Schedule Service

Trusted HVAC, Electrical & Plumbing Services in Streetsboro, OH

When something goes wrong at home, you want help you can trust, and that’s where Blind & Sons comes in. Our HVAC technicians, plumbers, and electricians make home services easy in Streetsboro.

Don’t wait. Book your heating, cooling, plumbing, or electrical services now.

Your All-in-One Solution for Home Services in Streetsboro

At Blind & Sons, we offer decades of quality service, experience, and a strong reputation. We’ve built trust with our neighbors, and we’re glad to continue offering heating, cooling, plumbing, and electrical services to everyone who needs them.

What makes us different:

Need Services?

Complete HVAC Services for Streetsboro Homes

Technician checking the pressure of an AC unit

We’ll help you maintain your home’s comfort and safety with HVAC solutions you can trust. You’ll need repairs if you have no airflow or a fuel leak. You need a new system when your unit is over 10 years old and starts to lose efficiency. To get the most out of your HVAC unit, schedule yearly maintenance for each system

Heating & Furnace Services

Got heating problems? We’re here to help. Our technicians make sure you get the installation, repairs, and maintenance services your heater needs. Our heating services are simple, fast, and all you need to keep warm.

Trust Blind & Sons for:

Air Conditioning Services

Having trouble staying cool? We handle repairs, replacements, and maintenance for AC units. Our technicians work fast to keep your air conditioner running, so you can cool down without the stress of being hot and sweaty.

Count on us for:

Indoor Air Quality Solutions

Ensure you have clean air and balanced humidity in your home with air quality solutions from Blind & Sons. We offer:

Plumbing Services You Can Count On

Plumbing problems can be a real pain, but we’re here to help. From emergency plumbing repairs to water quality solutions, our team handles it all.

We also offer yearly maintenance to keep things running. Whether it’s a small drip or a burst pipe, we’ve got your back.

Our plumbing services include:

Water Heater Services for Hot Water You Can Rely On

Hot water not working like it should? We service standard and tankless water heaters to get things back to normal fast.

Whether it’s a small water heater repair, routine water heater maintenance, or a complete water heater replacement, our team will help you find the best solution so you can enjoy hot water again.

Trust Blind & Sons for all your water heater service needs!

Licensed Electricians for Safe, Reliable Power

Whole-home generator

Got an electrical issue or need some updates? We’ve got you covered with electrical troubleshooting, lighting installs, and wiring upgrades. We also protect your wiring and everything connected to your outlets with surge protection and much more.

Electrical services we offer include:

Generator Installation & Backup Power Solutions

Need backup power? We install whole-home generators from Generac to keep your home running during outages.

Our electricians offer:

Generator installation

Generator maintenance

Generator repair

Local Experts Serving Streetsboro Neighborhoods

Streetsboro is a special city filled with old charm and modernized homes. Because of this, we’ve built a team of professionals who can manage both.

Areas we serve around Streetsboro include:

  • Meadow View
  • Evergreen
  • Herrington Place
  • Sugarbush Knolls

Schedule HVAC, Plumbing, or Electrical Services in Streetsboro

Blind & Sons has all the home services you could need. Take a look at our Maintenance Value Plan. It offers discounts, loyalty rewards, and special service deals. Enjoy peace of mind with every benefit.

As a Lennox Premier Dealer, we can offer reputable products that are known to last. But don’t worry, we service all brands.

We’re BBB-accredited and even won the Angie’s List Super Service Award in 2016.

Contact us today and schedule an appointment for your Streetsboro home.

Frequently Asked Questions

What qualifies as an HVAC emergency?

No heat or cool air during extreme heat or cold outdoor temperatures.

How long do most water heaters last?

Traditional water heaters last eight to 12 years. Tankless water heaters last up to 20 years.

Do I need a permit to install a whole-home generator?

Yes, permits are required for whole-home generator installations.

 

Recent Jobs and Reviews in Streetsboro, OH

Streetsboro, OH at a glance

Blind and Sons has completed 20 jobs in Streetsboro, OH in April 2026.

The most recent job was on April 30, 2026.

