Schedule Service

Trusted HVAC, Electrical & Plumbing Services in Streetsboro, OH

When something goes wrong at home, you want help you can trust, and that’s where Blind & Sons comes in. Our HVAC technicians, plumbers, and electricians make home services easy in Streetsboro.

Don’t wait. Book your heating, cooling, plumbing, or electrical services now.

Your All-in-One Solution for Home Services in Streetsboro

At Blind & Sons, we offer decades of quality service, experience, and a strong reputation. We’ve built trust with our neighbors, and we’re glad to continue offering heating, cooling, plumbing, and electrical services to everyone who needs them.

What makes us different:

Need Services?

Complete HVAC Services for Streetsboro Homes

Technician checking the pressure of an AC unit

We’ll help you maintain your home’s comfort and safety with HVAC solutions you can trust. You’ll need repairs if you have no airflow or a fuel leak. You need a new system when your unit is over 10 years old and starts to lose efficiency. To get the most out of your HVAC unit, schedule yearly maintenance for each system

Heating & Furnace Services

Got heating problems? We’re here to help. Our technicians make sure you get the installation, repairs, and maintenance services your heater needs. Our heating services are simple, fast, and all you need to keep warm.

Trust Blind & Sons for:

Air Conditioning Services

Having trouble staying cool? We handle repairs, replacements, and maintenance for AC units. Our technicians work fast to keep your air conditioner running, so you can cool down without the stress of being hot and sweaty.

Count on us for:

Indoor Air Quality Solutions

Ensure you have clean air and balanced humidity in your home with air quality solutions from Blind & Sons. We offer:

Plumbing Services You Can Count On

Plumbing problems can be a real pain, but we’re here to help. From emergency plumbing repairs to water quality solutions, our team handles it all.

We also offer yearly maintenance to keep things running. Whether it’s a small drip or a burst pipe, we’ve got your back.

Our plumbing services include:

Water Heater Services for Hot Water You Can Rely On

Hot water not working like it should? We service standard and tankless water heaters to get things back to normal fast.

Whether it’s a small water heater repair, routine water heater maintenance, or a complete water heater replacement, our team will help you find the best solution so you can enjoy hot water again.

Trust Blind & Sons for all your water heater service needs!

Licensed Electricians for Safe, Reliable Power

Whole-home generator

Got an electrical issue or need some updates? We’ve got you covered with electrical troubleshooting, lighting installs, and wiring upgrades. We also protect your wiring and everything connected to your outlets with surge protection and much more.

Electrical services we offer include:

Generator Installation & Backup Power Solutions

Need backup power? We install whole-home generators from Generac to keep your home running during outages.

Our electricians offer:

Generator installation

Generator maintenance

Generator repair

Local Experts Serving Streetsboro Neighborhoods

Streetsboro is a special city filled with old charm and modernized homes. Because of this, we’ve built a team of professionals who can manage both.

Areas we serve around Streetsboro include:

  • Meadow View
  • Evergreen
  • Herrington Place
  • Sugarbush Knolls

Schedule HVAC, Plumbing, or Electrical Services in Streetsboro

Blind & Sons has all the home services you could need. Take a look at our Maintenance Value Plan. It offers discounts, loyalty rewards, and special service deals. Enjoy peace of mind with every benefit.

As a Lennox Premier Dealer, we can offer reputable products that are known to last. But don’t worry, we service all brands.

We’re BBB-accredited and even won the Angie’s List Super Service Award in 2016.

Contact us today and schedule an appointment for your Streetsboro home.

Frequently Asked Questions

What qualifies as an HVAC emergency?

No heat or cool air during extreme heat or cold outdoor temperatures.

How long do most water heaters last?

Traditional water heaters last eight to 12 years. Tankless water heaters last up to 20 years.

Do I need a permit to install a whole-home generator?

Yes, permits are required for whole-home generator installations.

 

Recent Jobs and Reviews in Streetsboro, OH

Streetsboro, OH at a glance

Blind and Sons has completed 20 jobs in Streetsboro, OH between May 2026 and June 2026.

The most recent job was on June 5, 2026.

