for issues like warm airflow, refrigerant leaks, or noisy operation.
  • New AC Installations: We’ll help you choose the right system and install it to manufacturer standards.
  • AC Replacements: Upgrade to a more energy-efficient model that better serves your cooling needs.
  • AC Maintenance: Regular servicing to ensure performance, improve efficiency, and reduce long-term costs.
  • Heat Pumps & Ductless Mini-Splits: Ideal for zoned cooling or homes without existing ductwork.
  • Emergency AC Repair: Immediate support for system failures during extreme heat.

Indoor Air Quality Services in Medina, OH

Poor indoor air can lead to allergy flare-ups, respiratory issues, and discomfort. Blind & Sons helps you breathe easier with professional IAQ services:

Our solutions are customized to match your home’s layout and your family’s health needs.

Expert Electrical Services in Medina for Safe, Reliable Power

Young electrical technician writes in a notebook the data collected on a residential electric panel

From the kitchen appliances that fuel your mornings to the smart devices that keep you connected, electrical systems are the hidden backbone of modern living in Medina. Whether you’re updating an older home near Medina’s historic district or building a new one in a growing development, our team ensures your electrical systems are efficient, safe, and built to last. We keep your home powered and protected with:

Need Services?

Full-Service Plumbing in Medina, OH

Whether it’s a slow leak or a major plumbing emergency, Blind & Sons provides fast, effective plumbing services across Medina. We offer:

Why Choose Blind & Sons in Medina, OH?

Blind & Sons has earned the trust of Medina families for generations. Here’s what sets us apart:

  • Emergency HVAC Service: We’re here for you when you need us.
  • Licensed, Background-Checked Technicians: Skilled, respectful professionals in every home.
  • MVP Maintenance Program: Preventative care plans that save money and extend system life.
  • Flexible Financing & Online Scheduling: Convenience at your fingertips.
  • Referral Rewards & Special Offers: Save more while sharing our services.
  • 100% Satisfaction Guarantee: We’re not satisfied until you are.

Whether you’re near Medina Square, in the Heritage Woods neighborhood, or anywhere else in the city, we’re your local partner for total home comfort.

Schedule HVAC, Plumbing, or Electrical Services in Medina Today

When it comes to your home, there’s no room for guesswork. Trust the team at Blind & Sons for reliable service that delivers real value. We proudly serve Medina and surrounding areas with professionalism, transparency, and top-tier customer care.

Call 330-362-9232 or contact us online to book HVAC, plumbing, electrical, or indoor air quality services in Medina, OH today.

 

Recent Jobs and Reviews in Medina, OH

Medina, OH at a glance

Blind and Sons has completed 20 jobs in Medina, OH in September 2026.

The most recent job was on September 30, 2026.

Blind and Sons has completed 746 jobs in Medina, OH in the last 12 months.