Job Locations and Reviews

Streetsboro, OH - Replaced existing 80-gallon electric water heater with new 40-gallon Bradford White electric water heater with 6-year manufacturer warranty in basement utility area. Installation included new ball valve, thermal expansion tank mounted to ceiling joists, and all necessary copper piping and fittings to complete the connection. Two-person crew facilitated removal of old unit and proper installation of replacement equipment.
Isaiah H.
Isaiah H. Checked in
Replaced existing 80-gallon electric water heater with new 40-gallon Bradford White electric water heater with 6-year manufacturer warranty in basement utility area. Installation included new ball valve, thermal expansion tank mounted to ceiling joists, and all necessary copper piping and fittings to complete the connection. Two-person crew facilitated removal of old unit and proper installation of replacement equipment.
Streetsboro, OH 44241
Streetsboro, OH - Completed scheduled MVP heating maintenance visit. Performed comprehensive system inspection including examination of ventilation components, louvers, and air intake assemblies. All equipment found operating within normal parameters with louvers and ductwork in functional condition showing typical wear patterns consistent with regular use.
Kevin D.
Kevin D. Checked in
Completed scheduled MVP heating maintenance visit. Performed comprehensive system inspection including examination of ventilation components, louvers, and air intake assemblies. All equipment found operating within normal parameters with louvers and ductwork in functional condition showing typical wear patterns consistent with regular use.
Streetsboro, OH 44241
Completed scheduled preventive maintenance on 10-year-old Trane HVAC system for MVP customer. Performed comprehensive inspection of furnace, air handler, and associated electrical controls, verifying all components operational and connections secure. Documented system condition with photos showing proper installation of PVC ventilation lines and control board wiring configuration.
Completed scheduled preventive maintenance on 10-year-old Trane HVAC system for MVP customer. Performed comprehensive inspection of furnace, air handler, and associated electrical controls, verifying all components operational and connections secure. Documented system condition with photos showing proper installation of PVC ventilation lines and control board wiring configuration.
Derrick M.
Derrick M. Checked in
Completed scheduled preventive maintenance on 10-year-old Trane HVAC system for MVP customer. Performed comprehensive inspection of furnace, air handler, and associated electrical controls, verifying all components operational and connections secure. Documented system condition with photos showing proper installation of PVC ventilation lines and control board wiring configuration.
Streetsboro, OH 44241
Completed comprehensive AC tune-up on aging Trane 13 SEER outdoor condensing unit (Model 4TTR3030G1000AA) showing significant weathering and over 15 years of service. Performed standard maintenance protocol including inspection of electrical components, fan motor operation, refrigerant levels, and overall system functionality to ensure continued reliable cooling performance.
Completed comprehensive AC tune-up on aging Trane 13 SEER outdoor condensing unit (Model 4TTR3030G1000AA) showing significant weathering and over 15 years of service. Performed standard maintenance protocol including inspection of electrical components, fan motor operation, refrigerant levels, and overall system functionality to ensure continued reliable cooling performance.
Daniel
Daniel Checked in
Completed comprehensive AC tune-up on aging Trane 13 SEER outdoor condensing unit (Model 4TTR3030G1000AA) showing significant weathering and over 15 years of service. Performed standard maintenance protocol including inspection of electrical components, fan motor operation, refrigerant levels, and overall system functionality to ensure continued reliable cooling performance.
Streetsboro, OH 44241
Completed comprehensive tune-up service on HVAC system, arriving after 2:30 PM as requested. Performed thorough inspection of air handler components including blower motor assembly, control board with electrical connections, and heat exchanger, verifying all wiring connections were secure and system components were operating within normal parameters. Replaced 16x24x1 air filter and documented equipment condition with photos for service records.
Completed comprehensive tune-up service on HVAC system, arriving after 2:30 PM as requested. Performed thorough inspection of air handler components including blower motor assembly, control board with electrical connections, and heat exchanger, verifying all wiring connections were secure and system components were operating within normal parameters. Replaced 16x24x1 air filter and documented equipment condition with photos for service records.
Daniel
Daniel Checked in
Completed comprehensive tune-up service on HVAC system, arriving after 2:30 PM as requested. Performed thorough inspection of air handler components including blower motor assembly, control board with electrical connections, and heat exchanger, verifying all wiring connections were secure and system components were operating within normal parameters. Replaced 16x24x1 air filter and documented equipment condition with photos for service records.
Streetsboro, OH 44241
Completed full HVAC system installation including new 80% efficiency furnace and air conditioning condenser unit. Installed two outdoor condensing units with proper refrigerant line sets, electrical disconnects with 20A fuses, and established all necessary power connections to exterior electrical service panel. All equipment mounted on prepared pad with proper clearances, refrigerant lines properly insulated and secured to building exterior, and system tested for proper operation upon completion.