Job Locations and Reviews

Completed MVP cooling maintenance visit on 7-year-old residential HVAC system. Inspected Lennox air handler unit in basement, verifying proper operation of all components, condensate drain lines, and refrigerant connections. Examined outdoor condenser unit, confirmed adequate clearance, checked condition of coil fins, and verified proper airflow. System operating within normal parameters with no issues identified during routine preventive maintenance inspection.
Completed MVP cooling maintenance visit on 7-year-old residential HVAC system. Inspected Lennox air handler unit in basement, verifying proper operation of all components, condensate drain lines, and refrigerant connections. Examined outdoor condenser unit, confirmed adequate clearance, checked condition of coil fins, and verified proper airflow. System operating within normal parameters with no issues identified during routine preventive maintenance inspection.
John W.
John W. Checked in
Completed MVP cooling maintenance visit on 7-year-old residential HVAC system. Inspected Lennox air handler unit in basement, verifying proper operation of all components, condensate drain lines, and refrigerant connections. Examined outdoor condenser unit, confirmed adequate clearance, checked condition of coil fins, and verified proper airflow. System operating within normal parameters with no issues identified during routine preventive maintenance inspection.
Streetsboro, OH 44241
Completed annual air conditioning maintenance on 3-year-old Lennox condensing unit under MVP plan. Performed comprehensive system inspection including electrical connections, capacitor testing, and visual assessment of all components. Unit operating within normal parameters with no deficiencies noted.
Completed annual air conditioning maintenance on 3-year-old Lennox condensing unit under MVP plan. Performed comprehensive system inspection including electrical connections, capacitor testing, and visual assessment of all components. Unit operating within normal parameters with no deficiencies noted.
Taylor F.
Taylor F. Checked in
Completed annual air conditioning maintenance on 3-year-old Lennox condensing unit under MVP plan. Performed comprehensive system inspection including electrical connections, capacitor testing, and visual assessment of all components. Unit operating within normal parameters with no deficiencies noted.
Streetsboro, OH 44241
Responded to emergency call for severely leaking outdoor water spigot. Upon arrival, accessed basement area to locate and assess the damaged fixture and associated plumbing connections. The outdoor spigot had failed, causing significant water leakage that required immediate attention to prevent further water damage and waste.

Inspected the existing plumbing infrastructure in the unfinished basement area, identifying the blue PEX water supply lines and connections serving the exterior spigot. Evaluated the ceiling-mounted piping system, including the PEX lines with metal fittings and copper piping components running through the floor joists. Documented the condition of the installation area, noting the exposed wooden joists, insulation, and concrete block foundation walls for reference.

Shut off water supply to the affected line to stop the leak. Removed the damaged outdoor water spigot assembly and assessed the connection point for any additional damage or deterioration. Prepared the
Responded to emergency call for severely leaking outdoor water spigot. Upon arrival, accessed basement area to locate and assess the damaged fixture and associated plumbing connections. The outdoor spigot had failed, causing significant water leakage that required immediate attention to prevent further water damage and waste.

Inspected the existing plumbing infrastructure in the unfinished basement area, identifying the blue PEX water supply lines and connections serving the exterior spigot. Evaluated the ceiling-mounted piping system, including the PEX lines with metal fittings and copper piping components running through the floor joists. Documented the condition of the installation area, noting the exposed wooden joists, insulation, and concrete block foundation walls for reference.