Job Locations and Reviews

Completed scheduled maintenance on 6-year-old air conditioning system and 1-year-old furnace. Inspected evaporator coil assembly, which showed normal condensation buildup during operation, indicating proper cooling function. Verified refrigerant lines, fin spacing, and overall system cleanliness with no issues identified.
Completed scheduled maintenance on 6-year-old air conditioning system and 1-year-old furnace. Inspected evaporator coil assembly, which showed normal condensation buildup during operation, indicating proper cooling function. Verified refrigerant lines, fin spacing, and overall system cleanliness with no issues identified.
Jesus M.
Jesus M. Checked in
Completed scheduled maintenance on 6-year-old air conditioning system and 1-year-old furnace. Inspected evaporator coil assembly, which showed normal condensation buildup during operation, indicating proper cooling function. Verified refrigerant lines, fin spacing, and overall system cleanliness with no issues identified.
Medina, OH 44256
Performed comprehensive tune-up on 3-year-old Carrier gas furnace unit located in basement utility room. Conducted full system inspection, verified proper operation of all components, inspected and documented air filter condition, and confirmed unit is operating within manufacturer specifications for the heating season.
Performed comprehensive tune-up on 3-year-old Carrier gas furnace unit located in basement utility room. Conducted full system inspection, verified proper operation of all components, inspected and documented air filter condition, and confirmed unit is operating within manufacturer specifications for the heating season.
Kevin D.
Kevin D. Checked in
Performed comprehensive tune-up on 3-year-old Carrier gas furnace unit located in basement utility room. Conducted full system inspection, verified proper operation of all components, inspected and documented air filter condition, and confirmed unit is operating within manufacturer specifications for the heating season.
Medina, OH 44256
Performed scheduled maintenance on residential Generac standby generator unit. Conducted comprehensive inspection of internal components including engine, fuel system, coiled hoses, and mechanical assemblies. Verified proper operation of all systems, checked PVC exhaust piping connections and mounting integrity, and confirmed unit remains in good working condition for reliable backup power service.
Performed scheduled maintenance on residential Generac standby generator unit. Conducted comprehensive inspection of internal components including engine, fuel system, coiled hoses, and mechanical assemblies. Verified proper operation of all systems, checked PVC exhaust piping connections and mounting integrity, and confirmed unit remains in good working condition for reliable backup power service.
Eric L.
Eric L. Checked in
Performed scheduled maintenance on residential Generac standby generator unit. Conducted comprehensive inspection of internal components including engine, fuel system, coiled hoses, and mechanical assemblies. Verified proper operation of all systems, checked PVC exhaust piping connections and mounting integrity, and confirmed unit remains in good working condition for reliable backup power service.
Medina, OH 44256
Completed comprehensive tune-up on 15-year-old furnace system per customer's request for after 3PM service. Performed thorough inspection of heat exchanger assembly, verified structural integrity of aluminum tubes and junction connections, and confirmed proper seating of all fasteners. Inspected control board wiring harnesses, verified secure connections of all electrical bundles, and confirmed proper voltage at circuit boards. All components found to be in functional condition with normal wear appropriate for unit age, system tested and operating within manufacturer specifications.
Completed comprehensive tune-up on 15-year-old furnace system per customer's request for after 3PM service. Performed thorough inspection of heat exchanger assembly, verified structural integrity of aluminum tubes and junction connections, and confirmed proper seating of all fasteners. Inspected control board wiring harnesses, verified secure connections of all electrical bundles, and confirmed proper voltage at circuit boards. All components found to be in functional condition with normal wear appropriate for unit age, system tested and operating within manufacturer specifications.
Jibreel H.
Jibreel H. Checked in
Completed comprehensive tune-up on 15-year-old furnace system per customer's request for after 3PM service. Performed thorough inspection of heat exchanger assembly, verified structural integrity of aluminum tubes and junction connections, and confirmed proper seating of all fasteners. Inspected control board wiring harnesses, verified secure connections of all electrical bundles, and confirmed proper voltage at circuit boards. All components found to be in functional condition with normal wear appropriate for unit age, system tested and operating within manufacturer specifications.
Medina, OH 44256