Completed full HVAC system installation including new 80% efficiency furnace and air conditioning condenser unit. Installed two outdoor condensing units with proper refrigerant line sets, electrical disconnects with 20A fuses, and established all necessary power connections to exterior electrical service panel. All equipment mounted on prepared pad with proper clearances, refrigerant lines properly insulated and secured to building exterior, and system tested for proper operation upon completion.
Trent B.
Trent B. Checked in
Completed full HVAC system installation including new 80% efficiency furnace and air conditioning condenser unit. Installed two outdoor condensing units with proper refrigerant line sets, electrical disconnects with 20A fuses, and established all necessary power connections to exterior electrical service panel. All equipment mounted on prepared pad with proper clearances, refrigerant lines properly insulated and secured to building exterior, and system tested for proper operation upon completion.
Streetsboro, OH 44241
Responded to no water complaint in kitchen. Upon arrival, inspected kitchen faucet and verified lack of water flow at fixture. Traced supply lines to basement utility area and located water heater with associated plumbing connections. Assessed water distribution system including supply valves and piping connections. Documented existing conditions of kitchen sink fixture, supply lines, and basement mechanical equipment for service records.
Responded to no water complaint in kitchen. Upon arrival, inspected kitchen faucet and verified lack of water flow at fixture. Traced supply lines to basement utility area and located water heater with associated plumbing connections. Assessed water distribution system including supply valves and piping connections. Documented existing conditions of kitchen sink fixture, supply lines, and basement mechanical equipment for service records.
Mark W.
Mark W. Checked in
Responded to no water complaint in kitchen. Upon arrival, inspected kitchen faucet and verified lack of water flow at fixture. Traced supply lines to basement utility area and located water heater with associated plumbing connections. Assessed water distribution system including supply valves and piping connections. Documented existing conditions of kitchen sink fixture, supply lines, and basement mechanical equipment for service records.
Streetsboro, OH 44241
Responded to water leak complaint on 2-year-old natural gas furnace where water was observed discharging from the exhaust pipe. Upon inspection, identified condensate drainage issue affecting the PVC vent piping system. Examined the condensate drain line configuration in the ceiling cavity and verified proper installation of drain components and connections. Addressed drainage concern to prevent water discharge through the exhaust termination. System operational upon completion, with condensate properly routed through designated drain lines.
Responded to water leak complaint on 2-year-old natural gas furnace where water was observed discharging from the exhaust pipe. Upon inspection, identified condensate drainage issue affecting the PVC vent piping system. Examined the condensate drain line configuration in the ceiling cavity and verified proper installation of drain components and connections. Addressed drainage concern to prevent water discharge through the exhaust termination. System operational upon completion, with condensate properly routed through designated drain lines.
Hershel M.
Hershel M. Checked in
Responded to water leak complaint on 2-year-old natural gas furnace where water was observed discharging from the exhaust pipe. Upon inspection, identified condensate drainage issue affecting the PVC vent piping system. Examined the condensate drain line configuration in the ceiling cavity and verified proper installation of drain components and connections. Addressed drainage concern to prevent water discharge through the exhaust termination. System operational upon completion, with condensate properly routed through designated drain lines.
Streetsboro, OH 44241
Streetsboro, OH - Responded to service call for faucet installation in laundry room off garage. Customer had shut off the supply valve underneath due to light dripping from the existing fixture. Successfully installed new chrome dual-handle faucet assembly with central spout on white porcelain sink, ensuring proper connections to supply lines and confirming no leaks upon completion.
Travis B.
Travis B. Checked in
Responded to service call for faucet installation in laundry room off garage. Customer had shut off the supply valve underneath due to light dripping from the existing fixture. Successfully installed new chrome dual-handle faucet assembly with central spout on white porcelain sink, ensuring proper connections to supply lines and confirming no leaks upon completion.
Streetsboro, OH 44241
Completed preventive maintenance on residential air conditioning system. Inspected electrical connections at outdoor condensing unit, verified proper wire routing and terminations, and documented equipment condition. All electrical components found secure with no immediate safety concerns noted, though unit exterior shows normal weathering from environmental exposure.
Completed preventive maintenance on residential air conditioning system. Inspected electrical connections at outdoor condensing unit, verified proper wire routing and terminations, and documented equipment condition. All electrical components found secure with no immediate safety concerns noted, though unit exterior shows normal weathering from environmental exposure.
Hershel M.
Hershel M. Checked in