Shut off water supply to the affected line to stop the leak. Removed the damaged outdoor water spigot assembly and assessed the connection point for any additional damage or deterioration. Prepared the
Isaiah H.
Isaiah H. Checked in
Responded to emergency call for severely leaking outdoor water spigot. Upon arrival, accessed basement area to locate and assess the damaged fixture and associated plumbing connections. The outdoor spigot had failed, causing significant water leakage that required immediate attention to prevent further water damage and waste. Inspected the existing plumbing infrastructure in the unfinished basement area, identifying the blue PEX water supply lines and connections serving the exterior spigot. Evaluated the ceiling-mounted piping system, including the PEX lines with metal fittings and copper piping components running through the floor joists. Documented the condition of the installation area, noting the exposed wooden joists, insulation, and concrete block foundation walls for reference. Shut off water supply to the affected line to stop the leak. Removed the damaged outdoor water spigot assembly and assessed the connection point for any additional damage or deterioration. Prepared the
Streetsboro, OH 44241
Responded to service call for multiple plumbing leaks in residential property. Addressed leaking plastic piping at kitchen sink and repaired wall line requiring seal in basement bathroom. Inspected plumbing fixtures including shutoff valves, PVC connections, and pipe mounting hardware to ensure proper function and prevent future water damage.
Responded to service call for multiple plumbing leaks in residential property. Addressed leaking plastic piping at kitchen sink and repaired wall line requiring seal in basement bathroom. Inspected plumbing fixtures including shutoff valves, PVC connections, and pipe mounting hardware to ensure proper function and prevent future water damage.
Nick L.
Nick L. Checked in
Responded to service call for multiple plumbing leaks in residential property. Addressed leaking plastic piping at kitchen sink and repaired wall line requiring seal in basement bathroom. Inspected plumbing fixtures including shutoff valves, PVC connections, and pipe mounting hardware to ensure proper function and prevent future water damage.
Streetsboro, OH 44241
Returned to property to perform refrigerant leak search on Airtemp outdoor condensing unit as previously requested. Utilized electronic leak detector to systematically check all refrigerant connections, coil sections, and service ports. Testing equipment registered reading of 22.2 during diagnostic process, confirming presence of refrigerant leak requiring repair.
Returned to property to perform refrigerant leak search on Airtemp outdoor condensing unit as previously requested. Utilized electronic leak detector to systematically check all refrigerant connections, coil sections, and service ports. Testing equipment registered reading of 22.2 during diagnostic process, confirming presence of refrigerant leak requiring repair.
Stephanie E.
Stephanie E. Checked in
Returned to property to perform refrigerant leak search on Airtemp outdoor condensing unit as previously requested. Utilized electronic leak detector to systematically check all refrigerant connections, coil sections, and service ports. Testing equipment registered reading of 22.2 during diagnostic process, confirming presence of refrigerant leak requiring repair.
Streetsboro, OH 44241
Completed MVP cooling maintenance visit on 8-year-old air conditioning system. Performed standard preventive maintenance procedures including inspection of capacitor, electrical connections, and service disconnect. System operating within normal parameters with all components functioning properly.
Completed MVP cooling maintenance visit on 8-year-old air conditioning system. Performed standard preventive maintenance procedures including inspection of capacitor, electrical connections, and service disconnect. System operating within normal parameters with all components functioning properly.
Jesus M.
Jesus M. Checked in
Completed MVP cooling maintenance visit on 8-year-old air conditioning system. Performed standard preventive maintenance procedures including inspection of capacitor, electrical connections, and service disconnect. System operating within normal parameters with all components functioning properly.
Streetsboro, OH 44241
