Schedule Service

Air Conditioning, Heating, Electrical & Plumbing Services in Uniontown, OH

When you’re looking for a company to install, repair, and maintain all your HVAC, plumbing, and electrical systems in one fell swoop, there’s no need to worry about scheduling appointments with different service companies. At Blind & Sons, we handle it all! From leaky faucets and power outages to broken air conditioners and worn-out heaters.

Get everything you need for your Uniontown home from Blind & Sons! Call 330-362-9232 or contact us online for HVAC, electrical, or plumbing services today.

Air Conditioning Services

Air conditioning units

Your home is supposed to be a comfortable haven, but it becomes inconvenient when you can’t cool off or stay indoors because your air conditioner isn’t working correctly. A broken AC can also lead to other issues, including excessive humidity, which can result in mold growth and mildew. To keep your home from feeling like a swamp, our technicians can perform high-quality AC services, including:

Contact Blind & Sons online today or call 330-362-9232 to schedule a cooling service in Uniontown.

Need Services?

Heating Services

Depending on your heating unit, it can be tricky to know when it’s time to have it serviced by a professional. A few signs to look out for include excessive dust in your home when using your heater, little to no heat being produced, or if your pilot light is discolored. If one or more of these issues are happening with your heating unit, our technicians can get the job done in no time. Our heating specialists perform:

Make warm and cozy a default setting in your Uniontown home. Give us a call at 330-362-9232 or reach out to us online to schedule a heating service.

Indoor Air Quality Services

Indoor air quality is an often overlooked but deeply concerning issue for many homeowners. At Blind & Sons, we provide high-performance services that keep your home’s indoor air clean and safe to breathe using solutions, including:

Our indoor air quality services are guaranteed to clear your air of harmful particles, including pet dander, pollen, tobacco smoke, cleaning chemicals, and other airborne pathogens.

For help choosing the right indoor air quality solution for your home, call 330-362-9232 or contact Blind & Sons online for a free consultation.

Plumbing Services

Technician repairing water heater

When it comes to plumbing issues, every second counts. We offer plumbing repair services to protect your home from water damage, pipe damage, and other plumbing issues. To meet all your plumbing needs, we provide a wide range of plumbing services, including:

No plumbing issue is too much for our plumbing experts to handle. Get the help you need and call 330-362-9232 or contact Blind & Sons online to schedule a plumbing service in the Uniontown area.

Electrical Services

When experiencing problems with your electrical wiring, it can be dangerous to tackle it on your own if you don’t have experience or knowledge of electrical systems. To keep you and your loved ones safe, hire our professional electricians to take on the job. Whether you need new electrical wiring installed, have your old wiring repaired or maintained, or want extra protection in case of emergencies, we offer:

Avoid electrical fires and other electricity-related issues when you choose Blind & Sons. Reach out to us online or call 330-362-9232 to schedule an electrical service in Uniontown.

Why Choose Blind & Sons?

When it comes to the most high-quality plumbing, HVAC, and electrical services around, no better company does it better than Blind & Sons. With our online scheduling, we make getting services a breeze. We also offer a 100% satisfaction guarantee or your money back. So, what are you waiting for? Long-lasting comfort is just a phone call away!

Call us at 330-362-9232 or contact Blind & Sons online to schedule a plumbing, HVAC, or electrical service in Uniontown today.

Related Blogs:

 

Recent Jobs and Reviews in Uniontown, OH

Uniontown, OH at a glance

Blind and Sons has completed 20 jobs in Uniontown, OH in October 2026.

The most recent job was on October 28, 2026.

Blind and Sons has completed 408 jobs in Uniontown, OH in the last 12 months.