Responded to low water pressure complaint regarding DAB Esybox mini booster pump installed approximately three months prior. Customer reported inadequate performance affecting in-ground sprinkler system operation. Upon arrival, conducted visual inspection of exterior booster pump installation and associated PVC piping configuration. Verified mounting hardware and backflow preventer assembly condition. Checked system pressure gauge readings and evaluated pump performance parameters. Inspected brass fittings, compression connections, and valve assemblies for proper operation. Assessed pump control settings and pressure switch calibration. Documented current system configuration with photographs showing exterior wall-mounted installation and pressure gauge assembly. Verified electrical connections and pump cycling operation. System evaluation completed to determine cause of reduced water pressure and diminished sprinkler performance compared to initial installation standards.
Responded to low water pressure complaint regarding DAB Esybox mini booster pump installed approximately three months prior. Customer reported inadequate performance affecting in-ground sprinkler system operation. Upon arrival, conducted visual inspection of exterior booster pump installation and associated PVC piping configuration. Verified mounting hardware and backflow preventer assembly condition. Checked system pressure gauge readings and evaluated pump performance parameters. Inspected brass fittings, compression connections, and valve assemblies for proper operation. Assessed pump control settings and pressure switch calibration. Documented current system configuration with photographs showing exterior wall-mounted installation and pressure gauge assembly. Verified electrical connections and pump cycling operation. System evaluation completed to determine cause of reduced water pressure and diminished sprinkler performance compared to initial installation standards.
Jared K.
Jared K. Checked in
Responded to low water pressure complaint regarding DAB Esybox mini booster pump installed approximately three months prior. Customer reported inadequate performance affecting in-ground sprinkler system operation. Upon arrival, conducted visual inspection of exterior booster pump installation and associated PVC piping configuration. Verified mounting hardware and backflow preventer assembly condition. Checked system pressure gauge readings and evaluated pump performance parameters. Inspected brass fittings, compression connections, and valve assemblies for proper operation. Assessed pump control settings and pressure switch calibration. Documented current system configuration with photographs showing exterior wall-mounted installation and pressure gauge assembly. Verified electrical connections and pump cycling operation. System evaluation completed to determine cause of reduced water pressure and diminished sprinkler performance compared to initial installation standards.
Medina, OH 44256
Completed scheduled contract maintenance on a residential furnace approximately 2 years old. Performed comprehensive tune-up service including visual inspection of all interior components, electrical connections, and control systems. Verified proper operation of blower motor assembly, examined all wire harnesses and connections for signs of wear or damage, and confirmed circuit board functionality. Inspected PVC venting connections, refrigerant lines, and all mechanical components within the cabinet. All systems found operating within normal parameters with no deficiencies noted. Unit is in excellent condition with maintenance protection valid through 2026.
Completed scheduled contract maintenance on a residential furnace approximately 2 years old. Performed comprehensive tune-up service including visual inspection of all interior components, electrical connections, and control systems. Verified proper operation of blower motor assembly, examined all wire harnesses and connections for signs of wear or damage, and confirmed circuit board functionality. Inspected PVC venting connections, refrigerant lines, and all mechanical components within the cabinet. All systems found operating within normal parameters with no deficiencies noted. Unit is in excellent condition with maintenance protection valid through 2026.
Matthew F.
Matthew F. Checked in
Completed scheduled contract maintenance on a residential furnace approximately 2 years old. Performed comprehensive tune-up service including visual inspection of all interior components, electrical connections, and control systems. Verified proper operation of blower motor assembly, examined all wire harnesses and connections for signs of wear or damage, and confirmed circuit board functionality. Inspected PVC venting connections, refrigerant lines, and all mechanical components within the cabinet. All systems found operating within normal parameters with no deficiencies noted. Unit is in excellent condition with maintenance protection valid through 2026.
Medina, OH 44256