Responded to report of circuit breaker tripping when equipment was plugged into outlets throughout the residence. Upon investigation, identified an 80V electric riding lawn mower being charged via a power strip in the garage as the source of the electrical overload. The power strip was inadequate for the high amperage draw required by the mower's battery charging system, causing repeated breaker trips that affected multiple circuits. Advised customer on proper charging procedures using a dedicated outlet and circuit appropriate for the equipment's electrical requirements. Inspected and provided estimate for replacement of a GFCI outlet as requested. Verified electrical system functionality after disconnecting the overloading equipment and confirmed no damage to existing circuits or breaker panel.
Responded to report of circuit breaker tripping when equipment was plugged into outlets throughout the residence. Upon investigation, identified an 80V electric riding lawn mower being charged via a power strip in the garage as the source of the electrical overload. The power strip was inadequate for the high amperage draw required by the mower's battery charging system, causing repeated breaker trips that affected multiple circuits. Advised customer on proper charging procedures using a dedicated outlet and circuit appropriate for the equipment's electrical requirements. Inspected and provided estimate for replacement of a GFCI outlet as requested. Verified electrical system functionality after disconnecting the overloading equipment and confirmed no damage to existing circuits or breaker panel.
Bradley L.
Bradley L. Checked in
Responded to report of circuit breaker tripping when equipment was plugged into outlets throughout the residence. Upon investigation, identified an 80V electric riding lawn mower being charged via a power strip in the garage as the source of the electrical overload. The power strip was inadequate for the high amperage draw required by the mower's battery charging system, causing repeated breaker trips that affected multiple circuits. Advised customer on proper charging procedures using a dedicated outlet and circuit appropriate for the equipment's electrical requirements. Inspected and provided estimate for replacement of a GFCI outlet as requested. Verified electrical system functionality after disconnecting the overloading equipment and confirmed no damage to existing circuits or breaker panel.
Streetsboro, OH 44241
Completed flush and fill maintenance procedure on HydroJet residential tanked water heater. Drained sediment buildup from tank bottom, flushed system with fresh water supply, and refilled unit to restore optimal operating efficiency and extend equipment lifespan.
Completed flush and fill maintenance procedure on HydroJet residential tanked water heater. Drained sediment buildup from tank bottom, flushed system with fresh water supply, and refilled unit to restore optimal operating efficiency and extend equipment lifespan.
Travis B.
Travis B. Checked in
Completed flush and fill maintenance procedure on HydroJet residential tanked water heater. Drained sediment buildup from tank bottom, flushed system with fresh water supply, and refilled unit to restore optimal operating efficiency and extend equipment lifespan.
Streetsboro, OH 44241
Performed routine cooling maintenance on HVAC system. Accessed air handler compartment and conducted diagnostic testing using calibrated digital measurement instrument. Inspected interior components for proper operation, noting normal dust accumulation consistent with regular system use. All measurements recorded within acceptable parameters and unit confirmed operational.
Performed routine cooling maintenance on HVAC system. Accessed air handler compartment and conducted diagnostic testing using calibrated digital measurement instrument. Inspected interior components for proper operation, noting normal dust accumulation consistent with regular system use. All measurements recorded within acceptable parameters and unit confirmed operational.
Colton D.
Colton D. Checked in
Performed routine cooling maintenance on HVAC system. Accessed air handler compartment and conducted diagnostic testing using calibrated digital measurement instrument. Inspected interior components for proper operation, noting normal dust accumulation consistent with regular system use. All measurements recorded within acceptable parameters and unit confirmed operational.
Streetsboro, OH 44241
# HVAC Maintenance - Cooling