Job Locations and Reviews

Performed scheduled preventive heating maintenance on the Lennox gas furnace, inspecting the Honeywell control module, associated wiring, flexible conduit, and electrical connections for proper condition. Verified the PVC vent and condensate piping and couplings, noting only minor discoloration at the joints with no leaks, frost, or heavy corrosion observed. Checked the Space-Gard air cleaner and Second Wind unit and confirmed equipment is in serviceable condition with maintenance documentation on file.
Performed scheduled preventive heating maintenance on the Lennox gas furnace, inspecting the Honeywell control module, associated wiring, flexible conduit, and electrical connections for proper condition. Verified the PVC vent and condensate piping and couplings, noting only minor discoloration at the joints with no leaks, frost, or heavy corrosion observed. Checked the Space-Gard air cleaner and Second Wind unit and confirmed equipment is in serviceable condition with maintenance documentation on file.
Daniel S.
Daniel S. Checked in
Performed scheduled preventive heating maintenance on the Lennox gas furnace, inspecting the Honeywell control module, associated wiring, flexible conduit, and electrical connections for proper condition. Verified the PVC vent and condensate piping and couplings, noting only minor discoloration at the joints with no leaks, frost, or heavy corrosion observed. Checked the Space-Gard air cleaner and Second Wind unit and confirmed equipment is in serviceable condition with maintenance documentation on file.
Uniontown, OH 44685
Performed a seasonal heating system maintenance inspection, including evaluation of the return air filter, which showed visible dust loading and minor frame wear. Removed and inspected the flame sensor, which exhibited light oxidation and surface residue, and cleaned it to restore reliable flame rectification and ignition performance.
Performed a seasonal heating system maintenance inspection, including evaluation of the return air filter, which showed visible dust loading and minor frame wear. Removed and inspected the flame sensor, which exhibited light oxidation and surface residue, and cleaned it to restore reliable flame rectification and ignition performance.
Stephanie E.
Stephanie E. Checked in
Performed a seasonal heating system maintenance inspection, including evaluation of the return air filter, which showed visible dust loading and minor frame wear. Removed and inspected the flame sensor, which exhibited light oxidation and surface residue, and cleaned it to restore reliable flame rectification and ignition performance.
Uniontown, OH 44685
Performed scheduled heating maintenance and combustion analysis on the natural gas appliance using a Bacharach analyzer, recording O2 at 10.4%, CO at 27 ppm, CO2 at 5.9%, and combustion efficiency at 77.4%. Inspected the blower and burner compartment, noting dirty, worn conditions with discoloration, sealant residue, and staining around the fitting and surrounding components, and documented the findings for further evaluation as needed.
Performed scheduled heating maintenance and combustion analysis on the natural gas appliance using a Bacharach analyzer, recording O2 at 10.4%, CO at 27 ppm, CO2 at 5.9%, and combustion efficiency at 77.4%. Inspected the blower and burner compartment, noting dirty, worn conditions with discoloration, sealant residue, and staining around the fitting and surrounding components, and documented the findings for further evaluation as needed.
Stephanie E.
Stephanie E. Checked in
Performed scheduled heating maintenance and combustion analysis on the natural gas appliance using a Bacharach analyzer, recording O2 at 10.4%, CO at 27 ppm, CO2 at 5.9%, and combustion efficiency at 77.4%. Inspected the blower and burner compartment, noting dirty, worn conditions with discoloration, sealant residue, and staining around the fitting and surrounding components, and documented the findings for further evaluation as needed.
Uniontown, OH 44685
Performed a tune-up on a 6-year-old natural gas furnace, including inspection and replacement of a dirty, debris-laden air filter. Conducted combustion analysis with a Bacharach analyzer, recording O₂ at 9.6%, CO at 36 ppm, CO₂ at 6.4%, and combustion efficiency of 78.1%. Readings were documented for the equipment record.
Performed a tune-up on a 6-year-old natural gas furnace, including inspection and replacement of a dirty, debris-laden air filter. Conducted combustion analysis with a Bacharach analyzer, recording O₂ at 9.6%, CO at 36 ppm, CO₂ at 6.4%, and combustion efficiency of 78.1%. Readings were documented for the equipment record.
Taylor F.
Taylor F. Checked in
Performed a tune-up on a 6-year-old natural gas furnace, including inspection and replacement of a dirty, debris-laden air filter. Conducted combustion analysis with a Bacharach analyzer, recording O₂ at 9.6%, CO at 36 ppm, CO₂ at 6.4%, and combustion efficiency of 78.1%. Readings were documented for the equipment record.
Uniontown, OH 44685