Completed preventive maintenance on residential air conditioning system. Inspected electrical connections at outdoor condensing unit, verified proper wire routing and terminations, and documented equipment condition. All electrical components found secure with no immediate safety concerns noted, though unit exterior shows normal weathering from environmental exposure.
Streetsboro, OH 44241
Conducted comprehensive assessment of 28-year-old furnace and air conditioning system at owner-occupied residence for complete replacement estimate. Evaluated existing Carrier furnace installation, inspected condensate drainage lines, venting configuration, and electrical connections in basement utility area. Documented current system condition including aged refrigerant lines showing corrosion, existing ductwork connections, and overall equipment layout to provide accurate replacement specifications and installation requirements.
Conducted comprehensive assessment of 28-year-old furnace and air conditioning system at owner-occupied residence for complete replacement estimate. Evaluated existing Carrier furnace installation, inspected condensate drainage lines, venting configuration, and electrical connections in basement utility area. Documented current system condition including aged refrigerant lines showing corrosion, existing ductwork connections, and overall equipment layout to provide accurate replacement specifications and installation requirements.
Jordan K.
Jordan K. Checked in
Conducted comprehensive assessment of 28-year-old furnace and air conditioning system at owner-occupied residence for complete replacement estimate. Evaluated existing Carrier furnace installation, inspected condensate drainage lines, venting configuration, and electrical connections in basement utility area. Documented current system condition including aged refrigerant lines showing corrosion, existing ductwork connections, and overall equipment layout to provide accurate replacement specifications and installation requirements.
Streetsboro, OH 44241
Responded to service call for furnace emitting burning odor with visible damaged component. Upon inspection, accessed unit interior and identified compromised electrical component on control board. Documented existing wiring configuration and component condition with photographs showing extensive wire harness network, control board connections, and internal mechanical assembly including blower motor housing and PVC condensate piping. Given household occupant's medical sensitivity to temperature fluctuations, prioritized rapid assessment and provided recommendations for component replacement to restore safe heating system operation.
Responded to service call for furnace emitting burning odor with visible damaged component. Upon inspection, accessed unit interior and identified compromised electrical component on control board. Documented existing wiring configuration and component condition with photographs showing extensive wire harness network, control board connections, and internal mechanical assembly including blower motor housing and PVC condensate piping. Given household occupant's medical sensitivity to temperature fluctuations, prioritized rapid assessment and provided recommendations for component replacement to restore safe heating system operation.
Hershel M.
Hershel M. Checked in
Responded to service call for furnace emitting burning odor with visible damaged component. Upon inspection, accessed unit interior and identified compromised electrical component on control board. Documented existing wiring configuration and component condition with photographs showing extensive wire harness network, control board connections, and internal mechanical assembly including blower motor housing and PVC condensate piping. Given household occupant's medical sensitivity to temperature fluctuations, prioritized rapid assessment and provided recommendations for component replacement to restore safe heating system operation.
Streetsboro, OH 44241
Completed full HVAC system installation including an 80% efficiency furnace and air conditioning unit for an 858 square foot residential property. The AC condenser was positioned at the rear of the home per the site plan, with the furnace installed in the basement mechanical room alongside existing water heating equipment. New flexible ductwork was installed and connected to the furnace with proper insulation, and all gas connections were secured with appropriate shut-off valves for safety compliance.
Completed full HVAC system installation including an 80% efficiency furnace and air conditioning unit for an 858 square foot residential property. The AC condenser was positioned at the rear of the home per the site plan, with the furnace installed in the basement mechanical room alongside existing water heating equipment. New flexible ductwork was installed and connected to the furnace with proper insulation, and all gas connections were secured with appropriate shut-off valves for safety compliance.
Jay E.
Jay E. Checked in
Completed full HVAC system installation including an 80% efficiency furnace and air conditioning unit for an 858 square foot residential property. The AC condenser was positioned at the rear of the home per the site plan, with the furnace installed in the basement mechanical room alongside existing water heating equipment. New flexible ductwork was installed and connected to the furnace with proper insulation, and all gas connections were secured with appropriate shut-off valves for safety compliance.
Streetsboro, OH 44241
Responded to electrical outage affecting approximately two-thirds of modular home that had been vacant for three and a half months. Upon arrival, conducted comprehensive evaluation of electrical system to identify cause of power loss suspected to be related to rodent damage from mouse infestation.