Performed comprehensive preventive maintenance service on an 8-year-old residential air conditioning system. Inspected outdoor condensing unit and electrical panel, verifying proper wiring connections and control circuit functionality. Accessed indoor air handler unit and replaced heavily soiled air filter that had accumulated significant dust and debris, which was restricting airflow and reducing system efficiency. All components inspected and found to be operating within normal parameters following filter replacement and routine maintenance procedures.
# HVAC Maintenance - Cooling

Performed comprehensive preventive maintenance service on an 8-year-old residential air conditioning system. Inspected outdoor condensing unit and electrical panel, verifying proper wiring connections and control circuit functionality. Accessed indoor air handler unit and replaced heavily soiled air filter that had accumulated significant dust and debris, which was restricting airflow and reducing system efficiency. All components inspected and found to be operating within normal parameters following filter replacement and routine maintenance procedures.
Colton D.
Colton D. Checked in
# HVAC Maintenance - Cooling Performed comprehensive preventive maintenance service on an 8-year-old residential air conditioning system. Inspected outdoor condensing unit and electrical panel, verifying proper wiring connections and control circuit functionality. Accessed indoor air handler unit and replaced heavily soiled air filter that had accumulated significant dust and debris, which was restricting airflow and reducing system efficiency. All components inspected and found to be operating within normal parameters following filter replacement and routine maintenance procedures.
Streetsboro, OH 44241
Completed scheduled air conditioning maintenance visit. Performed comprehensive system inspection including visual examination of mechanical components, condensate drainage system, and ductwork. Measured and recorded system operating parameters using digital testing equipment, with supply air temperature reading at 50°F indicating proper cooling performance. All components found operating within normal specifications.
Completed scheduled air conditioning maintenance visit. Performed comprehensive system inspection including visual examination of mechanical components, condensate drainage system, and ductwork. Measured and recorded system operating parameters using digital testing equipment, with supply air temperature reading at 50°F indicating proper cooling performance. All components found operating within normal specifications.
Colton D.
Colton D. Checked in
Completed scheduled air conditioning maintenance visit. Performed comprehensive system inspection including visual examination of mechanical components, condensate drainage system, and ductwork. Measured and recorded system operating parameters using digital testing equipment, with supply air temperature reading at 50°F indicating proper cooling performance. All components found operating within normal specifications.
Streetsboro, OH 44241
Diagnosed exhaust venting issue causing water to discharge in large quantities from furnace exhaust. Upon inspection, discovered that previous third-party rerouting of exhaust piping (performed to accommodate hot tub installation) created a 10-foot trap section with improper pitch, resulting in significant water accumulation. Determined that existing exhaust configuration violated proper venting standards and required correction. Identified that power vent water heater exhaust has identical improper pitch condition and will likely experience similar issues. Proposed two corrective solutions: reroute exhaust piping back to original configuration near hot tub location, or lower exhaust termination through finished basement wall into furnace room to achieve proper pitch and drainage. Customer approved repair work to be scheduled and completed by installation crew to ensure compliant venting system operation.
Diagnosed exhaust venting issue causing water to discharge in large quantities from furnace exhaust. Upon inspection, discovered that previous third-party rerouting of exhaust piping (performed to accommodate hot tub installation) created a 10-foot trap section with improper pitch, resulting in significant water accumulation. Determined that existing exhaust configuration violated proper venting standards and required correction. Identified that power vent water heater exhaust has identical improper pitch condition and will likely experience similar issues. Proposed two corrective solutions: reroute exhaust piping back to original configuration near hot tub location, or lower exhaust termination through finished basement wall into furnace room to achieve proper pitch and drainage. Customer approved repair work to be scheduled and completed by installation crew to ensure compliant venting system operation.
Ethan F.
Ethan F. Checked in
Diagnosed exhaust venting issue causing water to discharge in large quantities from furnace exhaust. Upon inspection, discovered that previous third-party rerouting of exhaust piping (performed to accommodate hot tub installation) created a 10-foot trap section with improper pitch, resulting in significant water accumulation. Determined that existing exhaust configuration violated proper venting standards and required correction. Identified that power vent water heater exhaust has identical improper pitch condition and will likely experience similar issues. Proposed two corrective solutions: reroute exhaust piping back to original configuration near hot tub location, or lower exhaust termination through finished basement wall into furnace room to achieve proper pitch and drainage. Customer approved repair work to be scheduled and completed by installation crew to ensure compliant venting system operation.
Streetsboro, OH 44241
Responded to service call for air conditioning system blowing warm air with thermostat lockout issues. Inspected condensing unit and confirmed compressor operation but system failing to produce cooling. Examined refrigerant lines and evaporator coil assembly within air handler, noting proper line insulation and drain line installation. Based on visual inspection of copper refrigerant lines showing discoloration patterns and system symptoms, diagnosed potential refrigerant charge issue or restriction in refrigerant circuit preventing proper heat transfer and cooling performance.