Uninstalled the existing outdoor condensing unit and constructed a new gravel-bed equipment base with a paver, then reset the unit and verified it was level on all sides using a torpedo level. Reconnected the insulated refrigerant lines, flexible conduit, and electrical disconnect, and confirmed the unit was secure and properly positioned against the structure with clearance maintained.
Uninstalled the existing outdoor condensing unit and constructed a new gravel-bed equipment base with a paver, then reset the unit and verified it was level on all sides using a torpedo level. Reconnected the insulated refrigerant lines, flexible conduit, and electrical disconnect, and confirmed the unit was secure and properly positioned against the structure with clearance maintained.
Ethan F.
Ethan F. Checked in
Uninstalled the existing outdoor condensing unit and constructed a new gravel-bed equipment base with a paver, then reset the unit and verified it was level on all sides using a torpedo level. Reconnected the insulated refrigerant lines, flexible conduit, and electrical disconnect, and confirmed the unit was secure and properly positioned against the structure with clearance maintained.
Uniontown, OH 44685
Performed seasonal heating maintenance and inspected the system with a borescope, which revealed surface corrosion and peeling with rust exposure and a small void on an internal component, indicating possible deterioration that warrants further evaluation. Cleaned accumulated dust and debris from the outdoor unit's fan guard and grille to restore proper airflow and system efficiency.
Performed seasonal heating maintenance and inspected the system with a borescope, which revealed surface corrosion and peeling with rust exposure and a small void on an internal component, indicating possible deterioration that warrants further evaluation. Cleaned accumulated dust and debris from the outdoor unit's fan guard and grille to restore proper airflow and system efficiency.
Stephanie E.
Stephanie E. Checked in
Performed seasonal heating maintenance and inspected the system with a borescope, which revealed surface corrosion and peeling with rust exposure and a small void on an internal component, indicating possible deterioration that warrants further evaluation. Cleaned accumulated dust and debris from the outdoor unit's fan guard and grille to restore proper airflow and system efficiency.
Uniontown, OH 44685
Responded to a no-heat call on a 15-year-old gas furnace and inspected the control compartment, including the control board, transformer, capacitor, gas valve, pressure switch, and draft inducer assembly. Found heavy corrosion on the cabinet floor and surrounding surfaces, along with loose, unsecured wiring and a rusted gas pipe elbow, conditions consistent with moisture exposure and age. Documented all findings with photos; recommend further diagnostics and corrective repair or replacement evaluation due to the unit's age and extent of corrosion.
Responded to a no-heat call on a 15-year-old gas furnace and inspected the control compartment, including the control board, transformer, capacitor, gas valve, pressure switch, and draft inducer assembly. Found heavy corrosion on the cabinet floor and surrounding surfaces, along with loose, unsecured wiring and a rusted gas pipe elbow, conditions consistent with moisture exposure and age. Documented all findings with photos; recommend further diagnostics and corrective repair or replacement evaluation due to the unit's age and extent of corrosion.
Jibreel H.
Jibreel H. Checked in
Responded to a no-heat call on a 15-year-old gas furnace and inspected the control compartment, including the control board, transformer, capacitor, gas valve, pressure switch, and draft inducer assembly. Found heavy corrosion on the cabinet floor and surrounding surfaces, along with loose, unsecured wiring and a rusted gas pipe elbow, conditions consistent with moisture exposure and age. Documented all findings with photos; recommend further diagnostics and corrective repair or replacement evaluation due to the unit's age and extent of corrosion.
Uniontown, OH 44685
Following inspection, the 6x6 pressure-treated post supporting the pool electrical service box and conduit was trimmed to the top of the enclosure to complete the installation as originally specified. The conduit trench along the foundation was found to be loosely backfilled with uncompacted soil and is noted as needing additional compaction and site cleanup.
Following inspection, the 6x6 pressure-treated post supporting the pool electrical service box and conduit was trimmed to the top of the enclosure to complete the installation as originally specified. The conduit trench along the foundation was found to be loosely backfilled with uncompacted soil and is noted as needing additional compaction and site cleanup.
Eric L.
Eric L. Checked in
Following inspection, the 6x6 pressure-treated post supporting the pool electrical service box and conduit was trimmed to the top of the enclosure to complete the installation as originally specified. The conduit trench along the foundation was found to be loosely backfilled with uncompacted soil and is noted as needing additional compaction and site cleanup.