Performed thorough inspection of main electrical panel and discovered extensive corrosion and water damage throughout the enclosure. Panel exhibited significant rust accumulation on bottom surfaces and lower portions, with corrosion extending to terminal connections and internal components. Found degraded and discolored wiring with compromised insulation showing signs of aging and environmental exposure. Observed disorganized and tangled wiring in lower section of panel with accumulated debris and particulate matter.

Documented conditions with photographs showing corroded bussing connections, deteriorated circuit breakers, and moisture-damaged electrical components. Panel condition indicate
Responded to electrical outage affecting approximately two-thirds of modular home that had been vacant for three and a half months. Upon arrival, conducted comprehensive evaluation of electrical system to identify cause of power loss suspected to be related to rodent damage from mouse infestation.

Performed thorough inspection of main electrical panel and discovered extensive corrosion and water damage throughout the enclosure. Panel exhibited significant rust accumulation on bottom surfaces and lower portions, with corrosion extending to terminal connections and internal components. Found degraded and discolored wiring with compromised insulation showing signs of aging and environmental exposure. Observed disorganized and tangled wiring in lower section of panel with accumulated debris and particulate matter.

Documented conditions with photographs showing corroded bussing connections, deteriorated circuit breakers, and moisture-damaged electrical components. Panel condition indicate
Steven M.
Steven M. Checked in
Responded to electrical outage affecting approximately two-thirds of modular home that had been vacant for three and a half months. Upon arrival, conducted comprehensive evaluation of electrical system to identify cause of power loss suspected to be related to rodent damage from mouse infestation. Performed thorough inspection of main electrical panel and discovered extensive corrosion and water damage throughout the enclosure. Panel exhibited significant rust accumulation on bottom surfaces and lower portions, with corrosion extending to terminal connections and internal components. Found degraded and discolored wiring with compromised insulation showing signs of aging and environmental exposure. Observed disorganized and tangled wiring in lower section of panel with accumulated debris and particulate matter. Documented conditions with photographs showing corroded bussing connections, deteriorated circuit breakers, and moisture-damaged electrical components. Panel condition indicate
Streetsboro, OH 44241
Streetsboro, OH - Returned to property to install replacement thermostat on furnace unit that was previously installed approximately two weeks prior. Successfully mounted and wired new Honeywell digital thermostat to wall, verified proper communication with heating system, and confirmed operational functionality.
Shae M.
Shae M. Checked in
Returned to property to install replacement thermostat on furnace unit that was previously installed approximately two weeks prior. Successfully mounted and wired new Honeywell digital thermostat to wall, verified proper communication with heating system, and confirmed operational functionality.
Streetsboro, OH 44241
Performed routine preventive maintenance on residential standby generator system. Conducted comprehensive inspection of unit including visual assessment of gas meter connections, supply piping, and associated fittings which showed signs of corrosion on copper components. Verified generator control panel operation with all indicator lights functioning properly and confirmed unit powers on successfully. Documented existing condition of gas supply infrastructure and generator equipment with photographic records for service history.
Performed routine preventive maintenance on residential standby generator system. Conducted comprehensive inspection of unit including visual assessment of gas meter connections, supply piping, and associated fittings which showed signs of corrosion on copper components. Verified generator control panel operation with all indicator lights functioning properly and confirmed unit powers on successfully. Documented existing condition of gas supply infrastructure and generator equipment with photographic records for service history.
Steven M.
Steven M. Checked in