Responded to service call for air conditioning system blowing warm air with thermostat lockout issues. Inspected condensing unit and confirmed compressor operation but system failing to produce cooling. Examined refrigerant lines and evaporator coil assembly within air handler, noting proper line insulation and drain line installation. Based on visual inspection of copper refrigerant lines showing discoloration patterns and system symptoms, diagnosed potential refrigerant charge issue or restriction in refrigerant circuit preventing proper heat transfer and cooling performance.
Colton D.
Colton D. Checked in
Responded to service call for air conditioning system blowing warm air with thermostat lockout issues. Inspected condensing unit and confirmed compressor operation but system failing to produce cooling. Examined refrigerant lines and evaporator coil assembly within air handler, noting proper line insulation and drain line installation. Based on visual inspection of copper refrigerant lines showing discoloration patterns and system symptoms, diagnosed potential refrigerant charge issue or restriction in refrigerant circuit preventing proper heat transfer and cooling performance.
Streetsboro, OH 44241
Responded to reported crackling sounds from electrical panel occurring when high-draw appliances (microwave and washer) were in operation. Performed diagnostic inspection of main electrical panel and associated components. Upon examination, found disorganized wiring with multiple conductors bundled together throughout the panel enclosure, along with evidence of age-related wear and deterioration. Inspected all circuit breaker connections, bus bar contact points, and wire terminations for signs of arcing, overheating, or loose connections that could cause audible crackling. Verified proper torque on all breaker connections and main lugs. Evaluated panel capacity and load distribution across circuits to ensure adequate amperage for simultaneous operation of high-current appliances. Documented panel condition with photographs showing internal wiring configuration, breaker arrangement, and overall installation state for record-keeping purposes.
Responded to reported crackling sounds from electrical panel occurring when high-draw appliances (microwave and washer) were in operation. Performed diagnostic inspection of main electrical panel and associated components. Upon examination, found disorganized wiring with multiple conductors bundled together throughout the panel enclosure, along with evidence of age-related wear and deterioration. Inspected all circuit breaker connections, bus bar contact points, and wire terminations for signs of arcing, overheating, or loose connections that could cause audible crackling. Verified proper torque on all breaker connections and main lugs. Evaluated panel capacity and load distribution across circuits to ensure adequate amperage for simultaneous operation of high-current appliances. Documented panel condition with photographs showing internal wiring configuration, breaker arrangement, and overall installation state for record-keeping purposes.
Austin B.
Austin B. Checked in
Responded to reported crackling sounds from electrical panel occurring when high-draw appliances (microwave and washer) were in operation. Performed diagnostic inspection of main electrical panel and associated components. Upon examination, found disorganized wiring with multiple conductors bundled together throughout the panel enclosure, along with evidence of age-related wear and deterioration. Inspected all circuit breaker connections, bus bar contact points, and wire terminations for signs of arcing, overheating, or loose connections that could cause audible crackling. Verified proper torque on all breaker connections and main lugs. Evaluated panel capacity and load distribution across circuits to ensure adequate amperage for simultaneous operation of high-current appliances. Documented panel condition with photographs showing internal wiring configuration, breaker arrangement, and overall installation state for record-keeping purposes.
Streetsboro, OH 44241
Performed assessment of 24-year-old air conditioning system found to be completely empty of refrigerant. Documented existing HVAC ductwork and electrical panel configuration with measurements and photographs for replacement estimate purposes.
Performed assessment of 24-year-old air conditioning system found to be completely empty of refrigerant. Documented existing HVAC ductwork and electrical panel configuration with measurements and photographs for replacement estimate purposes.
Dustin J.
Dustin J. Checked in
Performed assessment of 24-year-old air conditioning system found to be completely empty of refrigerant. Documented existing HVAC ductwork and electrical panel configuration with measurements and photographs for replacement estimate purposes.
Streetsboro, OH 44241
Completed scheduled maintenance on 9-year-old air conditioning system under MVP agreement. Performed comprehensive inspection of indoor air handler components including blower wheel assembly, which showed clean operational condition with properly aligned blades and intact motor mounting. Verified attic-mounted unit accessibility, inspected air filtration system, and confirmed all mechanical components functioning within normal parameters. System operational and ready for cooling season.
Completed scheduled maintenance on 9-year-old air conditioning system under MVP agreement. Performed comprehensive inspection of indoor air handler components including blower wheel assembly, which showed clean operational condition with properly aligned blades and intact motor mounting. Verified attic-mounted unit accessibility, inspected air filtration system, and confirmed all mechanical components functioning within normal parameters. System operational and ready for cooling season.
Stephanie E.
Stephanie E. Checked in