Uniontown, OH 44685
Performed a full flush and refill of the gas-fired tank-style water heater to remove accumulated sediment and restore heating efficiency. The unit was drained, flushed until the discharge ran clear, then refilled and returned to service, with the drip pan, flue, and gas control assembly showing no visible rust or physical damage.
Performed a full flush and refill of the gas-fired tank-style water heater to remove accumulated sediment and restore heating efficiency. The unit was drained, flushed until the discharge ran clear, then refilled and returned to service, with the drip pan, flue, and gas control assembly showing no visible rust or physical damage.
James P.
James P. Checked in
Performed a full flush and refill of the gas-fired tank-style water heater to remove accumulated sediment and restore heating efficiency. The unit was drained, flushed until the discharge ran clear, then refilled and returned to service, with the drip pan, flue, and gas control assembly showing no visible rust or physical damage.
Uniontown, OH 44685
Responded to a no-heat complaint on a 28-year-old furnace and found the inducer blower housing and pressure tubing in poor condition, with heavy rust and corrosion on the cabinet floor and mineral-stained, corroded piping at the elbow fitting, indicating long-term moisture exposure. Because the required replacement part is unavailable and the unit's age and extent of corrosion make repair impractical, a furnace replacement was recommended and an estimate was prepared.
Responded to a no-heat complaint on a 28-year-old furnace and found the inducer blower housing and pressure tubing in poor condition, with heavy rust and corrosion on the cabinet floor and mineral-stained, corroded piping at the elbow fitting, indicating long-term moisture exposure. Because the required replacement part is unavailable and the unit's age and extent of corrosion make repair impractical, a furnace replacement was recommended and an estimate was prepared.
Dave T.
Dave T. Checked in
Responded to a no-heat complaint on a 28-year-old furnace and found the inducer blower housing and pressure tubing in poor condition, with heavy rust and corrosion on the cabinet floor and mineral-stained, corroded piping at the elbow fitting, indicating long-term moisture exposure. Because the required replacement part is unavailable and the unit's age and extent of corrosion make repair impractical, a furnace replacement was recommended and an estimate was prepared.
Uniontown, OH 44685
Shut off the exterior waterline at the main interior shutoff valve, a gate valve on the blue PEX supply line, to prepare the system for winter. The valve showed corrosion and surrounding insulation was discolored, indicating prior moisture exposure. The sump pit, pump, and discharge piping were also observed during the visit.
Shut off the exterior waterline at the main interior shutoff valve, a gate valve on the blue PEX supply line, to prepare the system for winter. The valve showed corrosion and surrounding insulation was discolored, indicating prior moisture exposure. The sump pit, pump, and discharge piping were also observed during the visit.
Denny J.
Denny J. Checked in
Shut off the exterior waterline at the main interior shutoff valve, a gate valve on the blue PEX supply line, to prepare the system for winter. The valve showed corrosion and surrounding insulation was discolored, indicating prior moisture exposure. The sump pit, pump, and discharge piping were also observed during the visit.
Uniontown, OH 44685
Replaced the heat exchanger and limit switch on the furnace after inspection confirmed the failed components. Performed a borescope inspection of the heat exchanger and plenum area, and verified supply air temperature after installation to confirm proper operation.
Replaced the heat exchanger and limit switch on the furnace after inspection confirmed the failed components. Performed a borescope inspection of the heat exchanger and plenum area, and verified supply air temperature after installation to confirm proper operation.
Colton D.
Colton D. Checked in
Replaced the heat exchanger and limit switch on the furnace after inspection confirmed the failed components. Performed a borescope inspection of the heat exchanger and plenum area, and verified supply air temperature after installation to confirm proper operation.
Uniontown, OH 44685
Responded to a non-operational 17-year-old Kohler natural gas standby generator with flashing fault indicators on the automatic transfer switch. Performed a diagnostic inspection of the generator enclosure, including the Kohler digital controller, terminal block wiring, fuel regulator and solenoid valve assembly, and engine compartment, noting no visible damage, corrosion, or fuel line deficiencies, with only minor cobweb accumulation and debris present. Findings and recommendations were documented for the unit's age and condition.