Responded to water leak complaint on 2-year-old Lennox AC unit (EL18XCV-036-230A03). Found condensate catch basin malfunctioning, causing water to discharge from overflow pipe onto floor. Inspected condensate drain system including PVC drainage lines and internal catch pan. Cleared blockage in primary drain line, verified proper pitch and flow through condensate piping, and tested safety float switch operation. Confirmed unit cycling properly with condensate draining correctly through primary line without overflow. System returned to normal operation with no further water leakage observed.
Responded to water leak complaint on 2-year-old Lennox AC unit (EL18XCV-036-230A03). Found condensate catch basin malfunctioning, causing water to discharge from overflow pipe onto floor. Inspected condensate drain system including PVC drainage lines and internal catch pan. Cleared blockage in primary drain line, verified proper pitch and flow through condensate piping, and tested safety float switch operation. Confirmed unit cycling properly with condensate draining correctly through primary line without overflow. System returned to normal operation with no further water leakage observed.
Stephanie E.
Stephanie E. Checked in
Responded to water leak complaint on 2-year-old Lennox AC unit (EL18XCV-036-230A03). Found condensate catch basin malfunctioning, causing water to discharge from overflow pipe onto floor. Inspected condensate drain system including PVC drainage lines and internal catch pan. Cleared blockage in primary drain line, verified proper pitch and flow through condensate piping, and tested safety float switch operation. Confirmed unit cycling properly with condensate draining correctly through primary line without overflow. System returned to normal operation with no further water leakage observed.
Medina, OH 44256
Completed MVP cooling maintenance visit on HVAC system. Performed system inspection, checked air filter condition and airflow, and measured static pressure readings using digital manometer which indicated 0.73 inches of water column. Verified proper operation of blower motor, inspected electrical connections and wiring, and confirmed condensate drainage system functioning correctly.
Completed MVP cooling maintenance visit on HVAC system. Performed system inspection, checked air filter condition and airflow, and measured static pressure readings using digital manometer which indicated 0.73 inches of water column. Verified proper operation of blower motor, inspected electrical connections and wiring, and confirmed condensate drainage system functioning correctly.
Matthew F.
Matthew F. Checked in
Completed MVP cooling maintenance visit on HVAC system. Performed system inspection, checked air filter condition and airflow, and measured static pressure readings using digital manometer which indicated 0.73 inches of water column. Verified proper operation of blower motor, inspected electrical connections and wiring, and confirmed condensate drainage system functioning correctly.
Medina, OH 44256
Completed comprehensive MVP Cool maintenance on an 18-year-old outdoor condensing unit. Performed standard preventive maintenance procedures including inspection of fan motor operation, electrical connections, and refrigerant lines. Unit showing age-appropriate wear with weathering on exterior housing and surrounding vegetation requiring clearance for proper airflow and accessibility during future service visits.
Completed comprehensive MVP Cool maintenance on an 18-year-old outdoor condensing unit. Performed standard preventive maintenance procedures including inspection of fan motor operation, electrical connections, and refrigerant lines. Unit showing age-appropriate wear with weathering on exterior housing and surrounding vegetation requiring clearance for proper airflow and accessibility during future service visits.
Jibreel H.
Jibreel H. Checked in
Completed comprehensive MVP Cool maintenance on an 18-year-old outdoor condensing unit. Performed standard preventive maintenance procedures including inspection of fan motor operation, electrical connections, and refrigerant lines. Unit showing age-appropriate wear with weathering on exterior housing and surrounding vegetation requiring clearance for proper airflow and accessibility during future service visits.
Medina, OH 44256
Medina, OH - Responded to service call for leaking tanked water heater. Upon inspection, confirmed active leak from residential water heater requiring replacement. Documented existing plumbing configuration including copper supply lines, expansion tank, and associated safety equipment including carbon monoxide detector in mechanical room.
Travis B.
Travis B. Checked in
Responded to service call for leaking tanked water heater. Upon inspection, confirmed active leak from residential water heater requiring replacement. Documented existing plumbing configuration including copper supply lines, expansion tank, and associated safety equipment including carbon monoxide detector in mechanical room.
Medina, OH 44256
Responded to no-heat call on 10-year-old furnace. Upon arrival, performed diagnostic inspection of gas furnace system. Accessed interior components and conducted visual inspection of all major assemblies including blower motor, control board, wiring connections, and burner assembly.