Completed scheduled maintenance on 9-year-old air conditioning system under MVP agreement. Performed comprehensive inspection of indoor air handler components including blower wheel assembly, which showed clean operational condition with properly aligned blades and intact motor mounting. Verified attic-mounted unit accessibility, inspected air filtration system, and confirmed all mechanical components functioning within normal parameters. System operational and ready for cooling season.
Streetsboro, OH 44241
Completed comprehensive AC tune-up and preventative maintenance on 16-year-old air conditioning system. Performed full system inspection including refrigerant level check, electrical component testing, condenser and evaporator coil examination, air filter assessment, and thermostat calibration verification. System found operating properly with temperature readings confirming adequate cooling performance. All components functioning within normal parameters, and customer confirmed system working satisfactorily prior to service completion.
Completed comprehensive AC tune-up and preventative maintenance on 16-year-old air conditioning system. Performed full system inspection including refrigerant level check, electrical component testing, condenser and evaporator coil examination, air filter assessment, and thermostat calibration verification. System found operating properly with temperature readings confirming adequate cooling performance. All components functioning within normal parameters, and customer confirmed system working satisfactorily prior to service completion.
Kevin D.
Kevin D. Checked in
Completed comprehensive AC tune-up and preventative maintenance on 16-year-old air conditioning system. Performed full system inspection including refrigerant level check, electrical component testing, condenser and evaporator coil examination, air filter assessment, and thermostat calibration verification. System found operating properly with temperature readings confirming adequate cooling performance. All components functioning within normal parameters, and customer confirmed system working satisfactorily prior to service completion.
Streetsboro, OH 44241
Performed seasonal maintenance and flush service on an A.O. Smith tanked water heater in a residential property. Upon arrival, confirmed the unit was operating properly with no immediate issues noted. Executed complete tank flush procedure to remove sediment buildup, inspected all copper supply lines, brass fittings, and shut-off valves for proper operation and potential leaks. Verified expansion tank mounting and pressure settings, tested temperature and pressure relief valve functionality, and confirmed all connections were secure throughout the system.
Performed seasonal maintenance and flush service on an A.O. Smith tanked water heater in a residential property. Upon arrival, confirmed the unit was operating properly with no immediate issues noted. Executed complete tank flush procedure to remove sediment buildup, inspected all copper supply lines, brass fittings, and shut-off valves for proper operation and potential leaks. Verified expansion tank mounting and pressure settings, tested temperature and pressure relief valve functionality, and confirmed all connections were secure throughout the system.
Karl M.
Karl M. Checked in
Performed seasonal maintenance and flush service on an A.O. Smith tanked water heater in a residential property. Upon arrival, confirmed the unit was operating properly with no immediate issues noted. Executed complete tank flush procedure to remove sediment buildup, inspected all copper supply lines, brass fittings, and shut-off valves for proper operation and potential leaks. Verified expansion tank mounting and pressure settings, tested temperature and pressure relief valve functionality, and confirmed all connections were secure throughout the system.
Streetsboro, OH 44241
Responded to no cooling call and performed diagnostic evaluation of outdoor condensing unit. Upon inspection, discovered failed fuses in disconnect box preventing power to compressor and condenser fan motor. Removed and replaced dual Ferraz Shawmut TR40R 600V AC time-delay fuses, restored power to unit, and verified proper system operation with all components running within normal parameters.
Responded to no cooling call and performed diagnostic evaluation of outdoor condensing unit. Upon inspection, discovered failed fuses in disconnect box preventing power to compressor and condenser fan motor. Removed and replaced dual Ferraz Shawmut TR40R 600V AC time-delay fuses, restored power to unit, and verified proper system operation with all components running within normal parameters.
Colton D.
Colton D. Checked in
Responded to no cooling call and performed diagnostic evaluation of outdoor condensing unit. Upon inspection, discovered failed fuses in disconnect box preventing power to compressor and condenser fan motor. Removed and replaced dual Ferraz Shawmut TR40R 600V AC time-delay fuses, restored power to unit, and verified proper system operation with all components running within normal parameters.
Streetsboro, OH 44241
Performed comprehensive tune-up on 9-year-old residential air conditioning system. Inspected outdoor condenser unit, verified proper operation of compressor and condenser fan motor, checked electrical connections and control board functionality, and confirmed all components operating within normal parameters. Unit shows normal wear consistent with age; no immediate repairs required at this time.
Performed comprehensive tune-up on 9-year-old residential air conditioning system. Inspected outdoor condenser unit, verified proper operation of compressor and condenser fan motor, checked electrical connections and control board functionality, and confirmed all components operating within normal parameters. Unit shows normal wear consistent with age; no immediate repairs required at this time.
Hershel M.
Hershel M. Checked in
Performed comprehensive tune-up on 9-year-old residential air conditioning system. Inspected outdoor condenser unit, verified proper operation of compressor and condenser fan motor, checked electrical connections and control board functionality, and confirmed all components operating within normal parameters. Unit shows normal wear consistent with age; no immediate repairs required at this time.
Streetsboro, OH 44241

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image