Responded to a non-operational 17-year-old Kohler natural gas standby generator with flashing fault indicators on the automatic transfer switch. Performed a diagnostic inspection of the generator enclosure, including the Kohler digital controller, terminal block wiring, fuel regulator and solenoid valve assembly, and engine compartment, noting no visible damage, corrosion, or fuel line deficiencies, with only minor cobweb accumulation and debris present. Findings and recommendations were documented for the unit's age and condition.
Eric L.
Eric L. Checked in
Responded to a non-operational 17-year-old Kohler natural gas standby generator with flashing fault indicators on the automatic transfer switch. Performed a diagnostic inspection of the generator enclosure, including the Kohler digital controller, terminal block wiring, fuel regulator and solenoid valve assembly, and engine compartment, noting no visible damage, corrosion, or fuel line deficiencies, with only minor cobweb accumulation and debris present. Findings and recommendations were documented for the unit's age and condition.
Uniontown, OH 44685
Responded to a no-heat call on a 12-year-old Lennox Elite Series gas furnace and inspected the inducer motor assembly, gas valve, control board, and cabinet. Found severe rust and corrosion on the cabinet floor and blower shelf, along with corroded threaded gas piping and fittings near the gas valve, indicating long-term moisture exposure. Documented the condition with photos and recommended inducer motor replacement and further evaluation of the corroded gas piping and cabinet integrity before returning the unit to service.
Responded to a no-heat call on a 12-year-old Lennox Elite Series gas furnace and inspected the inducer motor assembly, gas valve, control board, and cabinet. Found severe rust and corrosion on the cabinet floor and blower shelf, along with corroded threaded gas piping and fittings near the gas valve, indicating long-term moisture exposure. Documented the condition with photos and recommended inducer motor replacement and further evaluation of the corroded gas piping and cabinet integrity before returning the unit to service.
William S.
William S. Checked in
Responded to a no-heat call on a 12-year-old Lennox Elite Series gas furnace and inspected the inducer motor assembly, gas valve, control board, and cabinet. Found severe rust and corrosion on the cabinet floor and blower shelf, along with corroded threaded gas piping and fittings near the gas valve, indicating long-term moisture exposure. Documented the condition with photos and recommended inducer motor replacement and further evaluation of the corroded gas piping and cabinet integrity before returning the unit to service.
Uniontown, OH 44685
Responded to a no-heat call on a 10-year-old Lennox gas furnace in the basement and inspected the control compartment, including the integrated furnace control board, low-voltage wiring, splices, and the 3A fuse. Observed disorganized, loosely routed wiring with multiple wire-nut splices; tested the system with a diagnostic probe to check board inputs and verify heat call operation. Restored furnace operation and confirmed proper heating cycle.
Responded to a no-heat call on a 10-year-old Lennox gas furnace in the basement and inspected the control compartment, including the integrated furnace control board, low-voltage wiring, splices, and the 3A fuse. Observed disorganized, loosely routed wiring with multiple wire-nut splices; tested the system with a diagnostic probe to check board inputs and verify heat call operation. Restored furnace operation and confirmed proper heating cycle.
William S.
William S. Checked in
Responded to a no-heat call on a 10-year-old Lennox gas furnace in the basement and inspected the control compartment, including the integrated furnace control board, low-voltage wiring, splices, and the 3A fuse. Observed disorganized, loosely routed wiring with multiple wire-nut splices; tested the system with a diagnostic probe to check board inputs and verify heat call operation. Restored furnace operation and confirmed proper heating cycle.
Uniontown, OH 44685
Responded to a repeat warranty call for a unit with a recurring leak following previous PCB replacement. Inspected the condensate drain assembly and cabinet penetration, resealed the drain pipe fitting and cabinet opening with sealant, and cleared the ice accumulation and moisture from the drain piping and surrounding components. Verified the drain line was secure and the leak source was addressed.
Responded to a repeat warranty call for a unit with a recurring leak following previous PCB replacement. Inspected the condensate drain assembly and cabinet penetration, resealed the drain pipe fitting and cabinet opening with sealant, and cleared the ice accumulation and moisture from the drain piping and surrounding components. Verified the drain line was secure and the leak source was addressed.
John W.
John W. Checked in
Responded to a repeat warranty call for a unit with a recurring leak following previous PCB replacement. Inspected the condensate drain assembly and cabinet penetration, resealed the drain pipe fitting and cabinet opening with sealant, and cleared the ice accumulation and moisture from the drain piping and surrounding components. Verified the drain line was secure and the leak source was addressed.