Inspected burner assembly and confirmed proper flame ignition pattern with characteristic blue flames across burner rack. Verified gas valve operation and examined all electrical connections throughout the unit, including wire harnesses, connectors, and wire nuts for signs of looseness, corrosion, or damage. Checked control board for proper function and examined all safety switches and limit controls.

Tested system operation and confirmed furnace successfully ignited and cycled properly. System now heating normally with all components functioning as designed. Unit returned to full operational status.
Responded to no-heat call on 10-year-old furnace. Upon arrival, performed diagnostic inspection of gas furnace system. Accessed interior components and conducted visual inspection of all major assemblies including blower motor, control board, wiring connections, and burner assembly.

Inspected burner assembly and confirmed proper flame ignition pattern with characteristic blue flames across burner rack. Verified gas valve operation and examined all electrical connections throughout the unit, including wire harnesses, connectors, and wire nuts for signs of looseness, corrosion, or damage. Checked control board for proper function and examined all safety switches and limit controls.

Tested system operation and confirmed furnace successfully ignited and cycled properly. System now heating normally with all components functioning as designed. Unit returned to full operational status.
Jibreel H.
Jibreel H. Checked in
Responded to no-heat call on 10-year-old furnace. Upon arrival, performed diagnostic inspection of gas furnace system. Accessed interior components and conducted visual inspection of all major assemblies including blower motor, control board, wiring connections, and burner assembly. Inspected burner assembly and confirmed proper flame ignition pattern with characteristic blue flames across burner rack. Verified gas valve operation and examined all electrical connections throughout the unit, including wire harnesses, connectors, and wire nuts for signs of looseness, corrosion, or damage. Checked control board for proper function and examined all safety switches and limit controls. Tested system operation and confirmed furnace successfully ignited and cycled properly. System now heating normally with all components functioning as designed. Unit returned to full operational status.
Medina, OH 44256
Medina, OH - Completed installation of a new black finished flange assembly for the garbage disposal unit. The replacement flange was installed on the stainless steel sink basin, securing the Badger disposal unit connection. Work included proper sealing and mounting of the disposal flange to ensure leak-free operation.
Jared K.
Jared K. Checked in
Completed installation of a new black finished flange assembly for the garbage disposal unit. The replacement flange was installed on the stainless steel sink basin, securing the Badger disposal unit connection. Work included proper sealing and mounting of the disposal flange to ensure leak-free operation.
Medina, OH 44256
Completed scheduled maintenance on 13-year-old gas heating system. Performed electrical diagnostics using clamp meter to verify proper amperage draw and tested capacitor functionality, which measured 76.53 microfarads and within acceptable operating range. All components inspected and system operating normally with no immediate service needs identified.
Completed scheduled maintenance on 13-year-old gas heating system. Performed electrical diagnostics using clamp meter to verify proper amperage draw and tested capacitor functionality, which measured 76.53 microfarads and within acceptable operating range. All components inspected and system operating normally with no immediate service needs identified.
Matthew F.
Matthew F. Checked in
Completed scheduled maintenance on 13-year-old gas heating system. Performed electrical diagnostics using clamp meter to verify proper amperage draw and tested capacitor functionality, which measured 76.53 microfarads and within acceptable operating range. All components inspected and system operating normally with no immediate service needs identified.
Medina, OH 44256
Medina, OH - Inspected 7-8 year old electric water heater reported as non-functional. Upon arrival, found extensive rust-colored corrosion staining running vertically down the front of the tank, with visible moisture damage on the concrete floor surrounding the base of the unit. The water heater exhibited signs of tank failure with standing water present beneath the unit. Documented the condition of the failed water heater with photographs showing the deteriorated state of the tank, corroded exterior, and water damage to the surrounding area. Provided free estimate for complete water heater replacement.
Craig S.
Craig S. Checked in
Inspected 7-8 year old electric water heater reported as non-functional. Upon arrival, found extensive rust-colored corrosion staining running vertically down the front of the tank, with visible moisture damage on the concrete floor surrounding the base of the unit. The water heater exhibited signs of tank failure with standing water present beneath the unit. Documented the condition of the failed water heater with photographs showing the deteriorated state of the tank, corroded exterior, and water damage to the surrounding area. Provided free estimate for complete water heater replacement.
Medina, OH 44256
Excavated and cleaned trench around above-ground pool perimeter in preparation for electrical inspection. Documented all electrical connections with photographs showing exposed conduit and wiring installations. Coordinated with inspector onsite and completed backfill of trench following successful inspection approval.
Excavated and cleaned trench around above-ground pool perimeter in preparation for electrical inspection. Documented all electrical connections with photographs showing exposed conduit and wiring installations. Coordinated with inspector onsite and completed backfill of trench following successful inspection approval.
Landon M.
Landon M. Checked in
Excavated and cleaned trench around above-ground pool perimeter in preparation for electrical inspection. Documented all electrical connections with photographs showing exposed conduit and wiring installations. Coordinated with inspector onsite and completed backfill of trench following successful inspection approval.
Medina, OH 44256
Installed two new dedicated 120V circuits for exterior holiday decoration outlets. First circuit was run from the basement subpanel to a new weatherproof receptacle mounted near the front of the home at foundation level. Second circuit was installed from the main electrical panel to a new exterior outlet positioned just inside the fence line near the garage area. Both circuits were wired with appropriate gauge copper conductors, protected with GFCI breakers, and terminated in weather-resistant outlet boxes with in-use covers mounted on the exterior brick foundation. All work completed to current NEC standards for outdoor receptacle installations.