Performed routine preventive maintenance on residential standby generator system. Conducted comprehensive inspection of unit including visual assessment of gas meter connections, supply piping, and associated fittings which showed signs of corrosion on copper components. Verified generator control panel operation with all indicator lights functioning properly and confirmed unit powers on successfully. Documented existing condition of gas supply infrastructure and generator equipment with photographic records for service history.
Streetsboro, OH 44241
Completed installation of new air conditioning system and humidifier at residential property. Installed outdoor condenser unit on prepared mulch bed with proper clearances, ran refrigerant lines and electrical conduit to disconnect box mounted on exterior wall, and installed condensate drain line. System was evacuated to proper micron level as verified by vacuum gauge reading, pressure tested, and commissioned for operation.
Completed installation of new air conditioning system and humidifier at residential property. Installed outdoor condenser unit on prepared mulch bed with proper clearances, ran refrigerant lines and electrical conduit to disconnect box mounted on exterior wall, and installed condensate drain line. System was evacuated to proper micron level as verified by vacuum gauge reading, pressure tested, and commissioned for operation.
Austin B.
Austin B. Checked in
Completed installation of new air conditioning system and humidifier at residential property. Installed outdoor condenser unit on prepared mulch bed with proper clearances, ran refrigerant lines and electrical conduit to disconnect box mounted on exterior wall, and installed condensate drain line. System was evacuated to proper micron level as verified by vacuum gauge reading, pressure tested, and commissioned for operation.
Streetsboro, OH 44241
Streetsboro, OH - Responded to service call for a leaking Rheem Performance 40-gallon gas water heater (Serial # A421906493). Upon inspection, confirmed active leak at base of unit with visible water staining on concrete floor. Evaluated unit per previous diagnosis from another contractor indicating failed gas control valve and pilot assembly. Assessed overall condition of water heater and documented existing plumbing connections including copper supply lines, flexible connectors, and temperature/pressure relief valve. Provided technical evaluation and repair recommendations to customer.
James P.
James P. Checked in
Responded to service call for a leaking Rheem Performance 40-gallon gas water heater (Serial # A421906493). Upon inspection, confirmed active leak at base of unit with visible water staining on concrete floor. Evaluated unit per previous diagnosis from another contractor indicating failed gas control valve and pilot assembly. Assessed overall condition of water heater and documented existing plumbing connections including copper supply lines, flexible connectors, and temperature/pressure relief valve. Provided technical evaluation and repair recommendations to customer.
Streetsboro, OH 44241
Streetsboro, OH - Completed scheduled maintenance flush on tankless water heater unit mounted in basement utility area. Performed descaling procedure by isolating unit with service valves, circulating cleaning solution through heat exchanger to remove mineral buildup, and flushing system thoroughly to restore optimal performance and efficiency.
Travis B.
Travis B. Checked in
Completed scheduled maintenance flush on tankless water heater unit mounted in basement utility area. Performed descaling procedure by isolating unit with service valves, circulating cleaning solution through heat exchanger to remove mineral buildup, and flushing system thoroughly to restore optimal performance and efficiency.
Streetsboro, OH 44241
Streetsboro, OH - Completed comprehensive AC tune-up including system inspection and performance verification. Inspected and documented electrical components, including 30-amp FLNR fuses in holder, confirming proper amperage rating and fuse integrity for system protection. All components found operating within normal parameters with no immediate service needs identified.
Colton D.
Colton D. Checked in
Completed comprehensive AC tune-up including system inspection and performance verification. Inspected and documented electrical components, including 30-amp FLNR fuses in holder, confirming proper amperage rating and fuse integrity for system protection. All components found operating within normal parameters with no immediate service needs identified.
Streetsboro, OH 44241

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image