Uniontown, OH 44685
Performed annual preventative maintenance on a 2-year-old gas heating system, including a combustion analysis with a Bacharach analyzer that returned natural gas readings of 82 ppm CO, 93.7% efficiency, 8.4% CO2, and 112°F stack temperature. Verified the carbon monoxide alarm is present and in good physical condition, and the customer's maintenance plan was renewed.
Performed annual preventative maintenance on a 2-year-old gas heating system, including a combustion analysis with a Bacharach analyzer that returned natural gas readings of 82 ppm CO, 93.7% efficiency, 8.4% CO2, and 112°F stack temperature. Verified the carbon monoxide alarm is present and in good physical condition, and the customer's maintenance plan was renewed.
Jesus M.
Jesus M. Checked in
Performed annual preventative maintenance on a 2-year-old gas heating system, including a combustion analysis with a Bacharach analyzer that returned natural gas readings of 82 ppm CO, 93.7% efficiency, 8.4% CO2, and 112°F stack temperature. Verified the carbon monoxide alarm is present and in good physical condition, and the customer's maintenance plan was renewed.
Uniontown, OH 44685
Installed a 22kW Generac standby generator with a 150-amp automatic transfer switch, running approximately 30 feet of electrical feeder and coordinating with the gas contractor, who supplied approximately 40 feet of gas line. Terminated and connected the transfer switch to the main service panel and verified proper operation of the system.
Installed a 22kW Generac standby generator with a 150-amp automatic transfer switch, running approximately 30 feet of electrical feeder and coordinating with the gas contractor, who supplied approximately 40 feet of gas line. Terminated and connected the transfer switch to the main service panel and verified proper operation of the system.
Landon M.
Landon M. Checked in
Installed a 22kW Generac standby generator with a 150-amp automatic transfer switch, running approximately 30 feet of electrical feeder and coordinating with the gas contractor, who supplied approximately 40 feet of gas line. Terminated and connected the transfer switch to the main service panel and verified proper operation of the system.
Uniontown, OH 44685
Located and repaired a corroded copper supply line feeding the refrigerator, with mineral buildup and verdigris evident at the soldered joints adjacent to the brass ball shutoff valve. Isolated the water supply at the shutoff, cut out and replaced the compromised section of copper with new fittings, then restored service and verified the joints were leak-free under pressure.
Located and repaired a corroded copper supply line feeding the refrigerator, with mineral buildup and verdigris evident at the soldered joints adjacent to the brass ball shutoff valve. Isolated the water supply at the shutoff, cut out and replaced the compromised section of copper with new fittings, then restored service and verified the joints were leak-free under pressure.
Travis B.
Travis B. Checked in
Located and repaired a corroded copper supply line feeding the refrigerator, with mineral buildup and verdigris evident at the soldered joints adjacent to the brass ball shutoff valve. Isolated the water supply at the shutoff, cut out and replaced the compromised section of copper with new fittings, then restored service and verified the joints were leak-free under pressure.
Uniontown, OH 44685
Performed an on-site evaluation for a full AC and furnace replacement, inspecting the existing furnace plenum, supply duct, and Honeywell air cleaner cabinet in the utility room and measuring the duct dimensions to determine proper equipment sizing and transition requirements. Inspected the outdoor condenser, noting significant corrosion on the fan guard and hub, along with the disconnect and conduit connections. Documented existing conditions and rust damage to support replacement recommendations for both the condenser and furnace.
Performed an on-site evaluation for a full AC and furnace replacement, inspecting the existing furnace plenum, supply duct, and Honeywell air cleaner cabinet in the utility room and measuring the duct dimensions to determine proper equipment sizing and transition requirements. Inspected the outdoor condenser, noting significant corrosion on the fan guard and hub, along with the disconnect and conduit connections. Documented existing conditions and rust damage to support replacement recommendations for both the condenser and furnace.
Dustin J.
Dustin J. Checked in
Performed an on-site evaluation for a full AC and furnace replacement, inspecting the existing furnace plenum, supply duct, and Honeywell air cleaner cabinet in the utility room and measuring the duct dimensions to determine proper equipment sizing and transition requirements. Inspected the outdoor condenser, noting significant corrosion on the fan guard and hub, along with the disconnect and conduit connections. Documented existing conditions and rust damage to support replacement recommendations for both the condenser and furnace.
Uniontown, OH 44685