Installed two new dedicated 120V circuits for exterior holiday decoration outlets. First circuit was run from the basement subpanel to a new weatherproof receptacle mounted near the front of the home at foundation level. Second circuit was installed from the main electrical panel to a new exterior outlet positioned just inside the fence line near the garage area. Both circuits were wired with appropriate gauge copper conductors, protected with GFCI breakers, and terminated in weather-resistant outlet boxes with in-use covers mounted on the exterior brick foundation. All work completed to current NEC standards for outdoor receptacle installations.
Austin B.
Austin B. Checked in
Installed two new dedicated 120V circuits for exterior holiday decoration outlets. First circuit was run from the basement subpanel to a new weatherproof receptacle mounted near the front of the home at foundation level. Second circuit was installed from the main electrical panel to a new exterior outlet positioned just inside the fence line near the garage area. Both circuits were wired with appropriate gauge copper conductors, protected with GFCI breakers, and terminated in weather-resistant outlet boxes with in-use covers mounted on the exterior brick foundation. All work completed to current NEC standards for outdoor receptacle installations.
Medina, OH 44256
Performed comprehensive HVAC maintenance including thorough cleaning of the squirrel cage blower wheel to remove accumulated dust and debris, cleaned the indoor evaporator coil, and completed full heating system maintenance. No parts replacement was required to restore the system to optimal operating condition.
Performed comprehensive HVAC maintenance including thorough cleaning of the squirrel cage blower wheel to remove accumulated dust and debris, cleaned the indoor evaporator coil, and completed full heating system maintenance. No parts replacement was required to restore the system to optimal operating condition.
Frank W.
Frank W. Checked in
Performed comprehensive HVAC maintenance including thorough cleaning of the squirrel cage blower wheel to remove accumulated dust and debris, cleaned the indoor evaporator coil, and completed full heating system maintenance. No parts replacement was required to restore the system to optimal operating condition.
Medina, OH 44256
Completed maintenance value plan heating inspection on two furnace systems. Performed comprehensive system diagnostics using digital manifold gauges to verify proper refrigerant pressures and operational parameters. Inspected all refrigerant line connections, mounting hardware, and interior cabinet components for both units, confirming secure copper line installations and proper fastening. All systems operating within normal specifications with no deficiencies noted.
Completed maintenance value plan heating inspection on two furnace systems. Performed comprehensive system diagnostics using digital manifold gauges to verify proper refrigerant pressures and operational parameters. Inspected all refrigerant line connections, mounting hardware, and interior cabinet components for both units, confirming secure copper line installations and proper fastening. All systems operating within normal specifications with no deficiencies noted.
Matthew F.
Matthew F. Checked in
Completed maintenance value plan heating inspection on two furnace systems. Performed comprehensive system diagnostics using digital manifold gauges to verify proper refrigerant pressures and operational parameters. Inspected all refrigerant line connections, mounting hardware, and interior cabinet components for both units, confirming secure copper line installations and proper fastening. All systems operating within normal specifications with no deficiencies noted.
Medina, OH 44256
Completed replacement of two 90% AFUE furnaces at residential property. Both units were successfully installed with new exterior PVC intake and exhaust venting terminations visible on the home's exterior walls. All venting was properly sealed, secured, and positioned according to manufacturer specifications and local building codes to ensure safe operation and optimal efficiency.
Completed replacement of two 90% AFUE furnaces at residential property. Both units were successfully installed with new exterior PVC intake and exhaust venting terminations visible on the home's exterior walls. All venting was properly sealed, secured, and positioned according to manufacturer specifications and local building codes to ensure safe operation and optimal efficiency.
Jay E.
Jay E. Checked in
Completed replacement of two 90% AFUE furnaces at residential property. Both units were successfully installed with new exterior PVC intake and exhaust venting terminations visible on the home's exterior walls. All venting was properly sealed, secured, and positioned according to manufacturer specifications and local building codes to ensure safe operation and optimal efficiency.
Medina, OH 44256
Completed electrical estimate for Kohler generator installation requiring propane fuel source. Assessed existing dual-meter residential electrical service with Landis+Gyr and Milbank meters, documented current panel configuration including main distribution panel with multiple circuit breakers and two additional sub-panels mounted on OSB backing board in basement utility area. Evaluated electrical infrastructure, conduit routing, and available space to determine generator integration requirements and transfer switch placement for seamless backup power system installation.
Completed electrical estimate for Kohler generator installation requiring propane fuel source. Assessed existing dual-meter residential electrical service with Landis+Gyr and Milbank meters, documented current panel configuration including main distribution panel with multiple circuit breakers and two additional sub-panels mounted on OSB backing board in basement utility area. Evaluated electrical infrastructure, conduit routing, and available space to determine generator integration requirements and transfer switch placement for seamless backup power system installation.
Kevin T.
Kevin T. Checked in
Completed electrical estimate for Kohler generator installation requiring propane fuel source. Assessed existing dual-meter residential electrical service with Landis+Gyr and Milbank meters, documented current panel configuration including main distribution panel with multiple circuit breakers and two additional sub-panels mounted on OSB backing board in basement utility area. Evaluated electrical infrastructure, conduit routing, and available space to determine generator integration requirements and transfer switch placement for seamless backup power system installation.
Medina, OH 44256

 

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.