why choose blind & Sons?

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

get to know us more

Your satisfaction is 100% Guaranteed or you get your money back!

Schedule Service Online

Conveniently request an appointment in seconds without picking up the phone.

Refer friends to Blind & Sons and earn cash with each purchase they make.

Keep your home comfortable and enjoy service discounts with our Maintenance Value Plan.

Review Image
Our Reviews

See What Your Neighbors Are Saying

My mother recently needed her central air and heating system replaced. She called around to several companies, but unfortunately, many of them gave her the runaround—likely taking advantage of the fact that she’s a woman who doesn’t speak English well. I was deeply upset by some…

Sincerely Eng Tran

Sincerely Eng Tran

The team of R.T., S.M and N.B did an amazing job. They literally worked their butts off, and their attention to detail was truly above the bar. I will be happy to pass along your contact information during conversation and show & tell. Appreciate your eagerness…

Jim. F.

Jim. F.

For the very positive, service person (A.G.) was excellent: locating the exact location of the plumbing leak within an upstairs bathroom wall, cutting an access opening with minimal damage to the tiled shower wall, and repairing the leak. He was also good at explaining the mechanics…

J. M.

J. M.

These folks stay true to this day. From being easy work with, their professionalism to the quality of work that is put in. Blind & Sons will remain to be my go to company. An additional thanks to L.P. for a top notch service experience. The…

Corey A.

Corey A.

An electrician from Blind and Sons came to repair a wire in my basement so I could finish the sale of my home. He was prompt, knowledgeable and explained what he was going to do, and the cost to me, before completing the work. He also…

Dan C.

Dan C.

Review Image